EE(E)BCP
MTNL T.E. building Bhikaji Cama Place, New Delhi
Please refer Tender documents.
2022_MTNL_679176_1
EE(E)BCP/MTNL/NIT/2021-22/94
Open Tender
Miscellaneous Works
Item Rate
365 days
New Delhi
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
MTNL
₹39,758
26 Mar 2022
16 Mar 2022
25 Mar 2022
16 Mar 2022
24 Mar 2022
16 Mar 2022
90 days
Amount
Supply & fixing of G. I. sheet metal ducting for air supply, mixing, air distribution, complete with following thickness (gauge) i/c nut bolts, gaskets, suspenders, supports etc. as required. a) 24 gauge G. I. Sheet
b) 22 gauge G. I. Sheet
c) Canvass connection with fire resistance cloth complete as reqd.
Providing & fixing of following size of powder coated Aluminium construction supply/return air grill or Diffuser with 60% free area etc. complete as reqd. a) Supply air grill/ diffuser with volume control damper for room ( Size: As per requirement, area :less than or equal to 4 sqft.)
b) Return air grill / Diffuser (Size: As per requirement, area :less than or equal to 4 sqft.)
c) Pdg. & fixing of air grill for ductable indoor unit of suitable size complete as reqd. (Size upto 4 Sqft.)
Supply & fixing of following type of damper made out of 18 gauge CRC/GI sheet used as fire damper, supply air damper or return air damper in main duct or branch duct or in return air path as per site requirement. i/c nut bolt, gasket etc. as required. a) Fire damper (Size: As per requirement, Area:less than or equal to 9 sqft.)
b) Volume control damper for supply air grill /diffurers ( Size: As per requirement, area :less than or equal to 4 sqft.)
c) Volume control damper for package indoor / ductable indoor units/duct
a) Supplying 6mm thick Metallic faced kini foam insulation & fixing with manufacturer recommended adhesive the following insulation on duct/ wall/ ceiling or roof etc. complete as reqd.
b) Pdg. & fixing Kini foam insulation / 9mm thick FR XPE pipe section insulation for refrigerant piping.
Pdg. & installing following size copper pipe including cutting bending, jointing, brazing etc as reqd. for hot suction and liquid refrigerant line complete as reqd. a) 7/8"
Pressure testing with nitrogen, pressure standing for at least 8 hr., vaccumzing & commissioning with appropriate refrigerant for following A C units complete as reqd. a) 11.0 TR AC unit
b) 8.5 TR AC unit
c) 7.5 TR AC unit
d) 5.0 TR AC unit
Supplying and filling the following refrigerants. a) R-22 gas charging/ gas top up
b) 403 gas charging/ gas top up
Pdg. & fixing following type of filter having 85% efficiency down to 20 microns suitable to fit in the ductable unit / package unit/duct/plenum at the supply air/return air path complete as reqd. a) Return air filter for A.C. units
Supplying, laying, fixing, testing and commissioning of following sizes PVC sheathed copper conductor cable on the existing surface as reqd. a) 4 x 10 Sq. mm Copper Armoured cable.
b) 4x1.5 Sq. mm
c) 17 Core unarmoured Cable
d) 2 x 16 Sq. mm Copper Armoured cable.
e) 3x2.5 sq.mm copper conductor flexible cable
Fabricating & installing of following size cable tray made out with M. S. Slotted angle & square pipe or slotted sheet material i/c nut-bolt, screw, supports and suspenders etc. for cable/ refrigerant piping complete as reqd. a) size up-to 200 mm width
b) size above 225mm width & up-to 300mm width
c) Width size not exceed 150mm
Supplying & laying of 8 SWG. GI wire on surface or on recess for loop earthing on the existing surface /Recess with main power cable etc. as reqd.
M. S. Structure work for i/c designing, fabricating at site as per site requirements i/c cutting, welding, fixing, painting with one coat of red oxide primer and two coats of enamel paint in approved shade etc as reqd. a) 40mm x 40mm x 5mm M. S. Angle iron.
b) 9mm M S rod
c) M.S. Frame (stand type)/foundation for outdoor units of 5.0TR to 5.5TR ductable/package a.c. units complete as reqd.
d) M.S. suspenders for indoor units of 5.0TR to 11TR ductable/package a.c.units complete as reqd with the help of heavy labour/ trolly etc
Providing & making drain arrangement for A/C units with following pipe i/c Tee, Union, Socket & Elbow etc as reqd. (uPVC hard medium class) a) 25 mm dia (NB)
b) 32 mm dia (NB)
Providing & fixing of drain tray of 5.0/7.5 TR ductable AC unit
Pdg. & fixing Micro processor controlled system in a metal enclosure operating on 220V ,single phase A C supply for controlling the A C units in such a way that only one A C unit ,out off two A C units will operate at a time for a fixed period of time and there after next A c unit start operating and so on i/c system make closed loop in case of fault comes in the unit complete as reqd.
Pdg. & fixing automatic phase correction system for ductable A C unit which should work in such a way that as the series of phases changed from the 3 phase A C supply it will work and make the series phase correct so that the A C units operation does not effect i/c its wiring or providing & fixing of power saver i/c its wiring for 5.0 TR to 7.5 TR AC plant complete as reqd.
Providing & fixing of following insulation/ accoustic/ partition work as per site requirement for duct, wall, room, false ceiling or roof i/c painting with black jaipan paint, screw, nut bolt (IF reqd.) and grid size if required not less than 1200mm x 600mm with rectangle pipe/ MS angel or channel/ slotted angel etc complete as reqd. with the following materials. a)Pdg. & fixing duct insulation with 6mm thick closed cell fire retardant insulation.
Pdg. & fixing automatic phase correction system for ductable A C unit which should work in such a way that as the series of phases changed from the 3 phase A C supply it will work and make the series phase correct so that the A C units operation does not effect i/c its wiring or providing & fixing of power saver i/c its wiring for 5.5 & 11.0 TR ductable/ Package AC plant complete as reqd.
Dismantling of old package/ductable/split AC units i/c all associated works like ducting, piping, cabling, trays ; shifting the same to the store / designated location within the building premises as per the instructions of the engineer-in-charge. with the help of crane/chain pully block & heavy labour
Lifting & shifting of A.C units with the help of heavy labour & chain pully block from ground floor to the floor where the A C plant room is situated complete as reqd.
Shifting of dismantled AC unit along with all accessories to another site under jurisdiction of EE(E) BCP with the help of heavy labour and chainpully, transportation etc. as reqd.
Minor civil work/Wall opening/pota cabin cutting and making good/sealing complete as reqd.
Pdg. & fixing of electrical/mechanical switchgears complete as reqd. a) 63amp TPN MCB
b) 100amp TP MCCB of 25KA Breaking capacity (Make-M/s L&T/GE/Legrand/C&S/ABB)
c) 200amp MCCB
Pdg. & Fixing PVC flooring i/c cleaning of floor spreading the adhesive, pasting the PVC sheet rolling with weight on the pasted sheet for proper fixing complete as reqd.
Provision of color coding of copper pipe with suitable color paint.
SITC of R.A. boxing made of 6 mm water proof ply, slotted angle, fixing with fasteners nuts & bolts etc.
Providing MS wiremesh work with enamel paint and redoxide complete as reqd.
AC Guard CP-Corrision prevention coating for brazing joints, U band, interconnecting copper piping of indoor and outdoor a.c. units. (Note: Per Job Per Unit)
Pdg. & Fixing of mechanical item of package/ductable AC unit & other works complete as reqd. a) Angel valve/pin valve for ref. circuit.
b) Drier for AC unit
c) 2.5 TR scroll compressor suitable for Carrier/BSL/LG/ Voltas/ Hitachi make 5.0TR AC unit (Make : Carrier/ Kirloskar/ Copeland)
d) 3.75TR /5.5TR scroll compressor suitable for Carrier/BSL/ LG/ Voltas/ Hitachi Make 7.5TR/ 11.0TR AC unit (Make : Carrier/Kirloskar/Copeland)
e) 8.5TR scroll compressor
f) cooling coil for 11.0TR AC unit
SITC of control wires remote indication suitable for carrier 5TR/7.5TR control kit of carrier panel.
SITC of blower motor of 7.5TR AC unit
SITC of condenser fan motor for AC unit
SITC of condenser motor capacity of 8MFD
SITC condenser fan for carrier make 7.5TR/5.0TR Unit
SITC of blower fan of carrier make 7.5TR/5.0TR unit
SITC of Control scanner or indication of reverse phase, high voltage etc. complete as reqd.
SITC of out door of 5TR ductable AC units for carrier make suitable for ref. CKT & 3 phase supply.
SITC of out door of 7.5TR ductable AC units for carrier make suitable for ref. CKT & 3 phase supply.
SITC of remote control or indication of on/off position of AC unit etc. complete as reqd.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .