REPAIR/ REPLACEMENT OF HT UG CABLES, VCB/ OCB/ LBS, OH LINE, TWO/ FOUR POLE STRUCTURE, LIGHTENING ARRESTERS AND REPAIR MAINTENANCE OF DISTRIBUTION TRANSFORMER AND OTHER ALLIED WORKS AT AFS TAMBARAM
2023_MES_616174_1
87627CWEAFNTBM
Open Tender
Civil Works
Item Rate
270 days
GE (AF) TAMBARAM
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (AF) TAMBARAM
₹40,000
Yes
7 Dec 2023
29 Aug 2023
11 Oct 2023
29 Aug 2023
4 Oct 2023
15 Sept 2023
30 Aug 2023 - 9 Sept 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in hard/dense soil all as directed.
All as per item No 1.00 above but exc 1.50m to n exc 3.0m depth all as directed.
Returning and refilling of excavated soil upto a depth of 30 cm after riddling the excavated soil for laying underground cables and post holes all as specified and as directed.
Removing excavated material not exceeding 50 mtr distance and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Supply and spread dry river sand in cable existing trench/duct for cable cushioning on top and bottom of the UG cable etc. all as specified and as directed
Supplying and laying un-reinforced precast concrete cable cover class HV, type 1, flat size 300x180x40mm for cable protection.
Labour only for laying of un-reinforced precast concrete cable cover class HV, type 1, flat size 300x180x40mm taken out from existing cable trench for cable protection all as specified and directed.
M&L for dehydration and filtration of transformer oil through on load mobile stream liner transformer oil filtration plant at various site and various capacity installed at pole,floor,plinth mounted with all accesssories connected to transformer to carrying out filtration of oil for desired dielectric strength all as per IS-335 i.e not less than 60 KVA at 2.5 mm gap including testing after filtration and recording before and after testing results, complete all as specified and directed. NOTE :-- (i) Transformer oil for filling/topingup shall be measured and paid saparately (ii) Oil level at the conservator tank should be in maximum limit. (iii) After filtration process,the test report to be submitted to the Engr-In-Charge
Labour only for taking up or down of old unserviceable HT underground cable of size 70 to 120 sqmm 3 core including making good the existing surface all as specified and directed.
Supply, laying and testing and commissioning XLPE insulated screened PVC bedded, galvanised steel strip electric power cables (heavy duty) armourmed cable 11000 volts grade with aluminium conductor of size 3 core 120 sqmm all as specified and directed. NOTE : - Earth work and excavation shall be measured and paid separately. (Make : HAVELLS/finolex/universal/Polycab/ASIAN/GLOSTER)
Taking out serviceable 11 KV HT UG cable from trenches and relaying the same in same or other location where directed for the size of 70 to 120 sqmm HT 11 KV grade 3 core for find out the defect/fault or diversion of the same complete all as specified and as directed. Note: [i] Earth work, excavation sand cushioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule. [ii] The rate deemed to including shifting of the cable from one location to other location. [iii] Necessary joints shall be measured under relevant items of this schedule.
Supply and laying 80mm bore GI tubing 'light grade' with all fittings for cable protection fixed on poles/walls/laid under road crossing or floor including making good the disturbed surfaces/area including taking down of old unserviceable complete all as directed. (Make: TATA/JINDAL/ZENITH/SWASTIK/PRAKASH)
All as per item No 12.00 but for 100 mm bore all as specified.
M&L for Cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) in Cutting of roads/ hard surface/ cement surface for any description to a size not exceeding 0.45x0.45m for crossing of cable and making good the surface even and rough all as specified.
Mild steel section for Cross arms, fencing post/bracing, supports, clamps and back plates etc fabricated including nuts bolts, washers, welding bending cold or hot drilling holes in any shape or size as indicated or directed incl dismantling/taking down of old U/S complete all as specified and directed.
M&L for cable jointing kit of 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm to 185 sqmm in repairs all as specified and as directed.
M&L for cable jointing kit of 11 KV (Earthed) grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm to 185 sqmm in repairs all as specified and as directed. (Make:- M Seal/Raychem/CCM/Birla 3-M/Denson)
All as per item No 16 but for HT Cable size 70 sqmm to 95 sqmm 3 core complete all as specified and directed.
M&L for cable jointing kits for 11 KV (Earthed) grade for straight through cold shrink type joint complete with jointing material and accessories suitable for 120 to 185 sqmm 3 core XLPE cable armoured aluminum conductor complete all as specified including taking out the damaged portion. (Make:- M Seal/Raychem/CCM/Birla 3-M/Denson)
All as per item No 19 but suitable to HT Cable size 70 sqmm to 95 sqmm 3 core complete all as specified and directed.
Supply and install test and commissioning of gang operated air break switch, vertical type triple pole, mounted on 3 insulator mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps for 11000 volts grade including connecting up locking arrangement including taking down the old unserviceable switch complete all as specified and directed. (Make: Pactil (Make:- Metro)/ Jaipuria/ Atlas/ ECE/ AREVA)
S&F connect in replacement of defective lightening arrestors distribution class MCOV 9 KV and discharge capacity 65 KA peak non linear resistance type with all fittings suitable for 11 KV electric working pressure including strap bolts and nuts and washers etc. all directed by Engr-in-charge. (Make: Oblum/ BHEL/ GEC-ELPRO/ Crompton& Greaves/ AREVA T&D)
Supply and install drop out fuse unit assembly single pole expulsion type suitable for HT 11 KV rated 100 amps including nut, bolts and washers with barrel fuse unit mounting on channel including taking down the old unserviceable assembly and making good the existing surfaces complete all as specified. (Make:- BHEL/Jay sree/ WS Insulator/ Southern Insulator/ Mysore Electrical Industries)
Supply and fix pin type porcelain, vitreous, white/brown/green insulator including one Galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut for 150mm height, 150mm dia suitable for 11000 volts grade complete including taking down old unserviceable insulator all as specified and as directed. (Make:- BHEL/BPCL/ MYSORE POCELINE/ Southern Insulator Jaipuria Co)
Supply and fix disc type insulator porcelain vitreous white, brown or green single disc assembly 145mm height and 255mm dia ball and socket type single dia assembly for tension with tension clamps for conductors and hard ware for working pressure 11000 volts complete including taking down the old unserviceable insulator all as specified and directed. (Make:- BHEL/BPCL/ MYSORE POCELINE/ Southern Insulator Jaipuria Co)
M&L for removing old/ burned out jumper connection in binding with HT/ LT lines from position including re-binding the same with new binding wire of suitable size aluminium wire all directed by Engineer-in-charge.
M&L for ACSR conductor of any size for LT/HT over head line wire and making jumper connections including disconnection and taking down of old unserviceable complete all as specified and as directed. (Make:- All-ind/ ICC/ Bharat Conductors/ NICCO/ Indian Aluminium Co.)
Supply and fix galvanised steel wire 3.15 or 4mm dia as in earth continuity conductors/ guarding cradles for LT OH line including taking out old unserviceable complete all as specified and directed.
Supply and fixing stay assembly complete with accessories as shown in electrical plate No. 1(loop type insulator ,stay clamp,excavation and concrete measured saperetly of size 16mm dia) incl taking down old U/S
Supply and fix galvanised stay strand 7/3.15mm including taking down the unserviceable stay wire from stay assembly and made good the disturbed places complete all as directed.
Supply and fix loop type insulator, vitreous porcelain, white, brown, green small size with overall dimensions 65 x 90mm, clearance of hole 16mm including taking out old and unserviceable insulator all as specified and as directed. (Make:- BHEL/BPCL/ MYSORE POCELINE/ Southern Insulator Jaipuria Co)
Surface dressing not exceeding 15cm deep in hard/dense soil including separating and pick and staking stone aggregate aside for reuse including spreading out the taking out materials such as aggregate and sand etc.in the installation yard of transformer/two/ four pole structure all as directed at site.
Supply and spread, depositing in layers, watered, rammed to true surface 63mm graded granite stone aggregate for installation yard all as directed
Servicing of two pole structure complete including replacement of unserviceable jumpers, sleeves, vice type connectors, bolts nuts washers connecting lugs/thimbles greasing the moving parts applying petroleum jelly on moving and fixed contacts, tightening all connection including make allignment of gang operated device and other all mechanism in the structure and cleaning of all insulators complete all as directed at site by Engr-in-Charge Note :- (i) The spares like insulators, Lightening arresters, GOD, GOD moving and fixed assembly, danger notice board etc shall be measured and paid under relevant items of this schedule. (ii) No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the schedule.
All as per serial item No 34.00 above but for four pole structure.
Supply only fixed contact knife for vertical/Horizontal operation (male) type
Supply only fixed contact knife for vertical/Horizontal operation (female) type
M&L steel tubular swaged poles 11 mtr overall length, type 410 SP-55 with cast iron base plate welded to the bottom of the poles finial taper plug nuts bolts and washers etc. including two coats of bituminous paint internally and externally for the portion bedded in concrete and two coats of aluminium paint over a coat of red oxide primer to external surfaces incl taking out of old unserviceable complete all as directed and specified. (Make: India Tube &Co/ India Electric poles Mfg Co. Maharashtra/ Quality Steel Products Ltd, Kanpur/ The Nationnal tubing Co. Kanpur/ Kalinga Tubes)
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles/stays all as specified.
Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles incl necessary formwork all as specified
M&L for painting of LT/HT pole including cross arms connected items with one coat of aluminium paint after preparing the existing surfaces of the poles and applying one coat alternatively yellow and black synthetic paint 30cm of each colour upto 1.50m height from bottom of pole above the ground level and marking of pole numbers with black paint all as specified and directed.
All as per item No 41 above but 2 Pole structure including all channels, cross arm and connected items complete all as specified and directed.
All as per item No 41 above but 4 Pole structure including all channels, cross arm and connected items complete all as specified and directed.
Cutting, trimming and pruning of trees/ tree branches of any girth upto 2m all around existing LT/ HT over head lines including cleaning the disturbed area beneath the LT/ HT overhead lines and removing the tree/ tree branches and debris from at site and depositing where directed at site. Note: (i) The rate quoted deemed included the entire currency of the contract. (ii) Approximate span between poles is 30 to 60m.
M&L for spray painting to Indoor/Out Door Transformers of capacity from 100 to 500 KVA any make & type with two coats of synthetic enamel paint of approved colour as specified over a coat of red oxide primer including necessary prepration of surface with wire brush emery paper for removing of dusts,oil/grease spots, water sweating spots etc all as specifide and directed. (Note: The above work includes writing SM/MES Nos (block , Roman, Indian) with thick synthetic enamel paint of approved shade in 5 cm height all as directed by the EIC)
M&L for spray painting to Indoor/Out Door VCB panel of capacity upto 630 Amps any make & type with two coats of synthetic enamel paint of approved colour as specified over a coat of red oxide primer including necessary prepration of surface with wire brush emery paper for removing of dusts,oil/grease spots, water sweating spots etc all as specifide and directed. (Note: The above work includes writing SM/MES Nos (block , Roman, Indian) with thick synthetic enamel paint of approved shade in 5 cm height all as directed by the EIC)
Disconnecting carefully the transformer of capacity of 315 KVA from HT and LT connections and taking out the transformer from its position and transporting/shifted it to out side work shop (if required), and transporting the same back to the site after completing the all necessary repair works, refixing/connection, testing and commissioning of transformer at site on full load all as directed by Engr-in-Charge.
Labour charges only for strip opening, lifting of core, re building the for pre testing to find out the defects, rebuilding with new copper binding wire of same/ existing size/gauge stripping off the transformer, including removing the Core and Winding from the internal tapping connection, de-brazing all the tapping and star points completely, disconnecting the tap switch for lifting the core and winding from the Transformer Body and separating the High Voltage and Low Voltage coils, if found any leak to be make good, reconnecting with necessary brazing all the tapping and internal connections as before after assembling the coil including replacement and re-arranging the Tap Switch Connecting leads, completely Silver brazing all the tap Switch contact & fixing the same with new oil seal, and using necessary insulating materials such as fiber paper nice sheets Leatheroid insulation sleeves, craft paper etc., for High Tension limb and low Tension coils and assembling all parts and assembly including improving the IR Value of Core and Windings through Hot Air Oven, cleaning tank, tubes, radiator, conservator tank (inside), building of new core, reassembling, No load loss measure & LV Coil and HV Coil assembling, star& delta connection, Cleaning, scratching of the outside & inside of the tank, two coats of Painting, replacement of breather, Replacenment of Transformer oil, improvement of IR value and conduction preliminary and final test repaired transformer complete all as specified and directed. (Note: Cost for "supply only" of the materials & replacement of HV&LV windings shall be measured and paid separately against item Nos 48 to 55 below)
Supply of insulating material ( Double Paper cover insulation) all as directed
Supply and fixing Breather assembly for transformer upto 500 KVA Capacities duly fitted with silica gel complete all as specified.
Supply of Low voltage Brass stud suitable to existing size for transformer terminal with brass nut, and washers 8 Nos. including rubber seat complete all as specified.
Supply of High Voltage Brass stud suitable to existing size for transformer terminal with brass nut , and washers 8 Nos. including rubber seat complete all as specified.
Supply only gaskets set with Cork/Neoprene sheet 6mm thick, nuts bolts, washers including all other sundry materials required for repair.
Supply only of paint of approved colour/make for internal surfaces of transformer tank complete all as specified and directed.
Supply only of paint approved colour/make for external surfaces of transformer tank including all connnected parts/items complete all as specified and directed.
Replacement/Rewinding the HV/LV limb with super enamelled copper wire of appropriate size as required to match with existing wire to have the same impedance complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 1 mtr x 2 mtr x 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and directed.
S&F of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters,figures and conventional skull and bones in single red colour and fixed with M S clamps, nuts and bolts of approved size, for HT, 25 x 20 cm size inculding taking down of old unserviceable complete all as specified and directed.
M&L for Refilling of Silicagel in breather of transformer various capacities including taking out of unserviceable Silicagel complete all as directed.
Supply, Toping up / replacement of transformer oil with dielectric strength not Less than 50 KV all as specified and directed. (Note;- Test Certificate of transformer oil as issued by the manufacturer will be produced by the Contractor).
Shifting of trolley mounted transformer upto 400 KVA from one Substn to other distance not more than 5 Kms carefully with tractor / Crane incl all Towing arrangement and taking out HT/ LT connections of defective transformer and connecting carefully HT/ LT connection at new site incl tamporary earthing connection complete all as specified.
Servicing to battery charging unit of HT VCB panel cubical type, dust and vermin proof floor mounted type 230 volts input and out put of 24 to 36 volts at a maximum current of 10 Amps for charging a battery bank of 24 volts 100 AH including replacing of internal wiring with suitable size of copper conductor and including replacing the following items :- (i) Supply and fixing sealed maintenance free battery of 12 volts/100AH 02 No's with connections fixed inside the charging unit - 01 Set (ii) MCB control for input circuit, DC out put circuit and battery path - 01 set (iii) Blocking diode in DC out put circuit to prevent reverse drainage of battery in charger - 01 Set.
Servicing to indoor HT 11KV VCB any make/type over current and earth fault relay secondary injection test any make VCB general service like cleaning, lubrication, Electrical/Mechanical operation check, Draw in/Draw out check, IR value check contact resistance test CT ratio and breaker tripping through relay by primary injection test, replacement of deterioted copper wiring kit with suitable copper conductor complete all as specified and directed Engr-in-charge.
Labour only for repair to HT VCB 11 KV 3 phase 630Amp 250 MVA of installed at Electric Sub Stations after disconnecting the main supply incoming panel for repairs and replacement of following parts and refixing the same after repair and testing on full load (cost of spare parts and other job works will be paid under respective items) complete all as specified and directed. Note : (a) Rates are deemed to include the cost of all tools, materials and labour required for dismantling taking out and assembling of VCB with replacement of worn out nuts and bolts gaskets A grade greasing and oiling of moving parts and refixing the same. (b) Rates are deemed to be included the cost of material and labour required to make alternative arrangement to bypass the electric supply through the HT panel or other HT line to avoid longer period of shut down of electric supply.
Labour only for inspection of relays including connections in existing VCB, Calibration of over current relay, calibration of earth relay, adjusting the setting of over current and earth fault complete all as directed. Note:- If any fault arises in VCB it should not travel to main VCB or Main grid of state.
Supply including replacement of single phase burnt motor of VCB with appropriate size of motor complete all as directed.
Supply including replacement of burnt closing coil assembly 24 V DC matching as per the existing complete all as specified.
Supply including replacement of auxiliary switch 24x24 pole fixed in trolley matching as per the existing complete all as specified..
S&F space heater for panel HT/LT panel electrical panel switch gear panel boards/ electronic insutuments panel heater box heater space heater 80 w complete all as specified and directed
S&F power pack input 230v/110v AC, out put voltage 24/30/48/110/220 VDC continuous load 110 VA impulse load 450VA for 240msec backup 15-20 min outout variation ± 2% no load VA burden during charging less than 70VA,led indication over voltage protection complete all as specified and directed
S&F Epoxy and DMC insulator bush bar support 11 KV of size 130mm long 60 mm dia complete all as specified and directed
supply only multifunction meter for VCB panel Make :AE
M&L for indentification/detection of HT cable fault of any size .The contractor responsible to bring the HT cable fault detector,HT insulation megger and vehicle transportation including connected accessories for detection of fault all as specfied and directed by Engr-In-Charge (Note :- HT cable jointing kit will be measured and paid separately).
M/L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4.0 mm dia by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I (2009). The quoted rate is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 mm CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed by Engr-in-Charge. Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI Wire length up to 7.50M will be measured as one unit) including taking down of old unserviceable.
M/L for earthing complete with copper earth plate electrode 60 x 60 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to 20 x 3mm copper strip by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 5 of SSR Pt I (2009). The quoted rate is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 mm CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed by Engr-in-Charge. Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, copper strip length up to 7.50M will be measured as one unit) including of taking down of old unserviceable.
M/L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth strip of size 32x6mm thick by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I (2009). The quoted rate is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 mm CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed by Engr-in-Charge. Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI strip length up to 7.50M will be measured as one unit) including taking down of old unserviceable.
G.L.THIRUMALAI NAIDU AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .