Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 12 B NIKKA SINGH COLONY RAM TIRATH ROAD AMRITSAR PUNJAB | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 12 MARUTI NAGAR SIKKA HANUMAN MANDIR SIKKA SIKKA JAMNAGAR GUJARAT 361140 | JAMNAGAR | GUJARAT | 361140 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical 79 B BLOCK SRI GANGANAGAR 335001 RAJASTHAN | GANGANAGAR | RAJASTHAN | 335001 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
11 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR /MAINT OF ROOFING, SUNKEN, PLASTERING, INCLUDING PLUMBING WORK, PERIODICAL SERICES, JOINERY AND OTHER MISC WORKS IN CERTAIN JCOs/OR ACCN AT JS ENCLAVE AND MES COLONY INCL PRE MAP AND MAP MD ACCN AT SRI GANGANAGAR MIL STN
2025_MES_731684_2
CA NO CWE SGNR/TOKEN-51 OF 2025-26
Open Tender
Civil Works
Item Rate
GE SRI GANGANAGAR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE SRI GANGANAGAR
₹2 L
Yes
10 Aug 2026
27 Nov 2025
12 Dec 2025
27 Nov 2025
11 Dec 2025
4 Dec 2025
Dismantling of brick tiles or terracing tiles single layer on roof including also taking down existing APP membrane & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified & directed by Engr-in-Charge.
Demolition of mud in roof, any thickness any type of soil including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 150m, complete all as specified & directed by Engr-in-Charge.
M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth without using extra (Minimum thickness of concrete should not be less than 50mm at any point) complete all as specified & directed by Engr-in-Charge. Note : Waterproofing compound should be measured and paid separately.
Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as specified & directed by Engr-in-charge. Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STP
S&Fin repair Framed work such as grills, gratings coolar stand, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in roof kerbs / benching / coved fillets etc rounded or chamfered on edges, complete all as specified & directed by Engr-in-Charge.
Demolition of RCC of any descrition such as Kitchen chimney, chajja, shelves, OHT Tanks, column , post, pillar etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs,landings,balconies,deck slab and in shelves and etc and setting in mortar complete with joints to match complete all as specified & directed by Engr-in-Charge.
Use and waste of form work through finished surface of soffits of suspended slab as roof slabs, floor, lamnding and similar work not exceeding 200 mm thick complete all as specified & directed by Engr-in-Charge.
M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified & directed by Engr-in-Charge.
All as per item No 10 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified & directed by Engr-in-Charge.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified & directed by Engr-in-Charge.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified & directed by Engr-in-Charge.
M&L half brick work with sub class B bricks straight or curved on plan to any radius in cm 1:4 etc. complete all as specified & directed by Engr-in-Charge.
Taking up or down GI tubing 20 mm bore pipe for refixing and removal to store complete all as specified and directed by Engineer - in - Charge. .
Taking up or down GI tubing 15 mm bore pipe and removal to store complete all as specified and directed by Engineer - in - Charge. .
Refixing 20 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified & directed by Engr-in-Charge.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified & directed by Engr-in-Charge.
Supply & Fixing of 20mm outer dia CPVC pipes SDR 11 including all fittings plain/brass threaded CPVC SDR 11 fittings (like Elbow, Tee, Socket, Reducer, Union, Bushing step over bends end cap, End plugs, one side brass brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified & directed by Engr-in-Charge.
Dismantling PVC water tanks and removing for capacity exceedin 250 litres & not exceeding 500 litres etc.complete all as specified & directed by Engr-in-Charge.
Dismantling PVC water tanks and removing for capacity exceedin 500 litres & not exceeding 1000 litres etc., complete all as specified & directed by Engr-in-Charge.
Refixing 500 Litre ltr capacity Rotational moulded polyethylene water storage tanks , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe including cleaning, complete all as specified & directed by Engr-in-Charge.
Fixing only 500 ltr capacity Rotational moulded polyethylene water storage tanks , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe complete all as specified & directed by Engr-in-Charge.
Fixing only 1000 ltr capacity Rotational moulded polyethylene water storage tanks , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe complete all as specified & directed by Engr-in-Charge.
S&F 20 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified & directed by Engr-in-Charge.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, all as specified and as approved by GE/Engineer-in-Charge.
Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified & directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including PVC holding clamps, complete all as specified & directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) bend, any radius with access door complete all as specified & directed by Engr-in-Charge.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
Water proofing treatment to sunken slab and adjoining vertical surfaces as specified under:- (a) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound as per manufacturer's instruction trowel even and smooth with steel trowel on sunken surfaces Note : (a) WPC shall be measured and paid separately (b) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer. (c) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation. (d) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.
Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab as described following any one complete as per dirns of GE. Note :- Plan area only measured of toilets for payment purpose. Method 1 Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications.(B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck le
vel shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment. Method 2 Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls.(C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment. Make : Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in make as approved by GE Note :- (i) The treatment shall be carried out by authorised applicator (through specialized agency ) approved by GE as per the manufacturer.(ii) PCC filling under sunken area will be measured & paid separately (iii) Treatment should be conitue upto 450mm height on vertical wall of sunken but only plan area of sunken will be measured for payment.
M&L 40 mm GI pipe medium grade, made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified & directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified & directed by Engr-in-Charge.
M&L Non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm. including 15 mm thick Screed bed or bedding layer in CM (1:4) etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & directed by Engr-in-Charge. Note : Using only course sand in screed bed..
S&F glazed ceramic coloured tiles 300x600x7-8 mm thick in size in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. including 10 mm thick rendering in cement mortar 1:4 as in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & directed by Engr-in-Charge. Note :- Rendering will be done in course sand (Toka sand) onlyetc complete all as specified.
Supply and fixing hard drawn steel wire fabric not exc 4kg/sqm cut to lengths, wire mesh to be fixed and firmly anchored to the concrete surface by means of 'L' shaped mild steel shear key welded with existing reinforcement including cost of material, labour, tools, and plants incl welding/L-clip/typing with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer in Charge.
Material and labour for mild steel ISMB, Joist, channel, angle or teee sections, fixed adjacent to ceiling and embedding in floor and brickwork including cutting welding, without connection plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated) FE 410 W(GdeE-250) quality 'A' complete all as specified and directed by Engineer-in-Charge.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, brass chromium plated Jet shower with one meter long flexible pipe including all connection complete all as specified & directed by Engr-in-Charge.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified & directed by Engr-in-Charge.
M&L for rendering 10 mm thick in patches in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified & directed by Engr-in-Charge.
M&L 5mm thick, rendering in cement mortar 1:3 to ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair face of brick work of walls, mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified & directed by Engr-in-Charge. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for applying two coat of white wash on newly plastered surface of ceiling over a coat of wall putty to make the surface even and smooth etc complete all as specified & directed by Engr-in-Charge.
M&L for prepration of New plastered External wall surface complete applying the following :- (a) Applying two coat wall care putty on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified (b) Applying one coat of Exterior Wall Primer by using Roller over complete all as specified (c) Applying two coat of Dust Proof Emulsion using Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible
M&L for prepration of New plastered Internal wall surface complete applying the following :- (a) Applying two coat wall care putty on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directedcoomplete all as specified (b
M&L 10 mm thick, rendering in cement mortar CM 1:3 to work in isolated widths or in widths not forming part of general plastering such as brick/concrete faces of chajjas,facia,window jambs,sunshade and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
) Applying one coat of internal Wall Primer by using Roller over complete all as specified (c) Applying two coat of interior Premium Emulsion Roller over complete all as specified Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible
Supply only integral liquid water proofing compound complete all as specified and directed. Make : Pidilite/Sika/Dr Fixit or equivalent
M&L for applying acrylic wall care putty on new plastered internal/External surfaces of walls/ceilings/soffits in two coat of thickness 1.0 mm as required for desired smoothness and levelling of surfaces in two or more layers by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE /Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified & directed by Engr-in-Charge.
M&L for applying acrylic thick wall care putty on internal/external wall surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE /Engineer-in-Charge.
Preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion complete all as specified & directed by Engr-in-Charge.
Preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion complete all as specified & directed by Engr-in-Charge.
Preparation of surfaces and applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceilings surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion complete all as specified & directed by Engr-in-Charge.
Preparation of existing surfaces and applying 01 coats of exterior emulsion paint (light shade) with highlighter of any existing shade, @ 10 sq.m/litre/1 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion complete all as specified & directed by Engr-in-Charge.
M&L for preparing existing treated surfaces of ceilings including cornices and applying two coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.
M&L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work etc complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of existing treated surfaces on walls/ceilings and applying 01 coat of interior emulsion paint (light shade) @ 20 sq.m/litre/1 coat by using roller to wall/ceiling surfaces including filling wall putty in depressions, sand papering etc and making the surface smooth and applying a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion complete all as specified & directed by Engr-in-Charge.
M&L for preparing new plastered surfaces of ceilings and applying two coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified & directed by Engr-in-Charge.
M&L for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on existing white painted surface complete all as specified and as directed by Engr-in-Charge.
M&L for Writing letters or figures with fluorecent paint ( Block. Roman, Italic or Indian) n exc. 30 cm high etc complete all as specified and directed by Engineer - in - Charge.
M&L for complete removal of existing treatment, preparing steel and iron surfaces of any description/section/trusses/purlins, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on existing yellow/cream painted surface complete all as specified & directed by Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick sorrounds, glazed with oil putty or fixed with beads complete all as specified and as directed by Engr-in-Charge.
S&F sheet glass 3.0 mm thick ordinary quality and glazing with oil putty or glazing pins / spring clip in square, rectangle not exc 0.5 Sqm in each pan complete all as specified and as directed by Engr-in-Charge.
S&F in repair providing precast cement concrete louvres and jallies, 35mm thick (measured solid) cm 1:4 type-B0 1:2:4 (12.5mm) including all mouldings but excluding frame complete all as specified and as directed by Engr-in-Charge.
S&F chicken wire mesh of mesh size 12 mm and wire diameter 1.40 mm for lathing including all laps, cuttings & waste fixing in old RCC slab/beam/chajja complete all as specified and directed by Engineer - in - Charge.
M&L for preparing old painted wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified & directed by Engr-in-Charge.
M&L for preparing old painted wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engr-in-Charge.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc. and removal from site complete all as specified & directed by Engr-in-Charge.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames) complete all as specified & directed by Engr-in-Charge.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each and removal complete all as specified & directed by Engr-in-Charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners deemed to be included in quoted rates.) Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples/ necessar beading required to fixed in wooden door all as specified.including taking down ms frame and refing ms frame with new wire mesh with tinned tack/by welding in steel window/ventilator /door and making good the disturbed portion during execution complete all as specified & directed by Engr-in-Charge.
M & L in repair sheet glass ordinary quality 5 mm thick and glazing with oil putty or fixing using aluminium beadings in square n exc 0.50 Sqm in each panes fixed to steel, metal or wooden/ aluminium window frames complete all as specified & directed by Engr-in-Charge.
d powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners deemed to be included in quoted rates) Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woo
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) abricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners deemed to be included in quoted rates.). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory.
S&F Aluminium Haydraulic door closer springs including roller and roller plate complete all as specified & directed by Engr-in-Charge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. for fixing MosquitoMesh and XTN aluminium mesh combinely panel area of door except stiles and rails to be panelled wire mesh with self tapping rpund headed screws at requrd distance, scres and edge covered with feathered pvc edge beading all around mesh and fixing stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer in- Charge. (a) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf (b) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf (c) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x250mm - 1 nos per leaf (d) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos per leaf Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory.
S & F factory made uPVC sliding window three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm) with or without provision of opening for cooler as directed including all fittings, steel roller system, locking arrangement etc., making arrangement for fixing of hardware, glass, wiremesh, grill etc all as per manufacture instruction and Drg No BTD-890/R . Note:- The unit rate quoted by contractor excludes cost of glass & wire mesh and includes all other connected accessories. Net Opening will be measured for payment purpose. Wire mesh and Glass Shall be measured and paid Seperatly .Provision of all other items as shown on DWgs & Cutting holes of suitable depth in wall for inserting lugs etc including making good dismentalled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggreegate and cement mortar (1:3) shall be deemed to be included Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory.
S & F factory made uPVC window or ventilator side hung/top hung (glazed and gauge both) made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm) including all fittings like hinges, tower blot, peg stay, locking arrangement etc., making arrangement for fixing of hardware all as per manufacture instruction and Drg No BTD-890/R all as specified and directed. Note: The unit rate quoted by contractor excludes cost of glass & wire mesh and includes all other connected accessories. Net Opening will be measured for payment purpose. Wire mesh and Glass Shall be measured and paid Seperatly. Provision of all other items as shown on DWgs & Cutting holes of suitable depth in wall for inserting lugs etc including making good dismentalled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggreegate and cement mortar (1:3) shall be deemed to be include. Note : 1: Test certificate of manufacturer to be provided by contractor . 2. Embossing with barcode of manufacturer engraved over each door frame and shutter is manadatory.
M & L Toughned glass 5 mm thick and glazing with necessary fitting in UPVc window/ventilator complete all as specified & directed by Engr-in-Charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed in UPVC window /Ventilator complete all as specified & directed by Engr-in-Charge.
Dismentling of boarding any description fixed in any position with nails/ screws complete all as specified & directed by Engr-in-Charge.
M&L for plywood, 19/20mm thick, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame work as in Kitchen cup board Shutter / shelves / cabinet etc, complete all as specified & directed by Engr-in-Charge.
M&L for 0.90mm thick decorative laminates 'Mica type 1 of surface finished,colour and pattern as approved, fixed with adhesive also on edges of cupboard shutter as per makers instructions complete all as specified & directed by Engr-in-Charge.
S & F Stainless Steel (304 Grade) Finished Handles 200 mm fixed with ss screw complete all as specified & directed by Engr-in-Charge.
S & F hasp and staple, safety type of aluminium anodised100mm size fixed with screw complete all as specified and directed by Engineer - in - Charge.
Repairing of panel door, skelton door shutter of any categories including taking down ,repairs,refixing in same and other opening type with easing adjusting for proper functioning & including neccesary fitting complete all as specified and directed by Engineer - in - Charge.
Repair of steel winodw & ventilator including welding, handles ,greasing & oiling for proper functioning complete all as specified and directed by Engineer - in - Charge.
M & L for providing door seal made out of extruded aluminium fixing with screw at the bottom of door complete all as specified nad directed by engineer in charge.
S&F 25 mm size magnetic catches with Plastic body and striking plate including letting in and fixed complete all as specified & directed by Engr-in-Charge.
S&F continuous (piano) hinges 20mm & 12 MM width of flap, mild steel bright finish or electrogalvanised fixed with CP steel screws complete all as specified & directed by Engr-in-Charge.
S&F in 150mm length floor door stopper of aluminium alloy body and tongue,anodised with hard drawan steel spring fixed in floor complete all as specified & directed by Engr-in-Charge.
Cutting holes in brick walls exc half brick but not exc one brick thick in cement mortar for inserting holdf asts and making good dismantled portion in cement mortar 1:3 and cement concrete 1:2:4 Type B-1 complete all as specified and directed by engineer in charge.
S&F in repairs chromium plated mortice lock with four lever (vertical type) with brass body 150 mm long comp
lete all as specified and directed by Engineer-in-charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_830663.xls
BOQ • 0.34 MB
Tender51.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .