Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹2.6 L (1.70%)Rejected-Finance | ₹1.6 Cr+₹2.6 L (1.70%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.6 Cr+₹5.4 L (3.54%)Rejected-Finance | ₹1.6 Cr+₹5.4 L (3.54%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.6 Cr+₹8.7 L (5.73%)Rejected-Finance NEERU WALA BAGH FIROZABAD UTTAR PRADESH | ₹1.6 Cr+₹8.7 L (5.73%) | L4 | Rejected-Finance L4 |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
30 May 2022, 3:00 pmClosed
Superintending Engineer
3rd circle irrigation works 139 Mall Road Pratappura Agra
Renovation of Circle, Division, Sub Division, DRO Office and Other Works.
2022_UPIDC_701160_1
7/SE/2022-23
Open Tender
Civil Works
Item Rate
180 days
Agra
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
₹3.2 L
Yes
15 Jul 2022
23 May 2022
30 May 2022
24 May 2022
30 May 2022
24 May 2022
Amount
Dismantling old lime or cement plaster including disposal of refuse as directed by engineer incharge within distance of 60 meter
Dismantling R.B. work including stacking of dismantled material as directed by engineer incharge within a distance of 60 meters (200 feet)
Earth work in foundation in dry ordinary soil (loam clay or sand) including lift upto 1.5M and lead upto 30M including back filling, watering and ramming of excavated earth into the structure and the sides of foundation trenches or into the plinth with removal and disposal of surplus earth as directed by Engineer in charge up to a distance of 30m from the foundation trenches.
Providing and laying cement concrete in 1:4:8 (1 Cement:4 fine sand:8 Graded stone aggregate 40 mm nominal size ) and curing complete, including cost of form work. In foundation and floors.(fine sand not less than in 1.25 FM)
Class 150 (Non Modular ) Brick work in 1:6 (1 Cement : 6 coarse sand ) including cost of all material T & P etc. required for the proper completion of the work
R.C.C. work with cement approved coarse sand and 20 mm gauge approved stone ballast in the proportion 1:1.5:3 (1 cement : 1.5 Coarse sand : 3 20 mm stone grit) including material labour T.& P. etc. required to proper complletion of work.
Bending, binding cutting and placing of reinforcement including cost of binding wire but including cost of steel.
Ordinary centering and shuttering for C.C./R.C.C. work
12mm Cement plaster in 1:4 (1cement:4coarse sand) mortar including cost of all material labour T & P etc. required to proper completion of work
White washing with lime on undercorated wall surface (Two Coat) to give an even shade including throughly brooming the surface two remove all dirt, dust, mortar, drop and loose scale of lime wash and other foreign
Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade and undacorated wall surface to give even shade over @ 1.25 Ltr/10sqm including one coat of primer appled @ 0.75Ltr/10sqm coat curing and cost of all material, labor, T&P etc. required for proper completion of work.
Painting on old wood work with superior synthetic enamel such as Luxol 3, Hi gloss Apcolite, Superlac, Dulux specified brushing to give and even shade and including the cleaning the surface of all dirt, dust and other foreign matter sand papering and scrapping including cost of all materials, labour, tools and plants etc. required for proper completion of work.
Dismantling cement concret floor including disposal of refuse as directed by engineer incharge within distance of 60 meter.
Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces upto 10cm width or girth or small articles not exceeding 0.10 Sq.M. in area with superior synthetic enamel such as Luxol 3, Hi gloss Apcolite, Superlac, Dulux specified brushing to give and even shade and including the cleaning the surface of all dirt, dust and other foreign matter sand papering and scrapping including cost of all materials, labour, tools and plants etc. required for proper completion of work.
laying Cement concrete flooring 1:2:4 ( 1 cement :2 coarse sand :4 graded stone of size 20 mm normal )laid in one layer finished with floating coat of neat cement ( 40 mm thick floor)
Providing and fixing glass strips of 4mm thick in joints of floor and skirting at the time fo laying Including labour, T&P etc. complete in all respect.
P/L integral cement based water proofing treatment BRICK KOBA including preparation of surface as required for treatment of roofs, consisting of comp. of the work
Providing and laying Vitrified tiles in floor with lean concrete of 500x 500mm sizes (thickness 10mm), with a water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, including grouting of joints. including 75mm thick base with concrete 1:4:8 complete as per E/I
P/L Black granite Polished stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Black Granite Stone quality
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners o``f required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge I/C Glazing, paneling and dash fasteners to be paid for separately) :
S/F of shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required . Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-Charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing stainless steel ( Grade 304) Gate including cost of material,labour,T & P, etc. completion of work as per Engineer -in -Charge
Providing and fixing 35 mm Thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.including ISI marked Stainless Steel butt hinges with necessary screws, Steel Handels, Siliding bolt, Door Stopper and tower bolt
Providing and making of sal wood chaukhats i/c fixing at site with cost of timber etc. complete direction as per Engineer-in-charge
P/F 12.50mm thick tapered Edge gypsum plain board contorming IS : 2095-Part-I false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes hould be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixingwith wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
Filling Stone Gravel 20 to 40 mm gauge in bed including cost of material, labour,T & P etc. complete as per Direction of Engineer In Charge.
Constructing brick masonry chamber (500x 700x450mm) for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per pecifications and having anufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Boring 10 cm dia up 60 M.depth in average type of strata containing sand and medium dry clay i/c labour T&P etc. complete work
Providing and fixing PVC pipe conforming to IS make working pressure 6 Kg/Cm incuding testing labour T&P and all complete fittings. 110mmdia
140mm dia
Supply and Fixing of Power Plug with 20amp/250volt flush type modular swith…… completion of work
Supply and Fixing of surface/flush mounting 4ways SPN distribution board without MCB complete.
S&F of 0.5 Amp to 5 Amp. SP MCB (10KA) C Curve cat A
S&F of LED Tube Light with batten suitable for upto 1x22 watt LED tobe light complete.
Supply & Wiring of Submain with two number 4sqmm FRLSH PVC insulated 1100Vgrade single core copper conductor cable in 20mm heavy duty PVC conduit with one no. 2.5 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth contunity wire drawn in conduit.
Wiring Point for light with 1.5 sqmm FRLSH PVC insulated multistrand single core copper conductor cable IN PVC conduit I/C Piano type switch complete
Wiring Point for fan/fresh air fan with 1.5 sqmm FRLSH PVC insulated multistrand single core copper conductor cable IN PVC conduit I/C Piano type switch complete
Boring 10 cm dia up 50 M.depth in average type of strata containing sand and medium dry clay i/c labour T&P etc. complete work
Providing and fixing PVC pipe conforming to IS make working pressure 6 Kg/Cm incuding testing labour T&P and all complete fittings 110mm pipe
Providing and fixing Chlorinated Pollyvinyl Chloride (CPVC)pipes having thermal stability for hot & cold water supply i/c all CPVC plain & brass threeded fitting This includes jointing of pipes & fittings with one step CPVC solvent cement trenching reflling & testing of joints complete as per direction of Engineer in charge . 32mm nominal outer dia pipes
Supply and wiring 4sqmm Three core PVC insulated cable for submersible pump.
Supplying and fixing 2HP submersible pump incuding testing labour T&P and all complete fittings
Supply & Fixing of Starter single phase MV..
Providing and fixing Chlorinated Pollyvinyl Chloride (CPVC)pipes having thermal stability for hot & cold water supply i/c all CPVC plain & brass threeded fitting This includes jointing of pipes & fittings with one step CPVC solvent cement trenching reflling & testing of joints complete as per direction of Engineer in charge. 25mm nominal outer dia pipes
Providing and fixing Chlorinated Pollyvinyl Chloride (CPVC)pipes having thermal stability for hot & cold water supply i/c all CPVC plain & brass threeded fitting i/c fixing the pipe with clamps complete as per direction of Engineer in charge 16mm nominal outer dia pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. 15mmdia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 15 MM DIA
Supply and hoisting of Sintex or equivalent high density polyethylene seamless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tank should be ISI marked, Sintex or equivalent. (500 lt.)
Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool oter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.
Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sqmm 4core
10 sqmm 4core
S & F surface/Flush mounting 6ways VTPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge
S&F of 63 Amp. 4 Pole Isolator CAT A
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect. CAT- AAA
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 100 to 120 Watt. Confirming to IP 65 protection complete in all respect. CAT-AAA
Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of harcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA
ONE KILOWATT SOLAR POWER PACK WITH VIRTUAL CLASSROOM DISPLAY complete.
Five KILOWATT SOLAR POWER PACK WITH VIRTUAL CLASSROOM DISPLAY complete.
Earth work in filling inluding all lead and lift with manual compation dressing etc. complete of work.
C.C. work with cement approved coarse sand and 20 mm gauge approved stone ballast in the proportion 1:1.5:3 (1 cement : 1.5 Coarse sand : 3 20 mm stone grit) including material labour T.& P. etc. required to proper complletion of work.
Laying of I shaped precast Interlocking tiles of thickness 60 to 100mm (Compressive strength not less then 30Mpa and weight 4.50kg) 80mm cloured
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint completion of the work.
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Turfing with chippi grass i/c ramming & watering.
Providing barbed wire fencing including fixing it to post after stretching including labour and T&P etc. for proper completion of work but Including supply of posts and wire.
Rajesh Yadav
Rakesh kumar
M/s HARSH CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .