Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.4 CrAccepted-AOC BLOCK D FIRST FLOOR COMMERCIAL COMPLEX KUNJ BIHARI AGRAWAL KORBA KORBA KORBA CHHATTISGARH 495677 | KORBA | CHHATTISGARH | 495677 | ₹2.4 Cr Quoted ₹2.5 Cr | 1 | Accepted-AOC NEGOTIATED VALUE |
| 2 | 2₹2.5 Cr+₹3.0 L (1.23%)Rejected-Finance GATE NO 3 DIBRUGARH NEAR LANCO POWER PLANT ANPARA SONEBHADRA | ANPARA | SONEBHADRA | UTTAR PRADESH | ₹2.5 Cr+₹3.0 L (1.23%) | 2 | Rejected-Finance L-2 Bidder |
| 3 | 3₹2.5 Cr+₹5.1 L (2.08%)Rejected-Finance | ₹2.5 Cr+₹5.1 L (2.08%) | 3 | Rejected-Finance L-3 Bidder |
| 4 | Rejected-Technical B 1101 TOWER 3 NX ONE TECH ZONE IV GREATER NOIDA WEST UTTAR PRADESH PIN 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | - | - | Rejected-Technical Documents not as per PQC |
Tender Value
₹2.4 Cr
EMD Value
₹4 L
Closing Date
20 Mar 2023, 6:00 pmClosed
SUPERINTENDING ENGINEER, O AND MC IV, DTPS, ANPARA
OFFICE OF SUPERINTENDING ENGINEER, O AND MC IV, DTPS, ANPARA
Routine, Prev. AND BD Maint Work of 500MW Generator Aux, GRP, AVR, Diff MCCs, DG Set, AMF, VFD Panel, Battery Charger, EOT Crane, HT LT switchgear, AC plant and Routine, Prev. Maint Work of HT Motor and Transformer in EMD I, 2X500 MW, DTPS Anpara.
2023_RVUNL_778469_1
W-ANP/D/O and MC-4/EMD1/6000001074
Open Tender
Electrical Works
Fixed-rate
731 days
DTPS ANPARA
AS PER PQC, TENDER DOCUMENTS
2 documents required · 2 mandatory
₹5,900
Dy. CAO, CFA AND BO, DTPS, Anpara
₹4 L
Yes
2 May 2023
27 Feb 2023
21 Mar 2023
27 Feb 2023
20 Mar 2023
27 Feb 2023
27 Feb 2023 - 20 Mar 2023
Amount
Round the clock Routine, Preventive & Breakdown Maintenance Work of 500MW Generator Auxiliaries, GRP, AVR, Different MCC, DG Set, AMF Panel, VFD Panel, Battery Charger, EOT Crane, HT/LT switchgear, and Routine, Preventive Maintenance Work of HT Motor, Transformer installed in EMD-I, 2X500 MW, DTPP, Anpara. Note: 12 Job for each 500MW Unit i.e., 1 Job Per Month per 500MW Unit.
Routine, Preventive and Breakdown Maintenance of Voltas make Centralized AC Plant Screw Chillers/ VAM and associated System installed in EMD-I, 2X500 MW DTPS, Anpara.
AC System (ACP-1) of Main Plant and associated area.
AC System (ACP-2), of Admin building Section.
Routine, Preventive and Breakdown Maintenance of 11KV & 33 KV Lines for FGD works & AWRS System Belwadah in EMD-I of 2X500MW, DTPS, Anpara.
AMC of 03 No.s 1500 KVA DG set & one No. 250 KVA DG set at 2X500 MW DTPS Anpara. (Through OEM)
KTA50G8- 1500 KVA, DG Set#6
KTA50G8- 1500 KVA, DG Set#7
KTA50G8- 1500 KVA, DG Set Standby
6CTAA 8.3 G4- 250 KVA, DG Set
Emergency visit for 1500 KVA DG Set.
Emergency visit for 250 KVA DG Set.
Repairing of ESP controller cards installed in EMD-I, 2x500 MW, DTPP Anpara.
BHEL make ESP controller (BAPCON plus/ Erica)
BHEL make ESP controller (RAPCON-24/IntelliRAP)
BHEL make ESP controller (STATCON/IntelliSTAT)
REPAIRING ESP BUFFER CARD
REPAIRING ESP DATA COMM CARD
REPAIRING ESP FIRING/TRIGGER CARD
REPAIRING ESP MCRP CARD
REPAIRING ESP RELAY CARD
M/S SHYAM ERECTORS
M/s STAR ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .