Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.6 CrAccepted-AOC | ₹11.6 Cr Quoted ₹12.7 Cr | 1 | Accepted-AOC Accepted |
| 2 | 2₹12.9 CrRejected-Finance 48 5B2 SRI SHWETHA COMPLEX THANJAI MAIN ROAD THIRUVERUMBUR TRICHY 620013 | TRICHY | TIRUCHIRAPPALLI | TAMIL NADU | 620013 | ₹12.9 Cr | 2 | Rejected-Finance L1 Lowest Tenderer can only be accepted. L2 is Rejected |
| 3 | 3₹13.4 CrRejected-Finance NO 11 ANNAI VELANKANNI STREET KAMARAJ NAGAR PUDUCHERRY 605 011 | PONDICHERRY | PUDUCHERRY | 605011 | ₹13.4 Cr | 3 | Rejected-Finance L1 Lowest Tenderer can only be accepted. L3 is Rejected |
| Sl No | Description | Qty | Unit | RR INFRAA CONSTRUCTION L1 | Omsakthiconstructions L3 | SD INFRA PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00Earth work Excavation in all classes of soils except hard rock not requiring blasting and depositing on bank with all leads and lifts as per SS20B including cost of all labour, materials, tools, equipments and all incidental charges and sheeting, shoring, bracing and their subsequent removal, removal of all logs, stumps and other deleterious matter and obstructions, trimming of bottom of excavtion, backfilling, and clearing the site and disposal of all surplus materials etc. complete as per standard specification for Foundation | ||||||
| 1.10 | FOB | 1,548 | Cubic Metre | 457 ₹7.1 L | 483.9 ₹7.5 L | 470 ₹7.3 L |
| 1.20 | Maintenance & Generator Room | 21.78 | Cubic Metre | 457 ₹9,953.46 | 483.9 ₹10,539.34 | 470 ₹10,236.60 |
| 2.00Plain Cement Concrete M15 Grade using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site,cost and labour charges for form work and centering, labour charges for compacting, curing and all incidental charges etc., complete for LEVELLING COURSE BELOW FOOTINGS as per relevant MORT&H Specifications cl: 1000&2100. | ||||||
| 2.10 | FOB | 37 | Cubic Metre | 7,608 ₹2.8 L | 8,046.9 ₹3.0 L | 7,790 ₹2.9 L |
| 2.20 | Maintenance & Generator Room | 1.45 | Cubic Metre | 7,747 ₹11,233.15 | 8,194 ₹11,881.30 | 8,105 ₹11,752.25 |
| 3.00Vibrated Reinforced Cement Concrete of grade M30 (Design Mix) using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for FOOTINGS as per relevent MORT&H specification Cl:1000,1500,1600 &1700. | ||||||
| 3.10 | FOB | 309 | Cubic Metre | 11,659 ₹36.0 L | 12,330.6 ₹38.1 L | 11,985 ₹37.0 L |
| 3.20 | Maintenance & Generator Room | 2.92 | Cubic Metre | 15,755 ₹46,004.60 | 16,663.1 ₹48,656.25 | 16,235 ₹47,406.20 |
| 4.00Vibrated Reinforced Cement Concrete of grade M30 (Design Mix) using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for FLOOR SLAB CUM BEAM AND LINTEL OF MAINTENANCE ROOM as per relevent Specifications of MORT&H Cl: 1000,1500,1600,1700&2300 | ||||||
Tender Value
₹10.7 Cr
EMD Value
₹5.5 L
Closing Date
20 Aug 2025, 11:00 amClosed
Superintending Engineer H C and M
The Superintending Engineer Highways Department Construction Maintenance 214 Tindivanam Road Tiruvannamalai 606 601
Construction of Foot Over Bridge at Km 103/8 of Pondy Krishnagiri road (NH 66 Abandoned Stretch) with Escalator Across the Railway Track (Near Tiruvannamalai New Bus Stand)
2025_HWAY_583076_1
TN No 09 2025 26 HDO Dt 11 07 2025 FOB
Open Tender
Civil Works - Highways
180 days
Tiruvannamalai
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹5.5 L
Tiruvannamalai
12 Mar 2026
19 Jul 2025
20 Aug 2025
19 Jul 2025
20 Aug 2025
19 Jul 2025
19 Jul 2025 - 25 Jul 2025
23 Jul 2025
Amount
Earth work Excavation in all classes of soils except hard rock not requiring blasting and depositing on bank with all leads and lifts as per SS20B including cost of all labour, materials, tools, equipments and all incidental charges and sheeting, shoring, bracing and their subsequent removal, removal of all logs, stumps and other deleterious matter and obstructions, trimming of bottom of excavtion, backfilling, and clearing the site and disposal of all surplus materials etc. complete as per standard specification for Foundation
Maintenance & Generator Room
Plain Cement Concrete M15 Grade using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site,cost and labour charges for form work and centering, labour charges for compacting, curing and all incidental charges etc., complete for LEVELLING COURSE BELOW FOOTINGS as per relevant MORT&H Specifications cl: 1000&2100.
Maintenance & Generator Room
Vibrated Reinforced Cement Concrete of grade M30 (Design Mix) using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for FOOTINGS as per relevent MORT&H specification Cl:1000,1500,1600 &1700.
Maintenance & Generator Room
Vibrated Reinforced Cement Concrete of grade M30 (Design Mix) using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for FLOOR SLAB CUM BEAM AND LINTEL OF MAINTENANCE ROOM as per relevent Specifications of MORT&H Cl: 1000,1500,1600,1700&2300
Maintenance & Generator Room
Supply and fabrication of HYSD STEEL of grade Fe 500 D/CRS/HCRM/Anti corrossive treatment including cost of steel, cost of fabrication, labour charges for cleaning the rods, straightening, cutting, bending, tying grills, placing the reinforcement in position as specified in the drawing including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc., complete for FOOTINGS, PEDESTALS and DRAIN CUM FOOTPATH as per relevant MORT&H Specifications Cl:1600.
Maintenance & Generator Room
Vibrated Reinforced Cement Concrete of grade M35 (Design Mix) using 20mm ISS size hard broken granite metal including cost and conveyance of all materials to site, cost and labour charges for formwork, cost of soft water, labour charges for mixing, transporting, laying, compacting and curing, working at depths, Tools and Plants and incidental charges such as bailing out water, shoring, strutting etc., complete for DECK SLAB with kerb over decking sheet as per MORT&H specifications Cl:1000,1500,1600, 1700 and 2300.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges.
Providing and applying one coat of Zinc oxide primer and two coats of Anti Corrosive paint of Colour as directed by engineer in charge on structural steel , etc all complete as per technical specification in accordance with IRC 24-2010 and other relevant MORT&H Specifications Cl:1906.
Brick masonry in Cement Mortar 1:6, 230 mm thick using best quality II class ground moulded chamber burnt bricks of size 9" x 4 3/8" x 2 3/4" including cost towards curing, etc., complete complying with standard specification.
Maintenance & Generator Room
Plastering with Cement Mortar 1:4 (one cement & four sand), 12 mm thick on brick work for internal sides of walls in all floors as per Technical Specifications
Maintenance & Generator Room
Plastering with Cement Mortar 1:4 (one cement & four sand), 20 mm thick on brick work for External sides of walls in all floors as per Technical Specifications
Maintenance & Generator Room
Chequerred precast Cement based hydraulically pressed anti-skid (Pattern Design) tiles, 20mm thick laid in CM 1:3 (one cement & three sand) and pointed with white cement mixed with colouring pigment @ 0.40 Kg/Sqm and cost towards curing,etc., Complete for Main Skywalk, Staircase, Kerb as per technical specifications.
Supply and erection of public service HEAVY DUTY ESCALATORS outdoor type (GS8000-NX) with the Techniccal Specification as Step Width:1700mm, Rise:6500mm, Inclination Angle:30 degree, Speed: 24m/min, Power supply:220V/400V, 50Hz. Material Specification such as Handrails made of Polyuerthane(Blood red colour), Handrail frame of Hairline(finished stainless steel), Deck cover of Hairline(finished stainless steel), Interior panel-Balustrade of TYPE-P (Stainless steel), Skirt Guard of Hairline (finished stainless steel), Step tread of Stainless steel with synthetic Resin Demarcation(Yellow), Floor plate Comb of Synthetic Resin (Yellow), Landing plate of Aluminium including all necessary safety devices & accessories, comb light shall be mounted on the skirp guard with 1m center to center arrangement and complete in all respects and as directed by the Engineer-in-Charge.
Passenger Lift MRL, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD. (13 Persons)
Supply of 125 KVA DIESEL GENERATOR as per CPCB-2 norms at 1500 RPM under NTP conditions complete with standard accessories rated at 125 KVA 0.8PF (lag), 415V, 3phase, 4wire, mounted on a common iron based frame, suitably rated battery with leads, silencer, fuel tank, manual Control Panel and set of AVM pads, composite type enclosure and AMF panel suitable for 1 EB connection shall be kept outside and inside enclosure (in lieu of Manual Control Panel) with all other neccesory accessories and complete in all respect as per relevant technical specification and as directed by the Engineer-in-Charge.
Providing and applying two coats of acrylic paint to the external and internal surfaces of plastered finish, using exterior quality acrylic weather shield paint of approved shade and make including preparing the base surface, attending to broken edges, corners etc. as per technical specifications.
Maintenance & Generator Room
Flooring with first quality design Coloured Ceramic tiles of 305 x 305 x 6 mm size, laid over 20mm thick Cement Mortar 1:3 (one cement & three sand) base mortar over walls including cutting the tiles to required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment @ 0.30 Kg/sqm etc., complete as per technical specifications.
Maintenance & Generator Room
Supplying, fabricating and fixing in position of aluminium anodized DOOR partly half glazed at top and half panelled at bottom with frame made out of box section 101.6 x 44.5 x 3.18 mm thick @ 2.319 kg/m door shutters made out of box section 47.1 x 44.45 x 2.50 mm @ 1.202 kg/m for vertical slide and top, lock rail sections of size 50 x 44.5 x 2.5 mm @ 1.292 kg/m and bottom 100.4 x 44.45 x 2.5mm @ 1.974 kg/m using clips of size 17.15 x 17.27 x 1.50 mm @ 0.176 kg/m with neccesary metal screws, rubber beadings, strike plate type handle of size 100 x 30 x 1.60 mm @ 0.988 kg/m on both sides, tower bolts, lock pivot arrangements and top half portion with 5.50 mm thick plain glass and bottom half portion with one side pre-laminated board (MDF) 12mm thick for panelled portions with one number of hydraullic door closure of approved quality using alluminium extruded section body tubular type universal with double speed adjustment with ISI Monogram including cost of furniture fitting such as pivot, hinges, tower bolt, lock, door stopper and all materials , labour power consumtion required for fabrication,drilling required for fabrication,drilling holes in RCC columns, floor slabs, Masonry walls wherever neccessary with power drills to the required extent and make the same to original condition after fixing and as directed. All the alluminium sections are to be anodized with mat finish under electrical controlled condition in accordance with IS:1868 - 1962 for an average anodic film thickness of 15 microns etc., complete. The rate shall be inclusive of materials, labour for fixing, transporting, loading ,unloading etc.,
Maintenance & Generator Room
Supplying, fabricating and fixing in position aluminium natural colour matt finish WINDOW /VENTILATOR with sliding and gutter arrangements so as to drain the water entering and made with extruded aluminium section of the sizes given below with necessary accessories such as rubber beadings, best quality runner, lock, handle supplying and fixing 4 mm thick plain glass including cost of all materials, labour, power consumption required for fabrication, drilling holes in RCC Column/floor slab/masonry wall wherever necessary with power drills to the required extent and made same to original condition after fixing etc.,complete. The aluminium sections are to be anodized with matt finish under electrically controlled condition in accordance with ISI 1868-1962 for an average anodic film thickness of no less than 15 microns. All aluminium sections and furniture fittings shall be got approved by the Engineer-in-Charge before use on works.
Maintenance & Generator Room
Supplying and erection of push and pull type ROLLING SHUTTERS (Gear Operated type) with ISI make of approved size and section using 18 G.I. sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges,etc.,
Maintenance & Generator Room
Fabrication,Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, wall mounted panel board made out of 16 SWG thick CRCA sheet , duly rust inhibited,degreasing,zinc phosphating and painted with epoxy paints of approved colour and quality over a coat of zinc-cromatic primer and properly powder coated, complete with hinged and earthed front doors , name plate,danger notice board, heavy duty rubber gaskets, removable gland plates made of 3mm thick sheet steel, all connections and inter-connections including mounting the following . Incomings:315 A Rewireable fuse with base- 3Nos. 315 A Neutral link - 1No. 250 A TPN SDFU Provision for mounting of 3 phase energy meter Supply & Labour.
Electrical (EB METERING PANEL) Supply
Electrical (EB METERING PANEL) Labour
Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. All opening parts of the panel shall be sealable. (the panel shall have CPRI approval certificate) Incomer: 250 A TPN SDFU - 1 No 250 A 415V 25kA best conductivity AluminiumTPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Outgoings: 200A TPN SDFU - 2 Nos Rate to be quoted for Supply & Labour.
Electrical (Sub Panel) Supply
Electrical (Sub Panel) Labour
Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. All opening parts of the panel shall be sealable. (the panel shall have CPRI approval certificate) Incomer: 200 A TPN MCCB - 1 No 200 A 415V 25kA best conductivity AluminiumTPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Outgoings: 100 A TPN 25kA MCCB - 4 Nos + 63 A TPN 25kA MCCB - 4 Nos Rate to be quoted for Supply & Labour.
Electrical (Main Panel) Supply
Electrical (Main Panel) Labour
Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. All opening parts of the panel shall be sealable. (the panel shall have CPRI approval certificate) Incoming Feeders One (1 ) 200A, TPN, SDF One (1) - set indicating lamps as required to indicate ON, OFF, & TRIP circuit healthy and also phase indicating lamps. 200/ 5A, 5VA/Cl 1.0, 5VA for PF Control . Short time rating of CTs shall be 25kA for one (1) second. Suitable for 3phase, 4wire, 50HZ, 415V, 125A, 25kA for 1s, Aluminum Busbars & SMC Busbar supports to be provided in every 250mm interval.Total Number of Outgoings Feeders - 4 Nos 6 stage automatic power factor control relay as required. ( No. of banks to be made suitable by paralleling any two banks ) With Auto Manual Change Over Switches One Number (1) Outgoing feeders each consisting of following switch gears & components. 100 A TPN, MCB The coil voltage shall be 240V, single phase, 50Hz, AC Suitable rating capacitor duty Contactor including with heavyduty, MIXED DI-ELECTRIC (MDXL) 25 kVAr TP capacitor with internal wiring, fuses etc, complete as required with ON / OFF Push button etc. Three Number (3) Outgoing feeders each consisting of following switch gears & components. 32A, TPN, MCB The coil voltage shall be 240V, single phase, 50Hz, AC Suitable rating capacitor duty Contactor including with heavyduty, MIXED DI-ELECTRIC (MDXL) 5kVAr TP capacitor with internal wiring, fuses etc, complete as required with ON / OFF Push button etc. Rate to be quoted for Supply & Labour.
Electrical (CAPACITOR CONTROL PANEL ( 40 KVAR)) Supply
Electrical (CAPACITOR CONTROL PANEL ( 40 KVAR)) Labour
Electrical (DG CHANGE OVER PANEL) Supply
Electrical (DG CHANGE OVER PANEL) Labour
Supply and installation of 600mmx600mmx3.15mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, SFRC cover with frame - 20 tone capacity heavy duty,GI class 'B' watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc, CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 2.5 meter depth and back filling. ( value of earth resistance should be less than 1 ohm ). (For Generator Earthing) Rate to be quoted for Supply & Labour.
Electrical (EARTHING) Supply
Electrical (EARTHING) Labour.
Supply and installation of 50mm dia,B class GI pipe electrode earth station conforming to IS 3043-1987/NEC/IEE complete with brick mansonry chamber, CI cover, CI frame ,GI watering funnel with 20G GI wire mesh etc, The CI cover frame/ chamber shall be of 450mm x 450mm x 300mm size. CI manhole cover with frame shall be painted with bitumastic paint,identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal & common salt around electrode including digging of pit up to permanent moisture level but not less than 3.5 mtr depth and back filling. (Escalator- 4 Nos & Panel- 1 No) Rate to be quoted for Supply & Labour.
Electrical (GI pipe electrode earth station) Supply
Electrical (GI pipe electrode earth station) Labour.
Supply and clamping GI strips of the following sizes on surface of wall/trench/cable tray etc using using bolts, nuts, washer, welding etc as required. 25x3mm GI strip(For Generator) Rate to be quoted for Supply & Labour.
Electrical (25x3mm GI strips) Supply
Electrical (25x3mm GI strips) Labour
Supply, laying/fixing of earthing conductor of CU flat /wires jointing as per IS; 3043/87 in trench walls pulling through pipes etc as required) Copper wire No.8 SWG (For Escalators) & Copper wire No.6 SWG ( For panels) Rate to be quoted for Supply & Labour.
Electrical (Copper wire No.8 SWG (for Escalator) Supply
Electrical (Copper wire No.8 SWG (for Escalator) Labour
Electrical (Copper wire No.6 SWG (for Escalator) Supply
Electrical (Copper wire No.6 SWG (for Escalator) Labour
Supplying and laying the following XLPE insulated PVC sheathed armoured 1.1KV grade Aluminium conductor cable conforming IS: 1554 (Part-I) in cable trenches or on concrete wall or through pipes as per specifications, including providing of cable route markers in every 50M and at all strategic turning/diversion points etc. Necessary clamping should be provided while burying cables in prepared trenches etc. as instructed by the Site Engineer, 3.5 x 120 Sq mm. Al cable (incoming cables) & 3.5 x 50 Sq.mm. Al cable (incoming cable for Escalators) 3 x 4 Sq.mm. Al cable (Light loads) 4 x 25 Sq.mm. Al cable (V.D.B incoming cable) & Cable route marker (Refer 4.1) Rate to be quoted for Supply & Labour.
Electrical (a) 3.50x120 Sqmm AI cable (incoming cables)) Supply
Electrical (a) 3.50x120 Sqmm AI cable (incoming cables)) Labour
Electrical (b) 3.50x50 Sqmm AI cable (incoming cables for Escalators)) Supply
Electrical (b) 3.50x50 Sqmm AI cable (incoming cables for Escalators)) Labour
Electrical (c) 3x4 Sqmm AI cable (Light Loads) Supply
Electrical (c) 3x4 Sqmm AI cable (Light Loads) Labour
Electrical (d) 3x6 Sqmm AI cable (Pathway Surface Mounted Lights) Supply
Electrical (d) 3x6 Sqmm AI cable (Pathway Surface Mounted Lights) Labour
Electrical (e) 4x25 Sqmm AI cable (V.D.B incomimg cable) Supply
Electrical (e) 4x25 Sqmm AI cable (V.D.B incomimg cable) Labour
Electrical (f) cable route marker Supply & Labour
supplying and terminating siemens type / tropdoor compression gland, Aluminium lugs, earth clamps for XLPE insulated and PVC sheathed armoured conductor cable 1.1kv grade and making end terminations suitable for 2/3/3.5/4 core cables of the following sizes as required 3.5 x 120 Sq mm. Al cable (incoming cables) 3.5 x 50 Sq.mm. Al cable (incoming cable for Escalators) 3 x 4 Sq.mm. Al cable (Light loads) 4 x 6 Sq.mm. Al cable (Escalator lighting loads) 4 x 25 Sq.mm. Al cable (V.D.B incoming cable) Rate to be quoted for Supply & Labour.
Electrical (a) 3.50x120 Sqmm AI cable (incoming cables)) Supply
Electrical (a) 3.50x120 Sqmm AI cable (incoming cables)) Labour
Electrical (b) 3.50x50 Sqmm AI cable (incoming cables for Escalators)) Supply
Electrical (b) 3.50x50 Sqmm AI cable (incoming cables for Escalators)) Labour
Electrical (c) 3x4 Sqmm AI cable (Light Loads) Supply
Electrical (c) 3x4 Sqmm AI cable (Light Loads) Labour
Electrical (d) 4x6 Sqmm AI cable (Pathway Surface Mounted Lights) Supply
Electrical (d) 4x6 Sqmm AI cable (Pathway Surface Mounted Lights) Labour
Electrical (e) 4x25 Sqmm AI cable (V.D.B incomimg cable) Supply
Electrical (e) 4x25 Sqmm AI cable (V.D.B incomimg cable) Labour
Supplying and fixing of the following way factory made single/three pole and neutral, sheet steel, RCCB Flexy distribution board enclosure, double shuttered on surface /recess complete with tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, cable end box, including painting, earthing etc as required. (IP 42) in recess/in surface including cutting holes on the wall making good the damage colour cleaning etc. as required. The rate should include cost of materials required for DB dressing like cable mount, using proper lugs for incoming and outgoing cable , cable ties, black tape, black buttons, end ferrules, stickers etc., complete. Three phase 4 tier- IP 42 protection metal door Flexy DB (4row of 13 modules) Rate to be quoted for Supply & Labour.
Electrical (FLEXY DISTRIBUTION BOARD) Supply
Electrical (FLEXY DISTRIBUTION BOARD) Labour
Supplying & fixing the following rating miniature circuit breaker of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. 63A 30mA FP RCCB Rate to be quoted for Supply & Labour.
Electrical (Residual Current Circuit Breaker) Supply
Electrical (Residual Current Circuit Breaker) Labour
Supplying & fixing the following rating Power contactors of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. TP 40A power contactor Rate to be quoted for Supply & Labour.
Electrical (Power contactors) Supply
Electrical (Power contactors) Labour
Supply, testing, installation and commissioning of digital timer switch housed in a suitable factory made M.S box with moulded front plate including earthing the box,3 plate ceiling rose etc. complete with necessary accessories like screws, nuts, internal wiring etc Multi functional digital (Alpharex D22) Additional Accessories (Data key for digital switches and USB port for digital time switches) Rate to be quoted for Supply & Labour.
Electrical (Digital timer switch) Supply
Electrical (Digital timer switch) Labour
Supplying & fixing the following rating miniature circuit breaker of following poles in existing Flexy DB complete with connections, testing and commissioning etc as required. (6-32)A SP MCB (Light loads) Rate to be quoted for Supply & Labour.
Electrical (Miniature Circuit Breaker) Supply
Electrical (Miniature Circuit Breaker) Labour
Supplying & fixing the following rating miniature circuit breaker of following poles in existing VDB complete with connections, testing and commissioning etc as required. 100A FP MCB isolator
Electrical (Miniature Circuit Breaker Isolator (Escalator incomer)) Supply
Electrical (Miniature Circuit Breaker Isolator (Escalator incomer)) Labour
Supplying & fixing the following rating miniature circuit breaker of following poles in existing VDB complete with connections, testing and commissioning etc as required. (6-32)A MCB
Electrical (Miniature Circuit Breaker (Pathway lights)) Supply
Electrical (Miniature Circuit Breaker (Pathway lights)) Labour
Supplying & fixing the following rating miniature circuit breaker of following poles in existing VDB complete with connections, testing and commissioning etc as required. (Sky walk, ramp & foot over bridge) (6-32)A MCB
Electrical (Miniature Circuit Breaker with metallic enclosure) Supply
Electrical (Miniature Circuit Breaker with metallic enclosure) Labour
Supplying all materials and wiring for light points/exhaust fan using 3 runs of 1.5mm² 650V grade PVC insulated copper conductor single core FRLS wires run continously as per IS through ISI grade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M.S box with moulded front plate including earthing the box,3 plate ceiling rose etc. complete as required.( The earth wire shall be green colour)
Electrical (Wiring Light / exhaust fan point) Supply
Electrical (Wiring Light / exhaust fan point) Labour
Supplying all materials and wiring for 6A plug points in combined positions using 1.5 sq.mm PVC insulated copper conductor single core FRLS wire run continously as per IS through ISI grade medium gauge rigid PVC conduits concealed in wall / slab etc, complete with necessary accessories and fixing 6A modular type 3 pin shuttered plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factory built MS box. Giving connections, earthing etc complete as required. This circuit shall be looped to the lighting circuit.
Electrical (6A Plug points - combined position)) Supply
Electrical (6A Plug points - combined position)) Labour
Supply and providing 16 / 6A combined modular type power plug socket (shuttered) controlled with 16A modular type switch, mounted on a suitable factory built MS box with earthing facility, giving interconnections etc as required.
Electrical (16/ 6A Power plug points) Supply
Electrical (16/ 6A Power plug points) Labour
Supply and Providing of (telephone junction box) Epoxy coated MS Enclousre with KRONE Make SS Backmount Frame & Disconnection Module mounted on the wall including all accessories 10 Pair Ms Enclosure With Bmf & DCM
Electrical (Telephone System) Supply
Electrical (Telephone System) Labour
Supply and laying of following pair 0.5 mm² telephone cable through existing conduit . 2 pair cables
Electrical (Telephone System) Supply
Electrical (Telephone System) Labour
Supply and wiring of 3 runs of 1.5 sqmm PVC insulated fine stranded FRLS cu wire drawn through suitable size ISI grade medium PVC conduit including all accessories as required.( conduit separate item )(For circuit mains etc)(The earth wire shall be of green colour)
Electrical (3Runs 1.5 sq.mm. Cu wire) Supply
Electrical (3Runs 1.5 sq.mm. Cu wire) Labour
Supply and wiring 3 runs of 2.5sq.mm PVC insulated fine stranded FRLS copper wire drawn through 25mm ISI grade rigid/flexible PVC conduits including all accessories as required (For 15A/Gyeser points)(The earth wire shall be of green colour)
Electrical (3 Runs 2.5 sq.mm. Cu wire) Supply
Electrical (3 Runs 2.5 sq.mm. Cu wire) Labour
Supply and providing of 20 mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required.
Electrical (20mm PVC Conduit) Supply
Electrical (20mm PVC Conduit) Labour
Supply and providing of 25 mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required.
Electrical (25mm PVC Conduit) Supply
Electrical (25mm PVC Conduit) Labour
Supply and providing of 32mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required.
Electrical (32mm PVC Conduit) Supply
Electrical (32mm PVC Conduit) Labour
Supply and providing of 40mm electrical grade ISI heavy duty PVC conduit through wall, ceiling etc. including the supply of all accessorises required.
Electrical (40mm PVC Conduit) Supply
Electrical (40mm PVC Conduit) Labour
Supply and providing of 80dia electrical grade ISI Hot Dip galvanised MS conduit through wall, ceiling etc. including the supply of all accessorises required.
Electrical (80mm dia Hot Dip galvanised MS conduits) Supply
Electrical (80mm dia Hot Dip galvanised MS conduits) Labour
Supply and fixing of following surface mounted wall step light . die cast construction and UV stabilized polycarbonate diffuser luminaires of Philips/ Havels / GE make for ceiling including provision of suitable accessories for mounting of fittings, etc. all complete as per specifications and equivalent to Philips cat no. as per details given and direction of Engineer In-charge. (including accessories) Havels Cat. No. Endura Magnum 40W LED or Equivalent
Electrical (a) Havels cat. No Endura Magnum 40W LED or Equivalent) Supply
Electrical (a) Havels cat. No Endura Magnum 40W LED or Equivalent) Labour
Electrical (b) Philips cat. No MIROLTA (TMS205 1xTL40W) Supply
Electrical (b) Philips cat. No MIROLTA (TMS205 1xTL40W) Labour
Supply & fixing of Bollard light fixture with suitable mounting base along with necessary accessories, including excavation upto required depth, giving connections and back filling etc Philips Cat. No. FGC 100 1XPLS9W
Electrical (BOLLARD LIGHTS) Supply
Electrical (BOLLARD LIGHTS) Labour
Supplying, laying and joining hume pipes of ISI mark joining specials in existing trenches or ground upto a depth of 1.0 m joining with solvent cement, testing the line etc as required as approved by the site in charge. (Excavation different item) 110mm
Electrical (a) Hume Pipe 100mm) Supply
Electrical (a) Hume Pipe 100mm) Labour
Electrical (b) Hume Pipe 60mm) Supply
Electrical (b) Hume Pipe 60mm) Labour
Supply, erection of following sizes GI perferated type cable rack system made out of sheet steel folded to required shape with adequate number of supports.
Electrical (GI perferated type cable) Supply
Electrical (GI perferated type cable) Labour
Housekeeping of FOB Premises Women (365 days x 2 years) x 2 Nos Mazdoor II
O& M Maintenance Cost
Housekeeping of FOB Premises Maintenance Supervisor (365 days x 2 years) x 2 Nos TA II
O& M Maintenance Cost for 3 Years
Housekeeping of FOB Security Guards 1 Nos. considering 3 shift per day Mazdoor II
O& M Maintenance Cost
Annual Maintanance of public service Light duty Escalators / Travellators outdoor type(GS8000-NX) for the period of 2 years from the date of commisioning inclusive of First year Free Maintanance Period.A) Routine Maintenance during regular working hours which covers i) Examine the Equipment at regular intervals for 6month service and 6 month service visit with the government regulations existing at the date of this agreement, ii) Clean, adjust, topup oil & grease parts of the equipment as required to maintain the performance of the equipment as close as possible as it was first installed, iii) Report & make recommendations(as may be required) to the owner for any parts repair or replacement as deem necessary, iv) Repair/replacement of parts, components, specifically for equipment control & operation due to fair wear and tear(Materials included) .B) Emergency Call Back Services at any time between regular examinations upon the request of the owner to trouble shoot the Equipment which includes, i) Dispatch as soon as reasonably and practically possible, a trained person to attend any breakdown of the equipment, ii) Use its endeavors to restore the Equipment to operational service without charge, provided always that such restoration would not involve the repair or replacement of parts that arrises from misuse or the negligance of any party, iii) Where any repair or replacement is required during the emergency call back service, such services will be rendered during regular working hours. Other services likei) check for proper operation,abnormal noise, temperature,dust and wear, ii) Clean dust,excess oil,dirt accumulation,carbon deposits, iii) Adjust to compensate gaps due to wear, equalize tension, clearences to within tolerace, Tighten loose connections, iv) Lubricate moving parts and protect from corrosion & v) Repair/Replace of parts like Fuses,relays, PCBs, button & Indicator, switches,wires, terminals, transformers, motor, brake,guides, rollers,bearings,gears , valves, Gear oil, Chain Lubrication oil Etc.,/however any defect shall be rectified within 12 hrs time (Payment will be made as per actual maintenance work done)
O& M Maintenance Cost Escalator 1
O& M Maintenance Cost Escalator 2
Annual Maintanance of public service 13 persons STAINLESS STEEL LIFT / ELEVATORS for the period of 2 years from the date of commisioning inclusive of First year Free Maintanance Period. A) Routine Maintenance during regular working hours B) Emergency Call Back Services at any time between regular examinations upon the request of the owner to trouble shoot the Equipment which includes, (Payment will be made as per actual maintenance work done)
O& M Maintenance Cost Lift 1
Supply of Fuel (Diesel) for running of 125KVA Diesel Generator for period of 2 years to generate power for uninterupted running of Escalators & all other electrical equipments incase of any power shutdown (200 liters/Month),(the consumption will be paid based on actual quantity).
O& M Maintenance 125KVA Diesel Generator Fuel cost
Annual Maintanance of 125 KVA Diesel Generator for the period of 2 years from the date of commisioning inclusive of First year Free Maintanance Period. .All maintenance and repairs as per periodic maintenance chart for Engine in regular use which covers,A) Engine a) Every 50 service hours or every month visit for checking i) Draining water from the fuel tank and fuel pre filter, ii) Retightening the belts,clamps,mounting bolts & nuts, iii) Topup oil & coolant if required, iv) Stop any leakages if observed & v) Check & Topup if required Battery Electrolyte level.b) Every 500 service hours or every six months visit for checking i) Changing engine oil, oil filters, bypass oil filter and fuel filters, ii) Changing governor oil filter & iii) Change coolant filter. c) Every 1500 hours visit for checking i) Inspection of V-belt and adjustment of belt tension, ii) Check and adjust valve clearence & iii) Check sir cleaner restriction and cleanliness. d) Every 2400 service hours visit for checking i) Changing V-belt, ii) Inspection of fuel control linkage ball joints, iii) Inspection and adjustment of fuel injection timing if required, iv) Changing fuel injection timing if required, v) Checking movement of the rack(during operation) of the fuel injection pump(including the governor). B) Value added services like training on maintenance and operations of the DG set to operating staff once in a year, Safety & caution indicators & Reporting once in 6 months which include a)Details of AMC b)Details of check done C) A comment/suggestion given by a senior service engineer after inspecting and looking i9nto the earlier report of AMC visits to the spot any trend or any indications of possible failure/breakdowns d)Suggestions to enhance the engine life & anyother in all respect for the regular maintenance,however any defect shall be rectified within 12 hrs time.(Payment will be made as per actual maintenance work done)
O& M Maintenance cost 125KVA Diesel Generator
Cost of consumption of electricity for escalator & lightings (the consumption will be paid based on the actuals)
O& M Maintenance cost Electrical Panel & Maintanance Control
Electrical Panel board & Maintanence control engineer(10days/month,based on the actuals)
O& M Maintenance cost Electrical Panel & Maintanance Control
Electrical Supervisor (1 Nos per Day)
O& M Maintenance cost Electrical Panel & Maintanance Control
Cost for replacement of fused bulbs , replacement of damaged fittings , repair and maintenance of wiring, and electrical fittings etc complete.(the consumption will be paid based on actuals)
O& M Maintenance cost Electrical Panel & Maintanance Control
Calculation of SubTotal, GST and Total carried out by system automatically
Sub Total Amount for above all items
GST 18% for the above SubTotal Amount
SD INFRA PRIVATE LIMITED (BID ID -1434462)
Omsakthiconstructions (BID ID -1433548)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid