Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.5 CrAccepted-AOC NOT APPLICABLE | FARIDABAD | HARYANA | 121004 | ₹8.5 Cr | 1 | Accepted-AOC awarded |
| 2 | 2₹8.6 Cr+₹17.2 L (2.04%)Rejected-Finance | ₹8.6 Cr+₹17.2 L (2.04%) | 2 | Rejected-Finance high bidder |
| 3 | 3₹8.8 Cr+₹32.8 L (3.87%)Rejected-Finance | ₹8.8 Cr+₹32.8 L (3.87%) | 3 | Rejected-Finance high bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical will be technically disqualified. |
| Sl No | Description | Qty | Unit | MS RAM KUMAR BANSAL CONTRACTOR L3 | M/s AMAN BUILDERS L1 | SHIVA ENTERPRIZES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Stripping and stacking iron/Asbestos sheets of a roof including ridging, flashing, eaves boards gutters and down pipes. | 413.87 | sqm | 30 ₹12,416.1 | 29 ₹12,002.23 Lowest | 30 ₹12,416.1 |
| 2.00 | Add for roof trusses of iron or wood, (rafters, purling etc.) in case of item Nos. 8.10 and 8.11. | 413.87 | sqm | 55 ₹22,762.85 | 53 ₹21,935.11 Lowest | 55 ₹22,762.85 |
| 3.00 | Dismantling asbestos cement, celotax or other hard board ceiling or partition walls including supporting timber. | 413.47 | sqm | 46 ₹19,019.62 | 44 ₹18,192.68 Lowest | 46 ₹19,019.62 |
| 4.00 | Stripping and stacking slate or tiles of a roof. | 193.05 | sqm | 46 ₹8,880.3 | 44 ₹8,494.2 Lowest | 46 ₹8,880.3 |
| 5.00 | Earth work excavation in ordinary soil, exclusive of compensation of earth:-
Earth work undressed with a combined lead upto 15 metres including breaking of clods. | 19.58 | cum | 115 ₹2,251.7 | 109 ₹2,134.22 Lowest | 114 ₹2,232.12 |
| 6.00 | Dismantling brick work tile, masonry or tile lining. - In cement | 292.96 | cum | 720 ₹2,10,931.2 | 682 ₹1,99,798.72 | 200 ₹58,592 Lowest |
| 7.00 | Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-inCharge. | 85.47 | Sqm | 115 ₹9,829.05 | 107 ₹9,145.29 Lowest | 112 ₹9,572.64 |
| 8.00 | Dismantling concrete Cement concrete plain 1:2:4 mix | 48.09 | Cum | 1,440 ₹69,249.6 | 1,366 ₹65,690.94 | 400 ₹19,236 Lowest |
| 9.00 | Dismantling concrete Cement concrete plain 1:4:8 or 1:5:10 | 90.07 | Cum | 720 ₹64,850.4 | 682 ₹61,427.74 | 200 ₹18,014 Lowest |
| 10.00 | Scrapping Of Bricks Recovered From Dismenteled brickwork | 56,248 | No. | 1.7 ₹95,621.6 | 1 ₹56,248 | 0.5 ₹28,124 Lowest |
Tender Value
₹9.8 Cr
EMD Value
₹19.6 L
Closing Date
21 Aug 2025, 9:00 amClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER FARIDKOT CANAL AND GW DIVISION FARIDKOT
Estimate for construction of Office Building of Faridkot Canal and Ground Water Division Faridkot
2025_WR_146689_1
Estimate for construction of Office Building of Faridkot Canal and Ground Water Division Faridkot
Open Tender
Civil Works - Buildings
Item Rate
365 days
FARIDKOT
Pre Qualification Details
2 documents required · 2 mandatory
₹5,000
Yes
₹19.6 L
Yes
FARIDKOT
29 Dec 2025
7 Aug 2025
21 Aug 2025
7 Aug 2025
21 Aug 2025
7 Aug 2025
13 Aug 2025
Amount
Stripping and stacking iron/Asbestos sheets of a roof including ridging, flashing, eaves boards gutters and down pipes.
Add for roof trusses of iron or wood, (rafters, purling etc.) in case of item Nos. 8.10 and 8.11.
Dismantling asbestos cement, celotax or other hard board ceiling or partition walls including supporting timber.
Stripping and stacking slate or tiles of a roof.
Earth work excavation in ordinary soil, exclusive of compensation of earth:- Earth work undressed with a combined lead upto 15 metres including breaking of clods.
Dismantling brick work tile, masonry or tile lining. - In cement
Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-inCharge.
Dismantling concrete Cement concrete plain 1:2:4 mix
Dismantling concrete Cement concrete plain 1:4:8 or 1:5:10
Scrapping Of Bricks Recovered From Dismenteled brickwork
Removing doors and windows together with the dismantling of walls -
Doors
Windows
Dismantling concrete or precast concrete. Reinforced cement concrete
Disposal of Malba ouside the premises loading/ unloading including all leads as desired by Engineer-in-charge.
DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points including necessary repairs to wall etc:-
Fan, light or call bell point
Wall socket, power plug point
Removal of existing Ceiling fans/ Exhaust fans
Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge.
EwC/owc
Cistren
Dismantling H.C.I Soil pipes including disposal as desired by the Engineer-in-Charge.
Hire Charges for Machinery for Office Record shifting both times
Tractor with trolley
Supply of Unskilled Labour for Office Record shifting both times
Supply of Unskilled Labour
Supply of skilled Labour for Office Record shifting both times
Supply of skilled Labour
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm.
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Total all floor
Extra rate for First Floor (c+d)
Extra rate for Second Floor (e+f)
Extra rate for Third Floor (g)
Cement concrete 1:3:6 with stone ballast or shingle 20mm guage using concrete mixing volumetric type & vibrator.
Total all floor (a+b)
Extra rate for Third Floor
Extra rate for Fourth Floor
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Centring and shuttering for Columns ( Square Or Rectangular or polygonal in plain)
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Extra rate for Fourth Floor
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Extra rate for Fourth Floor
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Total Qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
12.5 mm thick cement plaster 1:5
Total all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
20 mm thick cement plaster 1:5 in two coats
Area same as above item 15.10 for all Floors
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
12.5 mm thick cement plaster 1:4
Total all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
20 mm thick cement plaster 1:4
Area same as above item 15.9 all Floors
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Extra rate for Smooth Surface of Ceiling / RCC
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster
Providing and fixing in position gratings 150mm x 150mm for gully trap PVC grating
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 Sqm
Total Qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra labour for projected nosing of stair case of any shape and design
Providing and laying 2 inch wide Antiskid Safety-Walk Tape of 3M or equivalent make on staircase steps complete as per specification, Harmonised guidelines for PwD and as desired by Engineer-in-charge
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Total Qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size Size 600X600 mm.
Providing and Installation of Safety signage as per guideline for person with disability made of retro reflective sheeting as per colour specified and writing matter will be of same material in white fixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matter with braille also firmly fixed on wall with nylon fastener, brass screw and washer complete as per specification and as desired by engineer in charge.
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Supply & Fixing of door frames (Chowkhats) consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour) , 3 Nos 100mm but hinges 2mm thick, 6 Nos 1.2mm thick CRCA electroplated stiffner, 6 Nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire stasfication of Enginner-in- Charge.
Doors frame of size 80mm x 50mm with 37 mm wide single rebate for 35mm door shutter .
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1) (1999) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. 1 (size of door up to 700mm)
Providing & Fixing decorative high pressure laminated sheet 1mm (2 Star) thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Wire Mesh Windows shutter Section 40mm x 20mm with S.S wire mesh 32 guage flymesh with 144 holes per square inch
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in- charge . (Cost of Gasket /beading shall be paid as per respective item)
Providing & fixing fixed beeding 12mm x 12mm for fixed glass with ECO fixed gasket (EPDM)
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Providing Polyester Powder coating 60 to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing and Fixing in position collapsible steel shutters, with vertical channels 20mm x 10mm x 2mm and braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T iron 40mmx40mmx6mm with 38mm dia steel pulleys, complete with bolts, nuts, locking arrangements, stoppers, handles, etc. complete in all respects.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at mid specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in- charge.
Providing and fixing mineral fibre false ceiling tiles ( NRC 0.55 to 0.6) at all heights of size 595X595x16 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
Providing and fixing ceiling upto height 4 mtr consisting of 12.5mm thick gypsum board of any size G.I. Crradling hanged from the ceiling by means of G.I. Hanger complete as per drawings, specifications, and to the entire satisfaction of Engineer-in-charge.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Total Qty for All Floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Extra rate for Fourth Floor
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in charge.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer.
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of xcavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with a floating coat of neat cement and thick coat of Lime wash / P.O.P. on top of walls when dry for bearing of R.C.C. slabs & beams.
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm including preparation of surface
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. Including priming coat & preparation of surface
Supply & Fixing of door frames (Chowkhats) consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour) , 3 Nos 100mm but hinges 2mm thick, 6 Nos 1.2mm thick CRCA electroplated stiffner, 6 Nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire stasfication of Enginner-in- Charge.
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm)
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete.
Internal E.I. Services RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
Recessed Tv Telephone and networking socket and networking socket outlet ( used for HGW, PVC CONDUIT AND HDPE PIPE WIRING SYSTEM WITH MOUDLAR ACCESSORIES supply and erection of socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular Accessories) for having TV sockets Telephone sockets Rj 11 and Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material,cutting,and filling up of chases with finishing the surface) TV Wiring Networking socket point RJ45 (one module)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
Wiring light point with double control switches.
SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:- Wiring light point
Wiring 16/20Amp. power plug control point
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1 sq.mm (Un-sheathed)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 25sq.mm (3½ Core) Un-armoured (Loose)
Overall size 35sq.mm (3½ Core) Un-armoured (Loose)
Overall size 16sq.mm (4Core) Un-armoured (Loose)
Overall size 95sq.mm (3½ Core) Un-armoured (Loose)
Overall size 150sq.mm (3½ Core) Un-armoured (Loose)
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit pipe 32mm dia. (Flushed)
Heavy Gauge PVC Conduit pipe 40mm dia. (Flushed)
HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- PVC Flexible Pipe 25mm dia.
8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation: Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
COPPER EARTHING (Upto 8 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 20mm x 3mm Copper Tape (upto 8Metre in Length)
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- Additional Length 20mm x 3mm thick Copper Tape
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- Ceiling Rose (Flush Piano type)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Triple Pole 40amp. (10kA, Curve-C)
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
MCB Four Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- RCBO Four Pole 63amp., Sensitivity 30mA
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- SP&N Double Door Distribution Board 12 way each
TP&N Horizontal Double Door Distribution Board 4 way each
TP&N Horizontal Double Door Distribution Board 6 way each
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp)
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- Cable End Box for SPN 12 Way
Cable End Box for TPN 4 Way
Cable End Box for TPN 6 Way
Cable End Box for TPN Vertical 4/8/12Way
ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- On Load Change Over Switch Four Pole 160amp., 415volts
LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): LT PANELS: Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.
The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.
Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.
LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 10Nos. outgoing MCCB's 40amp. to 160amp. according to the requirement at site (Approx. size 2025 x 1800 x 400mm) (FOR EI & POWER LOAD) (Main Panel Incomer:- MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting =1 no. Outgoings:- MCCB 100/63Amp. Adjustable Thermal and Fixed Magnetic Protection, FP, 25KA=9 no. & On Load Change Over FP 250A = 1 no. )
MCCB's (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- Cable Tray Size 150mm x 50mm x 50mm (2mm thick)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 120/ 103.5mm (Outer/ Inner dia.)
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Aluminium thimble cable Core size 10 -16sq.mm
Aluminium thimble cable Core size 25 -35sq.mm
Aluminium thimble cable Core size 50sq.mm
Aluminium thimble cable Core size 70sq.mm
Aluminium thimble cable Core size 95sq.mm
Aluminium thimble cable Core size 150sq.mm
Supply and erection of LED batten 20watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary
Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and Erection of LED Bulk Head 9/10 Watt Surface mounted Pressure Die Cast Aluminium body (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of Recessed mounted 18watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 12watt LED Downlighter(including LED driver) with Pressure Die Cast with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of Recessed mounted 36watt LED 2x2 panel (including constant LED driver) with CRCA sheet having with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers and hanging GI wire with top roof complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary.
Supply and erection of ventilation fan 200mm 8 Inch including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Heavy duty Exhaust Fans 300mm 900RPM with aluminium louver shutter Canon of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of Ceiling Fans 1200 mm Sweep (48") 3-Star having two ball bearing including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site.
Supply and erection of Wall fan 400mm Swing 16 Inch high speed including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply, installation, testing & commissioning of Microwave based Occupancy sensor having high performance, non regulating programmable type, suitable for connected load up to 8.5 amp. For mounting height up to 2.5 mtr. and for 8*8 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, installation, testing & commissioning of Passice Infrared (PIR) technology based Occupancy sensor having high performance, non regulating , suitable for connected load up to 5.2 amp. For mounting height up to 2.5 mtr 3 X 3 m coverage area complete as required.complete in all respects as approved and desired by the Engineer-in-charge of the work.
Cost of 2 no's 13 Passenger (G+2) Lift's of any Reputed make Type and Capacity : Approximately 884 Kg( Deep) , 13 Passengers Lift without Machine Room Speed: 1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 12 Meter (Ground to Second Floor) Serving: 3 Floors 3 Stops 3 Openings 3 Levels (All on the same side) Hoist way : 2050mm (Wide) x 2500mm (Deep) Clear dimensions Headroom Height (HR): 5000mm beyond finished floor level of last landing Pit Depth : 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter & Maximum 2.20 square meter Car Enclosure : Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proof Car Entrance: Center Opening Automatic Doors with vision panel (Minimum 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 800/900mm (wide) x 2000mm (high)
Other Features : 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock
15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close. 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28.The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impaiments. 29. The Floor of the lift car should be slip resistant and have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling 30. The Provision of a mirror on the wall of the lift car opposite the lift door is a postive aid to navigation for wheelchair users, Its allows the wheelcahir user to see if anyone is behind them and also to see the Floor indicatior panel. The mirror should not extend below 900mm from the lift door to avoid confusing people with impaired sight. 31.The emergency communication system should be coupled with and induction loop system installed all around the lift. Telephone units. where provided, should have an inbulit inductive coupler to aiist person using hearing aids. 13 passenger lift to be provided, which allows easy maneuverability of wheelchair user. Final Product complete in all respects to the entire satisfaction of Engineer-in-charge.
Cost of LAN Networking System Supply, installation, testing and commissioning of Layer 2 Switches: 24x 10/100/1000BASE-T Interface (inbuilt 6kV surge Protection, 4 x 10G SFP+ Uplink, switching capacity 128 Gbps, packet forwarding rates 95.24 Mpps, MAC Address Table 16K, RAM/DRAM:- 256MB or higher and Flash/SSD : 64 MB or higher, Support IPv4 & IPv6: Cable diagnostics, 802.1D, 802.1w, 802.1s, 802.1p, 802.1X, LBD, IGMP/MLD Snooping, LLDP/LLDP-MED, Jumbo Frame Up to 12,000 bytes, Web-based GUI & Full CLI, Operating Temp 0 to 50 °C, Storage Temperature -20 to 70°C, Certifiate: CE, FCC, UL, LBD, MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017), OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent). Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing and Commissioning of 8 10/100/1000BASE-T PoE and 2 100/1000 Mbps SFP ports loaded with one RJ45 transciver, one SFP 1G Singlemode transciver, IEEE 802.3af/at compliance (for PoE ports),130W,SSL, Management VLAN, NTP,RADIUS, TACACS+ , RFC 2464, RFC 4213, RFC 4884, RFC 4861, Auto configuration , Static IPv6 default gateway , IPv6 duplicate address detection Dual configuration, 16k Mac Address, Dual image, Operating temperature: 0°C to 45°C.Should be provided with utility for Centralized and batch configurations ,IP configuration , IP renew , Device factory reset , Device reboot , Device locating , Web GUI access , Firmware upgrade , CE, FCC, C-Tick, 5 Years warranty. OEM Should be ISO 9001,14001 & ISO 45001 Certified. , Cloud Management Support to be Bundled along with Switch. All Switches and its Components from Same OEM. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation, Testing and Commissioning of Dual-Band AP (Access Point) Wireless, Superior throughput with Dual-band transfer speeds packed with all the advances of Wave 2 ac Access Point. Channel Bonding, MU-MIMO,2.4 GHz: IEEE 802.11b/g/n,5 GHz: IEEE 802.11a/n/ac,802.11ac @ 80 MHz: 866, 780, 650, 585, 520, 390, 260, 195, 130, 65 Mbps, 802.11n @ 40 MHz: 300, 270, 240, 180, 120, 90, 60, 30 Mbps, 802.11a/g @ 20 MHz: 54, 48, 36, 24, 18, 12, 9, 6 Mbps, 802.11b @ 20 MHz: 11, 5.5, 2, 1Mbps,2x2:2 MU-MIMO, WPA2-TKIP/AES Personal, WPA-TKIP/AES Personal, WPA2-Enterprise (802.1x/EAP), WPA Enterprise (802.1x/EAP), Open, 4 x Internal Omni-Directional Antennas, 3 x 10/100/1000 Base-T with One PoE In (802.3af/at) port, Three years limited liability manufacturer’s warranty from DATE OF ACTIVATION of the device Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of wireless controller for managing acess point with hardware or cloud controller. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, installation, testing and commissioning of 24 port, modular design, loaded Patch Panel 4X6 TYPE, populates up to 24 UTP keystone-type jacks in 1U,Enhanced with cable strain relief with retention tray, combination of high grade plastic and CRS metal,Standard : Conforms to IEC-60603-7 (603-7) for keystone-type, snap-on apertures, RoHS complied, compatiable with Cat 5, Cat 6 and Cat 6A UTP Keystone Jack,Compatible with RJ standard plugs (RJ11, RJ12, RJ45), PCB and with tool Less connection of installation cables AWG 24 – 22 (0.5 mm – 0.65 mm) and flexible cables AWG 26/7 – AWG 22/7.,Termination should feature nil crossover in acc. with EIA/TIA 568-A/B, gold-plated 50micron bronze contacts for >750 mating cycles, >200 insertion cycle,Connector should be 50micron gold-plated and supplied with stain relief cap on back side of Jack,Housing material: Polycarbonate (UL-94-V0) Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing and commissioning of 8 port, Category 6, punchdown patch panels shall terminate 4-pair, 22 – 26 AWG, 100 ohm cat 6 cable Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Category 6, 1 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Category 6, 2 Meter UTP patch cords shall be constructed of 24 AWG,Number of conductors : 8 ,Cable jacket characteristics: cable, metal-free,Cable overall diameter: 6.0±0.2 mm, Tube / Wire type: stranded conductor, Plug: Feature cable retension, with enhanced pull strength.,Cat 6 patch cord plug to have round cable holder and strain relief snagless boot to avoid bending,Jacket: PVC / LSZH with different color and Size options, Plug should have high repeatability cross talk performance with 50micron gold plating connector plug, Patch cord connector should be 50 micron gold plating plug, Standardization: Compliant with Cat.6, Class E requirements: ISO/IEC 11801 2nd Edition Compliant with Cat.6 component standards IEC 60603-7-4 and 60603-7-5 . Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, installation, testing & Commissioning of Wall Mounted Rack network Rack - 15U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U (4no's) MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of Floor Standing Rack network Rack - 42U / 600w / 800d, with Heavy Duty Extruded Aluminium Frame for rigidity. Top cover with FHU provision. Top & Bottom cover with cable entry gland plates. Two pairs of 19” mounting angles with ‘U’ marking. Depth support channels - 3 pairs. With a Overall Weight Carrying Capicity of 500Kgs. Side Panels - 42U/800d Front MS Door perforated honeycomb 42U/600w Rear MS Door (Fully Perforated - Mesh) 42U/600w Fan 90CFM 230V AC, 4” dia Castors with Brake (set of 4) Cable manager 1U MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20) Complete in all respect to the entire satisfaction of the engineer-in-charge .
Copper conductor cables for special electrical services Supply and erection of CAT 6 with 23 AWG solid bare copper conductor special grade PE insulation with star separator, 4 pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed Class-E. 250 MHz of bandwidth , supporting data transfer speeds of upto 10 Gbps ( 10 GBASE-T) For Distance up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-c.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer--in-charge
Supply, Installation, Testing & Commissioning of firewall with 300 users include 3 year subcription with following specification • No built-in mechanical moving parts. Throughput threat defense Software:-1.5-2.1 Gbps or Better. IPS Throughput:--1.0-1.5Gbps or Better. Interfaces:- 8XRJ 45,4XSFP or Better. Maximum Concurrent session with AVC: - 200K or Better. Maximum new connections per second with AVC:-14K-15K or Better. Transport Layer Security:- 700Mbps or Better. Maximum VPN Peers:-150 or Better. URL Filtering number of:- More than 80 or Better. URL Filtering number of URL's Categorized:- More than 280 Million or Better. Stateful Inspection firewall throuhput1:-4.5 Gbps or Better. Concurrent Firewall Connections:-200000 or Better. In Built Fan., Web Protection., User Web policy Creation., Email Protection. ,Group Policy Creation. Data Loss Prevention., Advance threat protection. , Optional Integration with GSM Gateway for Sim based authentication., Certification:-CE,FCC CLASS A,CB & UL, VCCI, RCM, KC,CCC,BIS. The Firewall must provide NAT functionality, including dynamic and static NAT translations.,Firewall should be able to support Port Forwarding.Should have option to configure traffic shaping / QOS,Compatible to Centralized Management,The firewall must support Active-Active as well as Active-Passive redundancy.Actibve/Active as well as Active/Passive HA Clustering can be achieved,The cluster should support simple and minimal downtime during upgrade,Should have option to create ALIASES to identify group of Hosts or networks with one Unique Name,Should have option to create Customized Aliases based on User/Group , Host IP/IP Range & Interface, complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation, Testing and commissioning of 1 KVA Online UPS 36VDC with In- Built 3 No. Batteries Pure Sine wave with following features:- OVCD, Wide input range, Programmable output range 208V/220V/230V/240V, 12V x 7Ah x 3 No. SMF batteries in-built, Output Power Factor 0.9, 0ms Transfer time from Inverter Mode to Battery Mode ,Charger Current 1.5 Amp, Cooling Fan, True Online Double Conversion, Inbuilt Over-voltage Cut-off Device, Inbuilt Over Temperature Protection, Surge Protection, Better Overload Protection upto 105% Constant, Higher Efficiency up-to 92% in ECO Mode, 2 year onsite warranty on UPS with 30+ minutes Back up time on switches load complete in all respects as approved and desired by the Engineer-in-charge at site
Cost of EPABX System Supply, installation, testing & Commissioning of Core IP-EPABX Configured for 01 no. SMPS Power Supply, 04 Trunk Ports, 08 SIP Trunks02 Normal Extension 00 GSM Trunk Ports, 32 IP Phone Extension and Expendable up-to 64 IP Extensions. With following features:- Type of Switching IP at Core Processor Speed Made and make in India VOIP Protocols-SIP v2, SIP over TCP, Symmetric RTP, RTCP, 100rel/PRACK Network Protocol IPv6, IPv4, TCP, UDP, SNTP, STUN, ARP, ICMP, PPP, DNS CO Trunk-Type Expansion Card for CO/FCO Interface Signalling Loop Start Loop Limit 1200Ω Off Hook AC Impedance 600/900/Complex Pulse Dialling 10/20PPS DTMF Dialling and Reception ITU-T Q.23 & Q.24 Return Loss >18dB Longitudinal Balance >50dB Transmission Level Adjust Tx Gain: -15dB to +10 dB, Rx Gain: -15dB to +10dB CLI Reception DTMF, FSK ITU-T V.23 and FSK Bell core 202 Call Maturity Delay and Polarity Reversal Protection Over Voltage and Over Current Secondary RS232c (COM) Ports - 1 No., USB Ports -1 No. , Group Conference (3-Party) - 15 No., Auto-Attendant, Voice Help, Voice Tones Voice Messages (16 seconds each) Ethernet Ports (Gigabit) - 01 No. Support Single Line Analog Telephones GSM/3G/4G NetworkTwo wire TrunkIP UsersSip Trunks complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, installation, testing and commissioning of Layer 2 Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Switch, 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent). complete as required.Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply & erection of IP Telephone, PoE, SIP with Display, Redial, CLIP, 2 Way Speaker, Mute Compatible with EPABX System. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply & erection of Executive IP Telephone, PoE, SIP with Large Backlit with 2 Giga LAN Ports 1000 Mbps Speed, 16 Direct dialling keys Backlit Display, Direct Dialling Keys, HD sound quality, Duplex Speaker Phone, Context sensitive keys POE Support, Adaptor Support, 3.1 inches Screen, VoIP Protocol including all features listed in Product Boucher complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation and Commissioning of IP Operator Console with 48 One Touch Duplex Speaker with DSS and should have following inbuilt feature The key phone should have facility of dual color LED indication. The key phone should have 2x16 character display. The key phone should have at least 48 programmable keys. The key phone should have 10 fix functions keys. The key phone should have ring LED indicator The key phone should have full hands free operation, The key phone should have adjustable height The key phone should have facility to connect additional console for additional programmable keys. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply & erection of Plan System(1+1) without Display with all accessories including:- 1. Boss Set - 1 No. 2. Secretary Set - 1 No. 3. AC/DC Adaptor - 1 No. 4. Connecting Leads- 2 No. 5. Rossttee Box - 2 No. 6. Manual - 1 No. Complete in all respect to the entire satisfaction of the engineer-in-charge
Cost of Fire Alarm and Evacuation System PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 2Core
Supply, Erection, Testing and Commisioning of of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm 2 Loop Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. Designed to meet UL864, 10th Edition. Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing and Commissioning of Digital Audio Amplifier. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of 100 W at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. The Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power) Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Erection, Testing & commissioning of Inbuilt automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH with Emergency evacuation Control Panel & Digital Voice command system with Battery Dress Panel. Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing and Commissioning of Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. Products not having this feature must provide dedicated CPU for DVC. The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. The panel shall be capable of self programming without any dependency on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for programming the panel with all necessary licence. Panel shall have Modbus/ Bacnet over IP protocol for future integration with BMS. However, for the present arrangement the FA system will be standalone with 24x7 monitoring. The panel shall be capable of remote accessibility on a mobile app through cloud platform/solution. Designed to meet UL864, 10th Edition. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing & Commissioning of OEM of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include Response Indicator, the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Designed to meet UL268, 7th Edition Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of Response Indicator wall/ceiling mounted type construction plastic/ aluminium with blinking red color indication blinking facility with necessary mounting and fixing arrangement accessories, etc., complete. Complete in all respect to the entire satisfaction of the engineer-in-charge
Supply, Installation, Testing & Commissioning of OEM Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches UL Listed. Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of OEM Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of OEM Addressable Manual Call Point (Pull down Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of OEM Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of OEM Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply, Installation, Testing & Commissioning of Fire Fighting Telephone Jack UL Listed Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of Addressable Telephone Control Module. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL Listed. Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of Telephone Handset for 2 way UL Listed Communication System Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Erection, Testing & commissioning of OEM Ceiling mount type 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms, UL Listed. with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Erection, Testing & commissioning of OEM 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Wall Mount Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms, UL Listed. with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation, Testing & Commissioning of single/ double sided Glow Type EXIT SIGNAGE for 20 mtrs. view: SL20,NM,IP42,60lm,3Hr. EN compliant, 3 hours battery back-up, built in Ni-cd battery with miimum size 250mmx200mm. Acrylic sheet on side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply and drawing of Armoured Fire Survival 2 C X 1.5 Sq mm multi stranded twisted unshielded FRLS Copper cable on surface with clips or in existing pipe Complete in all respect to the entire satisfaction of the engineer-in-charge .
Supply & Laying of Cable & Accessories::Speaker Cable 1.5 sqmm in PVC Conduit should be laid in existing PVC/HDPE pipe complete in all respect as desired by the engineer in charge.
Supply, Installation, Testing & Commissioning of BIS Certified Self Contained Rechargeable Wall Mounted Emergency Egress Routes Lighting , Maintained Type , ingress protection IP 20 , Housing CRCA Sheet 22 SWG fabricated, Message printed on 2mm thick milky acrylic, Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Viewing distance 24M, Ambient temperature -25°C to +60°C, , INDICATIONS Mains ON: Red LED ON, CIRCUIT POWER - Overall: 5W - On mains (LED): 3W - On battery (LED): 3W, PROTECTION - Protection Protection class: Class I, Low battery cut-off: 2.4±0.1V ,Over charge cut-off: 4.2±0.1V , BATTERY - Charging method: Constant Voltage - Back-up duration: 120 minutes - Recharging period: 10-18 hours - Battery type: 3.7V lithium ion - Battery capacity: 2200mAH, Conforms to IS 10322, BIS Certified Part 5 / Sec - 8 Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of BIS Certified Self Contained Rechargeable Surface Mounted Emergency Egress Routes Lighting , Maintained Type , ingress protection IP 20 , Housing CRCA Sheet 22 SWG fabricated, Message printed on 2mm thick milky acrylic, Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Viewing distance 24M, Ambient temperature -25°C to +60°C, , INDICATIONS Mains ON: Red LED ON, CIRCUIT POWER - Overall: 5W - On mains (LED): 3W - On battery (LED): 3W, PROTECTION - Protection Protection class: Class I, Low battery cut-off: 2.4±0.1V ,Over charge cut-off: 4.2±0.1V , BATTERY - Charging method: Constant Voltage - Back-up duration: 120 minutes - Recharging period: 10-18 hours - Battery type: 3.7V lithium ion - Battery capacity: 2200mAH, Conforms to IS 10322, BIS Certified Part 5 / Sec - 8 Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply, Installation, Testing & Commissioning of BIS Certified Self Contained Rechargeable Emergency,Non Maintained Type , ingress protection IP 65 , Housing Molded ABS, White in colour,Diffuser Molded Polystyrene, Opal reeded finish Supply voltage 230VAC, Supply current 50mA max, Number of LEDs - 20 (0.2W), Ambient temperature -25°C to +60°C,LED Make Edison, Luminous flux >180Lm.Automatic, Relay, Ra > 40. PTI < 600V, INDICATIONS Mains ON: Red LED ON., CIRCUIT POWER Overall: 5W. Protection class: Class I Low battery cut-off: 2.4±0.1V Over charge cut-off: 4.2±0.1V PROTECTION Charging method: Constant Voltage. Back-up duration: 180 minutes, Recharging period: 10-18 hours Battery type: 3.7V lithium ion,Battery capacity: 2200mAH BATTERY Mounting type | Surface mounting Weight | 2 Kg. approx. Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply & Erection of SUPER glow Series Self Maintain Photoluminescent SWGS Plan/Signages in 1 mm thick Rigid Sheet SUPERGLOW RIGID SHEET with Strong Self Adhesive, Life: 10-15 Years, Weather Proof. The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). Self Extinguishing. The Sign does not contain any radioactive substances. In toxic terms the product is considered as safe. Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance. As Per PSPA Class- A / DIN 67510 Part 2 / 60 Minutes / > 700 mcdl with High photoluminescent luminous intensity. Certified By Government Of India Lab For A Glow Period >24Hrs. DRDO & ARAI Certified for all required QC tests to confirm as per the IS 9457-2005, IS 12349 (To be approved by EIC). The colour should be RED/GREEN/BLUE/YELLOW with graphics symbol in white. Complete in all respect to the entire satisfaction of the engineer-in-charge. S/E of FLOOR INDICATOR (Minimum size 250mm x 200mm)
Supply & Erection of SUPER glow Series Self Maintain Photoluminescent SWGS Plan/Signages in 1 mm thick Rigid Sheet SUPERGLOW RIGID SHEET with Strong Self Adhesive, Life: 10-15 Years, Weather Proof. The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). Self Extinguishing. The Sign does not contain any radioactive substances. In toxic terms the product is considered as safe. Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance. As Per PSPA Class- A / DIN 67510 Part 2 / 60 Minutes / > 700 mcdl with High photoluminescent luminous intensity. Certified By Government Of India Lab For A Glow Period >24Hrs. DRDO & ARAI Certified for all required QC tests to confirm as per the IS 9457-2005, IS 12349 (To be approved by EIC). The colour should be RED/GREEN/BLUE/YELLOW with graphics symbol in white. Complete in all respect to the entire satisfaction of the engineer-in-charge. S/E of IN CASE OF FIRE DO NOT USE LIFT USE STAIRS (Minimum size 200mm x 200mm)
Supply & Erection of SUPER glow Series Self Maintain Photoluminescent SWGS Plan/Signages in 1 mm thick Rigid Sheet SUPERGLOW RIGID SHEET with Strong Self Adhesive, Life: 10-15 Years, Weather Proof. The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). Self Extinguishing. The Sign does not contain any radioactive substances. In toxic terms the product is considered as safe. Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance. As Per PSPA Class- A / DIN 67510 Part 2 / 60 Minutes / > 700 mcdl with High photoluminescent luminous intensity. Certified By Government Of India Lab For A Glow Period >24Hrs. DRDO & ARAI Certified for all required QC tests to confirm as per the IS 9457-2005, IS 12349 (To be approved by EIC). The colour should be RED/GREEN/BLUE/YELLOW with graphics symbol in white. Complete in all respect to the entire satisfaction of the engineer-in-charge. S/E of MAN RUNNING STAIRCASE DOWN (Minimum size 250mm x 200mm)
Supply & Erection of SUPER glow Series Self Maintain Photoluminescent SWGS Plan/Signages in 1 mm thick Rigid Sheet SUPERGLOW RIGID SHEET with Strong Self Adhesive, Life: 10-15 Years, Weather Proof. The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). Self Extinguishing. The Sign does not contain any radioactive substances. In toxic terms the product is considered as safe. Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance. As Per PSPA Class- A / DIN 67510 Part 2 / 60 Minutes / > 700 mcdl with High photoluminescent luminous intensity. Certified By Government Of India Lab For A Glow Period >24Hrs. DRDO & ARAI Certified for all required QC tests to confirm as per the IS 9457-2005, IS 12349 (To be approved by EIC). The colour should be RED/GREEN/BLUE/YELLOW with graphics symbol in white. Complete in all respect to the entire satisfaction of the engineer-in-charge. S/E of FIRE ACTION BOARD (Minimum size 450mm x 600mm)
Supply & Erection of SUPER glow Series Self Maintain Photoluminescent SWGS Plan/Signages in 1 mm thick Rigid Sheet SUPERGLOW RIGID SHEET with Strong Self Adhesive, Life: 10-15 Years, Weather Proof. The sign can easily be cleansed with a dry cloth or with a cloth humidified with water (without detergents). Self Extinguishing. The Sign does not contain any radioactive substances. In toxic terms the product is considered as safe. Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance. As Per PSPA Class- A / DIN 67510 Part 2 / 60 Minutes / > 700 mcdl with High photoluminescent luminous intensity. Certified By Government Of India Lab For A Glow Period >24Hrs. DRDO & ARAI Certified for all required QC tests to confirm as per the IS 9457-2005, IS 12349 (To be approved by EIC). The colour should be RED/GREEN/BLUE/YELLOW with graphics symbol in white. Complete in all respect to the entire satisfaction of the engineer-in-charge. S/E of EMERGENCY EVACUATION PLAN (Minimum on A2 (420mm x 594mm))
Supply, Installation, Testing & Commissioning of Wall Mounted Rack network Rack - 9U 500d, with Heavy Duty Extruded Aluminium Frame for rigidity. Fan 90CFM 230V AC, Cable manager 1U MS with Loops Shelf, PDU 6 Sockets 5Amps with MCB Mounting Hardware (Pkt. Of 20).complete in all respects as approved and desired by the Engineer in-charge at site.
Supply & erection of 20W Wall Mount Speaker with Frequency Response 200Hz - 15kHz, with Line Matching transformer 100V, SPL@1M - 82dB, Peak SPL 84dB. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply Installation Testing and Commissioning of 1080p DLP Projector with following Specifications: Above 3000ANSI Lumens high Brightness, 1 billon colours upto 200 inch screen sizes, 16 ms low input lag, 10watt chamber speaker dual HDMI cable 100 inch large projector screen 16/9 hanging projection screen. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply & Laying of Cable & Accessories :: Speaker Cable 1.5 sqmm in PVC Conduit should be laid in existing PVC/HDPE pipe Complete in all respect to the entire satisfaction of the engineer-in-charge.
Supply & Laying of Amplifier mic XLR cable 3 pin complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, Installation, Testing & Commissioning of Power Amplifier 100 Volt amplifer,Rated power 50W, 70V, 100V, Frequency Response 60-15KHz,S/N Ratio >= 70dB,THD <0.1% at 1KHz,4-16 ohm speaker outputs,Isolated transformer, Balanced XLR type line input and unbalanced phone jack line input, Balanced XLR type line output feeds to another power amplifer complete in all respect as desired by the Engineer-in- charge at site.
Supply, Installation, Testing & Commissioning of OEM Controller unit and power supply unit & 45 Watt In Built PA Amplifier, USB for Recording and SD Card Slot for Play back with digital acoustic feedback suppression, Control up to 50 discussion unit. Three band equalizer for better sound performance, Microphone input, Cinch connector for connecting external PA system complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, Installation, Testing & Commissioning of OEM Chairman unit with light ring built in loudspeaker, priority button for muting delegate, priority button for Chairman, press to talk button, Automatic Loudspeaker when Mike is on, Two 3.5 mm stereo Jack, Built-in volume control for Head phone. Microphone on-off button. Microphone on LED indicator, 8 pin connection termination socket with 2.7 meter cable for loop connector to other included complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, Installation, Testing & Commissioning of Delegate unit with light ring built in loudspeaker, press to talk button, Automatic Loudspeaker when Mike is on, Two 3.5 mm stereo Jack, Built-in volume control for Head phone. Microphone on-off button. Microphone on LED indicator, 8 pin connection termination socket with 2.7 meter cable for loop connector to other included complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, Installation, Testing & Commissioning of 10 Meter Long Audio cable for connecting controller unit with mic complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, Installation, Testing & Commissioning of 24Floor mount 19" Rack with glass door,lock& key facility 450mm-550mm depth with CPD, Cable Manager & Fan complete in all respects as approved and desired by the Engineer-in-charge of the work.
Supply, Installation. Testing & Commissioning of Sound Bar with Audio Cable 100 Watts complete in all respects as approved and desired by the Engineer-in-charge of the work.
Cost of Security Lighting PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 3Core
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
LAYING OF UNDER GROUND CABLES, DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS: Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 140mm x 140mm x 95mm with hinged water tight cover with locking arrangement
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Aluminium thimble cable Core size 10 - 16sq.mm
Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Cost of On Grid Solar Power Generating System of 20kw Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 20KWp including required quantities of SPV modules (High power density Monocrystalline based single module iof capacity+400W) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Chemical copper bonded rods (i.e. 1 Nos. GI Structure, 2Nos. for String Inverter, AC & DC Distribution System)Provsion of Lighting arrester and 2 Nos. G.I. chemical earthing with copper bonded rods. Hot Dip Galvanized MS Mounting Structure be Designed to with stand the Speed for the Wind Zone of the Location(Rated Wind Speed 150-170Kph) Complete with transportaion, fabrication, labour & Civil Work. Features:- 1. Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 1&2 IS/ IEC 61701 & IS/IEC 14286 & IEC 61215, BIS Certificates & MNRE, GOI latest specifications / Standards. 2. Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1,IEC / EN 62102-2 , EN 61000-6-2, EN61000-6-3, IEC61683, EN 50530 , IEC 60068-2-1,2,14,30,EN 60529, IES 60947 Part 1,2,3 IS 60947 Part 1&2 , IES 60227/IS 694,IES 60502/IS 1554 BIS Certificates & MNRE, GOI latest specifications / Standards. 3. Structure : 25 Years Service Life with AMC & Certified under IS 2062:2011 4. Complete Plant Insurance for the period of 5 Years (Excluding Theft of the material) 5. Annual Maintenance Contarct for the period of 5 Years Conditions:- 1. The Plant will be installed as per MNRE and GOI guidelines specifications.(Detail of Material as per Annxeure -1 Attached) 2. The Work will got done from approved MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) Contractors.PWD enlisted contractor subject to condition that PWD Enlisted contractor will get work done from MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) approved Conractors. The Rates are inclusive of Bi-directional meter testing charges, PSPCL Connection Charges, Unidirectional meter cost and all type of taxes including GST Final Product complete in all respects to the entire satisfaction of Engineer-in-charge.
Cost of Silent DG Silent's 82.5KVA with CPCB-4+ norms PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (50/0.25mm), 2Core
COPPER EARTHING (Upto 14 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- Additional Length 25mm x 3mm thick Copper Tape
Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 82.5KVA/66KW without AMF Panel, Three Phase, 415Volts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.
ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.
MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-42 degree of protection & front operated, composite meter for digital display. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B
110mm o/d single socket SWR UPVC pipe lines laid complete
90mm o/d single socket SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm o/d pipes
Elbow 90 Degree (All side socketed)
Vent Cowls
Coupler
Single Tee With Door
For 75mm o/d pipes
Elbow 90 degree (all side socket)
Vent Cowls
Coupler
Single Tee With Door
With 75mm i/d outlet deep seal at Ground Floor
With 75mm i/d outlet shallow seal at First Floor
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
M.S. Holder bats clamps for 100mm i/d as per table-1
M.S. Holder bats clamps for 75mm i/d as per table-1
Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
uPVC Pipe 6 Kgf/cm2 50mm i/d as per table-1
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 16mm o/d
SDR 11 CPVC pipes & fittings 20mm o/d
CPVC SDR 11 Pipe & fitting 25mm o/d
CPVC SDR 11 Pipe & fitting 32mm o/d
CPVC SDR 11 Pipe & fitting 50mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick Detail as per Table-2
Through wall 22.86 cm thick Detail as per Table-2
Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect.
20mm i/d Cpvc Union
25mm i/d Cpvc Union
32mm i/d Cpvc Union
50mm i/d Cpvc Union
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
25mm i/d Brass Ball valves
50mm i/d Brass Ball valves
Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge) complete in all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Size 49 cm dia (above counter round)
Size 550 mm x 400 mm x 815mm
Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P. brass towel Rails size 15mm dia 610mm long
C.P brass towel ring
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect.
C.P. brass Bib cock long nose/ long body without flange
C.P Brass bib cock foam flow without flange
Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect (instead of Pillar tap in Lavatory Suites).
Providing and fixing in position C.P. brass Foot operated auto closing valve for Basin taps and spouts (Table mounted)with two 900x1200mm long braided hoses with 15mm nuts of approved make (to the approval of Engineer-in-charge)
Providing and fixing in position C.P. Brass Foot operated auto closing valve with pressmatic Basin taps only with plug (Table mounted)with two 900x1200mm long braided hoses with 15mm nuts of approved make (to the approval of Engineer-in-charge)
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm Angle valve without flange
C.P.brass 15mm Concealed stop cock with flange
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
C.P. brass toilet roll holder with flap
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
Brass Ball Cock with rod and Plastic Ball 50mm i/d
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
G.I. tank nipple 25mm i/d
G.I. tank nipple 50mm i/d
Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.
35mm dia 900mm (36”) long
35mm dia 1200mm (48”) long
Foldable U Type 762mm long
Providing and fixing Stainless steel health faucet complete in all respect.35 mm dia 900 mm (36") long
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Fine sand) for new flooring complete .
Total All Floor
Extra rate for First Floor
Extra rate for Second Floor
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm).
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Total All Floor
Extra Rate for First Floor
Extra Rate for Second Floor
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
Total All Floor
Extra Rate for First Floor
Extra Rate for Second Floor
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Full Steel Body 150/150 ltr without Stablizer Detail as per Table-3
Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-
Automatic Voltage Stablizer 2 KVA ( For WaterCoolers)
Automatic Voltage Stablizer 4 KVA ( For AC's)
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Inverter Type ( having ISEER Rating 5.13 and Cooling Capacity 5230 W Minimum) witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects
Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Inverter Type( having ISEER Rating 5.05 and Cooling Capacity 6000 W Minimum) with MCB arrangement for installing OD units on terrace/ Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects
Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. For 1.5 & 2 tonne A,C.
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. - uPVC Pipe 10 Kgf/cm2 - 25mm i/d - For 1.5 & 2 tonne A,C.
Drilling of 500mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil andtransportation of rig to the site. complete in all respect.
Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL.
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. Make :- Jindal / Tata or Equivalent Make
150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest with SS socket to connect Strainer to Strainer Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
150mm Steel Strainer (slot size 0.75mm) 5.00 mm thickness
Supplying, fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest,ISI Marked Duly Welded with suitable grade S,S welding electrode to lower the strainer into the Tubewell bore complete in all respect.
150MM internal diameter
Supply & fixing of ball plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects. 150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Supplying and fixing well cap having threads to fix on housing pipe complete in all respect 150mm id.
Supplying and fixing mild steel clamps of 150mm x 12mm made out of MS Flat (1.52 mtr long suitable to fit the housing pipe including the cost of Nut or bolt of suitable size complete in all respects
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
150 mm internal diameterweight)
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample received from the bore
Supplying at quarry site of gravel of 1/6" to 1/8" sizes including pouring and packing in the annual space between the pipe assembly & the bore. The gravel should be free from dust, dirt, or the vegetable manner as per IS 4097-1967 with latest amendments (to be paid as per actual length of pipe) Note: The rates including loading & unloading charges. Carriage from quarry site will be paid extra as per actual
Development and stabilizing of the Tubewell with Air Compressor required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Supplying and fixing mild steel centering guides made out of 32mm X 6mm thick M.S bar complete in all respect Note :- a) Strainer & M.S. Pipe should be properly jointed with sockets and duly welded to ensure maximum strength of joint. b) A steel strip of suitable size should be welded across the length of strainer to provide additional strength to the tubewell assembly.
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Urainium etc.)
Development and stabilizing of the Tubewell with Air Compressor and submersible pumping set of required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge.
Providing and Installing Testing & Commiissioning of 1 Nos Electrically driven submersible Pump set of 3.00 BHP capable of delivering 146 LPM against a head of 48 mtr.
Providing and Installing Electric Control panel board consisting of electrical appliances such as automatic star Delta Push Button or oil immersed starter, Main switch, VM, Ampere Meter, ELCB, shut capacitor. Single phase, preventer, indicating laps, Kit-Kat etc. complete ina all respets.
Providing and Fixing 50 mm G.I. Column Pipe (in 3mtr lengths each with flnages, screwed and welded on both sides) rubber gaskets, nuts and bolts
Providing and fixing Submersible cable 2.50sqmm IS694-1990 reaffirmed 2000 - Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 2.5sq.mm (50/0.25mm), 3Core
Providing, installing, testing and commissioning one no. electrically actuated diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 ltr. o f bleaching powder solution/ sodium hypo solution per hour under maximum delivery pressure up to 7kg cm2, and suction lift not less than 1.5m, as per DWSS standard specification
Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter
Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). R.C.C. Manhole cover - 560mm i/d RCC man hole cover with frame as per ISI
Foot Rest for Manhole. Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Earth work upto 1.5 m. Depth - All classes of soil except rocky
EXTERNAL IN THE GROUND : Providing and fixing hlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
CPVC SDR 11 pipe & fittings 50mm o/d
Providing, fixing and jointing ISI Marked Gun Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.
50mm i/d Gun Metal peet valve heavy pattern.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Size 0.6 m. x 0.6 m.
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
110 mm o/d pipes
160 mm o/d pipes
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard
Inside size 75x120 cm
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
Cement Concrete 1:2:4 with stone ballast or shingle mixing by mechanical means using concrete mixing volumetric type
Floating coat of 1:5mm thick neat cement laid in one operation to the topping
12.5 mm thick cement plaster 1:3
Cement rendering on plaster 1mm thick
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC Man hole cover with Frame 560mm i/d RCC man hole cover with frame as per ISI
Heavy duty
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
160mm o/d pipe of 6 Kgf. / sqcm
160mm o/d pipe of 6 Kgf. / sqcm
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
As per Detail attached
Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity
Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity
SITC of MS Pipe Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
100mm internal diameter
SITC of Butterfly valve Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.
100 mm i/d for Internal Hydrants
Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.
100mm i/d check valve
Providing and fixing S.S Pressure Gauge complete as required complete in all respect.
Dial diameter 100mm calibration 0-16 Kg
Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).
Four Way inlet connection
Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.
Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipes.
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.
600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel)
Providing & fixing Fire Hydrants with jointing including all carriages complete. (without Fire Hydrant surface box) Size 80mm complete in all respect.
C.I Fire Hydrants S.V. Type IS-909 for Internal Hydrants
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all respect
Supplying and Installation control valve C/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. complete in all respect.
100 mm control valve
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per IS
100mm i/d Sluice Valves flanged
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.
100mm internal diameter
100mm internal diameter
XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
Overall size 16sq.mm (3Core) Armoured (Underground)
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
5000 ltr Capacity
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
Brass Ball Cock with rod and Plastic Ball 32mm i/d
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
G.I. tank nipple 40mm i/d
EarthingwithG.I.wire/ rope inG.I.pipe partly recessed and partly on surface complete with 150 cm long 50 mm dia .G.I. earthpipe(Cutting thread sand 36 Nos. holes, 1cmdia. tomakeamesharound the GI Pipe) and with G.I. reducing socket including erectionof the same, 10.50 metre (34.44 feet) below ground levelwith20Kg. charcoal &saltmixture etc., upto 14 metre in length (including boring & refilling).
Earthingwith7/14S.W.G. (7/2.18mmdia.) G.I. rope in20mmdiaG.I. pipe with G.I. reducing socket 50mm x 20mm (upto 14Metre in length)
Jockey Pump Supply, installation, testing & Commissioning of Kirloskar make pump in back pull out design having 50mm suction, 32mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 7.5KW/10 HP, 2900 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow: 10.8 m^3/hr(180 lpm)
Diesel Engine Supply, installation, testing & Commissioning of pump model in back pull out design (end suction type) having 100mm suction, 80mm delivery, CI casing, bronze impeller and CS shaft with gland packed arrangement coupled on common baseplate 56 BHP, 1800 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50Hz AC supply confirming to through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 60m Flow : 137 m^3/hr(1620 Ipm)
Electric Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED DIESEL ENGINE DRIVEN PUMPSET in back pull design having 125mm suction, 100mm delivery, CI casing, bronze impeller, C-40 shaft with gland packed arrangement coupled on common MS fabricated baseframe vertical water cooled diesel engine complete with 12 V battery start arrangement, air cleaner, exhaust silencer(without piping), fuel filter, developing 50 BHP at 1800 RPM. Engine with twin belt driven radiator and complete with engine starting panel, Battery & AVM pods. Total head : 60m Flow :137 m^3/hr(1620 Ipm)
Pressure Pump Supply, installation, testing & Commissioning of MAKE FACTORY ASSEMBLED Pressure Pump having Discharge 450 LMP and maintain required pressure in Down Comer as required by engg. in charge cpmplete in all respect Total head : 60m Flow : 450 Ipm
Hydrant Panel Providing & fixing of Hydrant Electrical Panel of cubical type floor mounted power cum control of Jockey Pump 1 No. & Electrical Pump 2 No. having MCCB 400 Amp 3 Pole 36 KA, MCCB 180 Amp 3 Pole Contactor 110 Amp. Contactor 180 Amp Realy 66-110, Realy 14-23,SSP ,SP,MCCB 63 Amp, 3 Pole, Digital Meter Set, Hardware, Aluminium Bus bar Set, Wire & Thimble, Panel Box 16 Gouge.
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B?Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
75mm o/d PVC pipe of 4 Kgf. / sqcm
Providing, fixing and jointing ISI Marked Gun?Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete 65mm i/d Gun Metal peet valve heavy pattern.
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications.
Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications
Water Bound Macadam Grading I (without screening for low volume Roads/undersigned Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical specifications
Water Bound Macadam Grading II (without screening for low volume Roads/undersigned Roads Providing, laying, spreading and compacting stone aggregates of Grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical specifications
Providing and laying of Brick on end edging 6.83cm wide, 11.11cm long and 22.86cm high half brick deep including excavation, refilling and disposal of surplus earth up to 50mtr complete as per Punjab PWD specifications
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1kg per sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications
Providing and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical specifications
Providing, laying and compaction of open - graded premix surfacing of 20 mm thickness consisting of crushed stone aggregates of specified grading premixed in a Continuous type hot mix plant with bituminous binder VG-10 @ 1.46kg per sqm, laid with Paver Finisher Mechanical and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades complete as per technical clause 510 of MORT&H specifications
Providing and laying of premix sand seal coat premixed in Continuous type hot mix plant using specified fine aggregates and penetration grade bitumen VG-10 @ 0.68kg per sqm, laid to the specified levels, grade and cross fall complete as per technical clause 511 of MORT&H specifications
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge . IS Code: 15658 (2006)
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours
Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
Sand filling under floor and in wells of bridge foundation including handling within 100 metres
Providing and fixing pair of Plastic dustbins 100 litre volume each, of two different colours, for dry and wet waste, made of virgin plastic to be mounted on MS rectangular hollow section 50 x 25 x 3 mm frames pivoted on 3 MS square hollow section verticals, 1 m above ground, one 35 cm RHS welded to each vertical member at base and grouted in 180 x 40 x 30 cm 1:2:4 cement concrete.
Supply and installation of garden bench - Cast Iron bench of 1800 mm length, 900 mm width, 450 mm seating height, sides made of cast iron. Seat and back shall be made of 10 strips of M.S. pipes 63 mm x 25 mm of 14 gauge with one M.S. Flat 25 x 10 mm welded at the centre, below and back of the seat and back rest. Spray painted with approved brand paint. Fixed by grouting with 1:2:4 cement concrete (Minimum weight of each bench 105 kg)
Supply and installation of garden bench - Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation
Providing and fixing of garden fencing of green hexagonal net. Fixing of fencing with MS angles 25 x 25 x 3 mm frame, vertical members 1.5 m above ground fixed 30 cm in ground at 2m with cement concrete 1:2:4. Net to be fixed with nut bolts and washers.
Planting seasonal flower in beds - Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row.
Providing cement pots at site of work, filling 2/3rd volume with mixture of good earth and screened manure and cocopeat in the ratio 2:1:1.
35 cm size of pots
50 cm size of pots
60 cm size of pots
Providing and fixing steel tree guard
MS circular tree guard 60 cm dia and 1.8 mtrs. height above ground level formed of 4 Nos. of angle irons of 25 x 25 x 3 mm 2.10 m long, 4 Nos. 25mm x 3mm, 1.5 m long vertical MS flat welded to 3 no. 25 mm x 6mm M.S flat iron rings in two halves bolted together with 8mm dia & 30 mm long bolts and fixing 250 mm X 100 mm iron plate, fixed in ground with 1:2:4 cement concrete, complete in all respects.
M.S. Flat iron tree guard 45 cm square and 1.8 mtrs. height above ground level formed of 4 Nos. of angle irons of 25 x 25 x 3 mm 2.1 m long, 5 Nos. 25mm x 3mm horizontal MS flats welded to verticals on each side. Tree guard in two halves bolted together with 8mm dia & 30 mm long bolts, fixed in ground with 1:2:4 cement concrete, complete in all respects.
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling
Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position. For roof truss, well curbs, plate girders etc. of any span for building for bridges upto 15M span
Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:- Up to 15.00 Mtr. Span
Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.60 mm (+ 0.05 %) thick
Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge
20mm thick cement plaster damp proof course 1:3 with two coats of bitumen at 1.65 kg per Sqm laid hot and sanded
115mm thick wall laid in cement sand mortar 1:4 without reinforcement in super structure
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Congolmerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling using
Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling using
10mm thick cement plaster in 1:3
Hollock shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position- panelled, glazed or panneled and glazed - 40 mm thick door
Hollock wood cup board shutter with plywood panels or faced on both side fixed in position (excluding the cost of handles, bolts hasp with staple but including the labour for fixing them) - 30mm thick
Kiln seasonal Hollock wood cup board chowkats including iron hold fasts, iron hinges corner straps, wooden knobs or handles fixed in position (Size 45 x 60mm).
Applying Pink Primer or-aluminium priming coat including preparation of surface noting & stoping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered,
Applying priming coat with methal primer on new steel or iron work incluing preparation of surface and Painting two or morer coats including priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work.
Steel work, fixed independently without connecting plates, including cutting, hoisting and fixing in position
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete - Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter
White washing 3 coats inside of pump chamber
Finishing wall with exterior decorative cement based paint such as snowcem robbiacem etc. on new work in two coats to give even
Providing and fixing of Glass strips 4mm thick in floors 50mm wide
Providing and fixing of Glass strips 4mm thick in floors 40mm wide
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of
Distempering with dry distemper of approved manufacture two or more coats over one priming coat to give an even shade.
Supplying & fixing glass panes with glazing clips and special metal sash putty of approved make.
RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in
Wiring fan point without fan box
Wiring light point
Wiring 6 Amp. Plug control comprising wall socket point.
Wiring 16/20 amp. power plug control point.
GALVANIZED IRON PIPES AND G.I. EARTHING:Supply & erection of G.I. pipe (A-Class) as per IS:1239 (Part-I) 2004 including sockets, bends, inspection boxes, Steel hooks, GI saddle Earthing with 8 S.W.G. (4/mm dia.) G.I. wire in 15mm dia pipe with G.I. reducing socket 50mm x 15mm (upto
Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4meters above plinth level
First class 115mm thick honey comb brick work laid in cement mortar 1:4
115mm thick wall laid in cement sand mortar 1:4 without reinforcement in super structure
12.5mm thick cement plaster 1:6
Extra for fixing hold fast complete in all respects (LS) for M/S steel gate work
Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position.For roof truss, well curbs, plate girders etc. of any span for building for bridges upto 15M span. Span as per analysis attached A-4-1)
Black Granite stone tiles 15mm to 20mm thick
Engraving Charges (LS) for MS Steel Gate to the entire satisfaction of Engineer -in - Charge
115mm thick brick wall in cement sand mortar 1:4 without reinforcement in foundations and plinth
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43Iitre/10 Sqm over and including base
12.5 mm thick cement plaster 1:2
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).(CSR 29.36 d) 455x610 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).(CSR 29.36 d) 450 mm i/d clear inside opening rectangular RCC Manhole cover with frame Light Duty
Boring with casing pipe for tube well in all soils excepth ordinary hard rocks requiring blasting including removing the casing pipe after the tubewell is lowered & tested equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc, complete in all respect Boring with 250mm id Housing Pipe (CSR 28.72 (c))
Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818-2010, including required hire and labour charges, fittings & accessories etc. all complete for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. (CSR 28.92 (c))
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. (CSR 28.93 (c))
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect. 200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness (CSR 28.79 B
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. - 200mm internal diameter (CSR 28.80 (c))
Extra for Circular Brickwork CSR 11.69
Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- 'Bottom Layer :----- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry). (CSR 28.51 e)
Supplying and placing of fine gravel 20mm to 25mm crushed bajri CSR 28.51 d
Fourth Layer :----- Bajri (Coarse) screened, cleaned and washed and graded from 6mm to 20mm (from Pathankot or approved equivalent quarry).CSR 28.51 c
Second Layer :----- Coarse sand screened, cleaned and washed and graded from 3mm to 6mm (from Pathankot or approved equivalent quarry). CSR 28.51 b
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). - RCC Man hole cover with Frame - 560mm i/d RCC man hole cover with frame as per ISI - Heavy duty - RCC Man hole Cover CSR 29.34 A (ii) size 560 mm i/d heavy duty
Providing, Stringing out, cutting, Jointing and testing of C.I. Double Flanged pipes with screwed flanged as per IS: 1536, class 80mm i/d pipe lines laid complete.
Providing & fixing C.I/D.I. Flanged end, stem of SS (AIS 1410) and Bronze (Gunmetal) working parts Sluice Valves ISI marked 80mm i/d Sluice valves flanged.
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete C.I Double air valve (Size 40mm)
Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make - 40mm i/d
Providing, laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make - 15mm i/d
Providing ISI marked G M ferrule as per IS 2692 ,drilling and tapping CI pipe lines of all dia and screwing in pipe for fixing 20mm i/d Ferrule heavy duty
Providing ISI marked G M ferrule as per IS 2692 ,drilling and tapping CI pipe lines of all dia and screwing in pipe for fixing 10mm i/d Ferrule heavy duty
Providing, fixing and jointing ISI Marked Gun-Metal Peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe 40mm i/d Gun Metal peet valve heavy pattern
Nuts and bolts of all sizes and lengths required for 150 mm i/d
Providing & fixing ISI Marked Non-retun valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing 80mm i/d Non-retun valve
P/F of V-Notch duly I.S.I. Marked
Supplying and laying C.I. specials as per IS:1538 complete as desired by Engineer-in-Charge conforming to ISI specifications. C.I. Specials upto 300mm i/d
C.I. D/F Bend duly ISI marked 80mm x900 2x wt @ 14kg/ each
C.I. A/F Tee duly ISI marked 80mm 1xwt @ 23 kg/ each
D.I. A/E Tee for Air valve duly ISI marked 80x80x800 1xwt @ 22 kg/ each
D.I. D/F Duck foot bend duly ISI Marked 80mmx900 1xwt @ 21 kg/ each
C.I. Blank flange suitable for 80mm i/d pipe duly ISI marked 80mm i/d 2xwt @ 5 kg/ each
Blank flange duly ISI marked - 80 mm i/d 1xwt @5kg/each
Rubber Jain 80MM
Cement Concrete 1:5:10 with stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumeturic type
Any other Item
SHIVA ENTERPRIZES (BID ID -672135)
MS RAM KUMAR BANSAL CONTRACTOR (BID ID -669174)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_296628.xls
BOQ • 0.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .