| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.0 L+₹2.4 L (5.58%)Rejected-Finance C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTATIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.4 L+₹2.9 L (6.56%)Rejected-Finance C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹46.4 L+₹2.9 L (6.62%)Rejected-Finance OODLABARI P O MANABARI DIST JALPAIGURI WB PIN 735222 STATE WEST BENGAL | JALPAIGURI | WEST BENGAL | 735222 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹47.1 L+₹3.6 L (8.22%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹39.6 L
EMD Value
₹79,300
Closing Date
28 Oct 2023, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
PROVN OF SECURITY FENCING AND SPL REPAIR TO STREET LIGHTS AND CONNECTED WORKS AT DIFFERENT LOCATIONS OF BAGRAKOTE MIL STN UNDER GE SEVOKE ROAD
2023_MES_621089_1
8246/SEV OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹79,300
Yes
18 Jan 2024
29 Sept 2023
6 Nov 2023
29 Sept 2023
28 Oct 2023
14 Oct 2023
30 Sept 2023 - 9 Oct 2023
Amount
Excavating in post holes each n.exc. 0.5 cum and getting out in soft/loose soil incl returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering removing surplus soil to a distance n.exc 50m and making good surfaces complete all as directed.
Materials and labour for plain cement concrete 1:4:8 type D2(using 40mm graded crushed stone aggregated) as in foundation, filling and mass concrete all as specified.
Supply and fixing mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut 5 to 10mm dia shank and exc 5cm but n exc 10cm long all as specified and as directed.
Supply and fixing mild steel work as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
Materials and labour for preparation of new steel surfaces of any description, over 10cm in width or grith, and applying two coats of synthetic enamel paint over priming coat of red oxide primer complete all as specified and as directed.
Materials and labour for preparation of new steel and iron surfaces of any description, not exc. 10cm in width or grith, and applying two coats of synthetic enamel paint over priming coat of red oxide primer complete all as specified and as directed.
Supply and fixing mild steel 10mm dia round bar cut to length bent to shape required including cranking, bending fixed to chain link fencing wire and with clips or weding all as specified and as directed.
Supply and fixing galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised MS wire, staples or steel pins etc (Each line wire to be measured separately.)
Supply only chain link fencing with 4mm dia galvanised steel wire ,size of mesh 100mmx100mm complete all as specified.
Fixing only chain link fencing including line wires , any mesh, size and type to any type of standard, rails , straining bolts, etc including provision of binding wire complete all as specified
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, cable trench etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
Dismantling existing ACSR/earthwire (any size) from over head line after disconnecting connections and removing from site complete all as directed by Engr-in-Charge.
Dismantling insulators any type and any size and removing from site complete all as directed by Engr-in-Charge.
Dismantling of cross arm (made of MS channels/angles etc.) or clamps etc. and removing from site complete all as directed by Engr-in-Charge
Materials & Labour for clean river sand for cushioning below and above UG cable in trenches all as specified and directed by Engr-in-Charge. Note:- Punned thickness shall be measured.
Supply and laying fly ash brick of traditional size as cable protection all as specified and directed.
Materials & Labour for PCC (1:2:4) type B-1 (20 mm graded crushed stone aggregate) as in foundation or in any situation as required completed all as specified and directed.
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 120 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 95 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 70 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 50 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 35 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 16 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 16 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches LT underground Cable, XLPE insulated, heavy duty armoured sheathed 1100 volts grade 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and as directed
Supply and laying in trenches or under road/path or fixed to wall/pole GI tubing of 80 mm bore light grade with all fitting as cable protection complete all as specifed and directed.
Supply and laying in trenches or under road/path or fixed to wall/pole GI tubing of 50 mm bore light grade with all fitting as cable protection complete all as specifed and directed.
Materials & Labour for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Supply, install, testing & commissioning of approved factory made outdoor cubical type LT feeder piller Box (CPRI tested) outdoor type suitable for 3 phase 4 wire 415V,50 Hz, IP-54 of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 3.15mm thick CRCA (cold rolled cold annealed )MS sheet bend to shape, front & back side operated double door with proper hinge and locking arrangement with Al bus bar fixed on porcelain insulator and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of Cu conductor and coloured coded aluminium strips should be used for connecting all MCCBs from busbar either incoming or outgoing, also MCB SPN/TPN should be wired with 10sqmm FR coloured Al wire . Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platform all as specified and directed. LT panel board shall be complete in all respects with and incld the following accessories:
Supply, install, testing & commissioning of approved factory made outdoor cubical type LT feeder piller Box (CPRI tested) outdoor type suitable for 3 phase 4 wire 415V,50 Hz, IP-54 of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 3.15mm thick CRCA (cold rolled cold annealed )MS sheet bend to shape, front & back side operated double door with proper hinge and locking arrangement with Al bus bar fixed on porcelain insulator and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of Cu conductor and coloured coded aluminium strips should be used for connecting all MCCBs from busbar either incoming or outgoing, also MCB SPN/TPN should be wired with 10sqmm FR coloured Al wire. Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platform all as specified and directed. LT panel board shall be complete in all respects with and incld the following accessories:
Materials & Labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below normal ground level connected to galvanised iron strip 25 x 4mm earth lead by means of bolts,nuts,checknuts & washer of galvanised iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation & earth work in any type of soil, 20 mm dia medium grade galavinised steel tube for watering with one end fixed with cast iron funnel & wire mesh, 32 mm dia light grade galvanised steel tubung up to 7.5 meters length for drawing earth lead with filing of bentonite in 300 mm dia all around electrode etc complete.
Supply, install, testing & commissioning of approved factory made outdoor cubical type LT feeder piller Box (CPRI tested) outdoor type suitable for 3 phase 4 wire 415V,50 Hz, IP-54 of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 3.15mm thick CRCA (cold rolled cold annealed )MS sheet bend to shape, front & back side operated double door with proper hinge and locking arrangement with Al bus bar fixed on porcelain insulator and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of Cu conductor and coloured coded aluminium strips should be used for connecting all MCCBs from busbar either incoming or outgoing, also MCB SPN/TPN should be wired with 10sqmm FR coloured Al wire . Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platform all as specified and directed. LT panel board shall be complete in all respects with and incld the following accessories:
Supply and fixing in repair 5 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangement complete all as specified and as directed by Engr- in- Charge Make: kakatiya energy system Pvt Ltd Cat No. Swadeep 66-02EC-5KW 3P or equivalent of L&T/Havells/GE
Supply and fixing thermoplastic polycarbonate cable junction box having protection IP 66 "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 04 - 10 sqmm and 155x210x92mm with terminals, brackets for street light pole mounting and provision of one 6A MCB SP all as specified and as directed of make Hensel DK1610G or equivalent of L&T/Havells/GE
Materials & Labour for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing in repair new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium street security light with high power LED as light source lamp type 72W with "10 KV SPD, Efficacy > 110_LPW" IP 66 protection with toughened glass cover incl fixing GI pipe & bracket not less than 1.5 mtr long complete all as specified and as directed.
M/s. STRUCTURES INDIA
M/S DUTTA & DAS ENGINEERING CO.
AJOY PAUL
NARESH GUPTA
LIBERAL ENGINEER CONSTRUCTION
Manish Ray and Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .