| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹32.6 L+₹1.6 L (5.20%)Rejected-Finance ROOM NO D 290 PART III GALI NO 8 SHREE GANESH MURTHI NAGAR CUFFE PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹33.9 L+₹2.9 L (9.28%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 4 | L4₹36.6 L+₹5.6 L (18.1%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 5 | L5₹36.9 L+₹6.0 L (19.3%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
27 May 2024, 6:00 pmClosed
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF INTERNAL WIRING CEILING EXHAUST FAN WELCOME MAINTENANCE REPLACEMENT OF MODULAR FITTING AND FIXTURE AND OTHER ALLIED WORKS AT RASHI AREA BUILDING AT NAVY NAGAR COLABA MUMBAI
2024_MES_652798_1
8367/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹1 L
Yes
9 Jul 2024
7 May 2024
29 May 2024
7 May 2024
27 May 2024
21 May 2024
7 May 2024 - 27 May 2024
Amount
Taking down carefully copper/ aluminium point wiring i.e. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
M & L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm and quoted rate is included for this aspect.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
One bell point controlled by one push button
All as per item No 2.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm
S & F modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F Modular Socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with Socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with modular electric bell ding dong, AC, 230V single pole. Make:Crabtree/Anchor/Legrand
S & F modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed. Make : Crompton/Bajaj/Wipro.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC Gang box, screwless, with silver border of 8 module for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
All as per Item No- 20.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 20.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 20.00 above but of modular PVC Gang box, 2 module.
All as per Item No- 20.00 above but of modular PVC Gang box, 1 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 2 module.
S&F modular white cover plate with frame, 1 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including connection with ceiling rose.
Taking down unserviceable FTL/batten fittings with supply and fix LED integrated batten of 10 Watt 2ft LED give minimum output lumen 1150 lm, efficiency >110, CCT 4000/6500K, CRI >80, power factor >0.9, operating temperature 45 degree celcious, THD <20% of housing aluminium extrusion with LED dimension 603mmx22mmx36mm upto 50% energy saving.
Taking out any type of fitting bulkhead/FTL and S&F 10 watt linear LED batten, 2 feet, aluminium extruded channel, powder coated with diffuser for glare free light, inbult motion sensor prewired with 25% dimmer illuminiuos in ideal time with all accessories including two nos of PVC box of size 75x75x20mm for mounting light fittings complete.
S&F MCB DB SPN conforming to IP 43 - IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls.Make:-L&T/Legrand/Havells
Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt 'C' series complete all as specified. Make:-L&T/Legrand/Havells
Taking out Old U/S and S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt 'C' series complete all as specified. Make:-L&T/Legrand/Havells
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified. Make:- Crompton/Bajaj/Usha/Havells
Taking out unserviceable exhaust Fan and deposit to MES Store, supply and replacement with exhaust fan, Steel body 4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connecting with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified and directed. Make :- Havells/Crompton/Bajaj/Polycab/Usha.
Taking out & Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking out & Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down deteriorted louvers and supplying and fix new louvers fixed type made out of 1.6mm GI sheet with horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete by providing of fixing arrangement for louvers upto 5th floor of including rate all as specified and directed by Engr-in-Charge
S & F cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
S&F in relplacement with new cable PVC insulated three core over all PVC sheathed 2.5 Sqmm stranded copper conductor cable for connecion from DB to connector junction box for power supply to security light fittings drawn in PVC conduit not less than 20mm including taking out old one all as directed.
S & F junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
S&F street light bracket bend to shape made as required of 40mm dia 1.0 mtr long GI pipe light grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out old U/S one all as specified and as directed.
Taking out Old, U/s one Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Inspection / checking of serviceability for ceiling fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e 'S' hook, split pin, cotter pins, rubber bush, cpacitor, SWR etc) servicing the fan completely after removing of old grease from bearing and hanging it to its same loaction after complete assurence of any defects as specified inspecting fan for proper working, connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 all as specified and as directed by Engr-in-charge. Note (a) Complaint pertains to unserviceable Ceiling fan/Exhaust Fan/Energy Meter as given by the Engr-in-Charge shall be attended within 48hrs from the day of complaint assigned to the representative of the firm as directed by Engr-in-Charge upto the satisfactory level and on failing which the penality shall be imposed @ Rs 250/- per day per item of Schedule (BOQ) (b) The Contractor or the accredited representative of the firm shall report to the JE concerned at the E/M Complaint Cell i.e Sub Station No -07 and RS-1 Colaba resp for receiving the complaints at 0900 to 1000hrs daily excluding Sunday and Holiday.
DHARICHHAN ENTERPRISE
NOEL ENGINEERS
SHRI SAI ENTERPRISES
shubham construction
shree arihant constrution
AIRDOT ENGINEERING
Ashish Enterprises
AGRAWAL ASSOCIATES
Nayana Electric Corporation
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .