Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 512 227 5TH LANE NISHANTGANJ LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.2 L+₹74,760 (2.11%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹39.0 L+₹3.5 L (9.79%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹39.1 L+₹3.6 L (10.2%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹39.9 L+₹4.4 L (12.4%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
15 Dec 2020, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT TO GI PIPE LINE, PLUMBING, OH TANKS, WOODEN JOINERY, ALUMINUM JOINERY, SANITARY, BRICK WORK IN THE VARIOUS WARDS OF CHCC, BASE HOSP, CMDC AND OTHER AREAS IN THE AREA OF AGE E/M HOSP UNDER GE E/M LUCKNOW
2020_MES_395125_1
GE/EM/LKO/HOSP/T-64 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Lucknow
Class D or above category a (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹96,000
Yes
16 Jan 2021
13 Nov 2020
17 Dec 2020
13 Nov 2020
15 Dec 2020
3 Dec 2020
Amount
Dismantling asbestos Cement (corrugated, semi corrugated etc) sheet in roof covering complete all as specified and directed by Engineer-in- Charge.
Dismantling structural steel work including doors, windows & gates but excluding framed trusses etc complete all as specified and directed by Engineer-in-Charge.
Dismantling unframed timber scantling 40 sqcm and over in section, in any position complete all as specified and directed by Engineer-in-Charge
Dismantling of wall and ceiling board (fibre, pulp, insulation) or insulation board/slabs/blankets any thickness incl cover fillets complete all as specified and directed by Engineer-in-Charge.
S & F second class hard wood (Hollock) ,as in scantlings , clean sawn complete all as specified and directed by Engineer-in- Charge.
S & F mild steel rolled section as in rafter, purlins where connected to comman rafters and running rails fixed with angle cleats or other connecting plates. Confirming to grade Fe-290 complete all as specified and directed by Engineer-in- Charge.
S&F in 0.50 mm Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting made to any shape or Semi-ciruclar any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in- Charge.
S&F in 0.50 mm Pre-painted galvalume aluminium zinc coating GI based plain steel sheeting made to any shape or Semi-ciruclar any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in- Charge.
S&F for 1mm thick MS sheet valley gutters, galvanised class3 half round of length and girth as fixed with rounded edges complete all as specified and directed by Engineer-in- Charge.
M&L for preparation of new wooden surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of pink primer complete all as specified and directed by Engineer-in- Charge.
M&L for preparation of new steel & Iron surface of width or grith exceeding 10cm & applying two coats of synthetic enamel paint of 1st quality complete all as specified and directed by Engineer-in- Charge.
Providing and fixing of E-board 'Everest' make 600x600x4mm thick white prelaminated seif embosed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24 mm wide T-section/Angle section complete all as specified and directed by Engineer-in- Charge.
M&L Suspended ceiling, comprising 12 mm thick reinforced gypsum plaster boards Conforming to IS-2095 , GI perimeter channels, intermdiate channels, etc. including finishing the exposed surfaces with Oil bound distemper two coats complete all as specified and directed by Engineer-in- Charge.
M&L Preparing surfaces of wood and wood based materials , new or old , of any description and girth , not otherwise described and treated with creosote paint complete all as specified and directed by Engineer-in- Charge.
Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge
M&L for non skid ceramic tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.16 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 15mm thick screed (Note : Screed bed will not be measured and paid separately) complete all as specified and directed by Engineer-in- Charge.
M&L stain free double charged tiles 10mm thick (square/ractangular) Coloured polished tiles, area of each tile n.exc 0.38 sq m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement and pigment to match over 15 mm thick screeding (Note : Screed bed will not be measured and paid separately) complete all as specified and directed by Engineer-in- Charge.
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3 (Note : Screed bed will not be measured and paid separately) complete all as specified and directed by Engineer-in- Charge.
Glazed ceramic tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles over 10mm thick screed in CM 1:3 complete all as specified and directed by Engineer-in- Charge. (Note : Screed bed will not be measured and paid
M&L coloured/designed as approved wall/floor tiles (duracretes) 8 to 10 mm thick area of each tile exc 0.09 sqm but n.exc 0.16 sq m in vertical surface set and jointed in neat cement slurry and pointed in white/colured cement and pigment to match over 15 mm complete all as specified and directed by Engineer-in- Charge.
S&F in repair counter shaped wash basin (WHB) oval shaped including all fittings i.e. waste pipe & cp waste coupling complete all as specified and directed by Engineer-in- Charge.
S&F for fixed in repair bib cock 15mm dia with wall flange complete all as specified and directed by Engineer-in- Charge.
S&F for fixed in repair single lever basin mixer complete all as specified and directed by Engineer-in- Charge.
S&F in repair sensor controle (complete all as specified and directed by Engineer-in- Charge. incl all fitting & waste pipe.
S&F in repair cp angle cock (One way) with wall flange complete all as specified and directed by Engineer-in- Charge.
S&F in repair cp angle cock (two way) complete all as specified and directed by Engineer-in- Charge.
S&F 15mm bore, 450mm long PVC connection with PTMT nuts at each end complete all as specified and directed by Engineer-in- Charge.
S&F in repair Vitrious china padestal water closet (EWC), including jet sprey,flushing cistern & seat cover complete all as specified and directed by Engineer-in- Charge.
Taking up or down 15mm bore steel tubing and connections with fittings such as stop cock bib cock etc including cleaning for refixing or removal complete all as specified and directed by Engineer-in-Charge
Taking up or down 20 mm bore steel tubing and connections with fittings such as stop cock ‘bib cock etc including cleaning for refixing or removal complete all as specified and directed by Engineer-in-Charge
Taking up or down 25 mm bore steel tubing and connections with fittings such as stop cock ‘bib cock etc including cleaning for refixing or removal complete all as specified and directed by Engineer-in-Charge
M&L 15 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in- Charge.
M&L 20 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in- Charge.
M&L 25 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in- Charge.
S&F in repairs grating doom CP 100mm dia of plated with waste hole/witout hole as required complete all as specified and directed by Engineer-in- Charge.
S&Fin repairs of CP Towel Ring sqaure complete all as specified and directed by Engineer-in- Charge.
S&F in repairs of CP soap dish complete all as specified and directed by Engineer-in- Charge.
Demolition of stone slab and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in cement mortar complete all as specified and directed by Engineer-in- Charge.
M&L 18-20mm thick machine cut Kota stone slab flooring with marble stone strips/ slab/ tiles as per design approved, over and including cement screed bed 15mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade complete all as specified and directed by Engineer-in- Charge.
M&L 18-20mm thick machine cut Kota stone slab as in skirting /riser over cement screed bed 10mm thick in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing complete all as specified and directed by Engineer-in- Charge. (Note : Screed bed will not be measured separately
M&L 18-20 mm thick granite stone slab ( Black colour) , bedded over screed bed and jointed in cement mortar to match the colour of slab as in flooring/daddo , polishing and grinding complete all as specified and directed by Engineer-in- Charge. ( Screeding bed shall be measured and paid separately
M&L in repair for 3mm thick ACP sheet wooden finish along with frame work and making groove and shelf complete all as specified and directed by Engineer-in- Charge.
Taking down chowkhats or frame (wooden/aluminium) n. exc. 1.5 Sqm each with shutters (with out taking off shutters from the frame) and taken as credit complete all as specified and directed by Engineer-in- Charge.
Taking down chowkhats or frames (wooden/aluminium) with shutters without taking off shutter from the frames exc. 1.5 but n. exc 4 sqm each complete all as specified and directed by Engineer-in- Charge.
S&F Aluminium Anodised ventilator curved shaped fixed with reflective type glass aluminium section weighing 0.55 Kg/m incl necessary joining cleats, glazing clips rubber neosperene at bottom pannel and top panel with wire cloth of 0.46 nominal dia of wire and average width of aperature 1.4 mm complete all as specified and directed by Engineer-in- Charge.
S&F .Aluminium grill 6mm dia not less than 4 Kg per sqm fixed with frame in windows/ventilator complete all as specified and directed by Engineer-in- Charge.
S&F Anodised Aluminium alloy sections sliding windows shutters with frames comprising Series -C (20mm), 2 track sliding shutters duly fitted with neoprene beading, glazing clips,locking device, heat absorbing glass 4.8 mm nominal thicknes complete all as specified and directed by Engineer-in- Charge.
S&F for Aluminium Anodised door frame with shutter, incl necessary joining cleats, glazing clips rubber neoprene packing , Handle 2 Nos in each door, 4 Nos 100mm hinges, 1 Nos 200mm aluminium anodised tower bolt anodised aluminium snap beading screw ecessary locking arrangement with mortice lock with duplicate complete all as specified and directed by Engineer-in- Charge.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water complete all as specified and directed by Engineer-in- Charge.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed by Engineer-in- Charge.
M&L Brick work with fly ash bricks straight or curved on plan or curved on plan exc. 6 m mean radius built in CM(1:6) complete all as specified and directed by Engineer-in- Charge.
M&L for rendering 10 mm thick on brick work/ concrete surfaces in cement mortar 1:6 on fair faces finished fair & even complete all as specified and directed by Engineer-in- Charge.
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work surface finished even and fair without using extra cement complete all as specified and directed by Engineer-in- Charge. (Note : Integral WPC shall be measured and paid seprately )
Supply only integral WPC of approved quality complete all as specified and directed by Engineer-in- Charge.
Preparation of newly plastered surfaces and applying two coat of oil bound disemper over one coat of oil base primer all as specified on walls surface.Incl a coat of 2mm wall care putty complete all as specified and directed by Engineer-in- Charge.
M&L for preparing surfaces, newly plastered or unplastered new surfaces of walls and applying two coats cement base paint over one coat of cement base primer complete all as specified and directed by Engineer-in- Charge.
M & L for complete removal existing treatment and distempering old walls and applying two coat of oil bound disemper over one coat of oil base primer all as specified on walls surface.Incl a coat of 2mm wall care putty complete all as specified and directed by Engineer-in- Charge.
M&L for complete removal existing treatment and distempering old walls with two coats of cement base paint white or tinted over a coat primer on wall sufaces.Incl a coat of 2mm thick wall care putty complete all as specified and directed by Engineer-in- Charge.
Demolition of cement concrete (reinforced) in any position complete all as specified and directed by Engineer-in- Charge.
S&F Mild stee bars (TMT bars) 6 to 8 mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire [annealed] not less than 0.9 mm dia or scruing with clips complete all as specified and directed by Engineer-in- Charge.
M&L for providing RCC (Nominal mix ) type B-1 1:2:4 ( 20mm graded agg ) as in slabs supported on walls beams and columns in floors, roofs, landings balconies canopies deck slab and in shelves and the like complete all as specified and directed by Engineer-in- Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, n.exc 200mm thick fair finished concrete surface complete all as specified and directed by Engineer-in- Charge.
M&L for pre-cast RCC 1:2:4: type B1 using 20 mm graded stone as in cover slabs (for manholes etc) and set in CM 1:6 complete all as specified and directed by Engineer-in- Charge.
NEW BHARAT ENGINEERING AND CONSTRUCTION CO
M R CONSTRUCTION
m/s raghubar dayal
M K Engineers and Contractors
QUALITY CONSTRUCTIONS CO
M/S AMARJIT SINGH
M/S Reliance Construction
M/s SNS Construction
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .