Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 CrAccepted-AOC 21 A 2ND STREET ARULANANDA AMMAL NAGAR THANJAVUR 613007 | THANJAVUR | TAMIL NADU | 613007 | ₹12.6 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹12.7 CrRejected-Finance | ₹12.7 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹16.0 CrRejected-Finance | ₹16.0 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹16.7 CrRejected-Finance | ₹16.7 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹16.9 CrRejected-Finance NO 9 DR SEVALIYE SHIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 624 001 | DINDIGUL | DINDIGUL | TAMIL NADU | 624001 | ₹16.9 Cr | L5 | Rejected-Finance Not being L1 |
Tender Value
₹12.8 Cr
EMD Value
₹9.6 L
Closing Date
30 Oct 2024, 6:00 pmClosed
Chief Engineer AF Bangalore
HQ CE (AF) Bangalore
PROVISION OF DEFICIENT OMQS AT AFS STATION AT THANJAVUR PHASE-1
2024_MES_659367_2
801629/E8
Open Tender
Civil Works
GE (AF) Thanjavur
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) Thanjavur
₹9.6 L
Yes
6 Dec 2024
2 Oct 2024
6 Nov 2024
2 Oct 2024
30 Oct 2024
16 Oct 2024
Amount
BOQ Dated Sep 2024
GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to XII are prepriced by MES under Ser No. 1 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Site Clearance and Area Development” as listed in Schedule ‘A’ Part – IV.
Lumpsum price worked out by the contractor for “Road / Path / Culvert " as listed in Schedule ‘A’ Part V .
Lumpsum price worked out by the contractor for "Sewage Disposal" as listed in Schedule ‘A’ Part VI .
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “COMPOUND WALL / GATE / FENCING” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for “RAIN WATER HARVESTING” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part – XI.
Lumpsum price worked out by the contractor for “E&M MISC WORKS” as listed in Schedule ‘A’ Part – XII.
Sch 'A' Part - XIII : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLY& INTERNAL ELECTRIC SUPPLY Supply and fix 15mm bore sink tap, brass CP dual flow patern with silcon black flexile hose swiel type complete all as directed.
Supply and fix 15mm bore washing machine tap brass CP complete all as directed.
Supply and fixing of LED light fitting study lamp 3watt white with collection of adjustable LED bed side light, 220 volt AC, not less than 120 Lm/Watt with driver, holder,three core flexible copper conductor cable of suitable size from ceillimg rose complete all as specified and as directed.
Supply and fix MCCB DB VTPN 4 way Vertical double door 415 V AC 50Hz with MCCB as incomer TP,DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completecomplete in all respect all as specified and as directed by Engineer-in-charge.
Material and labour for telephone wiring with unarmoured solid annealed bare copper industrial cable in concealed of size 0.5mm, 3 pair with PVC conduit 25mm dia complete all as specified and as directed.
Material and labour for TV wiring with unarmoured coaxial cable RG-11 in concealed with PVC conduit of 25mm dia complete all as specified and as directed.
Sch 'A' Part - XIV : Fittings / Fixtures & Misc items. EXTERNAN WATER SUPPLY& EXTERNAL ELECTRIC SUPPLY Material and labour for Cutting the existing DI/CI pipe of 150 mm dia and required length in position for inserting new Tees for branch connection including necessary arrangement for jointing materials with flanged socket joint complete fitting for main & branch etc. including excavation, refilling, ramming complete all as directed
Material and labour for construction of brick masnory valve pit chamber of size 900mm x 900mm x 1000mm (internal dimentions) with in CM 1:4 including base concrete PCC 1:4:8 mix, type D2 100mm thick, plastering with CM 1:4, 10mm thick internally and externally including provision of 5mm thick MS sheet cover fixed with 50x50x6mm angle iron embeded in PCC 1:2:4 mix, type B1 coping 100mm thick including painting to steel and iron work with two coats of synthetic enamel paint over a coat of red oxide primer and necessary earth work and excavation in any type of soil complete with locking arrangement lifting handles all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Shifting of Transformer having capacity of 100 KVA from Maintenance HQ or New MT area by disconnection of HT & LT Cables, Earthings etc.and reinstallation and re-connection as directed at new location complete and transformer shifting by using Hydra vehicle (Crane) including required labour and connected items complete installation as specified and directed.
Supply,installation ,commissioning and testing of HT 11 KV 3-phase 630 Amp Rating,21kA , 4 way (+CCVV + type), both side Extensible, compact, Outdoor, motor operated, Non drawout type SF6 Insulated with SCADA compatible RMU with 2Nos. Load Break Switch (OD) as Incommer(both Motor & Manual operated) (LBS/ Isolators) feeder and 2 Nos. fixed type motor operated vacume circuit breaker (CB) as outgoing with SAFEPLUS-XT compact SF6 gas insulated RMU including with all live parts enclosed in a robotically welded stainless steel tank of IP67 class of protection with Battery (Power backup unit), Bettery Charger, SF6 gas density manometer complete with Air Insulated Bus Connected Metering unit (M), all protection relay & unit with common item & accessories for RMU complete with foundation and all incommer & outgoing feeder connection complete all as specified and as per standard norms :- (a) Parameters of Ring Main Unit switchgear :- (i) Rated voltage (nominal/max) : 11KV/12 KV (ii) Type/service : SF-6 Ring main unit switch gear 4 way( with with 2Nos. Load Break Switch(LBS) Motorized Operated + 2Nos. circuit breaker (CB) with Motorized Sp charging mechanism / Outdoor "
(d) Provn for auto and manual charging of the operating system of 'ON' and 'OFF' (e) Provn of motor operated spring stored energy trip and closing coil system (f) Auxiliary switches as suitable for system at (d) and (e) above (g) Set of ring core type CTs ratio suitable to above system / capacity (h) Set of PT's resin cast, 3 phase, 11 KV. (j) Necessary HT & LT fuses for metering and protection (k) Power and control wiring with copper cables (l) Any other accessries, control which are required as per standard norms and engineering practice, IE rules to ensure system safe for operation and maintenance of Ring main unit switchgear. (m) Auxillary power supply unit (Power backup supply)for operation of relays, meters complete all as per standard norms. Note :- Unit rate shall included the cost of danger notice board, foundatio as per OEM recommendation/ all connection complete shall be included in the rate quoted. Make : ABB / Schneider / SIEMENS / LARSEN & TOUBRO (L&T)
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 400 Amps capacityBusbar, out door cubical type floor mounted factory made double door dust and vermin proof fabricated out of CRCA sheet not less than 3.15 mm thick outer sheet & 2mm thick inner sheet and fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, Digital meter with voltmeter, ammeter, slector switch, CTs, Control Fuse and Indicating Lights , danger notice plate, front & back openable doors with locking arrangements, PCC foundation etc and with the followings:- (a) MCCB 160A,36KA, 4 Pole adjustable thermal and adjustable magnetic (I/C)- 01 Nos (b) MCCB 40A,16KA, 4 Pole adjustable thermal and fixed magnetic (O/G)- 06 Nos (c) MCCB 25A,16KA, 4 Pole adjustable thermal and fixed magnetic (O/G)- 01 Nos (d) Digital meter with voltmeter, ammeter, slector switch, CTs, Control Fuse and Indicating Lights including with all pre-wired connection,- 01 Set (e) Digital Timer Switch for street light-01 Nos (f) Contactor with nominal current rating 25Amp TP -01 (g) Auto/manual switch option for Street Light-01
Supply and fixing in replacemnt moulding compound street light junction box of size 250 mm x 250 mm x 160mm complete with shock and rust proof , front openable type and including suitable provision for three phase, four wire cable incomming & outgoing loop -in loop connection and including one No. MCB SP 6 Amp including fixing clamps (30x4mm) and GI nut bolts and washers of suitable size and fixed on pole / wall complete.
Material and labour for construction of Transformer plinth foundation with PCC solid block masnory of size 1.8M x 1.8mm x 1M with in CM 1:4 including base concrete PCC 1:3:6, type C2 100mm thick after compact layer of hardcore, filling inside the foundation area with hardcore,murum sand and aggregate with compact all filling material and PCC Capping on top of foundation 1:3:6 type C2 of 100mm thick including rendering 10mm thick outer surfaces of wall, vertical cable duct for cable entry including with complete earth work Excavation, R&F, removing etc. and three coats of white wash over the rendered surfaces all as specified and directed.
Material and labour for Cable route indicator showing " MES LT UG Cable" and route of cable with arrow made of CI in suitable eliptical/round shape and fixed on angle iron 40x40x6mm, 800mm long painted in Blue Colour with two coats of synthetic enamel paint cover a coat of red oxide primer duly embaded in PCC block (0.40x0.40x0.40)mtr including in ground and 0.15mtr above ground lable complete all as directed and specified.
Supply & fixing PVC insulated FRLS unsheathed flexible copper conductor cable of size 1.5 Sqmm, multistranded, three core,1100 volts grade for connecting from loop in - loop out box to street light fitting complete all as directed.
Roof top Solar PV generation plant Design, Supply, installation, testing & commissioning of Roof top Solar PV generation plant of 2 KW capacity without battery backup, 3 Phase 415 Volt AC output, Grid tied with including as following components:- (a) Solar Photo Voltaic mono crystalline Silicon Modules with minimum 72 cells, with minimum 1100 mm (+) & (-) cable length including with end MC4 connectors. Module efficiency of not less that 17.0% fill factor >0.7, module will be PID resistant, module connector suitable for MC4/Bizlink and juntion box with minimum, IP 67 rating and rating of 250 Wp to 540Wp for total Capacity = 2KWp . (b) Solar Hybrid Inverter suitable for 2 KWp Solar Plant and three Phase AC output including with string combiner DC DB box with safety device and including with all DC and AC copper cables of size 6 Sqmm incl with suitable pipe with fixing arrangement and connection in each block Main AC DBs. (c) Galvanized mild steel fabricated Modules mounting structure (for 2KW Roof Top Solar power Plant) and suitable for the wind speed as per Wind Zone of plant location. including with All foundation & fixing arrangement shall be in according to manufactures drawing. (d) MMS and Inverter Earthing (GI Plate type) including Lightning arrestor with its separate earthing, strip with complete connected work as per OEM recommendation. Note:- Solar PV module shall be complying with DCR norms as per MNRE.
(Electric chimney) Supply and fix Electric chimney of size 90 cm ,wall mount type, filterless and suction power not less than 1200m3/hr capacity, auto clean chimney with airflow capacity 990 at maximum speed and minimum noise level (not more than 53 db at lowest fan speed), gesture and touch control type, Complete with all necessary accessories, duct etc and fixed in position including plugin arangement complete installationto make functional all as specified.
(EV Charging Point ) Supply & Fix Industrial enclosures box with Socket combination 32 Amp, 2 Pole and earth including with industrial insulated connector 32 Amp (plug top) and protection MCB DP of rating 32Amp,10KA, C-type, 230V AC complete all as directed.
SENSOR LIGHT SCHEDULE Supply and fixing automatic movement based sensor LED building security light fitting 24 watt , made out aluminium die-cast with rust proof powder coating, IP65, over voltage protection, including suitable bracket of GI pipe 32mm dia and clamps for fixing complete all as specified.
UNITED TECHNO PROJECTS PVT LTD (BID ID -3147678)
B5BUILDING SOLUTIONS (BID ID -3150322)
Saraogi Infrastructure (BID ID -3147916)
P Natesan and Co (BID ID -3147351)
Sushmaniti Constructions (BID ID -3146633)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid