| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.3 L+₹37,315 (2.34%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹16.6 L+₹60,905 (3.82%)Rejected-Finance | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹17.9 L+₹1.9 L (12.2%)Rejected-Finance 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹21.7 L+₹5.7 L (36.0%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
COMPREHENSIVE MAINTENANCE OF EM NATURE OF WORKS IN VIKRAM BATRA VIHAR SUBRAMANIAN LINE NEW OLD CHITRAL LINE BASANTR LINE UNDER GE WEST DELHI CANTT 10
2023_MES_587076_1
GE/DW-50/2023-24
Open Tender
Civil Works
Item Rate
270 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST DELHI CANTT
₹80,000
19 Jul 2023
10 May 2023
31 May 2023
10 May 2023
29 May 2023
24 May 2023
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power/call bell) complete and making good the disturbed surfaces of wall/floors/ceiling etc) and all fitting fixtures deposited to MES store Yard complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed /surfaceconduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing switches/sockets etc with cover plate/3mm thick plastic laminated sheet for the foiiowing complete all as specified and directed. :- (a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) one light point controlled by 2 way switches complete all as specified and directed
All as per item No. 2.0 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S & F in Repair of socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
S & F in Repair of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S & F in Repair of Bell push single pole one way complete all as specified and directed.
S & F in Repair of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S & F in Repair of Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S & F in Repair of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
S & F in Repair of two way switch complete all as specified and directed.
M&L in repair louver shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
S&F in replacement MCCB 4 pole 125 Amp, Icu = 16 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed.
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB DP 32 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
M & L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, burieddirectly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 2009, connected to earthing test point, earth lead protected by medium grade 15 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 B-1 ( including excavation and earth work, disposal of surplus soil to a distance not exc. 50 Mtrs) all as specified and shown on plate No 5 of SSR – Part I 1991. Note:-(a). PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (b). RCC pit cover shall be of pre-cast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover all as specified or indicated including testing on completion all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
S&F in repair call bell electric 240 volts, AC supply, Ding Dong type complete all as specified and as directed.
S&F replacement of lamp holder 240 Volt AC pvc/polycarbonate type with back plate complete all as specified and directed.
S&F replacement of ceiling rose3 phsae 240 Volt AC pvc/polycarbonate isolated body complete all as specified and directed.
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 3. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contracror shall arrange suitable T&P such as Drill machine/cutter machine incl necessary for work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at AGE B/R-II & III for collection of complaints from the concerned JE in charge . 7 Job slip & Complaint Register including stationary items as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacityshall be issued by the department free for fixing and labour shall be paid unde respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site against issued by the department to be deposited to MES store Yard. 12. The number of workers are required to be increased based upon number of complaints and quantum of work involved and during emergencies irrespective of working hours as decided by GE/Engr-in-Charge. 13. The number of workers are required to be increased based upon number of complaints and quantum of work involved and during emergencies irrespective of working hours as decided by GE/Engr-in-Charge. 14. The work inclludes attending complaints related to repair/replacement of parts and fixing of supply only items as enlisted in Sch'A' part-II including replacement of switches,sockets,ceiling roses,fan regulator,MCBS,LED fittings,elctic bell,holder,fan bearing,geyser element,CP connection,NEV of geysers,capacitors etc and all other electric works required to keep them fully functional to the entire satisfaction complete all as spd & directed by GE/Engr-in-charge 15. Labour charge for supply only items (26 to 70 except 58,59 &61 of BOQ), will be paid under this items.
Supply only of MS down rod 300/450 mm for fixing of ceiling fan all as specified and directed
Supply only of Ceiling fan blade 1200mm sweep for fixing of ceiling fan all as specified and directed.
Supply only MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm swwep ceiling fan complete all as specified and as directed.
Supply only PVC connection with brass nippleof size 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25 lit capacity geyser as hot and cold connection complete all as specified and directed.
Supply only of inner shell Stainless steel body suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of Copper Heating Element 1500 /2000watt including assenbly suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of thermostat suitable to work at water temperature 30° to 75° C electric cut up for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only of Indicating lamp (red/green/yellow) complete suitable for Bajaj or as per site requirement as directed by JE/Engr-in-charge Geyser of 25 Ltr capacity complete all as specified and directed.
Supply only 15A plug top 240 Volt AC and connection complete all as specified and as directed
Supply only in Repair of socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
Supply only of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Supply onlyof Bell push single pole one way complete all as specified and directed.
Supply only of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
Supply only of Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply onlyof ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
Supply only of SS combined 15 amp without Box complete all as specified and directed by Engr-in-charge
Supply only SS combined 15 amp with Box complete all as specified and directed by Engr-in-charge
Supply only SS combined 5 amp without Box complete all as specified and directed by Engr-in-charge
Supply only SS combined 5 amp with Box complete all as specified and directed by Engr-in-charge
Supply only call bell electric 240 volts, AC supply, Ding Dong type complete all as specified and as directed.
Supply only PVC flexible two core copper 1.5 sqmm size multi stgranded FRLS PVC insulated complete all as specified and directed.
Supply only three core copper conductor 2.5 sqmm size multi stgranded FRLS PVC insulated complete all as specified and directed.
Supply only Single core copper conductor 2.5 sqmm size multi stgranded FRLS PVC insulated complete all as specified and directed.
Supply only Single core copper conductor 1.5 sqmm size multi stgranded FRLS PVC insulated complete all as specified and directed.
Supply only Single core copper conductor 4.0 sqmm size multi stgranded FRLS PVC insulated complete all as specified and directed.
Supply only Single core copper conductor 6.0 sqmm size multi stgranded FRLS PVC insulated complete all as specified and directed.
Supply only saddle for fixing of conduit pipe as per site requirement complete all as specified and directed.
Supply only LED LAMP 9 Watts 6500 K pin type allspecfied and directed
Supply only tube light fittings 20 watt 6500 K 4 ft allspecfied and directed
Supply only tube light fittings 10 watt 6500 K 2 ft all specfied and directed
Supply only Bulk head light 6500 K ,IP, 65 versatile pressure die cast 10 watt all specfied and directed .
Supply only ceiling fan capacitor for 1200/1400 mm sweep 2.5 mfd all specfied and directed
Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store and refixng the same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, capacitor,Bearing, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed.
Supply only canopy for ceiling fans (Set of two) complete all as specified and as directed.
M&L for rewinding exhaust fan of 300 mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
Supply only energy saving and environmental friendly long life versatile pressure die cast aluminium IP-65 security light luminaire with high power 25 watt LED security light complete all as specified and directed.
Supply only lamp holder 240 Volt AC pvc/polycarbonate type with back plate complete all as specified and directed.
Supply only ceiling rose3 phsae pvc/polycarbonate isolated body complete all as specified and directed.
Supply only 3 mm thick hylum sheet 9x11 including cutting of suitable for switch/socket/regulator complete all as specified and directed.
Supply only 3 mm thick hylum sheet 8x5 including cutting of suitable for switch/socket complete all as specified and directed.
Supply only 3 mm thick hylum sheet 5x5 complete including cutting of suitable for switch/socketall as specified and directed.
Supply only metal thick sunken box 4x4 including brass scews and cup complete all as specified and directed.
Supply only metal thick sunken box 8x10 including brass scews and cup complete all as specified and directed.
Supply only metal thick sunken box 7x4 including brass scews and cup complete all as specified and directed.
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB DP 40 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 359045.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum.
SETHI ENTERPRISES
M/s Sohanil Construction
jain associates
S.R. Constructions
M/s Krishna Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .