SE TNC JPR CITY RVPN JAIPUR
Office of the SE TNC JAIPUR CITY AJMER ROAD 400 KV GSS PREMISES HEERAPURA, JAIPUR
Emergent repair of faulty 132 KV New Jhotwara VKIA U G XLPE Cable R and Y Phase 1200 Sq. mm laid between 132 KV GSS New Jhotwara to the termination tower near Newaru Puliya under 132 KV GSS New Jhotwara.
2025_RRVPN_457983_1
BN 2210002502/TN 107
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Jhotwara
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,950
As per Bid documents
₹88,880
Yes
8 May 2025
10 Apr 2025
22 Apr 2025
10 Apr 2025
22 Apr 2025
10 Apr 2025
Amount
MAIN MATERIAL / ITEMS -under ground cable section for R and Y phase.
132 kV, Single Core, 1200 Sq. mm XLPE Copper Cable as per foregoing specification requirements
145 kV rated voltage premolded Straight Through Joint suitable for the above underground cable (for cable length 500 meters each) as per foregoing specification
145 kV rated voltage premolded Straight Through Joint (with provision for sheath separation for cross bonding) suitable for the above underground cable (for cable length 500 meters each) as per foregoing specification
Cross bonding Link box, Co-axial bonding cable, sheath Voltage Limiters(SVL) complete with associated accessories for each 3-phase circuit.
Warning Tapes as per Specification
HANDLING,TRANSPORTATION TO SITE & LAYING OF 132 KV, SINGLE CORE, 1200 SQ MM XLPE COPPER CABLE AS PER FOREGOING SPECIFICATION REQUIREMENTS.
REMOVALE OF EXISTING 132 KV CABLE,INCLUDING OF CLEANING OF PIPES ETC
Handling & making of straight through joints for 132 KV, single core, 1200 Sq mm power cable (XLPE copper cable) as per specification.
Handling and making of straight through joints (with provision for sheath separation for cross bonding) for 132 kV single core power cable as per specifcation.
Installation of Cross bonding Link box, Co-axial bonding cable, Sheath Voltage Limiters (SVL) complete with other associated acessories for each 3-phase circuit.
Very low frequency with stand Test on 132 KV Power Cable duration 15 mint. Maximum voltage 84 KV RMS (per core charges)
VLF Tan Delta and VLF partial discharge test on 132 KV Power cable as per IEEE standards maximum voltage 84 KV RMS
Mobilization of equipmnts and site visit charges
Charges of conducting pre commissioning tests as per specification & successful commissioning of circuit
Cutting Black Bitumen surface upto any depth including all layers of crust for laying Power Cables etc, staking of useful material and disposal of surplus debries including all leads including barricading, providing danger board/diversion board, lighting, reflectors etc.
EARTH WORK IN EXCAVATION FOR BURRIED CABLE TRENCHES INCLUDING BARRICADING, PROVIDING DANGER BOARD/DIVERSION BOARD, LIGHTING, REFLECTORS ETC.
P&L CEMENT CONCRETE IN R.C.C. WORK IN FOUNDATION,RAFTS,FOOTINGS,STRAP BEAMS, BASES OF COLUMNS ETC. M-20 GRADE MIX 1:1.5:3
BRICK WALL WORKS, IF REQUIRED
132 KV Straight Through and Cross Bonding Joint Bay Brick Work
Providing & Laying HDPE pipe heavy duty of approved make jointed with solvent cement (i) 250 mm dia. (for 3 phase formation)
Supply and laying inter locking RCC cable covers as per approved drawing
Supply, spreading of clean river sand in the cable trench and cable joint pit as per specification.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .