Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.6 L+₹52,692.70 (2.11%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹27.5 L+₹2.5 L (9.82%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹28.8 L+₹3.7 L (14.9%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹29.3 L+₹4.2 L (16.9%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
4 Nov 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair / maint of LT overhead line, LT underground cable and connected items in KLP area and ASCON Nodes under GE (Army) Suratgarh at Suratgarh Mil Stn
2020_MES_383648_1
GE (A) SOG - 50/20-21
Open Tender
Civil Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹70,000
Yes
1 Jan 2021
5 Oct 2020
6 Nov 2020
5 Oct 2020
4 Nov 2020
19 Oct 2020
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable continuous GI earth wire / guard / cradles of any size complete all as specified and as directed by Engineer-in-charge.
Disconnecting and re-stretching ACSR conductor of any size and re-fixing with and including new 2mm dia aluminum binding wire complete all as specified. Note :- (i) The rate quoted by the contractor shall deemed to be included for cutting / trimming of tree branches touching / approaching the LT over lines upto 3 metre width on each side with hacksaw / axe to clear the LT line including disposal of trimmed branches 100 metre away inside the cantonment area & cleaning site as directed by Engineer-in-charge. (ii) Length of each conductor shall be measured as one length.
Supplying, fixing & stretching aluminium conductor steel, reinforced (ACSR) of any size fixed on LT poles fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by Engineer-in-Charge. Notes: - (i) The ACSR conductors shall be conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also be deemed to include for supply and fixing of binding wire, aluminum tapes etc. which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size multiplied by length of span and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.
S&F GI wire including stretching on LT poles as contineous earth wire or for guarding and cradles including binding as required complete all as specified and directed by Engineer-in-Charge. Note: -(i) For payment purpose, weight of galvanised wire shall only be considered. Clamps, eye hooks where provided shall be measured and paid for separately
S&F in replacement shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement pin type insulator of size 100mm height, 65 mm dia porcelain, vitreous white, brown or green insulator suitable for 1100 volts grade including one galvanized mild steel spindle, two GI washer and one GI nut complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge.
Blank
Supplying, installing, testing and commissioning of thermoplastic polycarbonate IP 65 outdoor type in accordance with EN 60 529 (dust proof, weather proof & water proof) power distribution board of suitable size as per Engineering practice, shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extingushing, UV Resistant, silica and halogen free recyclable material, glow wire tested at 960⁰C in accordance with IEC 60 695-2-11. type tasted as per IEC 61 439-1. total insulated with system. The manufacturer of board / panel shall submit a copy of ASTA certification by CPRI for the Degree of ingress protection in accordance with IEC 60529. The gasket material shall be polyurethane while the gasket shall be internally embedded including provision for taking incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable , danger board, detachable plate at bottom for cable entry etc. with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs. The manufacturer of board / panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 61 439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (i) Tempreture rise. (ii) Dielectric properties
Contd/-... Srl Item No 12 (iii) Short circuit withstand current - rated peak & short time with stand current and rated conditional short circuit current. (iv) Efffectiveness of protective circuits (v) Clearance & Creepage distance (vi) Degree of protection (vii) Mechanical operation The impact strength of polycarbonate enclosure / boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm with and including following accessories :- Incoming (a) 500 Amps copper bus bar for phases and 200 Amps for Neutral - 01 Set (b) MCCB 320 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 422006 or equivalent in ABB / L&T / Schneider Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 04 Nos Make - Legrand Cat Part No DPX³ 160 420053 or equivalent in ABB / L&T / Schneider (b) Internal all links & control cable and indicators - set of three Make of LT panel :- Hensal / GE / Schneider
All as per item No 12 above but comprising of following accessories Incoming (a) 600 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 400 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 422007 or equivalent in ABB / L&T / Schneider Outgoing (a) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 420249 or equivalent in ABB / L&T / Schneider (b) MCCB 160 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 420057 or equivalent in ABB / L&T / Schneider (c) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 420055 or equivalent in ABB / L&T / Schneider (d) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
S&F in replacement heavy duty TPN bus bar chamber 63 Amps, 4 way fixed with hinges and locking arrangements, wall mounting type and arrangements for 4 Nos incoming / outgoing connections in each bus bar fixed on wall complete all as specified & directed by Engineer-in-Charge. Make :- Havells Cat Part No IHBC006304 or equivalent in Legrand / L&T
S&F in replacement heavy duty TPN bus bar chamber 100 Amps, 4 way fixed with hinges and locking arrangements, wall mounting type and arrangements for 4 Nos incoming / outgoing connections in each bus bar fixed on wall complete all as specified & directed by Engineer-in-Charge. Make :- Havells Cat Part No IHBC010004 or equivalent in Legrand / L&T
S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
Disconnecting over head conductors and insulators any Nos on existing damaged steel tubular swaged LT poles, dismantling MS work such as cross arms /clamps/hooks etc, stay and street light (where exists), excavating and taking out damaged pole making good hole to receive new pole and S&F in same position new steel tubular swaged pole 09 meter long type 410 SP-31, re-fixing the MS work cross arms/clamps/hooks etc and insulators retrieved from dismantling and re-jointing the conductors with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole number complete all as specified and as directed by Engineer-in-charge.
M&L for painting on steel tubular poles 9 metre long including attachments (cross arms, clamps GI pipes etc) complete with one coat of aluminium paint after preparation of steel surfaces and black & yellow strips 30cm each upto 1.5 metre height from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (Black) in 80mm high letters over 150mmx230mm yellow base complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of PCC pole and applying two coats of synthetic enamel paint in black and yellow colour in alternate strips of 30 cm each upto 1.50 metre height from top of PCC coping and applying two coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with white synthetic enamel paint in 80mm high letters, over black synthetic enamel paint base of size 20cm x 20cm including applying two coats of white wash to coping of poles all as specified and directed by Engineer-in-Charge. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 25mm x 4mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts / nuts / washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engr-in-charge. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position (iv) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 240 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 21 above but cable of cross sectional area 185 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 120 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 95 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 70 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 50 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 35 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 25 sq mm 3.5 core
All as per item No 21 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 21 above but cable of cross sectional area 16 sq mm 2 core
All as per item No 21 above but cable of cross sectional area 10 sq mm 2 core
Supplying, jointing and testing heat shrinkable type straight through jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 32 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 32 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 32 above but suitable for cable of size 240 sqmm to 300 sqmm.
Supplying, jointing and testing heat shrinkable type,out door type, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 36 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 36 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 36 above but suitable for cable of size 240 sqmm to 300 sqmm.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre) Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
Taking out old unserviceable underground LT Cable with strandad aluminium conductor 1100 volts grade cross sectional area 10 sqmm 2 core to 95 sqmm 3.5 core form trenches / floor / road / pipe / along poles and relaying in the same location after repair complete all as specified and directed by Engineer-in-Charge. Note : Excavation & earthwork shall be measured and paid seperately under respective items of BOQ.
All as per item No 41 above but cable of cross sectional area 120 sqmm 3.5 core to 300 sqmm 3.5 core
S&F in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
S&F in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1800mm long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator with over all dimensions 90x140mm and clearence of hole 25.5mm, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 45 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement air termination, single pointed aluminium rod 12 mm dia single pointed 300 mm long complete all as specified and directed by Engineer -in-Charge.
S&F in replacement galvanized iron strip of size 32 mm x6mm to be used as down conductor for lighting protection and to arrange ring main circuit for earth pit complete all as specified and directed by Engineer -in-Charge.
S&F in replacement Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 53 above but 50mm bore tubing
All as per item No 53 above but 40mm bore tubing
M&L for preparation of existing painted surfaces of Panel Board / Feeder Pillar box (indoor / outdoor type), area not exceeding 10 square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of writing SM / MES No / name of feeders etc. (not exceeding of height 5 cm each) including welding of broken panel door, tightening electric connection of switch gears and cleaning of vegetation all around the panels up to one meter from all sides complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX³ 160 420055 or equivalent in ABB / L & T / Schneider
All as per item No. 57 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 160 420056 or equivalent in ABB / L & T / Schneider
All as per item No. 57 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 160 420097 or equivalent in ABB / L & T / Schneider
All as per item No. 57 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 250 420249 or equivalent in ABB / L & T / Schneider
All as per item No. 57 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 630 422007 or equivalent in ABB / L & T / Schneider
All as per item No. 57 here-in-before but MCCB 4 Pole, 630 Amps rating, breaking capacity 50 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 630 422023 or equivalent in ABB / L & T / Schneider
S&F in replacement LT Line polypropylene composite phase separator, moulded or bolted type, overall length 360mm, width 25mm, thickness 12mm, suitable for 2-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement LT Line polypropylene composite phase separator, moulded or bolted type, overall length 640mm, width 25mm, thickness 12mm, suitable for 3-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement LT Line polypropylene composite phase separator, moulded or bolted type, overall length 940mm, width 25mm, thickness 12mm, suitable for 4-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement LT Line polypropylene composite phase separator, moulded or bolted type, overall length 1250mm, width 25mm, thickness 12mm, suitable for 5-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCB, four Pole 63 Amps, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge. Make :- Legrand Cat Part No 408702 or equivalent in L & T / Schneider / ABB
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm of range 0-200 Amp, single phase, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Phase indicator lamp assembly LED type complete with indicator lamp including making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
S&F in replacement LED post top 40 watt decorative circular design energy saving, IP 65 protection environmental freindly, long life aesthetically designed with symmetrical light distribution, cast aluminium body landscape luminaire with high power LEDs with polycarbonate type diffuser including two coat of black painting on existing post and cement work in base stand (spigot housing with decorative opal acrylic diffusser and IP 65 protection with all accessories complete all as specified and as directed by Engineer-in-charge. Make :- Crompton Cat Part No LPTO-4-CDL/M (Maple) / Bajaj Cat Part No BGCL 40W LED or equivalent in Phillips /Havells / Wipro / Syska
S&F in replacement LED garden light 15 watt decorative new generation, post-top, energy saving, environmental freindly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and IP 65 protection with all accessories complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat Part No CORALMINIPT15W LED757PSYMTOPC (CORAL, OPAL) or equivalent in Phillips / Crompton / Wipro / Syska
S&F in replacement 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
S&F in replacement 250mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
S&F in replacement heavy duty double break HBC fuses type switch unit four pole, 50 Hz, 415 volt, 100 Amps capacity with in sheet steel enclousre surface mounting type with side handle opeeration including 7 Nos fuses rating 100 Amps complete all as specified & directed by Engineer-in-Charge. Make :- Havells Cat Part No IHFNTW4100 or equivalent in Legrand / L&T --------------------------------------------------------------------- Note :- A sum of Rs. 272722/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 23 & 24 (Schedule of Credit) of Tender documents.
M/S GODARA CONSTRUCTION CO.
SRI SAI CONSTRUCTION COMPANY
M/s JUGAL KISHORE MISHRA AND SONS
GURDEEP SINGH AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .