Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC A 3 257 2ND FLOOR JANAKPURI ASALATPUR ROAD JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0007281 | WEST DELHI | DELHI | 110058 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.0 L+₹2,640 (0.12%)Rejected-Finance 97 19 JWALAHERI MARKET PASCHIM VIHAR NEW DELHI DELHI 110063 | WEST DELHI | DELHI | 110063 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹24.5 L+₹2.5 L (11.4%)Rejected-Finance 203 VARDHMAN ENTRANCE PLAZA LSC NASEERPUR DWARKA SECTOR 1A PHASE 1 NEW DELHI 110075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹24.9 L+₹2.9 L (13.2%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹25.1 L+₹3.1 L (14.0%)Rejected-Finance PO PS JANG DISTRICT TAWANG ARUNACHAL PRADESH 790104 | JANG | TAWANG | ARUNACHAL PRADESH | 790104 | L5 | Rejected-Finance Being L5 |
Tender Value
₹29.6 L
EMD Value
₹59,100
Closing Date
22 May 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Palam
HQ CWE (AF) Palam Delhi Cantt-10
CA NO CWE/PM/SP-37/2019-20 SPECIAL REPAIR REPLACEMENT TO BER COOLING APPLIANCES OF HQ WAC AND CAMERO COMPLEX UNDER GE (AF) SUBROTO PARK DELHI CANTT-10
2020_MES_330758_2
CA NO CWE/PM/SP-37/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Subroto Park
₹59,100
Yes
11 Jun 2020
4 May 2020
25 May 2020
4 May 2020
22 May 2020
8 May 2020
60 days
Amount
Supply, installation, testing and commissioning of hi wall split type AC unit (copper) invertor type, indoor/outdoor complete with cordless remote control unit with 5 star rating and minimum EER 4.5, single phase, 230 Volts, 50 Hz of capacity 1.5 TR suitable for CFC free refrigerant complete, all as specified and directed by Engineer-in-Charge. Note :- Copper tubing, drain pipe upto 3 metres length deemed to be included in the rate quoted. Additional length shall be measured and paid seperately.
Supply, installation, testing and commissioning of hi wall split type AC unit (copper) invertor type, indoor/outdoor complete with cordless remote control unit with 5 star rating and minimum EER 4.5, single phase, 230 Volts, 50 Hz of capacity 2.0 TR suitable for CFC free refrigerant complete, all as specified and directed by Engineer-in-Charge. Note :- Copper tubing, drain pipe upto 3 metres length deemed to be included in the rate quoted. Additional length shall be measured and paid seperately.
Supply, installation, commissioning of water cooler fully stainless steel electric driven single phase having approximate storage and nominal cooling capacity 150/150 litres (or nearest higher size) with minimum 5 star rating suitable for CFC free refrigerant single phase 230 V, 50 Hz complete with provision of drain water pipe of suitable dia and accessories complete, all as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning of refrigerator suitable for operation on 230 Volts, 50 Hz AC supply of capacity more than 310 litres upto 360 litres (or nearest higher size) double door type having minimum 3 star rating (2019) suitable for CFC free refrigerant complete, all as specified and directed by Engineer-in-Charge.
M&L for cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilled holes for bolts in any shape or size of angle iron 40mm x 40mm x 6mm and inclusive of two coats of synthetic enamel paint over one coat of zinc chromate for installation of condesning unit on the wall/ ground complete, all as specified and directed by Engineer-in-Charge.
S&F low density polyethylene pipes (LDPE) 20mm dia of pressure rating 6 Kg/Sqcm fixed to walls, ceilings or in floor etc including accessories, clamps and fastners complete, all as specified and directed by Engineer-in-Charge.
M&L for laying of copper tubing of dia 1/2" including insulation and brazing work complete, all as specified and directed by Engineer-in-Charge.
M&L for laying of copper tubing of dia 1/4" including insulation and brazing work complete, all as specified and directed by Engineer-in-Charge.
M&L for laying of copper tubing of dia 5/8" including insulation and brazing work complete, all as specified and directed by Engineer-in-Charge.
M&L for laying of copper tubing of dia 3/8" including insulation and brazing work complete, all as specified and directed by Engineer-in-Charge.
S&F PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable 1100 Volts conforming to IS-694 of size 2.5 Sqmm 3 core complete, all as specified and directed by Engineer-in-Charge.
S&F sheet metal single pole and neutral enclosure with two pin and earth plug and socket capacity 32 Amps complete with one No. SP MCB capacity 32 Amps complete, all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with under mentioned runs of S/C PVC in insulated but unsheathed FRLS cable of specified size with multi stranded copper conductor 1100 Volts grade IS:694 marked drawn through and including suitable size of rigid non metallic PVC conduit medium grade ISI marked (not less than 20mm dia) with fittings & accessories complete all fixed/laid concealed in wall and surface conduit on ceiling and also including the specified runs of specified size earth continuity conductors and relevant conduit with access shall be measured as a one runs length complete, all as specified and directed by Engineer-in-Charge. (a) Two runs of 6.0 Sqmm main cable and one run of 6.0 Sqmm size earth continity conductor.
M&L for point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 Volts grade FRLS IS-694 multi stranded copper drawn through and including non metallic rigid PVC conduit, PVC conduit fittings not less than 20mm dia and conduit accessories concealed in walls, roofs and floors etc including terminal boxes fabricated with 1.6mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screw for housing the switch socket outlet 3 pin 15 Amps and including provision of 2.5 Sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continiuty conductor and connection to common earth dolly complete, all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type single pole, one way, 15 Amps, 240 Volts complete, all as specified and directed by Engineer-in-Charge.
S&F multi purpose socket 6 Amps/16 Amps, 2 in 1, flush type complete, all as specified and directed by Engineer-in-Charge.
S&F PVC flexible fresh water connection pipe for 15mm dia piping 45 CM long complete with two Nos brass unions heavy duty complete, all as specified and directed by Engineer-in-Charge.
Disconnecting from mains dismantling taking down and depositing of old unserviceable split type AC 1.5 TR- 15 Nos, Split type AC 2.0 TR -02 Nos, window AC 1.5 TR - 18 Nos, Water cooler-08 Nos and Refrigerator - 02 Nos including connected accessories like refrigerant tubing stand electric cable etc at MES store complete, all as specified and directed by Engineer-in-Charge.
RefAir Technical Services
HVAC Engineering Co
BRIJ MOHAN LAL AND CO.
N K BUILDERS
J.P. Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .