Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.7 LAccepted-Finance 15 32 NEAR FLYOVER ROAD NO 32 PUNJABI BAGH EAST WEST DELHI DELHI 110026 | DELHI | WEST DELHI | DELHI | 110026 | L1 | Accepted-Finance Due to quoted lowest rates amount | |
| 2 | L2₹1.0 Cr+₹16.6 L (19.3%)Rejected-Finance | L2 | Rejected-Finance Due to not quoted lowest rates amount | |
| 3 | L3₹1.2 Cr+₹33.3 L (38.8%)Rejected-Finance | L3 | Rejected-Finance Due to not quoted lowest rates amount |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
18 Aug 2022, 3:00 pmClosed
Manager Electrical
Manager Elect. ITPO at Pragati Maidan New Delhi
Comprehensive maintenance and Operation contract of Electrical , Mechanical installations of substation no. III and IX at Pragati Maidan New Delhi for the period of two years.
2022_ITPO_706315_1
169-ITPO(2)E-E/22-23/71
Open Tender
Electrical Works
Item Rate
730 days
pragati maidan new delhi
As per NIT
7 documents required · 7 mandatory
₹1,180
Yes
ITPO
₹2.2 L
Yes
2 Nov 2022
11 Aug 2022
19 Aug 2022
11 Aug 2022
18 Aug 2022
11 Aug 2022
Amount
Comprehensive maintenance of all the Electrical & Mechanical installations of 11kv/433v substation No3 (Near Hall No12) at Pragati Maidan New Delhi & connected switch rooms complete with all accessories like transformers, Bus bars, Circuit breakers, Switches, MCCBs, capacitor bank along with all the connected H.T & L.T Cables between BSES and substation, substation to substation, Substation to switch room and switch room to halls, including servicing, dehydration including providing extra Transformer oil if required, calibration of relays, earth and insulation tests, repairs, routine, preventive maintenance, attending complaints/ faults/ breakdown and taking rectification actions ensuring serviceability/ satisfactory working condition of the systems, maintenance of records/ documentation etc. as per the detailed specifications by providing and replacing any defective parts(excluding rewinding of the transformer, replacement of cables)as per terms and conditions attached by using qualified, experienced and trained, skilled workers etc. as required.
Comprehensive maintenance of all the Electrical & Mechanical installations of 11kv/433v substation No9 (Near Gate No1) at Pragati Maidan New Delhi & connected switch rooms complete with all accessories like transformers, Bus bars, Circuit breakers, Switches, MCCBs, capacitor bank along with all the connected H.T & L.T Cables between BSES and substation, substation to substation, Substation to switch room and switch room to halls, including servicing, dehydration including providing extra Transformer oil if required, calibration of relays, earth and insulation tests, repairs, routine, preventive maintenance, attending complaints/ faults/ breakdown and taking rectification actions ensuring serviceability/ satisfactory working condition of the systems, maintenance of records/ documentation etc. as per the detailed specifications by providing and replacing any defective parts(excluding rewinding of the transformer, replacement of cables)as per terms and conditions attached by using qualified, experienced and trained, skilled workers etc. as required.
Round the clock Operation on all days of all the Electrical & Mechanical installations in 11kv/433v Substations no. III & connected switch rooms complete with all accessories like transformers, DG sets, LT,HT Panels, APFC panels Bus bars, Circuit breakers, Switches, MCCBs, all the connected H.T & L.T Cables between BSES and substation, substation to substation and Substation to switch room, by using following man power:- a) Substation operator= 3 Nos (One operator in each shift of 8Hrs at substations no. III for round the clock operation) b) Khallasi = 3 Nos (One Khallasi in each shift of 8Hrs at substations no. III for round the clock operation) One Job
Routine, preventive maintenance and Operation of all the internal and external Electrical & Mechanical installations connected to substation no. 3 & 9 at ITPO campus pragati maidan i/c of toilets blocks and connected switch rooms, street lights, complete with tower, pole, high mast, foundation, fittings, distribution boxes, tubes, bulbs, Bus trunking, Bus bars, Switches, MCCBs, Feeder pillars, distribution boards, MCBs, Isolator, air curtains,hand-driers, switch-socket & all type of light fittings & fans with their chokes, starter, igniters, capacitor along with all the connected wires, Cables connecting to switch room, hall feeder pillars, DBs, switch boards including operation, repairs & maintenance attending to complaints/ faults/ breakdown and taking rectification actions ensuring serviceability/ satisfactory working condition of the systems by providing and replacing wornout wires, HRC fuses, Switches, sockets, Plug tops, thimbles, cable glands, MCBs, MCCBs etc, preventive maintenance, maintenance of records/ documentation etc. as per terms and conditions on all days excluding weekly rest and holidays by providing following qualified, experienced and trained/ skilled workers etc. as required. (a) wireman – 2 nos. (for 8 hours shift 10am to 6pm) (b) khallasi – 2 nos. (for 8 hours shift 10am to 6pm) (Note: weekly rest for workmen shall be shifted during non-exhibition days) One Job
A) One Wireman
B) One Khallasi
Comprehensive maintenance of following DG sets back to back through OEM or their authorised agency including B check of engine, complete routine check of all Electrical and mechanical accessories like engine, AMF Panel, batteries, control switch gears, cable etc. including preventive maintenance, repairs & break down maintenance, attending complaints/ faults, taking rectification actions by providing and replacing all spare parts and Mobile oil, filters etc. if required including batteries to ensure serviceability/ satisfactory working condition of the systems, maintenance of records/ documentation etc. as required at Pragati Maidan New Delhi for the period of two years. A) 2x285KVA of Cummins make at Substation no.3
Supplying and filling of High speed Diesel oil in the DG sets tanks installed at various substations at Pragati Maidan complex complete with transportation and labour as and when required.
SITC of following rating 3 pole MCCB in the existing panel as required at Pragati Maidan, New Delhi (Make: ABB, L&T, Schneider, Siemens or equivalent).
(a) 100Amp, 30kA breaking capacity
(b) 200Amp, 36kA breaking capacity
(c ) 250Amp, 36kA breaking capacity
Supply and fixing of fire retardant electrical insulated flooring of 2.0 mm and 2.5 mm nominal thickness duly ISI marked and tested for breakdown strength, tensile/elongation, aging properties, insulation resistance, effects of acid, alkaline diesel and transformer oil, leakage current test, having min. width 1000 mm + 20mm. complete with providing all allied materials such as pu-resin, chemi bound (hardener), spl. PVC adhesive, liquid primer, sealing material, tapes of matching colour and design etc. as required (Make: VOLTMAT, Jyoti or equivalent).
(a) 2.0 mm thick suitable for class A upto 3.3 kv
(b) 2.5 mm thick suitable for class B upto 11 kv
Comprehensive service maintenance contract of existing 100kwp and 50kwp solar roof top power plants installed on roof top of hall no. 7 and hall no. 12 complete with cleaning of panels, maintenance & settings of inverter, earthlings, DC/AC distribution boards, all electrical panels and connecting cables along with monitoring of energy generation of plants etc. complete as required for the period of two years.
Shailendra & Das Co.
R K G ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .