Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹20.9 L+₹58,843 (2.90%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹21.1 L+₹80,975 (3.99%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹21.2 L+₹89,217 (4.39%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹21.5 L+₹1.2 L (6.06%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹18.4 L
EMD Value
₹36,880
Closing Date
14 May 2022, 6:00 pmClosed
GE (AF) Mohanbari
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarh Assam 786012
REWIRING AND REPLACEMENT OF FANS LIGHTS MAINS AND SWITCH BOARDS IN CERTAIN SMQs OMQs AND LIVING IN BILLETS AT AFS MOHANBARI UNDER GE AF MOHANBARI
2022_MES_519415_1
8001/359/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Mohanbari
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Mohanbari
₹36,880
28 Jul 2022
22 Apr 2022
17 May 2022
22 Apr 2022
14 May 2022
7 May 2022
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for trenches for laying underground cables, pole stay assemblies, but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for trenches for laying GI pipes for cable protection, but not exceeding 10 sqm on plan getting out in hard / dence soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed by Engineer-in-charge.
Removal of excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point
Supply and Laying dry sand as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete all as specified and as directed by Engineer-in-Charge. Note : Only punned down thickness of sand shall be measured for payment.
Material and labour for well burnt bricks sub class 'B' of size 230 x 115 x 75 mm having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection including taking out of old one and removing from site, complete all as specified and as directed by Engineer-in-Charge.
Taking down copper / aluminium point wiring (light, fan, bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc and removing materials from site for taking credit and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed by Engineer-in-charge.
Taking down carefully ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store and refixing back to its original position and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed by Engineer-in-charge. Note: (Any minor repairs if required during execution of this item, shall be made by the contractor without any extra cost to the department)
Material and labour for concealed point wiring for one light/fan/bell point controlled by one, one way switch using 2 x 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover and 1 x 1.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed point wiring for one light point controlled by two Nos, two way switch using 2 x 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover and 1 x 1.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed point wiring for one 05 amps socket controlled by one way switch on same board circuit using 2 x 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover and 1 x 1.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed point wiring for one 05 amps switch socket combination on independent board using 2 x 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover and 1 x 1.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed point wiring for one 15 Amp switch socket combination on independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including sunk cast pressed steel terminal box made out of MS sheet for mounting of fittings like switch socket combination with 3 mm thick hylum laminated sheet cover and 2.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for concealed point wiring for metal clad socket for geyser power point using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduit and fittings of medium grade, and 4.0 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
M&L for concealed submain wiring with 2x 1.5 Sqmm, PVC insulating unsheathed copper conductor cable,multistranded,single core, FRLS type,1100 volts grade alongwith 1X1.5 sqmm PVC insulated unsheathed copper conductor cable ,multistandard ,single core, FRLS type,1100 volts grade for continious earth wire complete drawn through and including PVC concealed conduit medium grade of suitble size with all fitting such as bend,elbow,tee,joint, including taking down of old one, complete all as specified and directed by engineer in charge. (Note: Copper conductor 3 runs of 1.5 sqmm and one run of pvc conduit shall be measured as one length)
M&L for concealed submain wiring with 2x 6.0 Sqmm, PVC insulating unsheathed copper conductor cable,multistranded,single core, FRLS type,1100 volts grade alongwith 1X6.0 sqmm PVC insulated unsheathed copper conductor cable ,multistandard ,single core, FRLS type,1100 volts grade for continious earth wire complete drawn through and including PVC concealed conduit medium grade of suitble size with all fitting such as bend,elbow,tee,joint, including taking down of old one, complete all as specified and directed by engineer in charge. (Note: Copper conductor 3 runs of 6 sqmm and one run of pvc conduit shall be measured as one length) COMMON NOTE FOR BOQ ITEM NO 9 to 16:- Quoted rates shall be included for cutting and chasing to the surface and making good to match the same with existing surfaces.
Supply and fix switch piano flush type, single pole , 5/6 Amps, one way 230 V, 50 Hz, complete all as specified and directed by Engineer-in-charge.
Supply and fix switch piano flush type, 2 way 5/6 amp 230 V, 50 Hz complete all as specified and directed by Engineer-in-charge.
Supply and fix bell push switch piano flush type, 1 way 5/6 amp 230 V, 50 Hz complete all as specified and directed by Engineer-in-charge.
Supply and fix socket outlet 5 amp, 5 pin piano flush type, 230 V, 50 Hz complete all as specified and directed by Engineer-in-charge.
Supply and fix switch socket combination multipurpose type 6 pin 5/15 Amps, piano flush type 230/240 V complete all as specified and directed by Engineer-in-charge.
Supply and fix switch socket combination, multipurpose type 5 pin , 5 Amps piano flush type 240 V complete all as specified and directed by Engineer-in-charge.
Supply and fix PVC / Polycarbonate ceiling rose (ISI marked) surface bakelite 65 mm x 50 mm three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed by Engineer-in-charge.
Supply and fix stepped type electronic fan regulator piano flush type 240 Volts, ISI marked suitable for 1200/1400mm sweep ceiling fan complete all as specified and directed by Engineer-in-charge.
Supply and fix calling bell, ding dong type AC, 230 volts, single pole complete all as specified and directed by Engineer-in-charge.
Supply and fix lamp holder, PVC / Polycarbonate type with cord grip cap 230 Volts AC suitable for and including LED bulb of 5 Watts, complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs concealed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
Supply and fix concealed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Tripple pole and neutral 240 V, 4 ways with 200 Amps rated bus bar vertical/horizontal type including taking down old one and making good the disturbed surface, complete all as specified and directed by Engineer-in-charge.
Supply and fix metal clad sheet metal concealed enclosure SPN 20 Amps, 230 volts, AC with two pin and earth plug & socket alongwith one SP MCB 20 Amps, 230 Volts, C-curve type including taking down old one and making good the disturbed surface, complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs MCB TPN 40-63 Amps, 230 V, C curve, 10KA complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs MCB SPN 32 Amps, 230 V, C curve, 10KA complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs MCB SP 10- 32 Amps, 230 V, C curve, 10KA complete all as specified and directed by Engineer-in-charge.
Supply and fix LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old one, complete all as specified and directed by Engineer-in-charge. Make: Crompton Cat Part No LDL-20-CDL or Philips Cat Part No BN021C LED020S CW GR S2 or Havells Cat Part No LHEXARP7IN1W020-pk1
Supply and fix LED lights fitting mirror type with high out put diffuser 2 feet, 10 watt, 220v AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old one, complete all as specified and directed by Engineer-in-charge. Make: Crompton Cat Part No LDL-10-CDL or Philips Cat Part No BN021C LED010S 6500 PSU GR S1 or Havells Cat Part No LHEXACP7IN1W010
Supply and fix LED building security light / street light fitting 30 watt 230 V, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal managment in multiple optics complete with IP 65/66 protection including taking down old one, complete all as specified and directed by Engineer-in-charge. Make: Crompton Cat Part No LSTS-30-CDL-M or Philips Cat Part No BRP046 LED30 CW MR S1 PSU GR or Havells Cat Part No LHEXAYP7PN6K030
Supply and fix in repairs building security light bracket made out of GI pipe (light grade) 25 mm dia 1.5 meter long bent to required shape as directed and fixed to wall, complete with two coats of aluminium paint over a coat of red oxide primer including clamps and nut, bolts and washers, complete all as specified and directed by Engineer-in-charge.
Supplying and laying in repairs 40 mm bore, galvanised iron pipe, light grade for cable protection, complete with all fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and lay in repairs LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured ,electric power cable (heavy duty) 1100 volts grade with standed aluminium conductor of sizes 3.5 core 35 sqm in trenches/pipe/poles and connecting with all accessories, complete all as specified and directed by Engineer in charge.
M&L earthing in repairs / replacement complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary earth work in any type of soil ,returning filling in and removal of surplus soil ,concrete pit in PCC (1:3:6) type C1 ,pre cast RCC 1:2:4 type B1 cover slab 54cm*54cm* reinforced with 8mm dia bar TMT @ 150mm c/c both ways with one handle for lifting made out 8 mm dia ms bar with wire mesh funnel,20 mm GI tubeing medium grade for watering and 40 mm GI tubing light grade for protection all as shown in electrical plate No. 3 connected to earthing test point all as specified and directed by engineer in charge.
D B Construction
M/S RK Trading
KP GHOSH AND CO
S K ENTERPRISE
M/S P R SINGH AND SONS
R K CHAKRABORTY AND CO
M/s Sashi Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .