| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC BRAJALALCHAK P O DAKSHINCHAK HALDIA PURBA MEDINIPUR | HALDIA | PURBA MEDINIPUR | WEST BENGAL | 721657 | ₹1.9 L | L1 | Accepted-AOC Quoted lowest bid |
| 2 | L2₹1.9 L+₹4,081.67 (2.18%)Rejected-Finance | ₹1.9 L+₹4,081.67 (2.18%) | L2 | Rejected-Finance Quoted 2nd lowest bidder |
| 3 | L3₹2.0 L+₹16,028.28 (8.57%)Rejected-Finance 5 9 35 HAZARHAT KALITALALANE HOWRAH 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | ₹2.0 L+₹16,028.28 (8.57%) | L3 | Rejected-Finance Quoted 3rd lowest bidder |
| 4 | Rejected-Technical 63 S MAHANIRBAN ROAD KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | - | - | Rejected-Technical Not recommended |
| Sl No | Description | Qty | Unit | Electro Engineering Concern L2 | S. D. Construction L3 | Acropola L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, delivery including transportation of 12 M Height Hot Dipped Galvanized (BS EN ISO: 1461 2009) coated, hot rolled Sheet of non-structural alloy 3.0 mm thick (BSEN 10025) Octagonal Mini-mast (single section) Bottom Dia 240 mm and Top Dia 90 mm with monkey climbing arrangement and 1 no Full Moon Bracket suitable to mount 6 nos. of non integral flood light fittings (with luminaries mounting plate and provision of passing wire) along with GI nut bolts, (IS 1367) in house Terminal arrangement with cover for cable loop-in and loop-out. The rate should include testing at your works. (Make: Bajaj/Utkarsh/Transrail/Valmont/Subham Pole) | 1 | No. | 60,250 ₹60,250 | 62,500 ₹62,500 | 60,000 ₹60,000 Lowest |
| 2.00 | Preparation of RCC foundation of 550 mm dia and 1800 mm height (1500 mm below the Ground Level and 300 mm above the Ground Level) with required rod, cement, chips and sand etc. at the ratio 1:1:5:3 with ground bolt 4 nos for fixing the 10Mtr Height G.I Octagonal pole (excluding supply and delivery of Nut Bolts). | 1 | No | 8,100 ₹8,100 | 8,200 ₹8,200 | 8,000 ₹8,000 Lowest |
| 3.00 | Installation of 12 Mtr long GI Octagonal Mini Mast Pole with modern engineering practice (excluding the cost of RCC Foundation) including hydra charge and skilled technician. | 1 | No. | 5,750 ₹5,750 | 5,800 ₹5,800 | 5,500 ₹5,500 Lowest |
| 4.00 | Supply, drawing and Connection of luminaries with 3C X 2.5 Sqmm pvc insulated FR copper conductor through 10 mtr. Poles from looping box to light fittings as required. (Considering 12 mtr. Wire) . [ Havells/Fimolex/Polycab/Gloster/ KEI] | 1 | No. | 1,350 ₹1,350 Lowest | 1,400 ₹1,400 | 1,350 ₹1,350 Lowest |
| 5.00 | Fixing only Flood light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. | 3 | No. | 560 ₹1,680 | 580 ₹1,740 | 555 ₹1,665 Lowest |
| 6.00 | Supply and fixing of SPMCB "C" Curve 1-4 Amp with ISI marked to be placed on a din channel of Pole and connection with Terminal connector at the suitable location of the pole.(Legrand) | 1 | No. | 360 ₹360 | 380 ₹380 | 345 ₹345 Lowest |
| 7.00 | Supply and delivery of 1.1 KV grade 2 C X 10 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1. The cable should have ISI mark. [Havells/Polycab/Gloster/ KEI] | 96 | Mtr | 250 ₹24,000 Lowest | 300 ₹28,800 | 250 ₹24,000 Lowest |
| 8.00 | Lifting of the running Under Ground Cable coming to the looping cable Box upto the top of the muffing above the top of the ground level by drawing through 40 mm dia rigid pvc pipe of superior Quality and tiding the same by no 10 SWG G I wire with the pole including supply of pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 mtrs/run X 2 runs per pole). | 1 | No. | 240 ₹240 Lowest | 300 ₹300 | 240 ₹240 Lowest |
| 9.00 | Supply of HDPE Plb Duct pipe of size 32/26 mm. | 80 | RM | 90 ₹7,200 | 95 ₹7,600 | 85 ₹6,800 Lowest |
| 10.00 | Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. (c) 40 mm dia | 12 | Mtr. | 265 ₹3,180 | 280 ₹3,360 | 240 ₹2,880 Lowest |
Tender Value
₹1.9 L
EMD Value
₹3,850
Closing Date
13 Mar 2026, 2:30 pmClosed
CEO HDA
Office of the Chief Executive Officer Haldia Development Authority City Centre P.O. Debhog Haldia 721657 Dist Purba Medinipur
Supply and Installation of additional 1(One) No. 12 Mtr Mini Mast with LED Flood Lights for Illumination of Tamluk Raj Moydan under Tamralipta Municipality.
2026_HDA_1017784_1
34/HDA/EC-ELECT/2025 2026
Open Tender
ELECTRICAL WORKS M/R
Item Rate
90 days
Haldia Development Authority City Centre, Debhog
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3,850
HDA HALDIA
14 Aug 2026
5 Mar 2026
16 Mar 2026
6 Mar 2026
13 Mar 2026
10 Mar 2026
9 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, delivery including transportation of 12 M Height Hot Dipped Galvanized (BS EN ISO: 1461 2009) coated, hot rolled Sheet of non-structural alloy 3.0 mm thick (BSEN 10025) Octagonal Mini-mast (single section) Bottom Dia 240 mm and Top Dia 90 mm with monkey climbing arrangement and 1 no Full Moon Bracket suitable to mount 6 nos. of non integral flood light fittings (with luminaries mounting plate and provision of passing wire) along with GI nut bolts, (IS 1367) in house Terminal arrangement with cover for cable loop-in and loop-out. The rate should include testing at your works. (Make: Bajaj/Utkarsh/Transrail/Valmont/Subham Pole) | 1 | No. | - | - |
| 2 | Preparation of RCC foundation of 550 mm dia and 1800 mm height (1500 mm below the Ground Level and 300 mm above the Ground Level) with required rod, cement, chips and sand etc. at the ratio 1:1:5:3 with ground bolt 4 nos for fixing the 10Mtr Height G.I Octagonal pole (excluding supply and delivery of Nut Bolts). | 1 | No | - | - |
| 3 | Installation of 12 Mtr long GI Octagonal Mini Mast Pole with modern engineering practice (excluding the cost of RCC Foundation) including hydra charge and skilled technician. | 1 | No. | - | - |
| 4 | Supply, drawing and Connection of luminaries with 3C X 2.5 Sqmm pvc insulated FR copper conductor through 10 mtr. Poles from looping box to light fittings as required. (Considering 12 mtr. Wire) . [ Havells/Fimolex/Polycab/Gloster/ KEI] | 1 | No. | - | - |
| 5 | Fixing only Flood light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. | 3 | No. | - | - |
| 6 | Supply and fixing of SPMCB "C" Curve 1-4 Amp with ISI marked to be placed on a din channel of Pole and connection with Terminal connector at the suitable location of the pole.(Legrand) | 1 | No. | - | - |
| 7 | Supply and delivery of 1.1 KV grade 2 C X 10 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1. The cable should have ISI mark. [Havells/Polycab/Gloster/ KEI] | 96 | Mtr | - | - |
| 8 | Lifting of the running Under Ground Cable coming to the looping cable Box upto the top of the muffing above the top of the ground level by drawing through 40 mm dia rigid pvc pipe of superior Quality and tiding the same by no 10 SWG G I wire with the pole including supply of pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 mtrs/run X 2 runs per pole). | 1 | No. | - | - |
| 9 | Supply of HDPE Plb Duct pipe of size 32/26 mm. | 80 | RM | - | - |
| 10 | Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. (c) 40 mm dia | 12 | Mtr. | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_2500851.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .