Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹31.3 L+₹3.2 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Being Not Lowest Tenderer | |
| 3 | L3₹32.7 L+₹4.6 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest Tenderer | |
| 4 | L4₹32.9 L+₹4.8 L (17.1%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest Tenderer | |
| 5 | L5₹33.5 L+₹5.4 L (19.2%)Rejected-Finance DUDH LINE NAYAGAON VILL SHADIPUR POST SRI VIJAYA PURAM TEHSIL SOUTH ANDAMAN 744106 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744106 | L5 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
16 Nov 2023, 6:00 pmClosed
Garrison Engineer Wellington, Barracks Post, The N
Garrison Engineer Wellington, Barracks Post, The Nilgiris.
SPECIAL REPAIRS TO BLDG NO T-13, T-19, COMPOUND WALL AT SOUTH CAMP NEAR OFFICERS MESS AND SEWAGE LINE AT SOUTH AND NORTH CAMP OF 110 INF BN (TA) MADRAS AND EXISTING STORM DRAINAGE SYSTEM AND PROVISION OF CHEQUERED TILE WITH HARD STANDING ADJACENT
2023_MES_625031_1
8842/E8
Open Tender
Civil Works
Item Rate
180 days
GE Wellington
As per tender document
4 documents required · 4 mandatory
₹500
GE Wellington
₹64,000
Yes
2 Mar 2024
26 Oct 2023
21 Nov 2023
26 Oct 2023
16 Nov 2023
3 Nov 2023
Amount
Demolition of brickwork or stone/ boulder masonry, built in lime mortar/ cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Precast cement concrete 1:3:6 type C-1, using 20mm graded stone aggregate solid building blocks setting in cement mortar 1:4 complete in walls all as specified and directed.
Rendering 15mm thick on brick wall/ concrete surfaces in Cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking of shutters from the frames) area not exceeding 1.5 Sq mtr each all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified and directed.
Factory made solid panel PVC door shutter 30mm (Stile) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame all as specified and directed.
Anodised aluminium frame powder coated for doors, windows ventilators, U channels safety grill with one or more rebates including joining cleat for fixing complete all as specified and directed.
Anodised aluminium window and ventilators shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No) hinges type B-21 100mm long (2 Nos) suitable handle (1 No) complete all as specified and directed.
Ground or obscured or frosted on one side sheet glass 3 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane all as specified and directed.
Fancy type Steel PVC Coated, drapery rod of size 20-25mm dia, including fixing of Steel powder coated fancy brackets and end stops 2 Nos in each pane complete all as specified and directed.
Butt hinges extruded Aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type C-21, with MS hinge pin 100mm size all as specified and directed.
150mm long aluminium anodised barrel tower bolt of extruded section all as specified and as directed.
Aluminium anodised alloy handles fabricated type 150mm size all as specified and directed.
Taking up or down steel tubing and connections, bore of pipe 15 mm complete all as specified and directed.
15mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 laid and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Taking up or down steel tubing and connections, bore of pipe 20 mm complete all as specified and directed.
20mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 laid and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Taking down existing drain/ soil/ waste/ vent pipes of any description and in any position of any size all as specified and directed.
110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches, in floors or fixed to walls complete all as specified and directed.
PVC (SWR) bends any radius, 110mm bore with oval access door complete all as specified and directed.
PVC (SWR) bends any radius, 110mm bore complete all as specified and directed.
110mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door all as specified and directed.
75mm bore PVC (SWR) pipes single socketed, with rubber ring joints in any length, fixed to walls / laid in floors all as specified and directed.
PVC (SWR) bends any radius, 75mm bore with oval access door all as specified and directed.
75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement all as specified and as directed.
Vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) including seat cover, trap and connection to drain and flush pipe and fixed in repairs complete all as specified and directed.
PVC low level flushing cistern 10 litres capacity, white, syphonic action type, white, with inlet ball valve, float and handle PVC flush pipe, bracket etc including taking down unserviceable flushing cistern etc and fixed in repairs complete all as specified and directed.
Vitreous china wash basin, white, flat back, size 550 x 400mm including chromium plated, pillar tap, waste coupling, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand complete all as specified and directed.
Pillar taps, fancy type, 15mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe all as specified and directed.
PVC connections 15mm size with CP brass nuts of length 450mm and fixed in repairs complete all as specified and directed.
Stop valves 15mm dia bore of cast copper alloy, srewed down, high pressure with fancy type, chromium plated screw both ends for union and fixed all as specified and directed.
20mm dia Gunmetal, globe or gate valves (half turn type or wheel type), screwed both ends for iron pipe all as specified and directed.
Brass chromium plated shower rose 100 to 125 mm size, swivel type with arm, fixing with 15mm dia pipe fixed in repairs all as specified and directed.
Bib tap 15mm dia, long body, cast copper alloy, fancy type chromium plated for kitchen sink screwed down, screwed for iron pipe or ferrule complete fixed in repairs all as specified and directed.
Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
Aluminium anodised chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges including suitable bracket and fixed in repairs complete all as specified and directed.
Dismantling, floor hearth or wall tiling including cement mortar bedding complete all as specified and as directed.
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed.
Glazed ceramic tiles on vertical surfaces of wall etc, of size 350x250x7mm/ 450x350x7mm set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick in cement mortar 1:3 complete all as specified and as directed.
Complete removal of existing finishes any type and preparing surfaces of walls and applying two coats of oil bound distember over a coat of wall care putty including one coat of primer on old wall surface complete all as specified and directed.
Complete removal of existing surfaces and one coat of primer preparation of old plastered surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10Sqm over new surfaces complete all as specified and directed.
Preparation of old painted wooden surfaces exc 10 cm with or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Dismantling and removing water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs all as specified and directed.
Rotational moulded polyethylene water storage tank, ISI marked three layer (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified and directed.
Dismantling of corrugated steel sheeting, any gauge, thickness, including removing L-type or J-type bolts in roof covering complete all as specified and directed.
Dismantling of wall/ ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets and frame work all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated/ semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering and on chajjas fixed with self tapping screws all as specified and directed.
False ceiling with aluminium grid work (Size of grid 600x600mm) wit 35x25x1.5mm main tee and 25x25x1.4mm cross tee and wall angle and suspended with 2mm dia GI wire hooked to roof wirh needful adjustment bolts at an interval of 1.20 m centre to centre staggered and board with Eco board decorative type size 600x600x4mm thick finished with two coats of oil bounded distemper over a coat of primer on exposed surfaces all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard dense soil all as specified and directed.
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
100mm thick cement concrete type D-2 1:4:8 using 40mm graded stone aggregate as in sub base all as specified and directed.
Chequered cement concrete tiles with grey cement and pigment of size of 300x300x25mm thick set jointed and pointed in neat cement slurry including 15mm thick in cement mortar 1:4 bedding layer of mortar all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.50M in depth; for foundation, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4 using 20 mm graded stone aggregate as in foundations, including rafts, footing, foundations, beams, plinth beams, bases for columns, etc., basement slabs, under reamed piles and mass concrete etc complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface rough finished complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4 using 20 mm graded stone aggregate for columns etc, complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface of concrete complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4 using 20 mm graded stone aggregate for Beams, cantilevers, bressumers, lintels over 1.5m span complete all as specified and directed.
Use and waste of steel Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Fair finished surfaces of concrete flat complete all as speicified and directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
All as per item No. 66 hereinbefore but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in mortar 1:6 type C1 1:3:6 using 20mm graded stone aggregate complete all as specified and directed
External rendering 5mm thick in cement mortar 1:4 with water proofing compound (water proofing compound shall be used as per manufacturers instruction) over a coat of 10mm thick in cement mortar 1:6 over brick or concrete surface finished even and fair all as specified and directed
Preparation of newly plastered surface and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10Sqm over new surfaces complete all as specified and directed.
MS Steel work in tubular / post/ trusses/ purlin including special shaped washers base and bed plate cleat nut and bolt etc, complete using but welded tubes confirming to IS 1161-1979 graded St 240 all as specified and directed.
Preparation of new or untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick using soils all as specified and directed.
Galvanised mild steel concertina coil with outer dia of 600mm made of high tensile wire of 2.5mm having strength of 165Kgs/Sqm and the razor barb tape of 0.52mm thick with barb tape of 0.52mm thick with berb width of 12mm and length of 10mm and weight 43.47 gm/m coated with zinc 120gms / sqm having 45-50 loops with 3 clips per loop giving coverage of approx 5.5 to 6m per coil, complete all as specified and directed. Note: The linear length of compound wall only measured for payment purpose.
Galvanized 2 strand steel barbed wire 2.24 mm dia barded with 2 mm dia barbs at 75 mm spacing and strining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvinised MS wire staples or steel pins etc all as specified and directed. Note: Each line wire to be measured.
Demolition and breaking up drain pipe (salt glazed drain pipes, AC or RCC) set in cement mortar internal dia of pipes 150mm / 110mm including under and haunching of cement concrete all as specified and directed.
160mm (outer dia) PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors or in walls all as specified and directed.
75mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door all as specified and directed.
PVC (SWR) bends any radius, 75mm bore complete all as specified and directed.
Concrete bed to 160mm bore drain pipes in PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested all as specified and directed.
Concrete bed to 110mm bore drain pipes in PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Providing plain cement concrete type B1 1:2:4 using 20mm graded stone aggregate as in benching / copings including necessary formwork all as specified and directed.
Precast cement concrete, type B1, 1:2:4 using 20mm graded stone aggregate, set in cement mortar 1:4 as in cover slabs all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including tube light fittings, switches, ceiling roses, pendants, fan regulators, sockets etc and making good to the disturbed surfaces of walls, floors, roof etc all as specified and directed.
Point wiring with multistranded copper conductor 1.5 sq mm nominal cross-sectional area single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly One light point controlled by one modular switch complete all as specified and directed.
All as per item No 87 hereinbefore but one ceiling / Exhaust fan point controlled by one moduler switch all as specified and directed.
All as per item No 87 hereinbefore but one socket outlet 3 pin 5/6 amps on independent board all as specified and directed.
All as per item No 87 hereinbefore but with three runs of 2.5Sqmm single core PVC insulated FRLS cable 1100 Volts grated with multi stranded copper conductor IS:694:1990 with ISI marking for housing 16A power point complete all as specified and directed.
Modular switch one way 6A 240V AC 50 HZ SP one module all as specified and directed.
Modular switch one way 16A 240V AC 50 HZ SP one module all as specified and directed.
Stepped type electronic fan regulator modular press type complete all as specified and directed.
Modular socket 2/3 pin combined 6A 240V AC 50 HZ SP two module all as specified and directed.
Modular socket outlet 2/3 pin combined 16A 240V AC 50 HZ SP two module all as specified and directed.
Ceiling rose surface Bakelite three terminals 65x25mm PVC/ Polycarbonate isolated body all as specified and directed.
LED light fitting mirror type with high out put diffuser 2 feet, 1x 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specifie and directed.
LED light fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifie and directed.
LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with GI medium grade tube of 40mm dia, 1.5 metre long bend to shape 120 degree and 2 Nos of MS clamp 25x4mm of required length / size including nuts and bolts with one coat red oxide and two coat of silver metallic paint fixed complet all as specifie and directed.
Supply and fix in replacement MCB DB, SPN 12 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
Supply and fix 240V, 10KA 'B' curve Isolator SPN 40 amps current carrying capacity in the DB complete with connection testing and commissioning. Make: Havells/ Legrand/ C&S
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades and keep in custody for refixing complete all as specified and directed.
Hanging only ceiling fan and connecting up including cleaning of fan and blade and provision of flexible cable from ceiling rose or connector to fan complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20A MCB all as specified and directed.
Supply and fix 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP in the MCB DB complete with connection testing and commissioning all as specified and directed.
Earthing complete with GI earth plate electrode 60x60cmx6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 4mm dia protected by GI pipe light grade 15mm dia and connected to panel board / DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 cover slab, reinforcement with 6mm dia MS bars at 100mm dia both ways, MS hook 6mm dia MS bars etc complete all as specified and directed.
Cushioning to PVC cable using clean dry riddled soil obtained from excavation gently punning below/around cable complete all as specified and as directed. Note: Punned thickness only will be measured.
Well burnt bricks sub class ‘B’ as in protection of cable laid dry, flat abutting each other width wise complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 6 Sqmm 2 core laid in trenches / ducts/ fixed to wall/ pole/ inside panel/ drawn through pipe including cable glands and terminal sockets and taking down old unserviceable UG Cable etc complete all as specified and as directed.
Energy conservation LED flood light luminaries 120W energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light suitable for high mast application architectural façade and general purpose lighting including control gear connection with suitable size of cable and with clamp and nut bolt complete all as specified and directed.
Earthing complete with GI earth plate electrode 60x60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 32x6mm dia by means of bolts and nuts washers made out of GI and earth wire protected by Galvanized pipe light grade 15mm bore, 40 mm bore medium grade and connected to main control board all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick, RCC 1:2:4 cover slab with 6mm dia MS bars etc complete all as specified and as directed.
GI tubing light grade, ISI marked confirming to IS 1239 for protection of cable fixed in wall or laid on trenches size of pipe 40mm dia all as specified and directed.
p.chinnasamy
Narendran Enterprises
Sri ASK Constructions
M/S SHAJAHAN BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .