| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹9.4 L+₹1.7 L (22.7%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST. | |
| 3 | L3₹9.8 L+₹2.2 L (28.7%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L3 | Rejected-Finance NOT BEING LOWEST. | |
| 4 | L4₹10.0 L+₹2.3 L (30.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST. |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
CERTAIN/REPAIR/REPLACEMENT TO LT DISTRIBUTION SYSTEM, LT UG CABLES, LT PANEL, MISC ITEM AND ITS CONNECTED E/M WORK AT AF STN BKT
2020_MES_377547_1
8431/BKT/E8
Open Tender
Civil Works
Item Rate
240 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹20,000
Yes
15 Oct 2020
14 Sept 2020
12 Oct 2020
14 Sept 2020
10 Oct 2020
28 Sept 2020
60 days
Amount
Excavation in trenches not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling insoil in soil spreading, levelling, watering and well ramming in layers n.exc 25 cm. complete all as directed.
Removing surplus excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation. Complete all specified & directed (Note - Please note punned thickness shall be measured).
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable across the trenches complete all as specified.
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
Supply and laying GI tube medium grade 80 mm bore complete for pretection of cable etc complete including socket if required all as specified and directed.
Ditto all as item No 7 here-in-before but 40 mm bore.
Taking out old serviceable /unserviceable under ground cable of following sizes from trenches/poles /pipe/floor of size 25 Sqmm 3.5 core to 35 Sqm core.
Dittto to item No 09 here in before but 50 Sqmm 3.5 core to 120 Sqmm 3.5 core.
Ditto to item No 09 here in before but 240 Sqmm 3.5 core.
Supplying, laying, passing through pipe, connecting and testing UG cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 grade of size volts 25 Sqmm 3.5 core (Note- Excavation,Earth work,pipe ect will be measured & paid sepretely.
Ditto all as item No 12 here in before but XLPE Cable of size 35 Sqmm, 3½ Core .
Ditto all as per item No 12 here in before but XLPE Cable of size 50 Sqmm, 3½ Core
Ditto all as per item No 12 here in before but XLPE Cable of size 70 Sqmm, 3½ Core .
Ditto all as per item No 12 here in before but XLPE Cable of size 120 Sqmm, 3½ Core .
Ditto all as per item No 12 here in before but XLPE Cable of size 240 Sqmm, 3½ Core .
M&L heat shrinkable jointing kit for 1.1 KV grade cable including suitable size of connector complete all as per directed by Engr-in-charge including necessary excavation and earth work , Jointing kit complete, fixing T&P including removing of grass/shrubs nearby the fault location for XLPE cable of size 25 Sqmm to 50 Sqmm x 3.5/ 4 core all as specifed & directed.
Ditto all as per item No 18 here in before but XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core
Ditto all as per item No 18 here in before but XLPE Cable of size 240 sqmm 3.5/4 core
Supply and fixing aluminium thimble , cable gland and lugs after disconnecting from panel and taking down burnt cable from panel of different location and cutting out the burnt portion of cable and extended the cable from cable loop, preparation of cable including necessary connection and testing complete of all as specified & directed of size 25 Sqmm 3.5 core 100 volt grade :- (Note : (i) 01 Job consisting of 04 Nos Lugs/thimble at one end of cable (ii) Rate of necessary earth work for opening of loop if requried at site are deemed to be included in the quoted rate).
Ditto all as item No 21 here in before but for 35 Sqmm 3.5 core 1100 volt grade.
Ditto all as item No 21 here in before but for 50 Sqmm 3.5 core 1100 volt grade.
Ditto all as item No 21 here in before but for 120 Sqmm 3.5 core 1100 volt grade.
Ditto all as item No 21 here in before but for 240 Sqmm 3.5 core 1100 volt grade..
S&F LT volt meter (0-500) digital square flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete all as directed.
S&F in repair 1100 Volts grade LT Ammeter (0 - 300 A) digital squire flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder and taking out of unserviceable Ammeter complete all as directed.
S&F in repair 1100 Volts grade LT Ammeter (0 - 500 A) digital square flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder and taking out of unserviceable Ammeter complete all as directed.
M&L for Spray painting to LT panel board with two coat of synthetic enamel high glow paint as directed including preparation/cleaning of steel surfaces.all as directed by Engr-in-Charge.
S&Fof MCCBs thermal meganitic including necessery fixing arrengement & tasting existing old LT panel board/LT feeder box compresing complete of 200 Amps 4 pole with breaking capacity 36 KA in repair complete all as directed.
Ditto all as item No 30 here in before but 160 Amps 4 Pole breaking capasity 36 KA .
Ditto all as item No 30 here in before but 100 Amps 4 Pole breaking capasity 36 KA .
Ditto all as item No 30 here in before but 200 Amps 4 Pole breaking capasity 50 KA .
Ditto all as item No 30 here in before but 250 Amps 4 Pole breaking capasity 50 KA .
Taking down existing old LT panel board/LT feeder piller box comprising of MCCB & switch fuse unit of any capacity and size including bus bar ammeters. Voltmeter etc after disconnecting all calbe connection and removing from site complete all as directed.
M&L for chemical Earthing with copper earth plate 600 x 600 x 5mm thick buired directly in ground (earth pit not less that 12' deep below ground level ) connected to copper earth strip 32 x 6 mm by means of copper brazing after tighten by bolts, nuts, check nuts and washers of brass from earth pit to test point with protection GI pipe of size 40mm dia light grade and providing masonry enclosure and watering pipe 40mm dia light grade , including wiremesh steel funnel complete with alternate layer of salt crystal (200Kgs), charcol (250Kgs), magnesium sulphate crystal (100 Kgs) in each earth pit, including watering arrangement 200 ltrs for each earth pit all as specifed and directed by Engr-in-charge. (Note : GI strip GI protection pipe upto 7.5 m length is included in the quoted rates from earth pit to test point)
Earthing complete with galvanised steel earth plate 600 x 600 x 6mm thick buired directly in ground (earth pit not less that 2.25mtr deep below ground level ) with top edge of the plate not less than 1.5mr below normal ground level connected to galvanised iron strip of size 25 x 3mm by means GI welding after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 40mm dia light grade and providing masonry enclosure and watering pipe of dia 40mm including wiremesh steel funnel, including watering arrangement 200 ltrs for each earth pitcomplete as specifed and directed by Engr-in-charge . ( Note : GI strip GI protection pipe upto 7.5 m length is included in the quoted rates from earth pit to test point)
S & F for Earth continuity conductor or main earthing lead fixed to wall on batten or fixed on wall of the building on insulator or PVC pipe or chases or buried in ground or fixed to poles or any other indicated situation for loop earthing etc as required of size 25 x 3 mm galvanised aluminium strip complete in repair all as specified and directed by Engr-In-charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or fixed on wall of the building on insulator or PVC pipe or chases or buried in ground or fixed to poles or any other indicated situation for loop earthing etc as required of size 32 x 6 mm copper strip complete in repair all as specified and directed by Engr-In-charge.
M&L for repair of earthing pit with brick work and PCC 1:3:6 including RCC pit cover of size 300x300mmx50mm thick with provision of opening handle complete including necessary watering, ramming and compact of soil near the earth pit all as specified and as directed by Engr-in-charge
M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete including cleaning of grass nearby the LT Panel upto 2mtr all around , necessary earthwork as required all as specified and as directed by Engr-in-charge. (Note : Rate of necessary earthwork as required at site are deemed to be included in the quoted rate)
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 10 Sqmm 2 core complete all as specified & directed.
M&L for Synthetic eletric insulating mat shock proofing of size 2Mx1Mx10mm thick ISI marked all as specified and as directed.
M&L Synthetic eletric insulating shock proofing mat of size 2Mx1Mx12mm thick ISI marked all as specified and as directed.
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacity all as specified and as directed by Engr-in-charge.Note : (i) Necessary eqpt and safety mesures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate.
M&L for on load Chang over switch of capacity 200 Amps , 415 Volts , 4 pole with sheet metal inclosure in repair complete all as specified and directed by Engr-in-charge.
M&L for on load Chang over switch of capacity 315 Amps , 415 Volts with sheet metal inclosure in repair complete all as specified and directed by Engr-in-charge.
M&L for on load Chang over switch of capacity 100 Amps , 415 Volts, 4 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge.
Ajanta Motor Store
Unnati Engineers
AP Electric works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .