| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹38.8 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹38.8 L+₹2,196 (0.06%)Admitted-Finance N A | NA | NA | 121004 | L2 | Admitted-Finance | ||
| 3 | L3₹39.0 L+₹17,568.04 (0.45%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹53.6 L+₹14.8 L (38.2%)Admitted-Finance WZ 400 PALAM VILLAGE DELHI WEST DELHI SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Admitted-Finance | ||
| 5 | L5₹61.5 L+₹22.7 L (58.6%)Admitted-Finance HN12 GALI NO 4 KUSHAK NO 2 KADIPUR DELHI 36 | 36 | L5 | Admitted-Finance |
Tender Value
₹73.2 L
EMD Value
₹1.5 L
Closing Date
18 Feb 2026, 3:00 pmClosed
Er. CHANDER SINGH RAWAT
The Executive Engineer (E), West Electrical Division (M-131N), PWD, 41 Rama Road, Zakhira New Delhi-15, Telephone No. 25459518, e-mail ID [email protected]
A/R and M/O to Sub-Registrar Nangloi, SDM Office Punjabi Bagh, Sub-Registrar Basaidara Pur and Sub- Registrar Janak Puri
2026_PWD_286590_1
78/EE(E)/West Elect Div(M-131N)/PWD/2025-26
Open Tender
Electrical Works
Works
365 days
Work
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹1.5 L
20 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
Sub-Registrar, Nangloi Day to day Maintenance of all electrical installation with fixtures , Circuit, Submain, Distribution boards, Main boards, Security lights, and DG Set by deputing technical staff on monthly basis in General shift and as per Terms and Conditions attached:-
Wireman cum operator- 1 No.
Khallasi - 1 No.
Operation & Running maintenance of air cooled package type A.C unit/ VRV / VRF i/c cleaning, servicing, watch & ward of all equipment/safety of equipment at SR office excluding Sundays & Holidays as per terms & condition attached for one month.
(a) Operator cum AC Mechanic - 1 No.
Comprehensive Annual Maintenance contract of 200 KVA DG Set including complete Service Intervals B Check –After Every 300 Hrs./ 6Months whichever comes earlier 2 Times in 1 Year( nothing extra shall be paid) and scope of work include 1. Routine Engine Services with parts and lubricants as and when required. 2.Engineer will visit every month for general check-ups to preventive maintenance of your DG Set. 3. Unlimited Break Down calls to rectify the faults. 4. Engine Wiring Repair or Replacement including 4ST Switches and Safeties. 5. Repairing of Self Starters and Charging Alternators as and when required. 6. Repairing and Descaling of Radiators as and when required. 7. Minor Repairs of alternators i.e. Terminal Bar, Thimbles, AVR, Diodes, Rectifiers as required 8. Stand By Parts will be provided in case of failure of any i.e Self Starter, Charging Alternator, AVR etc as required. Scope not Covered in CAMC 1. If any Parts required to be replaced/repaired in case of shifting of DG Set will be charged extra as per site requirement. 2. Acoustic Enclosure / Canopy. 3. Major Overhauling if required carried out by us. 4. Top Overhauling if required carried out by us. 5. Cable From Alternator to Changeover switch. 6. Replacement of Alternator (if required) 7. Exhaust Room, Ventilation Fan & Motor, Acoustic Enclosures (shifting, painting, canopy lining, lock replacement, statutory requirements)fittings, repairs, shifting,& installing the engine or DG Set, all kind of civil and carpentry work, arranging stabilized power at site 8. Any liabilities due to accidents, mischief, strike, natural clematis-flood, fire, earthquake etc.
Comprehensive Annual Maintenance contract of VRF plant of 16hp x 9 nos.= 144 hp. Comprehensive maintenance inlcludes inspecting the plant/system & carry out preventive maintenance atleast four time a year, checking the refrigeration system, motor & starter & ensuring healthy conditon of the plant, checking the system for any leakages & rectification of leakages, taking set of readings and evaluating to ensure satisfactory performane of the plant, checking the refrigeration control system for operation and adjusting the settings, checking the functioning of compressors and its accessories, cleaning the IDU evaporator/ODU condenser coils once a year, lubricating the bearings of motors, & fans when found necessary, quarterly inspection of belts adjusting the tension and replacing the worn out belts as and when found required, replenishment of refrigerant gas as a result of wear and tear, overhauling the components of the equipment at site or in service station as and when required including providing loan compressor in case of failure of these compressors, checking of the microprocessor/PCBs and sensors of IDU/ODU units for its proper functioning and repair/replacement of the same if found necessary, attending to complaint/breakdown calls whenever required, reporting the healthiness of the plant.
SDM Office Punjabi Bagh Day to day Maintenance of all electrical installation with fixtures, Circuit, Submain, Distribution boards, Main boards, Security lights, and DG Set by deputing technical staff on monthly basis in General shift and as per Terms and Conditions attached:-
Wireman cum operator- 1 No.
Khallasi - 1 No.
Attending day to day complaints & Routine Maintenance of WTAC, Split A.C. of different capacity installed at various sites including overhauling/servicing of machine attending complaints i/c checking & cleaning of condenser coil etc of with suitable chemical & all necessary preventive maintenance as and when reqd. by providing experienced & qualified staff as per terms and condition attache, site requirement & as per the direction of Engineer-in-Charge.
For Summer Season. AC Mechanic - 01No.
For Summer Season. Khallasi - 01 No.
Comprehensive Annual Maintenance contract of 160 KVA DG Set including complete Service Intervals B Check –After Every 300 Hrs./ 6Months whichever comes earlier 2 Times in 1 Year( nothing extra shall be paid) and scope of work include 1. Routine Engine Services with parts and lubricants as and when required. 2.Engineer will visit every month for general check-ups to preventive maintenance of your DG Set. 3. Unlimited Break Down calls to rectify the faults. 4. Engine Wiring Repair or Replacement including 4ST Switches and Safeties. 5. Repairing of Self Starters and Charging Alternators as and when required. 6. Repairing and Descaling of Radiators as and when required. 7. Minor Repairs of alternators i.e. Terminal Bar, Thimbles, AVR, Diodes, Rectifiers as required 8. Stand By Parts will be provided in case of failure of any i.e Self Starter, Charging Alternator, AVR etc as required. Scope not Covered in CAMC 1. If any Parts required to be replaced/repaired in case of shifting of DG Set will be charged extra as per site requirement. 2. Acoustic Enclosure / Canopy. 3. Major Overhauling if required carried out by us. 4. Top Overhauling if required carried out by us. 5. Cable From Alternator to Changeover switch. 6. Replacement of Alternator (if required) 7. Exhaust Room, Ventilation Fan & Motor, Acoustic Enclosures (shifting, painting, canopy lining, lock replacement, statutory requirements)fittings, repairs, shifting,& installing the engine or DG Set, all kind of civil and carpentry work, arranging stabilized power at site 8. Any liabilities due to accidents, mischief, strike, natural clematis-flood, fire, earthquake etc.
Sub-Registrar Basaidara Pur Day to day Maintenance of all electrical installation with fixtures, Circuit, Submain, Distribution boards, Main boards, Security lights, and DG Set by deputing technical staff on monthly basis in General shift and as per Terms and Conditions attached:- Staff Details:-
Wireman cum operator- 1 No.
Khallasi - 1 No.
Comprehensive Annual Maintenance contract of 200 KVA DG Set including complete Service Intervals B Check –After Every 300 Hrs./ 6Months whichever comes earlier 2 Times in 1 Year( nothing extra shall be paid) and scope of work include 1. Routine Engine Services with parts and lubricants as and when required. 2.Engineer will visit every month for general check-ups to preventive maintenance of your DG Set. 3. Unlimited Break Down calls to rectify the faults. 4. Engine Wiring Repair or Replacement including 4ST Switches and Safeties. 5. Repairing of Self Starters and Charging Alternators as and when required. 6. Repairing and Descaling of Radiators as and when required. 7. Minor Repairs of alternators i.e. Terminal Bar, Thimbles, AVR, Diodes, Rectifiers as required 8. Stand By Parts will be provided in case of failure of any i.e Self Starter, Charging Alternator, AVR etc as required. Scope not Covered in CAMC 1. If any Parts required to be replaced/repaired in case of shifting of DG Set will be charged extra as per site requirement. 2. Acoustic Enclosure / Canopy. 3. Major Overhauling if required carried out by us. 4. Top Overhauling if required carried out by us. 5. Cable From Alternator to Changeover switch. 6. Replacement of Alternator (if required) 7. Exhaust Room, Ventilation Fan & Motor, Acoustic Enclosures (shifting, painting, canopy lining, lock replacement, statutory requirements)fittings, repairs, shifting,& installing the engine or DG Set, all kind of civil and carpentry work, arranging stabilized power at site 8. Any liabilities due to accidents, mischief, strike, natural clematis-flood, fire, earthquake etc.
Sub-Registrar Janak Puri Day to day Maintenance of all electrical installation with fixtures, Circuit, Submain, Distribution boards, Main boards, Security lights, and DG Set by deputing technical staff on monthly basis in General shift and as per Terms and Conditions attached:- Staff Details:- Wireman cum operator- 1 No. Khallasi - 1 No.
Wireman cum operator- 1 No.
Khallasi - 1 No.
Comprehensive Annual Maintenance contract of 82.5 KVA DG Set including complete Service Intervals B Check –After Every 300 Hrs./ 6Months whichever comes earlier 2 Times in 1 Year( nothing extra shall be paid) and scope of work include 1. Routine Engine Services with parts and lubricants as and when required. 2.Engineer will visit every month for general check-ups to preventive maintenance of your DG Set. 3. Unlimited Break Down calls to rectify the faults. 4. Engine Wiring Repair or Replacement including 4ST Switches and Safeties. 5. Repairing of Self Starters and Charging Alternators as and when required. 6. Repairing and Descaling of Radiators as and when required. 7. Minor Repairs of alternators i.e. Terminal Bar, Thimbles, AVR, Diodes, Rectifiers as required 8. Stand By Parts will be provided in case of failure of any i.e Self Starter, Charging Alternator, AVR etc as required. Scope not Covered in CAMC 1. If any Parts required to be replaced/repaired in case of shifting of DG Set will be charged extra as per site requirement. 2. Acoustic Enclosure / Canopy. 3. Major Overhauling if required carried out by us. 4. Top Overhauling if required carried out by us. 5. Cable From Alternator to Changeover switch. 6. Replacement of Alternator (if required) 7. Exhaust Room, Ventilation Fan & Motor, Acoustic Enclosures (shifting, painting, canopy lining, lock replacement, statutory requirements)fittings, repairs, shifting,& installing the engine or DG Set, all kind of civil and carpentry work, arranging stabilized power at site 8. Any liabilities due to accidents, mischief, strike, natural clematis-flood, fire, earthquake etc.
Supply of the following electrical accessories for day-to-day maintenance in the existing electrical installation or for stocking in the JE store, as and when directed by the Assistant Engineer / Junior Engineer.
1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
S.P. 5/6 A, one way modular switch, ISI marked
S.P. 15/16 A, one way modular switch, ISI marked
3 pin 5/6 A modular socket outlet, ISI marked
6 pin 15/16 A modular socket outlet, ISI marked
6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity
6 A to 32 A ratings, SPN MCB, “C” curve, 10 kA breaking capacity
3 pole MCCB, 400A, 35kA
3 pole MCCB, 250A, 25kA
Stepped type Modular Fan regulator (2 module)
3x10 Sq.mm XLPE insulated, PVC sheathed, Aluminium armoured cable
36 Wat LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) with 5 years OEM warranty complete etc as required.
100 Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials.with 5 years OEM warranty complete etc as required.
metalic Exhaust Fan 300 mm Sweep 900 RPM
400 mm Hi-Speed heavy duty wall fan suitable for operation on 230 Volts + 10%, 50Hz Single Phase A.C. Supply
12-15 W LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector with 5 years OEM warranty complete etc as required.
40 watt LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) with 5 years OEM warranty complete etc as required.
1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) with 3 years OEM warranty complete etc as required.
72W LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. with 5 years OEM warranty complete etc as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and charging refrigerant gas (i.e. R-410) in the existing VRV/PTAC plant unit complete with leak detection, vacuumising & rectification the leakage, pressure testing i/c brazing, providing necessary copper piping & insulation, providing suitable capacity liquid line drier etc. testing, commissioing complete as required.
Servicing and complete overhauling of WTAC/Split units after dismantling from various locations, removing of dust from condenser coil, cooling coil and chasis wherever required complete cleaning of fin condenser coil with cleaning agent of superior quality, dismantling of blower motor (if required), washing etc after dismantling of condenser motor replacement of defective parts finally applying two coats of black synthetic paint of approved brand before fixing new 5 mm./6 mm. foam sheet with adhesive testing commissioning etc. complete as reqd.
WTAC/STAC
Supplying and charging of R-22/R-134 or any other refrigerant gas as per requirement in 1.5/ 2TR capacity WTAC/Split AC unit i/c necessary copper pipe, capllary & fiter i/c brazing the tube leakage, finding, pressure testing and vacummuizzing complete as required.
1.5/2 TR WTAC/Split AC
Replacement of defective compressor with of 1.5/2TR capacity in existing AC including connection with suitable size of suction & discharge copper pipe, copper stainer, capillary, nut bolts, connections, interconnections of the elecctrical wiring with suitable cables, checking of leakage, pressure testing with nitrogen gas for 24hours, vacumising, etc as required i/c buy back credit of defective item.
Supplying & transporting of the High Speed diesel from authorized dealer and filing into DG sets at site or storing into drums as per requirement or instruction by enginring incharge.
Supply & fixing of 6 kg ABC type Fire Extinguisher Stored pressure type wall mounted duly ISI marked conforming to IS:14609 ISI complete with squeeze grip release valve, locking arrangement, pressure gauge, discharged pipe and operation manual etc complete as required.
Supply & fixing of 4.5 kg CO2 type Fire Extinguisher Stored pressure type wall mounted duly ISI marked conforming to IS:15683 ISI complete with squeeze grip release valve, locking arrangement, pressure gauge, discharged pipe and operation manual etc complete as required.
Fabricating, Supplying, Installation, Testing and Commissioing of floor mounted cubical panel board powder coated with 7 tank process minimum 400mm deep made out of 2mm thick CRCA Sheet, mounting on angle iron frame work of size 50mm x 50mm x 6mm thick dust and vermin proof, duly compact with suitable i/c 4 strip aluminium busbar capacity of suitable bus bar size as per incomer duly power coated paint of approved colour and shade providing earth stud at both end, louvers and mesh on both side of panel board for ventilation purpose i/c connection and interconnection, earthing complete etc as reqd. (Drawing of panel shall be got approved from the Deptt. before fabricating after award of work).
Supplying & fixing of following accessories in above panel complete etc. as required
Digital Voltmeter
Digital Ampere meter
LED indicating Lamp
RYB swicth with base.
63A TPN MCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A, 16 KA,TPMCCB
125 A, 16 KA,TPMCCB
200 A, 25 KA,TPMCCB
250 A, 25 KA,TPMCCB
400 A, 35 KA,TPMCCB
Supply, installation, testing, and commissioning of 200 kVA AMF Panel automatic system that starts the generator during mains failure and transfers the load seamlessly. It ensures reliable power continuity with a microprocessor controller, protection devices, and safe changeover back to mains when restored etc. as required.
Supply, installation, testing and commissioning of water cooler FSS 150/150 Ltr. tank capacity, stainless steel body, energy efficient compressor with eco friendly refrigerant suitable for operation on 230 volts ±10%.
Supply, Installation, Testing & Commissioning of 100 LPH RO System of a fully automatic 100 LPH Reverse Osmosis (RO) Water Purification System with high-quality RO membrane Pre-filtration units (sediment & carbon filters) High-pressure pump and booster pump Pressure gauges, flow meters, control valves, and piping Electrical control panel with necessary safety features Checking system pressure, flow rate, and TDS levels Inspection of all joints, fittings, and electrical components Performance testing under full load conditions as per site requirement.
credit to the Contractor on as-is-where-is basis, including dismantling, collection, loading, unloading, transportation, and all incidental charges, complete as directed by the Engineer-in-Charge.
Assorted 1.5/4.0/3x10 Cable
Assorted MCBs/MCCBs
5/6, 15/16 A Switch Sockets
30- 45W 2X2 LED Light
100W Flood Light/ Street Light
40W LED Batten
18W Downlighter
1200mm Ceiling Fan
Assorted Panel
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
BOQ_379416.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .