| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Being overall Reasonable | |
| 2 | L2₹27.8 L+₹3.9 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹29.8 L+₹5.9 L (24.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹30.8 L+₹6.9 L (28.8%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹35.4 L+₹11.5 L (48.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINT OF ROOF VALLEY GUTTER CEILING AND ALLIED WORKS IN ZONE A AREA OF AGE BR I UNDER GE CENTRAL KIRKEE
2021_MES_479214_2
8525/E8 2021-2022
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹60,000
Yes
15 Dec 2021
13 Nov 2021
6 Dec 2021
13 Nov 2021
4 Dec 2021
22 Nov 2021
13 Nov 2021 - 20 Nov 2021
60 days
Amount
Dismantling Single layer Mangalore pattern or similar tiles or ridge in roofing complete all as specified and as directed.
Dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and directed.
S & F for 0.63 Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 including dismantling of plain or corrugated steel sheeting any gauge thickness complete all as specified and directed.
S&F roof tiles, Mangalore Pattern, inter locking at side joints laid dry complete all as specified and as directed.
All as per item No 4 above but except Mangalore tiles complete all as directed. (Note: Material shall be used from dismantling)
S&F ridge or hip tiles to suit Mangalore Pattern of roofing tiles bedded and jointed in CM 1:6 complete all as specified and as directed.
All as per item No 6 above but except Mangalore tiles complete all as directed. (Note: Material shall be used from dismantling)
S & F second class hard wood clean sawn battens at 30 cm centre to centre and sectional area exceeding 15 and not exceeding 25 Sqcm including dismantling Battens for tiles ,singles etc of any size including tiling fillets spaced exc.15 cm complete all as specified and as directed.
S & F 2nd class H/W plain fillets, rails, rafters, purlins, square, rectangular in section clean sawn secured with nails brads exc 13 sqcm but n exc 25 sqcm including Dismantling timber scantlings in fillets, rails, posts, rafters, purlins etc under 40 sq. cm in section (Unframed work) in any position complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for plain, galvanised mild steel sheeting in ridges hips valley gutters drip and straight flashing (length and girth as fixed) by using 1.00mm thick sheet grade of zinc coating @120 Gms/Sqm both sides and welded or soldered joints are provided complete all as specified and directed.
S & F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. Fixed with coach screws complete all as specified and directed.
All as per item No 13 above but except AC Sheet complete all as directed. (Note: Material shall be used from dismantling)
Dismantaling timber in scantling 40 sq.cm and over in section in any position and any description unframed work or unframed work complete all as directed.
S&F timber work second class hard wood clean sawn in scantlings, complete all as specified and directed.
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe- 290 (Gde E-165) complete all as specified and directed.
M&L for preparation surfaces of wood and wood based material, new or old of any description and girth and treated with two coats of creosote complete all as specified and as directed.
S & F 2-3mm thick fibre glass reinforced translucent corrugated sheeting with additional reinforcement of chicken mesh with two corrugation side lap fixed with 'L' or 'J' type or cranked hook bolts including dismantling of of existing sheeting of any type complete all as specified and directed.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.
S & F for gypsum reinforced boards 595x595x8 to 10mm thick for ceiling on Hot dipped Galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour all as per manufacture instruction including taking down wall/ceiling boards(fibre, pulp insulation etc) or insulation boards any thickness incl fillets complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified.
M&L 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified.
S&F Anodised aluminium snap grid frame work of size 605X605mm for false ceiling complete all as specified.
S&F Hangers 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L PCC (1:3:6) type C1 (Using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for precast cement concrete block masonry of grade C-5 having density not less than 1800 kg/cum and 28 days average minimum compressive strngth of block should be 5 N/sqmm as in walling set in cement mortar 1:6 complete all as specified and as directed.
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (CM 1:6) complete all as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified of random rubble walling, coursed, hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 40mm on lime/sand stone all as specified and directed.
M&L for Raised pointing to RR masonry in CM 1:4 all as specified and directed.
Taking down cement plaster or cement lime mortar on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and directed.
M & L rendering 10 mm thick on concrete surfaces in CM 1:6, finished the surface even and smooth without using extra cement complete all as directed.
M & L rendering 5 mm thick on concrete surfaces of ceiling in CM 1:3, finished the surface even and smooth without using extra cement complete all as directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:4 mixed with water proofing compound finished even and smooth without using extra cement complete all as directed.(Note: WPC shall be measured and paid seperately)
M & L Dubbing out average 10mm thick on irregular face of stone masonry walls in CM (1:4) complete all as directed.
Supply only Liquid water proofing compound.
M & L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper over a coat of chalk whiting primer complete all as specified.
M & L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying three coats of white wash on ceiling complete all as specified.
M & L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified.
S & F CI pipes fixed to wall or floor 300mm bore including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and as directed.
S & F in repair CI Bends 300mm dia complete all as specified and as directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 150 mm bore including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and as directed.
S & F in repair PVC SWR Bends 150 dia complete all as specified and as directed.
L.K.R.TIWARI CONSTRUCTION
Shri Sant Cosntruction
S.R.M.K Enterprises
M/S SANDEEP H BHINGARDIVE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .