Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹5.4 L Quoted ₹6.4 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹6.9 L+₹50,901 (7.99%)Rejected-Finance | ₹6.9 L+₹50,901 (7.99%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹7.4 L+₹1.1 L (16.8%)Rejected-Finance | ₹7.4 L+₹1.1 L (16.8%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹7.8 L+₹1.4 L (21.6%)Rejected-Finance | ₹7.8 L+₹1.4 L (21.6%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹7.9 L+₹1.5 L (23.7%)Rejected-Finance | ₹7.9 L+₹1.5 L (23.7%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Sept 2023, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
REPAIR MAINTENANCE OF CEILING FAN EXHAUST FANS WALL MOUNTED FAN AND OTHER ALLIED WORKS AT 7AFH KANPUR CANTT
2023_MES_616207_1
GE(AF) BR/CHK/T-16 OF 2023-24 8874/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
7 AFH Kanpur Cantt
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri
₹20,000
Yes
20 Jan 2024
29 Aug 2023
3 Oct 2023
29 Aug 2023
26 Sept 2023
14 Sept 2023
Amount
CEILING FAN M & L for servicing of ceiling fans, any sweep/size at existing position on various location of 7 AFH for maintenance after removing cable connection from ceiling rose, checking, tightening of thread of down rod, opening of fan, greasing/oiling of bush/ bearing, re-assembling and fixing the same in position including replacement of minor parts such as split pin, lock bolt, check nut and cable flexible from ceiling rose to ceiling fan of size 23/0.0076 and connection etc including testing for its smooth running complete all as specified and directed. Note: Bearing, capacitor, bush,fan blade will be paid separately under respective item of Sch ‘A’ as "Supply only".
Supply only following components for ceiling fan : Note:- Rate for taking out and fixing is included in item No 1.00 above
Ball bearing for ceiling fan of size 6201 to 6204 Make: NBC/ SKF.
Capacitor of 2.5 Mfd Make: Unistar /EPCOS/Renutral
Gun metal bush as per sample
Ceiling fan blade set of three of 1200mm sweep.
M&L for rewinding of ceiling fan stator with appropriate gauge size super enamelled copper wire including necessary insulation material after cleaning of stator for 1200 mm sweep ceiling fans complete all as specified and directed.
Ditto all as per item No.3.00 here-in-before but for 1400 mm sweep ceiling fans
M&L for spray painting to ceiling fan with down rod, blade etc. of any make and sweep installed at various location of 7 AFH with two coat of Duco paint of approved colour & marking MES No including cleaning of old paint complete all as specified and directed.
EXHAUST FAN M&L for servicing of exhaust fans, any sweep/size at existing position on various location of 7 AFH for maintenance after removing cable connection from ceiling rose, checking, tightening of nuts, bolts, opening of fan, greasing/oiling of bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin and cable flexible from ceiling rose to ceiling fan of size 23/0.0076 and connection etc including testing for its smooth running with and including writing MES No with synthetic enamel paint complete all as specified and directed. Note: Bearing, capacitor, fan blade and frame will be paid separately under respective item of Sch ‘A’.
Supply only following items for exhaust fans:- Note:- Rate for taking out and fixing is included in item No 6.00 above
Capacitor 4 Mfd, 230 Volt Make: Unistar/EPCOS/Renutral.
Ball bearing No. 6201, 6202, 6203, 6204 of Make: NBC/SKF
Exhaust fan blade of any sweep with screws/bolts, nuts.
Exhaust fan frame with louvers complete with nut & bolts etc.
M&L for rewinding exhaust fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed for following sizes:-
225 to 300 mm sweep
450 mm sweep
PEDESTAL FAN M & L for repair & overhauling of defective Pedestal fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricant oil and greasing as required including M&L for rewinding the stator with super enameled copper wire of existing gauge with insulation materials, re-assembling the pedestal fan after replacement of defective components/ repair and replacing minor items such as clamp, back cover, screw lock, nuts, welding guards etc. including spray painting with a coat of synthetic enameled paint of approved shade after preparation of old surfaces and writing MES No. with black synthetic enamel paint including testing for its smooth functioning complete all as specified and directed. Note: Spare parts viz Gun metal bush, capacitor, blade & shaft will be measured and paid separately under respective item of Sch ‘A’.
Supply only following items for pedestal fans:- Note:- Rate for taking out and fixing is included in item No 9.00 above
Gun metal bush as per existing size.
Capacitor 4 Mfd, 230 Volts oil filled Make: Unistar /EPCOS/Renutral
Pedestal fan blade
Pedestal fan shaft.
M & L for repair & overhauling of defective table mounted fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricants oil and greasing as required including M&L for rewinding the stator with super enameled copper wire of existing gauge with insulation materials re-assembling the table mounted fan after replacement of defective components/ repair and replacing minor items such as split pins, bolts, nuts, welding guards etc. including spray painting with a coat of synthetic enameled paint of approved shade after preparation of old surfaces and writing MES No. with black synthetic enamel paint including testing for its smooth functioning complete all as specified and directed. Note: Spare parts viz Gun metal bush & shaft will be measured and paid separately under respective item of Sch ‘A’.
Supply only following items of table fans:- Note:- Rate for taking out and fixing is included in item No 11.00 above
Gun metal bush.
Fan shaft.
WALL MOUNTED FAN All as per item No.11.00 here-in-before but wall mounted fan of any sweep. Note: Spare parts viz Capacitor, Gun metal bush & shaft will be measured and paid separately under respective item of Sch ‘A’.
Supply only following items of wall mounted fans:- Note:- Rate for taking out and fixing is included in item No 13.00 above
Capacitor 2.5 Mfd, 230 Volts Make: Unistar /EPCOS/Renutral
Gun metal bush.
Fan shaft.
M & L for replacement ceiling fan down rod of 2 ft, 2.5 ft, 3 ft and 4 ft made out from GI Pipe 25 mm bore dia, medium grade including fixing hook or clamp made out from iron complete with nuts and bolts and washers of suitable size duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose, pendant holder, fitting and fixtures, call bell etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper or white colour wash complete all as specified and directed.
M & L for point wiring with PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sqmm, 1100 V drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box 1.6 mm thick of required size Bakelite sheet 3mm thick for mounting switch, socket, brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sqmm will be used as continuous earth wire for the following :-
One light /fan point controlled by one, one way switch
One 5/6 Amp socket on the same board with other switch
One 5/6 Amp socket on independent board.
One bell point controlled by one, one way bell push button.
All as per item No 17.00 but for one 3 pin 15 Amp socket on independent board using 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm
S & F switch piano type 240 V, 5 Amp, Sp one way flush type complete all as specified and directed.
S & F bell push 240 V, 5 Amp, Sp one way flush type complete all as specified and directed.
S&F socket outlet multipurpose 3 Pin 5 amp, 240 volt and with 2 pin 5 amp outlet also flush type (non shuttered) complete as specified and directed.
S&F socket outlet 3 pin 15 Amp, 3 Pin 5 Amp out let also flush type (non shuttered) complete all as specified and directed.
S&F switch piano flush type single pole one way 15 Amps complete all as specified and directed.
S&F in repair of sheet metal enclosure for MCB DB TPN, double door, 4 way complete with 200 Amps rated Bus bar complete all as specified and directed.
S&F in repair of switch socket outlet combination multipurpose 3 Pin 5 amp, 240 volt and with 2 pin 5 amp outlet also flush type (non shuttered) complete as specified and directed.
S&F in repair of switch socket outlet combination 3 pin 15 Amp, 3 Pin 5 Amp out let also flush type (non shuttered) complete all as specified and directed.
S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S&F for lamp holder metal cased body of brass with back plate complete with 5 Watt LED lamp complete all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board TPN, 4 way double door type including with MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
All as per item No. 30.00 here-in-before but SPN 4 way 240 Volt.
S&F in repair Isolator SPN, 63 Amp, 240 Volt complete all as specified and directed.
S&F in repair MCB SP upto 40 Amp, 240 Volt complete all as specified and directed.
S&F in repair MCCB 4 Pole, 16KA, 100 Amps fixed type with sheet metal enclosures factory fabricated complete all as specified and directed.
S&F in repair Isolator SPN, 20 to 40 Amp, 240 Volt complete all as specified and directed.
S&F bell electric , 240 Volt , single pole complete all as specified and directed.
S&F fan regulator Electronic type 240 Volt, single phase suitable for ceiling fan step type complete as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete. RCC 1:2:4 Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip 32x6mm protection etc. complete all as specified and directed.
M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia concealed type with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly, including taking out the old sub main wiring complete all as specified. Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run complete all as specified.
All as per item No.39.00 here in before but 6 Sqmm, 2 single core with PVC FRLS insulated, unsheathed stranded copper conduct cable of size 6 Sqmm as earth lead complete. Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run complete all as specified.
S & F in repair industrial type metal clad plug top & socket single pole and a neutral link earth enclosure with MCB Sp 20 Amp complete all as specified and directed.
S & F in repair bulk head fittings of any type with LED bulk fitting with 6 watt LED complete connection with copper wire 23/0076 two core from ceiling rose to bulk head fitting complete all as specified and directed. Make C&S Model No. CG801B6WLED or equivalent model of Philips/Wipro/C&S.
S&F in repair fluorescent tube light fittings complete energy efficient T-8 LED batten and integrated type signle tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as specified and directed. Make Cormpton Greaves Cat Part No DMLN1LT8-16 and LTT8-20 or equivalent of C&S/Philips/Wipro/Havells.
S&F in repair fluorescent tube light fittings complete energy efficient T-8 LED batten and integrated type signle tube 32 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as specified and directed. Make Cormpton Greaves Cat Part No DMLN1LT8-16 and LTT8-20 or equivalent of C&S/Wipro/Havells.
S&F in repair recessed mounted lumanaire with energey efficient 36 Watt LED type including making connection to ceiling rose with copper flexible wire of size 23/0076 complete all as specified and directed. Make Crompton Greaves model No. LCTLS-36-CDL or equilavent model of Havells/C&S/Wipro.
S & F in repair surface mounted downlight LED 12 Watt 22 volts AC recessed type with high efficieny PMMA diffuser sodt glasre free light complete with frivers, holders, LED lamp suitable for roof ceiling inclusinf connection up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair of Isolator TPN, 100 Amp, 4 pole Isolator, 415 Volt in existing DBS complete all as specified and directed.
Fixing only in repair exhaust fan including cutting of existing wall and making hole of required sizes for fixing of exhaust fan including nuts, bolts and washers and making good to disturbed surface of wall to match with existing surface either by using same colour distemper or white colour wash complete all as specified and directed.
M/s A S Electrical
commercial construction
M/S Asian Engineers
LARSEN AIR CONDITIONING & REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .