VCB control panel and tripping relay
2024_PVVNL_921680_5
ET No. 152/W/EUDC/SRE/2023-24
Open Tender
Electrical Works
Lump-sum
30 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer
₹7,990
Yes
25 Jun 2024
11 Jun 2024
19 Jun 2024
11 Jun 2024
19 Jun 2024
11 Jun 2024
Amount
Safe Carriage of 11KV VCB incoming from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of 11KV VCB outgoing from PVVNL, Store to site including loading & unloading both ends.
Disconnection of old & defective 11kv VCB.
Dismenteling and removel of existing 11kv VCB from control room.
Safely installation of 11kv VCB in control room as per resspo norms.
Earthing of VCBs up to water leavel by boaring & fixing of 60 ft. deep G.I. Pipe of class 'B' 1.5" dia and connected with G.I. strip of size 30x5 mm including providing GI Strip, GI pipe, charcoel & salt by contractor itself as per resspo norms.
Re connection of New 11KV VCB incoming/outgoing as per Resspo norms.
Carriage of old & defective 11kv VCB incoming/outgoing from site to PVVNL, Store including loading & unloading at both ends.
Carriage of other meterial scrap from site to PVVNL, Store including loading & unloading at both ends.
Safe Carriage of 33KV control panel for single T/F from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of 33KV CT from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of 33KV PT from PVVNL, Store to site including loading & unloading both ends.
Disconnection of old & defective 33kv control penel.
Dismenteling and removal of existing 33kv control penel
Safely installation of 33kv control panel as per resspo norms.
Safely installation of 33kv CT as per resspo norms.
Safely installation of 33kv PT as per resspo norms.
Dismantling & carrige old and diffective 33kv CT/PT from site to PVVNL store.
Safe Carriage of PVC CU control cable 6x2.5 sqmm
Laying & fixing of PVC CU control cable 6x2.5 sqmm
Earthing of 33KV control panel up to water leavel by boaring & fixing of 60 ft. deep G.I. Pipe of class 'B' 1.5" dia and connected with G.I. strip of size 30x5 mm including providing GI Strip, GI pipe, charcoel & salt by contractor itself as per resspo norms.
Re connection of New 33kv control penel as per Resspo norms.
Carriage of old & deffective 33kv control panel from site to PVVNL, Store including loading & unloading at both ends.
Supply of 11 KV VCB tripping protection realy schneider make as per resspo norms
Safely installation of 11 KV VCB tripping protection realy schneider make as per resspo norms
Carriage of old & defective 11 KV VCB tripping protection realy from site to PVVNL, Store including loading & unloading at both ends.
Safe Carriage of 33 KV VCB incoming from PVVNL, Store to site including loading & unloading both ends.
Disconnection of old & defecting 33kv VCB incoming.
Dismenteling and removing of existing 33kv VCB incoming from plinth.
Safely installation of 33 kv VCB plinth as per resspo norms.
Earthing of 33 VCB with existing earthing system as per resspo norms.
Re connection of New 33KV VCB incoming as per Resspo norms.
Carriage of old & deffective 33 kv VCB incoming from site to PVVNL, Store including loading & unloading at both ends.
GYAS PAL CONTRACTOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .