Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.7 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹23.8 L+₹82,670.49 (3.60%)Rejected-Finance 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹25.8 L+₹2.8 L (12.2%)Rejected-Finance | 3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | 4₹26.5 L+₹3.5 L (15.2%)Rejected-Finance | 4 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Sept 2024, 6:55 pmClosed
GE Chennai
GE Chennai 600009
REPAIRS TO INTERNAL/EXTERNAL WALL PLASTERING, CHAJJAS, SEEPAGE TREATMENT TO EXTERNAL WALL ETC AND CONNECTED WORKS UNDER ZONE A and C OF GE CHENNAI
2024_MES_668446_1
8754
Open Tender
Civil Works
Item Rate
273 days
GE Chennai
As per tender documents
7 documents required · 7 mandatory
₹500
GE Chennai
₹50,000
Yes
9 Dec 2024
31 Aug 2024
5 Oct 2024
31 Aug 2024
28 Sept 2024
14 Sept 2024
Amount
M&L for Preparation of Existing surfaces of walls/chajjas/facia etc in patches to remove all dirt, mildew and other contaminants. Treat areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely.. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modified mortar or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP. Priming using Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2parts Prime seal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coats of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for walls at the thickness of 120 – 130 microns all as specified and directed . Note: All above treatment will be measured as one unit of square metre and paid accordingly.
Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc, and removing unserviceable material outside cantt area, complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for fly ash brick work with sub class B bricks straight or curved on plan exc 6M mean radius built in CM 1:4 complete all as specified and directed.
Gl wire netting 0.90mm dia & 12mm mesh in patches of lathing to wood or metal studding, joists, etc. in walls. Ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified and directed.
Dubbing out average 15mm thick on irregular face of walls in patches in CM (1:4) complete all as specified and directed.
15 mm thick rendering on fair faces of brick work or concrete surfaces of walls etc 10 mm thick in CM 1:6 and 5 mm thick in CM 1:4 incl water proofing compound as per manufacturers instruction & finished the surfaces even and smooth without using extra cement, complete all as specified and directed. note : WPC WILL BE MEASURED AND PAID SEPERATELY
Supply only Liquid water proofing compound complete all as specified and directed.
15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick using CM (1:3) on ceiling, in patches surfaces finished the surfaces even and smooth without using extra cement all as specified and as directed.
M & L for applying three coat of white wash as in ceiling incl preparation of newly plastered ceiling surfaces all as specified and as directed.
Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered /treated surfaces of walls all as specified and as directed. Make : APEX of Asian or equivalent of Shalimar / Nerolac/ Berger.
Material and labour for applying three coats of white wash on walls including preparation of newly plastered surfaces complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B complete all as specified and directed.
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
S&F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe-410- W(Gde- E-250) quality- B(cut to ordinary lengths i.e. Within 20mm of the length indicated) complete all as specified and directed.
M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surface based materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and directed.
Cutting holes into or through brick walls but in brick walls superficial area n.exc 150sqcm built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l complete all as specified and directed.
Cutting holes into or through brick walls built in but in brick walls area exc 150 sqcm but n.exc 400 sqcm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and directed.
Cutting holes into or through brick walls built in but in brick walls area exc 400 sqcm but n.exc 0.1 sqm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l complete all as specified and directed.
Preparation of new steel surfaces and applying two coats of black bituminous paint all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Material and labour for mild steel deformed TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings, fins, louvers, fascia and similar work including attached pilasters, buttresses,etc.; vertical or to batter flat fair finished complete all as specified and directed.
M&L reinforced cement concrete type A1 1:1.5:3 using 12.5mm graded aggregate(Nominal mix design) for Fins, fascias, louvers, parapets, landings and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed.
M&L brickwork with fly ash bricks, cornices in patches built in CM 1:3 and making splayed, bull-nosed or any other type of purpose-moulded complete all as specified and directed.
PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints fixed to walls /floor as in spouts etc complete including dismantling existing pipes all as specified and directed.
PVC (SWR) pipes 75mm single socketed, in any length with rubber ring joints fixed to walls /floor complete as in spouts etc including dismantling existing pipes all as specified and directed.
PVC (SWR) bends with oval access door 110mm fixed in repairs complete all as specified and directed.
PVC (SWR) bends with oval access door75mm fixed in repairs complete all as specified and directed.
PVC (SWR) vent cowl 110mm fixed in repairs complete all as specified and directed.
PVC (SWR) junction single (single T ) equal or un equal with access door75 mm fixed in repairs complete all as specified and directed.
PVC (SWR) junction single (single T ) equal or un equal with access door110mm fixed in repairs complete all as specified and directed.
SIRITEL SYSTEMS PRIVATE LIMITED (BID ID -3100508)
ARK Enterprises (BID ID -3101133)
A V ENGINEERING (BID ID -3102398)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .