Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC | ₹4.0 Cr Quoted ₹4.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹4.4 Cr+₹30.3 L (7.47%)Rejected-Finance | ₹4.4 Cr+₹30.3 L (7.47%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹4.4 Cr+₹37.6 L (9.28%)Rejected-Finance | ₹4.4 Cr+₹37.6 L (9.28%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹4.5 Cr+₹49.1 L (12.1%)Rejected-Finance | ₹4.5 Cr+₹49.1 L (12.1%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹4.6 Cr+₹51.3 L (12.7%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹4.6 Cr+₹51.3 L (12.7%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹4.5 Cr
EMD Value
₹5.2 L
Closing Date
19 Nov 2022, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
PROVISION OF OTM ACCN FOR DIAGNOSIS SERVICES AND PHYSIOTHERAPY DEPT AT MH DEOLALI
2022_MES_548224_1
CA NO. CEPZ/DEO/TOKEN-32 OF 2022-23
Open Tender
Civil Works
Lump-sum
750 days
Deolali Nashik
Class A
Category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹2,000
GE Deolali
₹5.2 L
Yes
29 Dec 2022
27 Aug 2022
21 Nov 2022
27 Aug 2022
19 Nov 2022
5 Nov 2022
29 Aug 2022 - 13 Sept 2022
Amount
SCH 'A' PART-I: BUILDING/STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Construction of Block of Diagnostic services (Pathology lab & X-Ray Dept) and Physiotherapy department complete all as shown in drawings and as specified.
Construction of Septic tank for 150 users all as shown on drawing No. CEPZ/88/TD/17M sheet 2/4, 3/4 & 4/4 and as specified.
Construction of Soakage well of size 2.40 m dia and 4.50 m deep all as shown in drawing No. CEPZ/2019/TD/03 sheet ½ & 2/2 and as specified.
Total amount of Sch 'A' Part-II (Internal Water Supply)
Total amount of Sch 'A' Part-III (Internal Electrification)
Total amount of Sch 'A' Part-IV (Lightening Protection)
Total amount of Sch 'A' Part-V (Road, Path, Culvert and Hardstanding)
Total amount of Sch 'A' Part-VI (Area Drainage)
Total amount of Sch 'A' Part-VII (Sewage Disposal)
Total amount of Sch 'A' Part-VIII (External Water Supply)
Total amount of Sch 'A' Part-IX (External Electrification)
Total amount of Sch 'A' Part-X (Dismantling / Demolition)
Total amount of Sch 'A' Part-XI (Site Clearance, Excavation and Earthwork)
NOTE: Schedule ‘A’ Part II to XI items which are not Prepriced by MES are given in Sch 'A' Part-XII, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as "0.0" are for that purpose.
SCHEDULE 'A' PART-XII (MISC B/R AND E/M WORKS)
Supplying, installing, connecting, testing and commissioning Storage Water Cooler 80 litre capacity and cooling capacity 40 litres per hour, based on eco friendly gas R-134A including extending the drain out pipe to the nearest drain system, including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Makes: Blue Star / Usha / Voltas).
Supplying, installing, connecting, testing and commissioning Refrigerator electric driven (Single Phase) of capacity 195 to 200 litres, 220 volts, 50 Hz, BEE 5 Star rated based on eco friendly gas R-134A including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Makes: Blue Star / LG / Voltas / Godrej).
Supplying, installing, connecting, testing and commissioning Glass top Deep Freezer electric driven (Single Phase) of capacity 320 litres, 220 volts, 50 Hz, BEE 5 Star rated based on eco friendly gas R-134A including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Makes: Blue Star / LG / Voltas / Godrej).
Supplying, installing, connecting, testing and commissioning Hi wall Split AC unit electric driven of capacity 1.50 TR, 220 volts, 50 Hz, complete with cordless remote control unit and built in air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 based on and including eco friendly gas R-134A including connecting lead and suitable 3 pin plug top complete all as specified and directed. Makes as per Appendix 'C'.
Supplying, installing, connecting, testing and commissioning Water heater, storage type, steel body with copper inner tank and heating element upto 2 KW, electric driven of capacity 25 Litres, BEE 5 star rated, complete with all accessories such as safety valve, thermostate, NRV, connection place etc. including connecting lead and suitable 3 pin plug top complete as specified and directed. Makes as per Appendix 'C'.
S&F Bib cock with wall flange, 15 mm bore, cast copper alloy, chromium plated, fancy type long body, screwed down, screwed for iron pipe of brass ferrule, complete all as specified and directed. (Makes: Jaquar Cat No-FLR-5047N of equivalent model in makes as per Appendix 'C').
S&F Angular stop cock with wall flange, 15 mm bore, cast copper alloy, chromium plated, fancy type long body, screwed down, screwed for iron pipe of brass ferrule, complete all as specified and directed. (Makes: Jaquar Cat No-FLR-5053N of equivalent model in makes as per Appendix 'C').
S&F Soap dish, standard size, chromium plated, fancy type, fixed to plugs with CP brass screws, complete all as specified and directed.
S&F Lamp holder, PVC / polycarbonate type with back plate including LED lamp 5 watt of suitable colour, complete all as specified and directed.
S&F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose. complete all as specified and directed. (Makes: Philips Cat No. BN021C LED22S PSUCWGR or Havells Cat Part No. REGALBATTEN5UPTO1X20WDSBSWH or equivalent model in the makes given in Appendix 'C').
S&F LED light fittings out door type Building security light 25 W to 30 W fixture consisting of extruded aluminium extrusion housing with PC diffuser, LED fixture system wattage of 36 / 40W, 140V - 260V AC, system lumen output min 3960 lumen in 40W with 5700 -6500 K CCT with pf > 0.95, CRI >=80 and with = 10% THD, with min 2.5 KV surge protection in built and complete LED fixture with BIS R mark and R Registration no with and including bracket made of 40 mm dia GI tubing light grade bent to shape required including 2 Nos of flat iron clamps duly welded with nuts, bolts and washers etc, complete all as specified and directed. (Make: Philips Cat No. SM 365C LED 32-6500 PSU OD WH or Havells Cat Part No. ENDURAPEARLSL25WLED 757SASY TOPC or equivalent model in the makes given in Appendix 'C').
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED tube including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Makes: Philips Cat No. BN021LED 12S6500 PSUGR or Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCSS or equivalent model in the makes given in Appendix 'C').
Supply and fixing Ceiling fan complete with fan blades, down rods, modular stepped type double module electronic regulator and accessories , 230 Volts 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC), complete all as specified and directed.
Supply and fix Exhaust fan, steel body, AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and directed. (Make: Havells Model No DB NEO or equivalnent model in Makes given at Appendix 'C').
S&F Powerline Vertical TPN DB with suitable upto 160 Amp MCCB incomer, double door (IP-54), 4 way, built in 250 Amp copper busbar for each phase complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed. (Make: Legrand Cat No: 507752 or equivalnent model in Makes given at Appendix 'C').
S&F MCB SP 63 Amp of rating 240 volts 10 KA,'C' curve, in the MCB DB complete with connection, testing and commissioning, complete all as specified and directed.
S&F 70 watt new generation energy saving and enviromental friendly long life LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built-in surge protection device suitable for pole dia 54 mm (max) complete all as specified an directed. (Make: Havells Cat Part Num-ENDURACITYLINERNE OSL70WLED 757 PASYBOTG or Philips Model No- BRP409 LED 060 CW HE NR PC S1 PSU GR (Green line) or Wipro Model No- LR02-671-XXX-57-G2 (Skyline) or Bajaj Model No- BRTFG 60W LED V3 WW (Edge LED).
S&F PVC cable PVC insulated sheathed aluminium conductor 1.00 sqmm flar/round three core 1100 Volts grade, complete all as specified and directed.
S & F Street light brackets made out of 40 mm dia GI light grade pipe duly bend by hot forging after filling of sand of length 1.50 metre including two pairs of MS flat iron strip 40 mm x 4 mm clamp of suitable size with necessary GI nuts, bolts 75 mm long 12 mm dia - 02 Nos with flat washers 3 mm thick - 2 Nos including painting with aluminium paint over one coat of red oxide primer to the MS claps and bracket etc. complete and fixing on walls / poles complete all as specified and directed.
S & F Thermo plastic street light junction box of size 280 x 170 x 130 mm of make Sintex Cat No GS-JB-2817 top hinged or equivanent of make National with MCB TPN 32 Amp for looping of cable for 3 phase and neutral, fixed on pole with and including MS nuts bolt and MS clamps -1 No of size 40 mm x 4 mm thick and one MCB SP 6 Amp capacity mounted on din rail inside the box, complete and fixing on walls / poles complete all as specified and directed.
S&F New generation Post-top, energy saving, envoronmental friendly, long life asthetically designed with symetrical light distribution, spun aluminium landscape luminaire with IP-65 protection, 25 Watt LED as light source, complete all as specified and directed. (Make: Havells Model-RUBYPT25WLED757PSYMTOPC or equivalent model in makes given in Appendix 'C').
M&L for making underground boaring (manually / mechnically) through existing bituminous road / PCC Floor along cross section of road for laying of G.I. tubing for encasing of cable and repairing the damages surfaces to match with the existing finish, complete all as specified and directed.
M&L for Cutting through existing bituminous road / PCC floor of approximate size 50 cm x 60 cm depth along length 3 m to 6 m cross section of the road for laying of GI tubing / RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and directed.
S&F On line UPS for 30 minutes back up, three phase, AC input 300 to 450 V and output 415 Volt (±) 1% of capacity 7.5 KVA with and including battery bank of suitable capacity and battery racks, complete all as specified and directed.
M&L Painting lines, dashes, arrows, letters etc. on road /pavement, any shape and size or 2 mm thick road marking strips etc. using hot thermoplastic material fully/ semi-automatic application machine fitted with profile shoe heater and driven by experienced operator in white or golden yellow colour including preparation of surfaces complete all as specified and directed.
S&F Cat eye white / green / yellow of size 90 mm x 117 mm x 17 mm ABS body conforming to IRC: 67-1977suitable to give reflection on both side and having 40 ton load capacity complete all as specified and directed. (Makes - Siddhi Vinayak Enterprises / Road Safety Mark / Dark Eye / Alaxius / 3M / Greenlite).
S&F Steel cat eye "Solar type" heavy duty of minium size 100 mm x 90 mm, double side flashing, three LED on each side, fixed on road with nails complete all as specified and directed. (Makes - Siddhi Vinayak Enterprises / Road Safety Mark / Dark Eye / Alaxius/ 3M / Greenlite).
Supply, installation, testing and commissioning weather, dust and vermin proof, outdoor type, floor mounted, CPRI Approved LT panel board, factory fabricated, totally enclosed, front & rear opening doors type, suitable for 415 Volts, 3 phase, 4 wire, 50 Hz AC supply, depth not less than 500 mm, IP-54 class protection, made out of 3.00 mm thick CRCA sheet metal outer and 1.60 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments and duly powder coated after seven tank process on both sides, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694 marked or PVC sleeved copper strips of appropriate sizes but not less than 4.00 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom o panel shall be at minimum 60 cm above ground level, all accessires prewired complete with danger notice board with and including the following controls and accessories:-
(a) Aluminium bus bar 500 Amp capacity for Phase-R-Y-B and 250 Amps for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and neutral)
(b) Incoming - 4 Pole MCCB 320 Amp, 50 Hz, 415 volt with rupturing capacity 36 KA with adjustable thermal and magnetic settings - 01 No
(c) Outgoing- MCCB 4 pole 415 Volt 160 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 25 KA (Ics = 100%Icu) - 02 Nos and MCCB 4 pole 415 Volt 125 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 16 KA (Ics = 100%Icu) - 01 No and MCCB 4 pole 415 Volt 63 Amp rating with thermal and magnetic settings, 50 Hz, breaking capacity 10 KA (Ics = 100%Icu) - 01 No [Total 05 outgoings].
(d) MCB TPN 32 Amp 10 KA - 01 No
(d) Voltmeter digital square type of range 0 - 500 Volts - 01 No
(e) Ammeter digital square type of range 0 - 500 Amp with suitable capacity CTs - 01 No
(f) LED phase indicator of Red, Yellow and Blue - 01 Set of 03 lamps
(h) Automatic street light ON/OFF timer of capacity not less than 6 KW 3 phase, 4 wire with suitable capacity of contactor, relays, control wiring and all accessories all as specified and directed.
(j) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(k) PCC foundation 1:2:4 type B-1 of suitable size as directed by Engineer-in-Charge.
NOTES:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured static, silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 160 KVA at power factor 0.8. water coolled, 415 Volts (AC three phase, 4 wire system of supply) 50 Hz. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet, return inlet oil arrangement exhaust pipe complete and suitable for conditions prevalent at devlali (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease up movment and 0.5M height above NGL) antivibration pads, including all features to comply with latest CPCB guidelines of emission control as per CPCB norms-II and comprising of followings:- Makes: As per Appendix 'C'.
(A) Engine (Prime Mover):- Diesel Engine 1500 RPM, Direct injection muiti Cylinders, four stroke, confirming to ISO 3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 160 KVA at outdoor atmospheric conditions at Devlali, (Taking all derating factor into consideration), 12 Volt (as per manufacturer recommendations) electrical battery start, complete with fly wheel with all standerd fittings/fixtures as per manufacturer and including suitable panel for tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, indication for High water temperature, low lub oil, oil pressure, over speed etc.), multi functional meter for RPM, PF,hrs runs, frequency, oil pressure,temp,amps and voltage indications, fuel tank and first fill of lub oil, coolant and other consumables etc.
(B) Alternator:- Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 160 KVA, at power factor 0.8, 1500 RPM, IP 23 class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
(C) Base Plate:- It shall be made out of structural steel as per manufacturers recommended design/specifications.
(D) Acoustic Enclosure:- Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No.371 (E) dt 17 May 2002.
(E) Foundation/Plinth/Base:- It shall be provided as per manufacturers recommendation, however minimum 0.5 m space should be available all around the set and height of plinth shall not be less than 0.5 m above normal ground level.
(F) Diesel storage tank:- It shall be of capacity adequate for storage of diesel for 12 hours operation of Gen set.
(G) MISC:- Tool kit, Operation and maintenance catalogue, spare part list overhauling manuals guarantee card etc shall be provided as per manufacturer standard pratices.
NOTES
(i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI design.
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator all as specified and directed.
(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.
(iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements including consumables like diesel, oil, coolant, load for testing etc are to be made by the contractor for the tests.
Supply, installation & testing of AMF Panel with AST kit out door type of size 1.5 m x 1.2 m x.0.5 m made out of 3.00 mm thick CRCA sheet, aluminum bus bar of suitable size, internaly pre wired, panel shall be totally enclosed dust, weather & vermin proof, with powder coated after washed with RR- 10 chemical for rust proofing, mounted on 50 x 50 x 6 mm angle iron stand floor mounted & cosisting of following accessories:-
(a) Automatic Source Transfer System (ASTS DN2-250A) 250 Amps. Make L&T Model No DN2 250.-01 set (Complete with connecting bus-bar assembly, Cable harness, 2 MCCBs 250 A (DN2) + 2 SE-EOM + 2 ATAC + 1 MIL kit).
(b) Automatic Transfer Controllers (ATC) (AuXC-2000) with cable harness Make- L&T Cat part No ATC2000OOOO - 01 No.
(c) Control MCB SP 6 Amp. 230 V - 6 Nos.
(d) LED Indicating light for Main & DG R-Y-B power supply - 6 Nos.
(e) LED Indicating Light for Main & Gen. ON - 2 Nos.
(f) Battery Charger (inbuilt) with LED Indicating Light for battery Charger -1 No.
(g) Multi functional meter for Volt, Amps, PF, Frequency, Make- L&T Model WL4405100000.
(h) MCCB 250 Amps 4 pole 50 KA (CM92106OOP1OG). Make- L&T with spreader link - 02 Nos
(j) CT Coil of suitable ratio - 6 Nos.
(k) Engine start relay.
(l) Connector block for control wiring.
(m) Auto / Manual Switch - 1 No.
(n) Start & Stop Push Button with cable harness--1 Set
(o) Aluminium bus- bar of capacity 400 A.
(o) Aluminium bus- bar of capacity 400 A.
NOTE: Certificate for compliance of CPCB norms-II of emission limit to be provided by the contractor before despatch of the DG set from factory.
Supply, Installation, Testing and commissioning of Maintenance free Chemical Earthing of hard rock with bore well machine of Dual pipe Technology of 3 m long with outer pipe Diameter of 88 mm & inner pipe diameter 48 meter outer surface of pipe shall be properly copper coated up to 250 micron and wall thickness of inner pipe shall be 2.6 mm and 1.8 mm for outer pipe. The terminal for connecting of 75 x 5.2 mm with two holes of 14 mm diameter, Fast Electrode duly filled with the highly conductive material with sealing at both ends with lead terminal of 75 x 5.2 mm at top. The fast electrode shall be duly tested & certified by CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 kA. The Electrode should be tested in MSME Govt of India. The Electrode should be tested for sold spray test as per BIS 117-09 for Corrosion for minimum 500 Hrs alongwith supply of fast electrode earth enhancing compound shall be tested and Chemical compound shall be tested and certified by any international accredited and BIS (Bureau of Indian Standards) accredited laboratory all as specified and directed. MAKE- Fast Electrode Pune HSN SAC Code : 85351010 or equivalent as approved by GE. NOTE : (i) Earthing place may very in soft/ hard soil or soft rock (ii) Earth test result should be less than 01 Ohm. (iii) GI protection pipe light grade 40 mm dia and copper earthing strip 10 x 3 mm upto 7.5 mtr deemed to be included in rate quoted.
M&L copper strip of size 20mm x 3mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .