Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-Finance | L1 | Accepted-Finance Being Accepted | |
| 2 | L2₹28.9 L+₹2.0 L (7.61%)Accepted-Finance | L2 | Accepted-Finance L1 Being Accepted | |
| 3 | L3₹29.5 L+₹2.6 L (9.58%)Accepted-Finance | L3 | Accepted-Finance L1 Being Accepted | |
| 4 | L4₹29.9 L+₹3.0 L (11.1%)Accepted-Finance | L4 | Accepted-Finance L1 Being Accepted | |
| 5 | L5₹30.9 L+₹4.0 L (14.9%)Accepted-Finance | L5 | Accepted-Finance L1 Being Accepted |
Tender Value
₹25 L
Closing Date
4 Aug 2021, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
REPAIR REPLACEMENT MAINT OF LT EXT ELE SUPPLY AND UG CABLES INCL LT PANELS AND OTHER CONNECTING WORKS AT 9 MT AMMO DUMP DRIVING TRACK AND MKD AREA AT ARTY CENTRE UNDER GE GOLCONDA
2021_MES_459835_1
CA No. GE/Gol/21of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE GOLCONDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Exempted
21 Aug 2021
14 Jul 2021
6 Aug 2021
14 Jul 2021
4 Aug 2021
28 Jul 2021
14 Jul 2021 - 26 Jul 2021
Amount
Note for item Nos 1 & 2 : (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of same is deemed to be included in the rate qouted. (b) The cost shall also deemed to include for breaking of floors/ walls etc including digging of trenches for removing of cables loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. (c) The cost of repair work for increasing height of foundation by atleast one Feet from exisitng is inculded in the quoted rate for Item No. 02. (d) The panel shall be from a reputed CPRI Approved firm.
M & L Prestressed concrete pole, 9.0metres long 102 mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10 including taking down carefully the exisitng unserviceable Steel Tubular Pole/ Prestressed concrete Pole (size as per site), serviceable street light fitting and ACSR conductor including connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed. Note: (i) Excavation and earth work and PCC (1:4:8) type D2 as in foundation shall be measured and paid separately under relevant items.
M&L for PCC 1:4:8 type D2 as in foundation and mass concrete using 40 mm graded stone aggregate complete all as specified and directed.
S &L in trenches/ fixed to walls/ poles etc., testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor complete including taking out existing cable all as specified and directed for cable size 2 Core 6 Sqmm.
All as per item no.06 above but of size 2 core 10 Sqmm
All as per item no.06 above but of size 4 Core 16 Sqmm
All as per item no.06 above but of size 3.5 Core 25 Sqmm
All as per item no.06 above but of size 3.5 Core 35 Sqmm
All as per item no.06 above but of size 3.5 Core 50 Sqmm
All as per item no.06 above but of size 3.5 Core 70 Sqmm
All as per item no.06 above but of size 3.5 Core 95 Sqmm
All as per item no.06 above but of size 3.5 Core 120 Sqmm Note for item No. 6 to 14 :- Earth work & excavation, sand cushioning and brick protection shall be measured and paid separately.
M & L GI tubing , light grade, with all fittings 80mm dia for cable protection at road crossing / on poles, tubing sealed at both ends after laying the cables complete all as specified and directed.
M & L GI tubing , light grade, with all fittings 50mm dia for cable protection at road crossing / on poles, tubing sealed at both ends after laying the cables complete all as specified and directed.
S & F cable end termination jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable for cable 35 sqmm to 70 Sqmm 3.5 core complete including taking out old unserviceable one all as specified and directed.
S & F cable end termination jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable for cable 95 sqmm to 150 Sqmm 3.5 core complete including taking out old unserviceable one all as specified and directed.
S & F cable end termination jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable for cable 185 sqmm to 240 Sqmm 3.5 core complete including taking out old unserviceable one all as specified and directed.
S and F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for cable of size 35 to 70 Sqmm 3.5 core complete including taking out old unserviceable one all as specified and directed.
S and F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for cable of size 95 to 150 Sqmm 3.5 core complete including taking out old unserviceable one all as specified and directed.
S and F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for cable of size 185 to 240 Sqmm 3.5 core complete including taking out old unserviceable one all as specified and directed.
Supplying, fixing and stringing Aluminium Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator complete, on overhead line including taking down of existing conductor all as specified and directed.
M&L MS Cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers, welding, bending, cold or hot drilling holes for bolts in any shape or sizes as indicated or directed including of one coat of red oxide zinc chrome primer and two coats of aluminium paint, including removing the existing cross arms etc complete all as specified and directed..
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulators by removing ACSR conductor and refixing the ACSR conductor after replacement of pin type insulator complete all as specifeid and directed.
M&L Shackle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing shackle type insulator by removing ACSR conductor and refixing the ACSR conductor after replacement of insulator etc complete all as specified and directed.
S&F Stay assembly complete with accessories as shown in electric plate No.1 (of SSR- 2009, Part - I), stay rod 16mm dia, loop type insulator, stay clamps including excavation and earth work, PCC foundation etc., and taking out old unserviceable stay assembly all as specified and directed.
Tightening and straightening of LT overhead line of ACSR conductors(04 Nos LT Line conductors & 02 Street Light conductors) any size and span of upto 40 Meter by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed.
Tightening and straightening of LT overhead line of ACSR conductors( 04 Nos LT Line conductors ) any size and span of upto 40 Meter by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and clearing the distance 1.5 mtr on both sides of overhead line with in a gap of span 40 mtrs each and removing the same off the site all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread approved dry crushed stone sand for cushioning of cable laid in trenches complete all as all as specified and directed. Note:- Punned thickness shall be measured for payment purpose.
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed.
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm
M & L for road crossing /drain crossing by adopting trenchless tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydrolic pipe jacking technique complete including tunneling , excavation in any type of soils including hard rock, MS cassing,pipe heavy duty of size 100mm dia iwth 6mm thick in any length including jointing materials to carry LT UG cables of size upto 240Sqmm and necesssary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 25x4mm by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
S&F PVC separators suitable for LT over head line of 4 conductors all as specified and directed
S&F PVC separators suitable for LT over head line of 2 conductors all as specified and directed
M&L MCCB 415 Volts, 4 pole, adjustable type, 100 Amps, with breaking capacity 25 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 160 Amps, with breaking capacity 25 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 200 Amps, with breaking capacity 25 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 250 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 320 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 400 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L for cleaning thoroughly LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed .
Removing Existing unserviceable Analog voltmeter with electrical connections and supply and install,test the new voltmeter 0-500V all as directed and speicified at site.
Removing Existing unserviceable Analog ammeter with electrical connections and supply, install and testing new ammeter 0-250A/100A with necessary wires all as directed and speicified at site.
Removing Existing unserviceable Digital ammeter with electrical connections and supply and install,test the new voltmeter 0-500V all as directed and speicified at site.
Removing Existing unserviceable Digital voltmeter with electrical connections and supply and install,test the new voltmeter 0-500V all as directed and speicified at site.
Supplying, installing, commissioning and testing in repair factory made outdoor type LT Kiosk box with canopy of size 1000mmx600mmx450mm with 4 nos 200 Amps aluminium busbar and 4 nos aluminium lugs of size 40mmx5mm of length 75 mm made out of 3.15mm thick CRCA sheet duely powder coated and locking arrangement including grouting in PCC 1:3:6 type C-1 on stand made out of angle iron of suitable size and taking down old unserviceable one complete all as specified and directed.
Supply, fix, connect commission and test 3-Phase Heavy duty power capacitors MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirmed to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable Multi core multistranded with necessary lugs for inter connection of capacitor bank upto 4 KVAR complete all as specified including disconnecting and removing existing unserviceable power capacitor bank. and all as specified and as directed.
Supply, fix, connect commission and test 3-Phase Heavy duty power capacitors MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirmed to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable Multi core multistranded with necessary lugs for inter connection of capacitor bank of 5 KVAR complete all as specified including disconnecting and removing existing unserviceable power capacitor bank. and all as specified and as directed.
Supply, fix, connect commission and test 3-Phase Heavy duty power capacitors MPP out door type operating 3 phase 415 volt AC suply 50 HZ confirmed to IS:2834 complete with necessary bolts and nuts, earth strip connected from LT panel to capacitor bank including suitable copper cable Multi core multistranded with necessary lugs for inter connection of capacitor bank of 10 KVAR including disconnecting and removing existing unserviceable power capacitor bank all as specified and as directed.
S & Fix, connect and test Capacitive Duty Contactor for capacity 1 KVAR to 3 KVAR capacitor bank complete all as specified including disconnecting and removing existing unserviceable duty contactor all as specified and as directed.
S & Fix, connect and test Capacitive Duty Contactor for capacity 5 KVAR to 10 KVAR capacitor bank complete all as specified including disconnecting and removing existing unserviceable duty contactor all as specified and as directed.
Removing Existing unserviceable Intelligent power factor controller and supply and fix advance power factor controller 08 segment complete with electrical connections all as directed and specified at site. Make : Neptune -Ducati RM Series or Equivalent
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size including taking down old plate complete all as specified and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
SANJEEV CONSTRUCTIONS
M/S Veerabhadra Constructions
BHATNAGAR ASSOCIATES
M/S K Rama Rao
BUILDWEL
m/s s indra reddy constructions
Sri Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .