| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.2 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹21.5 L+₹1.6 L (7.95%)Rejected-Finance | 2 | Rejected-Finance Being not lowest | |
| 3 | 3₹21.8 L+₹1.9 L (9.41%)Rejected-Finance | 3 | Rejected-Finance Being not lowest | |
| 4 | 4₹22.6 L+₹2.7 L (13.4%)Rejected-Finance | 4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
22 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I)
AGE (I) Fatehgarh
SPL REPAIR TO BLDG NO T-24 (OR MARRIED ACCN) OF RRC FATEHGARH CANTT..
2021_MES_451398_1
AGE(I) /FAT/ET-10 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹48,000
Yes
10 Sept 2021
14 Jun 2021
24 Jul 2021
14 Jun 2021
22 Jul 2021
29 Jun 2021
14 Jun 2021 - 28 Jun 2021
60 days
Amount
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
Dismantiling Floor, hearth or Wall tiling including cement mortar bedding (but not baking), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed.
Taking down Chowkhats incl shutterrs (without taking off shutters from the frame) n.exc 1.5 sqm each etc complete all as specified and directed.
Taking down Chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4.00 sqm each etc complete all as specified and directed.
Taking down Cement Plaster on brick work or concrete surfaces incl racking out joints etc complete all as specified and directed.
M&L for 75 mm thickness PCC 1:3::6 type C2 using 40mm stone aggregate in plinth protection including finishing smooth without using extra cement, all as specified and directed.
M&L for 15mm thick Rendering in CM 1:6 on brick work or concrete surfaces finished even and smooth etc complete all as specified and directed.
M&L for 15mm thick Rendering in CM 1:4 on brick work or concrete surfaces finished even and smooth etc complete all as specified and directed.
M&L for 5mm thick Rendering in CM 1:3 on brick work or concrete surfaces on ceiling finished even and smooth etc complete all as specified and directed.
M&L preparation of Newly plastered surfaces and applying three coats of White Wash on ceiling etc complete all as specified and directed.
…..ditto…as above but for old surfaces of ceiling, including removal of existing treatment ….ditto…
M & L complete removal of exting treatment and applying two coats of oil emulsion distemper over a coat of chalk whitening on complete all as specified and directed.
M&L preparation of Newly plastered surfaces and applying two coats of oil emulsion distemper over a coat of chalk whitening on complete all as specified and directed.
Complete Removal of existing treatment including Preparation of old surfaces and applying Two coat of Cement Base Paint on walls over alkali resistant primer all as specified and directed.
M & L for two coats of Cement based paint over a coat of alkali resistant primer on new plastered wall surfaces including preparation all as specified and directed.
Coloured Non Skid Joint less ceramic tiles (non-skid) of size 400mm X 400mm X 7mm thick, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed including taking down old screed bed complete.
M&L Glazed ceramic coloured tiles 350x250x7mm / 450 x 350 x 7mm thick as in Vertical surfaces set and jointed in neat cement slurry and jointed or coloured cement to match etc complete over 10 mm th rendering in CM 1:4 all as specified and directed.
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm th screed in CM 1:4 compelte all as specified and directed.
M&L for machine cut kota stone slab as a single piece in stair case trades, flooring 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including grinding, rubbing and polishing to mirror finish with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
S&F pressed steel frame for door, made 1.25mm CRCA profile sheets of size 105 mm x 60mm with one or more rebates including necessary Fixing lugs, hinges lock strick plate etc. complete all as specified & directed.
S&F pressed steel frame for door, made 1.25mm CRCA profile sheets of size 125 mm x 60mm with one or more rebates including necessary fixing lugs, hinges lock strick plate etc. complete all as specified & directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube as per specification & drawings specified in SSR Part-II 2020 complete all as specified and directed.
S & F mild steel flat iron as in hold fast and similar small articles conforming to Fe 290 Gde E 165 complete all as specified and directed.
M & L for PCC 1 : 3 : 6 type C-0 using 12.5 mm graded stone aggregate as in filling inside frame or steel chowkhats of doors and windows complete all as specifed and directed.
M & L for PCC 1 : 3 : 6 type C1 using 20 mm graded stone aggregate as in fixing of hold fast including necessary form work complete all as specifed and directed.
S&F Factory made solid panel pvc door shutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain col-our PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawings specified in SSR Part-II 2020 complete all as specified and directed.
S&F factory made 32mm thick Flush shutters , solid core construction , with particle board core and plywood face panels, both faces is covered with decorative face veneer with lipping / frame to match complete all as specified and directed.
S&F 35 mm thick factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8 complete all as specified and directed.
S&F factory made Steel Window 1.25mm thick Box Type (primer coated) ERW hollow P section of size 60mm x 25mm, 1.25 thick sheet single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:2:4) type B-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Hold Fast, 150mm long of 12mm square bar made to shape – 04 Nos per window (b) Handles of Z Sec 100mm long (c) Stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mm x 63mm welded to hinges – 01 No per leaf (e) MS Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Fabrication & fixing arrangement as per drg No. CEJZ/TD-7/07 sheet 1/3 of 3/3. Note : Glass and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed.
S&F Steel Window 1.25mm thick Box Type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf without sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Wire mesh and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section of 125mm size etc complete all as specified and directed.
S&F Alum anodized barel tower bolt of extrud sec 200mm long complete all as specified and directed.
S&F Alum anodized barel tower bolt of extrud sec 150mm long complete all as specified and directed.
S&F aluminium alloyed handle cast type anodized of size 150mm long complete all as specified and directed.
Supply only but hinges med weight cold rolled mild steel 100mm size complete all as specified and directed.
S&F 250 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S & F mild steel sliding door bolt 300mm long clip type, stove enamelled black with bright bolt not less than 16mm dia complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each panel complete all as specified and directed.
S & F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wodden beads to steel windows/wodden doors.
M&L Preparing surfaces new of steel and applying two coats of SE paint, over a coat of red oxide primer complete all as specified and as directed.
M&L Preparing surfaces new of steel and applying two coats of SE paint complete all as specified and as directed.
M&L preparing surfaces new of wood and applying two coats of SE paint over a coat of pink primer complete all as specified.
S&F 20 mm dia harrison rails mild steel with decorative finish , with fixing brackets , stops, rollers complete all as specified and as directed (two brackets per 1.5 M length and 08 Nos roller per 1.RM)
Removing existing water proofing treatment of any type all as directed by Engineer-in-charge and disposing off out side Defence Land including Cleaning the surface by roughening, sweeping clean and washing down and applying cement slurry @ 3 kgs/sqm.
M&L for 40mm thick cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) as in RCC roof surface with mixing of water proofing compound 3% by the weight cement to horizontal or vertical surfaces finished cement concrete surface even and smooth using extra cement including necessary form work Note:- (Water proofing compound will be measured separately)
M & L for water proofing treatment to roof slab with APP modified polymeric membrane with centre core 100 micron HMHDPE out film 20 micron each having thickness 3 mm, weight not less than 3.00 kg/sqm with 100 mm side overlap and 150 mm end lap and laid with following course of descriotion below :- (a) Applying evenly a coat of bituminous primer conforming to IS 3384 - 1965 @ 0.50 ltr /Sqm prepared surface till the surface is properly impregnated and solvent oil in primer shall be allowed to evaporate completely. Second coat of bonding material using hot blown grade bitumen 85/25 @ 1.2 Kg/Sqm conforming to IS 702 - 1988 over bituminous primer. (c) Third course i.e. laying of APP modified polymeric membrane describe hereinbefore with 100 mm over lap in longitudinal direction and 100 mm in transverse direction, all joints and changes in all diretion should be curred with cement mortar (1 : 3 ) mixted with SBT Latex @ 200 ml per bag of cement and curred well before laying themembrane. (d) Fourth course of bonding material using hot blown grade bitumen 85/25 confirming to IS 702- 1988 @ 1.2 kg/sqm over membrane. (e) Fifth course is sprinkling a layer of course sand dusting @ 1 Kg/Sqm as directed.
Supply only WPC
S&F in repair Stop valves, cast copper alloy, bore dia of pipe in 15mm, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for ironn pipe and fixed but fancy type, Chromium Plated with long shank and cup (concealed type) etc complete all as specified and directed.
Chromium plated bib tap cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe and fixed to 15mm bore pipe fixed as in repairs including taking down old tap of any description complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed.
S&F in repairs Vitreous China Squatting Pan “Orissa Pattern” of size 580mm x 440mm, white with, integral foot rests front or back inlets including lime concrete bedding and CI P Trap complete all as specified and as directed by Engr-in-Charge etc complete all as specified and directed.
S&F in repair Low Level Flushing System PVC valveless syphonic action type, 10 ltrs capacity including supply pipe & fixing brackets of M.S. angle of size (25mmx25mmx3mm), 30 cm long in PCC (1:2:4) type B-1, block of size (10cmx10cmx10cm) on walls etc complete all as specified and directed.
S & F in repairs swivel shower PTMT with shower arm 195mm long with bend of 45 degree 15mm dia (minimum weight 40 gms) complete all as specified an directed.
S&F CP garting 100mm dia with waste hole of etc complete all as specified and directed.
Taking up or down existing steel tubing and connections of walls ceiling, floor etc of 15 mm bore including removal to store etc complete all as specified and directed.
…ditto as above but for 20mm bore….ditto…
S&F Steel Tubes Medium Grade Bore of tube in 15 mm galavanised with all fitting laid in trenches, walls, ceiling or laid in floors etc complete all as specified and directed.
…ditto as above but for 20mm bore….ditto…
S & F rotational moulded polyethylene water storage tanks of triple layer 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC Float valve(Make Parayg) also dismantling of existing tank and removing from site complete all as specified and directed.
S & F in repairs concealed stop cock fancy type chromium plated with long shank (concealed type) or angle cock 15mm bore complete all as specified and directed.
Demolition cement conc in any description and in any position complete all as specified and directed.
M&L for water proofing treatment to floor and vertical surface of sunken portion complete all as specified and directed with including following :- (a) After demolition of floor and cement concrete remove all loose particles alongwith existing water proofing treatment (any no of layers) with wire brushes a d cleaning the surface with water. (b) Brushing cement slurry with 1.2 kg of cement per square metre duly blended with acrylic water proofing compound. (c) 15mm thick (average thickness) plaster in cement mortar (1:3) mixed with acrylic water proofing compound on sunken surface and wall. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe. (d) Brushing cement slurry with 1.2 kg per square metre duly blended with acrylic water proofing compound. (e) Curring the sunken portion with water minium for 48 hours by ponding.
M&L for Cement concrete Type E2 1:5:10 ( 40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Taking down CI pipe of any size and pattern including fitting complete all as specified and directed.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors/wall complete all as specified and directed.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors/wall complete all as specified and directed.
S&F for cast iron 100mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured)/ with oval acess door complete all as specified and directed.
S&F for cast iron 75mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured)/ with oval access door complete all as specified and directed.
S&F for cast iron 75mm bore Branch pieces, double (equal or unequal ), ordinary or inverted ) (spigot or socket type ) or with parallel branches complete all as specified and directed.
S&F for cast iron 100mm bore Bends (any radius) with duck's foot or heel rest complete all as specified and directed.
S&F for Cast iron cowls for 100mm complete all as specified and directed.
S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore CI pipes complete all as specified and directed.
S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore CI pipes complete all as specified and directed.
S&F for Cast iron floor trap, with grating including jointing to waste pipe in run lead complete all as specified and directed.
Framed work as in doors or gates and chowkhats of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to GdeFe 290(Gde E-165) complete all as specified and directed.
S&F for Expanded metal in available size weight not exc. 4.00 kg per Sqm complete all as specified and directed.
S&F in repair stainless steel 1 mm thick kitchen sink, with drain board of size 915 mm x 460 mm , bowl size 410 mm x 330 mmx 160 mm, including, waste coupling, PVC flexibale waste pipe etc complete in all respect, fixed on MS brackets complete all as specified and directed.
S&F utencil plate rack 1 mm th of size 60 cm x 60 cm, of pattern as approved by engineer-in-charge, fixed to wall by means of four nos rawal plugs, complete in all respect complete all as specified and directed.
S & F in repair Grating 125 mm dia with with/without waste hole of PTMT complete all as specified and directed.
S&F in repair CP brass towel rail `D’ type 60Cm long fixed to wall complete all as specified and directed.
M&L for 40 mm thick PCC 1:3:6 type B1 using 20mm graded stone aggregate as in flooring and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for coloured chequred cement concrete tiles 25cmx25cmx25mm thick, set, jointed and pointed in neat cement slurry in floor with white cement and pigment including screed bed of 15mm thick in CM 1:6 including dismantling old existing treatment complete all as specified and directed.
S&F in repairs ; salt-glazed stone –ware gully traps of size of gully traps in 150 mm , square or round mouthed, type ‘P’.complete all as specified and directed.
Demolition of brick work or stone /boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M & L Brick work using old size sub class B bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1 : 6 complete all as soecified and directed.
M & L Brick work using old size bricks (Except brick) straight or curved on plan exc 6 m mean radius built in cement mortar 1 : 6 complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable sub main wiring of copper/aluminium conductor with two run of single core cable with one run of single core earth conductor cable of any description, any size & in any position including taking out existing unserviceable conduits or battens of any description and making good the disturbed surfaces to the existing surfaces all as specified and directed.
Material and labour for point wiring for one light point or one fan or bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC (FRLS) insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size all as directed with using new sunken type pressed steel box / terminal boxes for mounting fittings/junction boxes not less than 1.6mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick bakelitelaminated sheet, and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. Note:- i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
…..ditto as above above but point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board controlled by one switch….ditto…
…..ditto above but point wiring for 5 pin switch socket outlet, 5 Amps on same board with other switches …ditto..
..ditto as above but point wiring for one six pin socket outlet, 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor …ditto...
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
Fixing only switch piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
Fixing only switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
S&F switch socket combination 5 in 1, 5/15 Amp flush type complete all as specified and directed.
Fixing only switch socket combination 5 in 1, 5/15 Amp flush type complete all as specified and directed.
Supply and fixing bell push ac 230 volts. complete all as specified and directed.
Supply and fix bell ding dong AC 230 volts complete all as specified and directed.
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings complete all as spcd & directed.
S&F LED lamp of 9W and colour temp 6500K suitable to fix in angle hoder complete all as specified and directed.
Supply and fix electronic fan regulator 120 watts 5 stepped type complete all as specified and directed
S&F in replacement metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket suitable for one single pole MCB 32 Amp complete all as specified and directed.
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 2.5 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm FRLS and one run of 2.5 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing in replacement of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
S&Fin replacement of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in replacement of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.
S&F in replacement MCB single pole 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F in replacement of MCB SPN 63 Amp 240 volt complete all as specified and directed.
S&F surface and wall mounted 18/20W LED extruded aluminium batten fiitting provided for efficient heat dissipation (Make :- Philips Cat No BN021C LED20S PSU CW GR S2 & equivalent to specified make)
S&F surface and wall mounted LED 10W extruded aluminium batten fitting with rod complete. (Make :- Philips Cat No BN021 LED10S-6500 PSU GR S1 & equivalent to specified make)
S&F building security LED light 14 watt with IP-65 including suitable size of GI bracket complete all as specified and directed. (Make: Philips Cat No BRP 042 LED 14 CW MR S1 PSU GR or equivalent to specified make
S&F of LED wall light 12 W unbreakable poly carboante suitable for mounting on wall surface complete all as specified and directed.
M & L Earthing complete with galvansied steel earth plate electrode 600x600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below ground level earth plate connected with GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nut and wahers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I and testing on completion. Including neccessary excavation and earth work, adequate common slat, charcoal dust and funnel PCC (1:3:6) type C-1 pit with pre-cast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 8 mm dia bars, MS bar 3 Nos both ways funnel with 20, mm dia GI grade watering pipe earthing lead with GI protection pipe medium grade 15 mm dia up to 7.5m. from earth plate to equipment earth point complete all as specified including dismantling of existing earthing.
Shree Gopal Engineers & Contractor
M/S S P CONSTRUCTION
M/s Moti Babu Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .