Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹53.2 L+₹3.6 L (7.35%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹54.4 L+₹4.8 L (9.77%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹55.3 L+₹5.7 L (11.6%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹55.4 L+₹5.9 L (11.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Kathir Marketing Services L3 | DHAKSHNA MOORTHY AND SON L7 | Ravi Enterprises L2 | SKY GROUP L1 | Tropical Refrigeration L4 | MGP Enterprises L5 | Chandra Construction Enterprises L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of Servo controlled voltage stabilizer (confirming to BIS 9815 (part-I): 1994, reaffirmation 2019 latest version), three phase, four wire (RYBN), 50 Hz, naturally oil cooled, indoor, unbalanced type, copper wound, metallic body duly powder coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification and complete all as specified and as directed:
Make: Krykard/ITE Gurgaon/ Voltamp/ ABB/Schneider/Siemens | 2 | Each | 3,25,000 ₹6,50,000 | 3,39,000 ₹6,78,000 | 3,12,000 ₹6,24,000 Lowest | 3,20,000 ₹6,40,000 | 3,31,200 ₹6,62,400 | 3,32,000 ₹6,64,000 | 3,22,200 ₹6,44,400 |
| 1.01(a) Capacity - 60 KVA (b) Type - Suitable for unbalanced load and unbalanced input. (c) Input voltage - 360V - 480V, input frequency 50 Hz (d) Output voltage - stabilized at voltage 415 ± 1% (e) Rated frequency - 50 Hz (f) Wave form distortion - Nil (g) Response time - not to exceed 20 milli seconds (h) Sensitivity - ± 1% (j) Rate of correction - not less that 6 Volt/ second between phase and neutral (k) Efficiency - more than 95% (l) Type of load - Three phase, unbalanced type (m) Metering - Digital display Voltmeter/ Ammeter with multi-function meter (n) Operating temparature - upto max ambient temp + 55º C (o) Dimmer rating (Amp) - suitable for 400 KVA rating voltage stabilizer. (p) Dimension of tank - as per OEM design. (q) Oil capacity (Ltrs) - as per OEM design. | ||||||||||
| 1.02(r) Class of insulation - Class F (s) Mode of operation - Automatic/ Manual (t) Winding temparature rise - Max 55º C (10º C above operating temparature) (u) Transformer oil - IS 335 marked (v) Core - CRGO M4 grade/ CRNO (w) Auto transformer (Variac) - 100 percent copper wound Electrolytic grade (x) Losses - The tolerances on no load and full load losses corresponding to minimum and maximum rated input voltage shall be provided in Table 7 of IS 2026 (Part I). (y) Power factor - Not less than 0.95 (z) Protection - Overload protection, Short circuit protection, High/Low voltage cut off, By pass arrangement in case of emergency, Single phase sequence change/ phase fail protection & Earth fault protection. (aa) Standard fitting & Accessories e.g Marking plate, lifting lugs, CI Rollers, Earthing terminal and cable box etc. | ||||||||||
| 1.03Note: a) The Contractor shall make all necessary arrangements for pre-despatch inspection at manufacturer site or e-testing as directed by Accepting Officer and for pre-commissioning test by SEI/EI/ ESO or any testing officer as nominated by HQ CE (A&N) Zone through Accepting Officer after installation of voltage stabilizer. The cost for the same is deemed to be included in quoted rate. b) The voltage stabilizer to be erected indoor, inside sub-station building. The cost of voltage stabilizer foundation as per OEM recommendation shall be deemed to be included in the quoted rate. The rate quoted is also inclusive of making good distributed flooring/ surfaces all as directed. (c) First fill of Transformer upto the marked level shall be deemed to be included in the quoted rate. | ||||||||||
| 2.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core of complete all as specified and as directed by Engineer-in-Charge. | 30 | RM | 830 ₹24,900 | 832 ₹24,960 | 822 ₹24,660 | 820 ₹24,600 | 840 ₹25,200 | 840 ₹25,200 | 811 ₹24,330 Lowest |
| 3.00 | Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm polythylene including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge. | 20 | RM | 395 ₹7,900 | 365 ₹7,300 | 365 ₹7,300 | 340 ₹6,800 Lowest | 410 ₹8,200 | 410 ₹8,200 | 622 ₹12,440 |
| 4.00 | Supply, installation, testing & commissioning of 4P, 415 volts, 50 Hz, 160 Amps motorised change over automatic transfer switch with controller, LED actuator push buttons, motorised change over, enclosure made up of sheet metal/ polycarbonate body with minimum IP 40 protection having provision for selection of manual and auto mode operation including, protection against over voltage/ under voltage, phase sequence, single phasing taking down defective switch complete all as specified and as directed.
Note: The quoted rate shall be deemed to be inclusive of necessary supporting angle iron frame work as specified by Engineer-in-Charge for mounting transfer switch without any wall support. | 2 | Each | 1,20,000 ₹2,40,000 | 1,23,000 ₹2,46,000 | 1,25,000 ₹2,50,000 | 1,00,000 ₹2,00,000 Lowest | 1,23,000 ₹2,46,000 | 1,23,000 ₹2,46,000 | 1,18,200 ₹2,36,400 |
| 5.00 | Supply and fixing plug in box of sheet metal enclosure and in built neutral link for TPN system of MCCB 100 Amps, 4 Pole, 36 KA of IK08 and IP 42 protection complete all as specified and as directed by Engr-in-charge. | 2 | Each | 65,200 ₹1,30,400 | 65,300 ₹1,30,600 | 66,200 ₹1,32,400 | 6,500 ₹13,000 Lowest | 65,300 ₹1,30,600 | 65,300 ₹1,30,600 | 64,120 ₹1,28,240 |
| 6.00 | Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead, 20 mm dia GI pipe for watering and earth plate surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board/ transformer neutral and testing on completion as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 450 x 450 x 100 mm with one handle made out of 8 mm dia round bar, wire mesh and testing complete all as specified and as directed.
Note: (i) Cost of GI earth Strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.
(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. | 4 | Each Job | 12,500 ₹50,000 | 12,500 ₹50,000 | 12,400 ₹49,600 | 12,000 ₹48,000 Lowest | 12,650 ₹50,600 | 12,650 ₹50,600 | 12,400 ₹49,600 |
| 7.00 | Supply & fix GI strip 32mm x 6 mm buried in ground / fixed inside duct complete all as specified and as directed by Engineer in Charge | 10 | RM | 290 ₹2,900 | 295 ₹2,950 | 230 ₹2,300 Lowest | 230 ₹2,300 Lowest | 312 ₹3,120 | 312 ₹3,120 | 255 ₹2,550 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Jul 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8608/E8- PROVN OF HIGH MAST 16 MTR LIGHT AND CONNECTED E/M WORK AT VAYU VIHAR CHILDEREN PARK AF STN, PROVN OF DEFICIENT KITCHENETTE ATTACH WITH ADMIN BLOCK P-239 AT NT POOL AND CERTAIN REVENUE AND MINOR WORKS UNDER GE MINNIEBAY, SRI VIJAYA PURAM
2025_MES_715172_1
8608/E8
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
13 documents required · 13 mandatory
₹500
Yes
GE, Minniebay
₹96,000
Yes
22 Oct 2025
18 Jun 2025
11 Jul 2025
18 Jun 2025
9 Jul 2025
2 Jul 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .