| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 CrAdmitted-Finance | ₹39.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹40.8 CrAdmitted-Finance | ₹40.8 Cr | L2 | Admitted-Finance |
| 3 | L3₹42.8 CrAdmitted-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | ₹42.8 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Renjin Construction L3 | KALPANA STRUCT CON PVT LTD L1 | ANS Constructions.com L2 |
|---|---|---|---|---|---|---|
| 1.00GENERAL ABSTRACT | ||||||
| 2.00 | PART - I - Civil Works | 1 | Nos | 11,84,21,635 ₹11.8 Cr | 10,79,72,098 ₹10.8 Cr | 11,07,46,580 ₹11.1 Cr |
| 3.00 | PART - II - Public Health Engineering works | 1 | Nos | 64,71,370 ₹64.7 L | 53,46,993 ₹53.5 L | 55,82,450 ₹55.8 L |
| 4.00 | PART - III - Electrical works | 1 | Nos | 1,59,55,600 ₹1.6 Cr | 1,58,46,220 ₹1.6 Cr | 1,83,78,616 ₹1.8 Cr |
| 5.00 | PART - V - Firefighting works | 1 | Nos | 16,96,250 ₹17.0 L | 12,43,036.5 ₹12.4 L | 12,15,767 ₹12.2 L |
Tender Value
₹13.8 Cr
EMD Value
₹23.8 L
Closing Date
6 Jun 2022, 5:00 pmClosed
Chief Engineer (C1)
DCSEM, DAE, 3rd floor, V.S. Bhavan, Anushaktinagar, Mumbai-94
Construction of New Creche facility building near Badrinath Building including Civil, PH, Electrical and Fire Fighting works in Western part of Anushaktinagar, Mumbai.
2022_DCSEM_688104_1
DCSEM/CQD/QSA/ New Creche Facility /22-23/NIT/07
Open Tender
Civil Works - Buildings
450 days
Anushaktinagar, Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹23.8 L
9 Sept 2022
11 May 2022
9 Jun 2022
11 May 2022
6 Jun 2022
27 May 2022
12 May 2022 - 23 May 2022
Amount
GENERAL ABSTRACT
PART - I - Civil Works
PART - II - Public Health Engineering works
PART - III - Electrical works
PART - V - Firefighting works
Description of Work / Item(s)
Amount
ABSTRACT FOR PART - I
PART - I - CIVIL WORKS
PART-I-A-Sub Structure
PART-I-B-Super Structure (Structural)
PART-I-C-Form Work
PART-I-D-Steel Reinforcement work
PART-I-E-Masonry work
PART-I-F-Flooring work
PART-I-G-Doors and windows
PART-I-H-Fittings and fixtures
PART-I-I-Waterproofing treatment
PART-I-J-Plastering work
PART-I-K-Painting work
PART-I-L-Miscellaneous work
Description of Work / Item(s)
Amount
Part I : CIVIL WORKS
Part I -A : SUB STRUCTURE
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal ofrubbish up to a distance of 50 m outside the periphery of the area cleared.
Depth not exceeding 1.5 m from ground level
Depth exceeding 1.5 m & up to 3.0m from ground level
Depth exceeding 3.0 m & up to 4.5m from ground level
Depth not exceeding 1.5 m from ground level
Depth exceeding 1.5 m & up to 3 m from ground level
Depth exceeding 3.0 m & up to 4.5m from ground level
Depth not exceeding 1.5 m from ground level
Depth exceeding 1.5 m & up to 3 m from ground level
Depth exceeding 3.0 m & up to 4.5m from ground level
Cement concrete of specified grades at all locations & depths for the following works usinggraded stone aggregate of 20mm maximum size including necessary form work, machinemixing, transporting, placing in position consolidation, finishing, curing etc. complete as perspecifications, drawings & as directed by the Engineer-in-Charge. Notes: a) Reinforcement provided if any shall be measured & paid under relevant item. b) MS frame works around pedestals etc. if provided shall be measured under relevant item. c) The dimensions of pedestals/ foundations are likely to be varied and rate quoted shall be final without any additional cost to the Department.
P C C M-10 grade in bed concrete to foundations,pedestal,Cable,trenches etc.
P C C M-15 grade in Plinth protections, Sub-base Flooring, foundation in pedestals, cable pits, cable trenches, plinth protection, encasing etc.
Reinforced Cement Concrete of grade M-30 in foundation and plinth at all levels and locations conformining to I.S. 456-2000 and 13920 latest edition, using 20mm. maximum sizedown graded stone aggregate including machine mixing, conveying, placing in position,mechanical consolidation, finishing, curing etc. all complete as per specifications, drawingsand as directed by the Engineer-in-charge, for the following. Notes for Reinforced Cement Concrete works: i) Cement for structural works shall be OPC/PPC ISI marked and duly approved by the Engineer-in-charge. ii) PPC/ blended cement of ISI marked shall only be used for finishing works on prior approval of Engineer-in-charge. iii) All RCC work shall be controlled concrete unless otherwise specified and shall be carried out strictly in accordance with the drawings and specifications. iv) The rates for RCC works shall be exclusive of cost of reinforcement and form work unless otherwise mentioned. v) All coarse aggregate to be of 20mm. maximum size & uniformly graded unless otherwise mentioned. vi) The water tank and other tanks shall be executed strictly as per following criteria without any additional cost. a) The water tank and other tank work shall be executed as per IS 3370 latest editions in addition to other relevant IS code mentioned elsewhere. b) The minimum cement content for water retaining structures tank shall not be less than 330 kg/cum and not more than 400 kg/cum. c) During construction of raft slab of underground tank, lift pit dewatering shall be continuously carried out to avoid developent of water pressure. d) Dead load in the form of sand bag shall be placed on the raft slab of underground tank, lift pit, so as to counteract the pore pressure untill the walls are constructed and back filling is done. Number of sand bags required and time period of loading etc. shall be at the descretion of the Engineer in Charge. vii) For all RCC items, the rates quoted shall include the following without any extra cost to the Department. a) Spacers to maintain clear cover for reinforcement. b) Fixing at correct level and in proper alignment the inserts, pipe sleeves, pipe bends, hooks, other pipe specials etc. supplied by/ through the dept. c) Making cutout whereever required including cutting the form works etc. d) Test for Concrete shall be done as per IS 456-2000 and the cost of the same shall be borne by the contractor.
For all type of Structural / RCC elements with all geometrical shape and sizes.
Extra for providing RMC (Ready Mixed Concrete) confirming to IS :4926 (latest) in lieu of conventional RCC and PCC items supplied by approved RMC manufactures for all type ofstructural elements/RCC/PCC elements including transporting,pumping etc. complete as perinstruction of the Engineer-in-charge. Notes: i) The contractor shall obtain prior approval for RMC manufacturer from Engineer-in-Charge in writing. ii) The rate shall apply for all levels and locations including all type of structure etc. iii) Extra for RMC in lieu of conventional RCC and PCC of any grade mentioned else where shall be measured and paid under this item for substructure works.
Providing, erecting, fixing in position striking / removing,cleaning steel / timber shuttering & centering for form work in foundation plinth at all locations for all geometrical shapes in plain,curved surfaces of structural / RCC elements including chamfers, splays, keys, wedges,props, rails, bracings, brackets, cutting holes for pipes etc., providing & applying approvedform oil on all surfaces of form work coming in contact with concrete including close hackingof all exposed concrete work after removal of form work, where plastering to be done,including all materials, labour etc. all complete as per specifications, drawings and asdirected by the Engineer-in-charge. Notes for Formwork: i) Area of form work in contact with concrete shall only be measured for payment and stop boards for construction joints will not be measured for payment. ii) The rate of formwork shall include all type of structural / RCC elements and geometrical shapes including circular and any other curved surfaces. iii) For double/ multi stage shuttering design calculations and details /drawings for scaffolding shall besubmitted by the contractor well inadvance. Prior written approval of formwork shall be obtained from Engineerin Charge, before commencement of work. iv) Nothing extra shall be entertained for revision in drawings.
Reinforcement for RCC work including supplying, delivering, storing of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening,cutting, bending, placing in position at all locations & levels and binding with 18 gauge, softdrawn annealed steel binding wire including carrying out various tests as required etc. all asper specifications, drawings & as directed by the Engineer-in-Charge. Note: The cost of binding wire shall be borne by the contractor and binding wire shall not be measured for payment.
Thermo Mechanically Treated bars of grade Fe-500 D manufactured by SAIL, TATA STEEL, JSW ,RINL and JSPL only.
Brick masonry work in foundation, plinth, cable pits, trench, steps etc. using well burnt bricks from approved lot of class designation 3.5 (classification as per IS 1077-1992 and min.average compression strength not less than 3.50 N/mm2 ) in ready mix cement mortar 1: 6 tocorrect line, level and plumb including raking out joints/simultaneous flush pointing withReady Mix Mortar 1:4, curing etc.complete as per specifications, drawings and as directedby Engineer-in-charge. Note for Brick masonry work: i)One brick wall thickness shall be considered as 230 mm & lesser wall thickness if any shall be made up to the required dimension by the contractor by applying Ready Mix Mortar 1:4 inproper line, level & plumb without any extra cost to the department. ii) The rate shall include cost of making the brick masonry to all geometrical shapes and sizes without any extra cost to the Department. iii)The contractor shall get approved the samples of bricks from the Engineer-In- Charge before procurement on large scale and shall maintain the same for the entire work. iv) Necessary Openings/ nitches/ cut-outs, wherever required as per drawings and asked for by the Engineer-In-Charge, shall be provided by the contractor without any extra cost.
Providing 20mm thick cement plaster 1:4, using Ready mix mortar, finished smooth, for concrete/masonry surfaces (inside trench/nalla/pit / storm water drains etc.), mixed with water proofing agent @ 2% by weight of cement or as per manufacturer's specifications, complete as instructed by Engineer in charge.
Disposing off the surplus excavated materials by mechanical transport to the nearest approved disposal ground of MCGM or area inside Anushaktinagar including all leads, lifts, loading, unloading, stacking, spreading, levelling etc. complete all as per guidelines of construction and demolition waste management plan as approved by MCGM and as directed by the Engineer in charge. Note: i)Voids @ 20% for soils and 50% for soft rock/ hard rock shall be deducted from fully loaded truck measurements to arrive at the net quantity for payment in case direct measurement is not possible. ii) Royalty for transportation, disposal of earth, spreading etc. including obtaining permission from statutory authority, if any shall be borne by the contractor.
230mm consolidated thickness.
150mm consolidated thickness.
Supplying and spreading pesticides chlorpyriphos or other chemical approved by central insecticides board as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-construction anti-termite treatment at the rate of 7.5 liters per sq.m. on vertical and 5 ltrs. per sq.m. on horizontal surfaces (or as directed by the manufacturer) within the trenches, 50% of the emulsion to be filled in the holes made in trenches at 150mm. centre to centre etc. complete as per IS 6313 Part-II. (The payment will be made on the basis of plinth area measurement only at ground floor/ stilt area for all stages of operation and vertical face will not be measured for payment) all complete as per specifications, drawings and as directed by the Engineer in charge. Note: a) This item will be executed through approved agency who is a member of Indian Pest Control Association, approved by Central Insecticides Board. b) The contractor shall have to furnish ten years guarantee in the prescribed proforma as per Section-10 (iv) Conditions and clauses of contract-2008, to maintain the anti-termite treated area/ structure free from termite. c) Prior approval of Engineer in Charge shall be obtained after testing the chemical for antitermite to be used and shall be tested in approved laboratory and to be submitted to Engineer in Charge. Cost of testing shall be included in the rates quoted.
Providing and laying damp proof course 38mm thick at plinth level in cement concrete 1:2:4 using 10mm. maximum size and down graded stone aggregate, mixed with approved water proofing compound at 2% by weight of cement laid to levels, slopes etc. including applying a coat of hot bitumen of grade 80/100 at 17 kg./10 sq.m. including cost of form work, curing all complete as per specifications & as directed by the Engineer in charge.
Structural steel work in frames, covers, using angles, tees, flats, bars, chequered plates, inserts fabricated out of mild steel bars, ISMC, ISMB, angles, pipes, plates etc. of all shapes, sizes including supplying, cutting, fabricating, welding, erecting, making holes/ chases wherever required and fixing / embedding in position in concrete/ brick work with necessary hold fasts/ screws & rawl plugs and finishing the concrete/ brick work after fixing/ embedding including painting two coats of anticorrosive bitumastic paint on all unexposed surfaces and two coats of synthetic enamel paint of approved make and colour on all exposed surfaces over a coat of approved steel primer etc. complete as per specifications, drawings and as directed by the Engineer in charge.
Providing & laying NP 2 class of following diameter RCC hume pipe including making holes in masonry/ concrete work wherever required, making good the holes after laying the hume pipe with collar joints using stiff mixture of cement mortar (1:2) and sealing open ends with wooden bush etc. all complete as per specifications & as directed by the Engineer-in-charge. (Earthwork, road work and PCC for embedment shall be paid under relevant items)
250 mm dia pipes
TOTAL OF PART I - A : (Sub Structure)
PART I-B : SUPER-STRUCTURE (STRUCTURAL) i) Super structure items included in this schedule pertains to all the works above plinth level upto roof including parapets, water tanks, machine room, terrace level works etc. unless specified otherwise.
Reinforced cement concrete of grade M-30 in super structure conforming to IS 456-2000 and 13920 latest edition, at all floors and levels for all structural members in all geometrical shapes/ design as per drawings using graded stone aggregate of 20mm and down graded including machine mixing, conveying, placing in position, mechanical consolidation, finishing, curing, etc. complete all as per drawings, specifications & as directed by Engineer in Charge. Notes for RCC Works: a) All RCC works shall be controlled concrete unless otherwise specified and shall be carried out strictly in accordance with the drawings, specifications and as directed by the Engineer in Charge. b) The water tank work shall be as per IS 3370-2009 latest edition c) The rates for RCC works shall be exclusive of cost of reinforcement and form work unless otherwise mentioned. d) All coarse aggregate to be 20mm maximum size and uniformly graded unless otherwise mentioned. e) For all RCC items, the rates quoted shall include the following without any extra cost to the Dept. i) Spacers to maintain clear cover for reinforcement. ii) Fixing at correct level and in proper alignment the inserts, pipe sleeves, pipe bends, fan hooks, other pipe specials etc. supplied by/ through the Department. iii) Cut out in slabs, construction joints etc. f) Test for concrete shall be done as per IS 456-2000 and the cost of the same shall be borne by the contractor.
For all type of Structural/ RCC Elements with all geometrical shape
Extra for providing RMC (Ready Mixed Concrete) conforming to IS 4926 (Latest) in lieu of conventional RCC items, supplied by approved RMC manufacturers including transportation,pumping etc ,complete as per instruction of Engineer-in-Charge. Notes: i) The contractor shall obtain prior approval for RMC manufacturer from Engineer in Charge in writing. ii) The rate shall apply for all levels and locations including all type of structure etc. iii) Extra for RMC in lieu of conventional RCC of any grade mentioned elsewhere in the schedule shall be measured and paid under this item for superstructure works.
Extra for adding approved integral crystalline waterproofing admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete or as recommended as per manufacturer's specification including mixing, conveying, etc. complete and as directed by Engineer in charge. (For terrace roof slab, sloped roof, head room, etc.) Note: The agency shall have to test for water tightness of roof slab concrete by ponding of water for 48 hours and rectify if required by grouting etc, as directed by Engineer in charge.
TOTAL OF PART I - B : Super Structure (Structural)
Part- I - C - Form Work Notes for form work i) For double/ multi stage shuttering design calculations and details /drawings for scaffolding shall be submitted by the contractor well in advance. Prior written approval of form work shall be obtained from Engineer in Charge, before commencement of work. ii) Area of form work in contact with concrete shall only be measured for payment and stop boards for construction joints will not be measured for payment. iii) The rate of formwork shall include all type of structural/ RCC elements and all geometric shapes including circular and any other curved surfaces at all level and floors including single/ multiple staging etc., complete.
Providing, erecting, fixing in position, striking / removing and cleaning steel / timber shuttering & centering for form work including single /multiple staging at all floors, level & locations for all geometrical shapes in plain, curved surfaces of structural / R C C elements and including rails, bracings, props, brackets, cutting holes for pipes etc., providing & applying approved form oil on all surfaces of form work coming in contact with concrete including close hacking of all exposed concrete work after removal of form work, all materials, labour etc. complete as per specifications, drawings & as directed by the Engineer-in-Charge. (Area of form work in contact with concrete shall only be measured for payment & stop boards for construction joints etc. will not be measured for payment).
For all type of structural / RCC elements including all geometrical shapes and single / multiple staging at all floors and location.
Providing, erecting, fixing, in position, striking / removing and cleaning steel / timber Shuttering & centering, for formwork using ply board to obtain form finished concrete surfaces of F3 finish to ceilings at all floors, heights & locations including single / multiple staging at all floors and locations for all geometrical shapes in plane, curved surfaces of structural / R C C elements including chamfers, splays, keys, wedges, props, rails,bracings, brackets, cutting hole for pipes etc. providing and applying approved form oil to all surfaces of form work coming in contact with concrete and skirting / removal of the same including finishing by filling form-tie-holes, removal of fins, ridges and irregularities by grinding filling air holes, with sack rubbed finish, cleaning up loose and adhering debris including all materials labour etc. Complete as per specifications, drawings and directed by Engineer-in-Charge.
Total of Part- I - C - Form Work
PART - I-D : STEEL REINFORCEMENT WORK
Reinforcement for RCC work including supplying steel bars of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening,cutting,bending placing in position and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications,drawings & as directed by the Engineer-in-Charge. (Cost of binding wire shall be borne by the contractor & shall not be measured for payment).
Thermo Mechanically Treated bars of grade Fe-500 D manufactured by SAIL, TATA STEEL, JSW , RINL and JSPL only.
Total of Part- I - D - STEEL REINFORCEMENT WORK
PART - I-E : MASONRY WORK Notes: a) The contractor shall get approved the samples of autoclaved aerated cement blocks from the Engineer-In-Charge before procurement on large scale and shall maintain the same for the entire work. b) Necessary Openings/ nitches/ pipe sleeves/ cut-outs, wherever required as per drawings and asked for by the Engineer-In-Charge, shall be provided by the contractor without any extra cost. c) Masonry wall thickness shall be considered as 230mm/ 150mm/ 115mm thick and lesser wall thickness if any shall be made up to the required dimensions by the contractor in CM 1:4 using Ready Mix Mortar to proper line, level and plumb without any extra cost to the Department. d) The rate shall include cost of making autoclaved aerated cement blocks masonry to all geometrical shapes and sizes without any extra cost to the Department.
Providing and laying autoclaved aerated cement blocks masonry with 115mm/ 150mm/ 230mm thick AAC blocks as per approved manufacturer, using approved block laying polymer modified adhesive mortar in super structure above plinth level at all locations, levels & lead with RCC band at sill level and lintel level all complete as per direction of Engineer in-Charge. (The payment of RCC band and reinforcement shall be made for separately).
Total of Part- I - E - MASONRY WORK
PART -I-F : FLOORING WORK Notes: a) Adjustment of levels in thickness of mortar bedding due to different types of flooring, if any, shall be done by the contractor without any extra cost to the Department upto theoritical floor thickness of 50mm b) In case theoritical floor thicknes is increased to accommodate Raceways/ Electrical service boxes, additional bedding material beyond floor thickness of 50mm shall be paid extra in lean concrete as approved by EIC. c) The contractor shall submit and get approved the sample for flooring, skirting, dado tiles from Engineer in charge before bulk procurement. d) Pattern & design of flooring/ skirting/ dado shall be approved by the Engineer in charge before commencement of work. e) All Exposed edges of all natural stones used for the works like Kotah, Marble, Granite etc. shall be machine cut and shall have uniform thickness, moulded/ champered and mirror polished with high gloss finish as approved by Engineer in charge unless otherwise mentioned. f) The rate shall include cost of making Designs/ patterns in the flooring to all geometrical shapes/ curves of different radius and sizes with no extra cost to the Department. (Any curved design/ patterns in flooring/ Dado, tiles/ stones shall be cut using water jet at facory) g) All Kota stone work shall be mirror polished to get high gloss finish and the rate shall be inclusive of the same in the respective item. h) Wherever dissimilar floor finishes are placed adjacent 3mm thick x 25mm wide aluminium flat dividing strips shall be provided by the contractor without any additional cost to the Department. i) The sizes of tiles mentioned are approximate and subject to the availability in market during execution. If the required size is not available the next higher size of tiles shall be used without any extra cost to the Department. The tenderer may note the same and quote accordingly. j) The contractor is to take appropriate step to protect the polishing surface/ glazed surfaces of granite stone, vitrified tiles, ceramic tiles flooring and pre polished kotah stone for tread and riser by providing and laying 6mm thick POP during construction period without any additional cost. The surfaces are to be cleaned only at the time of handing over.
Providing & laying at all floors & locations Glazed Vitrified tile double charge/ multi charge/ Ultra charge (Glossy/ Matt/ Satin finish) from approved manufacturers of sizes 600 x 600mm/ 800 x 800mm/ 1000 x 1000mm size conforming to IS 15622 in flooring/ skirting/ dado/ cladding at all floors and location, heights/ levels and lead in approved pattern and colour laid over Ready Mix Mortar bedding/ backing, including cleaning and preparing the surface for bedding, spreading the neat cement slurry, close jointed and grouted with matching coloured ready made cement grout and approved pigment as per manufacturer's specifications, finished to level, line, slope and plumb, cutting of tiles, wastage, making openings/ cut out if neccesary, final cleaning of surfaces, curing etc. all as per drawings, specifications & as directed by Engineer in charge.
Glazed Vitrified tile (GVT series) / stonex finish vitrified tiles in flooring of size 800mm x800mm to 1000x1000mm of approved colour & make, laid over 20mm thick Ready Mix Mortar 1:4 bedding as per pattern shown in drawing, spreading neat cement slurry by using minimum cement about 2kg/sqm prior to bedding, spreading cement paste using minimum cement of about 4.50kg/sqm over bedding, including providing 3 mm thick, 8mm deep groutline using PVC spacers for creating true alignment and gap between vitrified tile & the 3mmspacer joints filled with approved epoxy tile grout including providing and laying Dura floor protector XF 3mm thick sheet of M/s. Supreme industries/ equivalent over the whole vitrified tile cleaning the same before handing over without damaging the finished surface & making good if damaged, if any including edge beading wherever required such as along the edges of vitrified tile flooring at locations shown in the drawing. ( Note: In case the tiles of prescribed sizes are not available, alternate tiles of nearby dimensions of area 0.64 sqm to 1.0 sqm shall be used as approved by EIC without additional cost to department).
Vitrified tile flooring of size 600mm x 600mm Matt/sattin matt finish/stonex series laid over 20mm thick Ready Mix Mortar 1:4 bedding as per pattern shown in drawing, spreading neat cement slurry by using minimum cement about 2kg/sqm prior to bedding and spreading cement paste using minimum cement of about 4.50kg/sqm over bedding, including 3 mm thick and 8mm deep grout line using PVC spacers for creating true alignment and gap between vitrified tile & the 3mm spacer joints filled with approved epoxy tile grout including providing and laying Durafloor protector XF 3mm thick sheet of M/s. Supreme industries/equivalent over the whole vitrified tile cleaning the same before handing over without damaging the finished surface & making good if damaged, if any including edge beading wherever required such as along the edges of vitrified tile flooring at locations shown in the drawing.
Glazed Vitrified tile skirting of 100mm high cut from tiles of size 600mm x 600mm to1000x1000mm glossy/ Matt finish of approved colour, matching with respective flooring, fixed over 12mm thick cement mortar 1:4 using Ready Mix Mortar backing.
Providing & laying at all floors & locations Vitrified tile steps as approved for staircase of stair series for tread with premoulded self imposed antiskid grooves and for risers out of stair series of approved colour from approved manufacturers conforming to IS 15622, in staircase tread/ riser at all floors and location, heights/ levels and lead in approved pattern and colour laid over readymix cement mortar bedding/ backing, including cleaning and preparing the surface for bedding, spreading the neat cement slurry, close jointed and grouted with matching coloured ready made cement grout and approved pigment as per manufacturer's specifications, finished to level, line, slope and plumb, cutting of tiles, wastage, making openings/ cut out if neccesary, final cleaning of surfaces, curing etc. all as per drawings, specifications & as directed by Engineer in charge.
In treads(stair series) with premoulded self embossed antiskid grooves(300mm x1200mm or as approved) of approved colour, laid over 20mm. thick Ready Mix Mortar 1:4 bedding.
In Riser(stair series) laid over 12mm. thick Ready Mix Mortar 1:4 backing.
In slopped skirting laid over 12mm thick Ready Mix Mortar 1:4 backing.
Providing and laying water repellant ceramic tile of 6mm thick or as per specification of approved manufacturer and approved colour in Ready Mix Mortar backing, close jointed and grouted with matching cement slurry to match the colour of the tiles, finished to level, line, slope and plumb including cutting of tiles, making openings/ cutout if necessary, wastage and final cleaning of surfaces as required, curing etc. complete all as per drawings, specifications & as directed by Engineer in Charge. Note:- The sizes of tiles mentioned are approximate and subject to the availability in market during execution. If the required size is not available the next higher size of tiles shall be used without any extra cost to the Department. The tenderer may note the same and quote accordingly.
In dado/ clading of size 300mm x 600mm with approved design/ pattern tile laid over 12 mm thick Ready Mix Mortar backing of 1:4, PVC corner beading/ nosing of approved quality and colour at the corner and edges of the tiles including finishing and embedding in the wall etc. complete all as directed by the Engineer- in- charge.
In flooring with machine polished kotah stone slab of size 575mmx575mmx25mm thick laid over & including 20mm thick cement mortar 1:4 bedding using Ready Mix Mortar as per pattern shown in drawing.
In skirting with machine polished kotah stone slab of size 575x100x20 mm thick fixed using 12mm thick cement mortar 1:3 backing using Ready Mix Mortar.
Providing, laying and fixing in position at all floors and levels, machine cut, machine polished (mirror polish) Granite stone of approved colours minimum 18mm thick of approved quality and shade ( Asian Teak Granite/ Black Granite) for flooring/ skirting/ tread/ riser/Ramps/ Dado/ Facia etc. on brick/ concrete surface etc., with pre-polished granite stone ofrequired sizes, fixed over and including necessary mortar bedding/ backing coat, close jointed and grouted with matching cement slurry mixed with suitable pigments including fixingapproved stainless steel clamps / pins at suitable intervals and approved adhesive such asaraldite to ensure fixing of stone securely including making necessary recess in the granite stone to accommodate the hold for stainless steel clamps/ pins @ 600c/c on both directionsand using approved adhessive such as araldite to ensure the fixing of stone securedly,grouting the joints with approved pigments, curing, cleaning and final hand polishing etc.complete all as per specifications, drawings and as directed by Engineer-in-Charge. Note:- i)The tread and risers are to be polished at factory. The exact size are to be laid without any further polishing. ii) The grooves are to be cut at factory to maintain the gap uniform. Non uniform groove size and irregular gaps between grooves shall not be accepted and rejected forthwith. iii) Rate includes providing Mirror polished granite to full height of side walls as dado, cut from granite tiles as per pattern shown in drawings. iv) The contractor is to take appropriate step to protect the polishing surface of the floor,tread and riser by providing and laying 6mm thick POP during construction period. The surfaces are to be cleaned only at the time of handing over.
In flooring, with combination of Mirror polished and semi flamed Asian Teak granite of size 800mm x 800mm as per pattern (60% polished + 40 % semi flamed) as per specification, over 20 mm thick cement mortar 1:4 bedding using Ready Mix Mortar, including cement slurry at 4.40 kg/sqm over bedding and matching slurry with white cement at 2.20 kg/sqm for grouting the joints.
In skirting, Dado, facia, slopped skirting, top of side wall/toe wall, etc. with mirror polished Asian Teak Granite/Black granite stone laid over 12mm thick cement mortar 1:3 using Ready Mix Mortar including rounding in semicircle / champhering the edges etc.complete.
In treads with mirror polished approved quality Asian Teak granite stone in single piece upto 1500mm (approx), laid over 20mm thick cement mortar 1:4 using Ready Mix Mortar including rounding in semicircle(half round nosing) / champhering the exposed edges including providing three nos of antiskid grooves 5mm wide & 2mm deep and mirror polishing etc. complete and as directed by the Engineer-in-Charge.
In risers with mirror polished 18mm thick Black Granite stone in single piece upto 1500mm laid over and including 12mm thick cement mortar 1:3 backing using Ready Mix Mortar.
In ramps with mirror polished 18mm thick Asian Teak granite stone, flamed finished in single piece strips and in border, of approx. size 1500mm x 150mm laid inclined over 20 mm thick cement mortar 1:3 bedding using Ready Mix Mortar with exposed edges nosed/ chamfered.
30 mm thick machine cut and both side machine polished Cuddaph stone for shelves including rubbing and polishing the exposed edges.
25 mm thick machine cut and one side machine polished Kota stone flooring including rubbing and polishing the exposed edges, fixed over 20mm thick ready mix CM 1:4 bedding.
Providing & laying machine cut machine polished natural stones as mentioned below for kitchen platform/ wash basin counter topping, vertical and Horizontal facia over and including necessary ready mix cement mortar for backing/ bedding, close jointed and grouted with matching cement slurry and finished to line, slope, level, plumb, curing etc. as required including cutting of stone slabs, wastages, making cut outs wherever required etc. all as per specifications and as directed by the Engineer in charge. Note : 1)Top exposed surface on plan & exposed vertical finished face shall be measured for payment in sqm.
For kitchen platform / wash basin counter top, upto 650mm wide and upto 2000 mm long in single piece in combination, consisting of machine cut machine polished on one side minimum 30 mm thick cuddappa stone at bottom and mirror polished machine cut 18 mm thick Jet black Granite stone at top fixed with 52 mm thick 1:4 ready mix cement mortar, between two stone slabs (Double stone slab sandwitch type) including providing cut out if any to fix Sink/ wash basin, including necessary cement paste, moulding and polishing the edges, providing required slope to drain away water, etc. complete.
For facia, in kitchen platform facia / wash basin counter facia upto 100 mm wide / 300 high vertical sides / or any other size as shown in the drawing, machine cut machine polished, on one side 18mm thick jet black Granite stone fixed with epoxy resin based adhessive (Araldite or equivalent), with clamp/ pins as per requirement, including round moulding and polishing the edges etc. complete.
For horizontal beading of size 40mm to 60mm wide * 18mm thick, On top of kitchen platform/ wash basin counter, with machine cut machine polished Jet black Granite stone fixed withe poxy resin base (Araldite adhesive or equivalent) including round moulding/pencil edge finish and polishing the edges, filling the gaps with adhessive etc. complete.
Providing & laying machine cut machine polished Cuddapah stones/granite stone in two pieces (sandwitch type) as mentioned below for kitchen platform vertical support/ wash basin Counter supports, including necessary cement mortar for backing/ bedding, close jointed and grouted with matching cement slurry and finished to line, slope, level, plumb, curing etc, as required including cutting of stone slabs, wastage, making cut outs wherever required etc. all as per drawings, specifications and as directed by EIC. Note : 1)Verticals,shelves,platform shall be embedded minimum 25 mm in brick/block / flooring. 2)Exposed finished surface only, shall be measured for payment. 3) The two stones errected for each vertical support shall be measured as a single unit under this item.
For vertical support of wash basin Counter/kitchen platform/shelves/Bag racks etc.,consisting of 2 nos 30 mm thick cuddappah stones, machine cut machine polished on exposed sides, placed back to back, sandwiched between the stones with 40 mm thick CM1:4 (Using factory made Ready Mix Plaster only).
For vertical support of Counter/ platform, consisting of 1 no 30 mm thick machine cut machine polished on one side cuddapah stone slabs and other side 18mm thick jet black granite stone back to back, sandwiched between the stones with 52 mm thick CM 1:4 (Using factory made Ready Mix Mortar only) including rubbing and polishing of cut edges all in line, level, plumb etc. complete.
Providing machine mixing and laying in approved panels of 40mm thickness IPS flooring in cement concrete mix of 1:2:4 using graded stone aggregate of 12.5 mm max. size with colouring pigment, at all level, well vibrated, compacted including providing and fixing 25mm x 3 mm thick aluminium dividing strip for panel of about 2 sqm size, to correct level and finished smooth and curing including preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond, all complete as per specification drawing & as directed by Engineer-in-Charge.
Cement plaster 20mm thick in skirting with cement mortar 1:4 (1 cement : 4 coarse sand), in shafts etc. using factory manufactured pre-mix / ready mix mortar/ Ready mix plaster(RMP), of approved manufacturers including transporting, loading, unloading, mixing at site and applying as per manufacturer's specification, preparing the surface, finishing to correct line,level, plane, plumb including rounding of junctions with flooring, finishing with neat coat of cement, including using richer mix for making corners if necessary, curing, etc. complete as per specifications, drawings & as directed by Engineer in charge.
Providing laying and fixing in position precast cement concrete shot blasted combination Paver tile in flooring of approved 2 colours manufactured by M/s Super tiles & Marble Pvt.Ltd. or approved equivalent, laid over cement mortar 1:4 using Ready Mix Mortar, 20mm thick over existing PCC/ RCC and well consolidated subbase underneath, all as per manufacturer's specification and as per approved design, pattern, shade from the catalogue,including transporting to site, placing to proper line & level, jointed with cement slurry & grouted with pigment of matching shade including filling the joints cost of all material, labour,tools, complete all as per drawing, specifications etc, but excluding the cost of PCC which will be paid separately, as directed by the Engineer in charge.
Combi shot blasted tiles of Cement concrete grade not less than M35 using (minimum 35mmthick - 150 series) of approved two colors for Pargola areas, Open Play area, 900mm wide plinth protection alround building as per drawing and as instructed by Engineer-in-charge.
TOTAL OF PART -I-F : FLOORING WORK
PART I-G : DOORS AND WINDOWS Note: a) The items of door frames, window frames shall include sealing the joints all round with the masonry work/ concrete and doors or windows with approved mastic filler cement grout/ epoxy compound/polysulphide compound or by any other means whatsoever, by the contractor at his own cost as directed by the Engineer-in-Charge to make the joints watertight. b) The work contemplated under the item for supplying and fixing the window/door frames shall be got done by the contractor through specialised agencies in the field, approved by the Department. c) One sample each of the door frame, shutter and window with all fittings and fixtures along with locking arrangement including glass panes etc. complete as per schedule of quantities drawing and specifications should be submitted for preliminary inspection before procurement on large scale. The contractor shall submit six copies of shop drawings for windows, ventilators and steel door with frames showing dimensional details of construction etc. for approval of the Engineer-in-charge. After preliminary inspection, the sample should be fixed. Defects etc, if any shall be rectified to the full satisfaction of the Department and after obtaining formal approval in writing of Engineer in charge. d) Door frames, shutters and the windows to be supplied and fixed in position should cater the dimensional tolerance of the openings to an extent of (+/-) 2%. The rates quoted by the tenderers should hold good for such variation. Test shall be conducted by the Department for the flush doors as per IS-2202-1983 Part-I from each consignment and the cost incurred on this account shall be borne by the contractor. e) For bonding the flush doors, block boards, ply wood and all types of wood works, phenol- formal dehyde synthetic resin type adhesives conforming to IS-848-1957 shall be used. f) The rate shall include cost of making the doors & windows etc. in all geometrical shapes and sizes without any extra cost to the Department. g) Decorative veneer and lamination sheets if mentioned shall be hot pressed at factory during manufacturing of door shutters.
Profile 145mm x 60 mm with single rebate.
Profile 80mm x 60 mm with single rebate.
Supplying & fixing in position the following type prelaminated solid core block board flush door shutters conforming to IS 2202 (latest) of M/s Kalpataru, M/s. Anand, M/s Kutty with internal type second class teak wood lipping alround and internal type teak wood beading of size 10mmx20mm alround on both sides of glass panes for vision panels, fixing shutters in position to pressed steel door frames/wooden frames/granite frame works (door frames shall be paid separately under relevant item) at all floors by cutting / planing the shutter if necessary including labour for fixing of the fittings & fixtures as per drawing with wooden packing pieces if necessary (but excluding the cost of fittings and fixtures with screws which shall be paid separately under relevant item) fixing laminate over the sides of beading and polishing the edges of Lipping all complete as per specifications, drawings & as directed by Engineer-in-charge.
50mm thick door type D5, single leaf solid core block board shutter of approximate size 1000mm x2400mm, prelaminated using 1.0mm thick laminate on both sides and internal typelipping of size 50mmx20mm on the sides
38mm thick door type D1/ D2/ D3/ D7, Double leaf/ single leaf solid core block board shutter of approximate size 2000mm x 2400mm / 1000mm x 2400mm/ 750mm x 2250mm pre laminated using 1.0mm thick laminate on both sides and internal type lipping of size 38mmx20mm (andfor double door lipping of size 38mm*50mm cut to profile at shutter meeting point), providingvision panel of size 400mm x 400mm (using 4mm thick clear transparent float glass of M/sSaint Gobain or approved equivalent, with second class teak wood internal beading of size10mmx20mm alround on both sides of glass panes).
Type D4 of size 700mm x 2400mm including providing & fixing accessories of 4 nos. heavy duty premium 100mm long stainless steel premium hinges, two nos 40mm dia SS cylindrical knob with concealed screw as handle, 2 nos C type 150mm long SS handle, 2nos. 100mm long SS flat type baby latch etc. complete.
Type D6 of size 900mm x 2400mm approx. including providing & fixing accessories of 4 nos heavy duty premium Double action/ both side openable spring loaded stainless steel hinges conforming to IS 453 : 1993 (Reaffirmed – 2003), two nos 40mm dia SS cylindrical knob with concealed screw as handle, 2 nos. 100mm long SS flat type baby latch etc. complete.
Type Dt of size 1000mm x 2150mm including providing & fixing accessories of 4 nos 125mmlong heavy duty premium stainless steel hinges, 2 nos C type 150mm long stainless steel handle, 250mm long stainless steel aldrop with extra staple, 1 nos 200mm long SS tower Bolt, all as per Drawing etc. complete.
Providing and fixing factory made prelaminated, 1 hour Fire Resistant non-metallic wooden solid core block board shutter not less than 50mm thick, asbestos free, Fully INSULATED composite fire resistant single leaf shutters conforming to BS:476, part 22, integrity, insulation and stability criteria as per IS:3614 Part 2, as per prototype tested & certified by CBRI Roorkee, suitable for mounting on door frames, all as per manufacturers specification with heat activated intumescent fire seal strips of size 12mm x 4mm mounted in the grooves in the shutter on all sides or in the door frame or in both, (Fire Resistant certification as required by CFO shall be furnished by Manufacturer of Door Shutter), providing & fixing view panel and fixing shutters in position to pressed steel door frames/ wooden frames/ granite frames [door frames (choukhat) shall be paid separately under relevant item] at all floors by cutting/ planning if necessary including cost of fittings & fixtures as per drawing with wooden packing pieces if necessary (but excluding the cost of fittings and fixtures with screws which shall be paid separately under relevant item) fixing laminate over the sides of beading and polishing the edges of Lipping all complete as per specifications, drawings & as directed by Engineer-in-charge.
50mm thick fire door of 1 hour rating, door type FD1, single leaf Solid core block board shutter of approximate size 750mm x2250mm, prelaminated using 1.0mm thick laminate on both sides and internal type lipping of size 50mmx20mm, with vision panel of size 400mm x400mm (using 4mm thick clear transparent float glass of M/s Saint Gobain or approved equivalent, with second class teak wood internal beading of size 10mmx20mm alround on both sides of glass panes).
Providing & fixing in position approved quality 2nd class teak wood architraves of finished section for the following sizes fixed to pressed steel frames of door/ cup board at all floors as per drawing including providing and fixing M.S. self taping screws at 600mm centers,painting with two coats of synthetic enamel paint of approved make & colour over one coat of approved primer etc. all complete as per specification & drawings.
Size 50mm x 20mm with chamfer, groove, corner notch 2mm x 2mm / 3mm x 3mm etc. as per drawing.
For Door type ED1 of approximate size 2000mm x 2400mm with louvers at top and bottom (cost includes providing and fixing 250mm long MS Aldrop with an extra staple, Hinges, Handles, tower bolts as specified above)
For Door type ED2 of approximate size 1200mm x 2400mm or as per size shown in plan, with louvers at top and bottom(cost includes providing and fixing Built in type lock connected with movement of MS Handle, Hinges, Handles, tower bolts as specified above).
Supplying and fixing in position at all floors integrated bronze anodised matt/glossyfinished [15 micron thick], aluminium section [extruded] for aluminium Door / windows sliding/ top hung/ fixed / grill/ adjustable louvered/ windows as per drawing of approved manufactures with extruded sections of Jindal(Domal series) / Hindalco / ALOM extrusion orother approved equivalent sections with size and weights as shown in the drawing, forframes and shutters [including wastages if any] conforming to relevant I.S specifications withall approved Bronze anodised aluminium fittings and accessories, locking arrangements(flush type self locking handle), 3 nos heavy duty rollers with ball bearings forsliding shutters, of approved quality as per specification all as shown in the drawing,including providing and fixing aluminium channel beading / glazing clips fixed with necessary bronze anodised screws, grouting the gap with thermocole & polysulphide sealant etc. all complete generally as per drawings, specifications etc., all as directed by Engineer-in-Charge but excluding the cost of glazing which shall be paid separately. Note: 1) Sliding window sections for both track & Shutters shall be of JINDAL DELUXE DOMAL SERIES or similar equaivalent approved make . 2) Approval of the Dept. for the complete design and shop drawing shall be obtained before commencement of the fabrication work
Providing and fixing following type of approved quality glass panes for doors/ windows/ventilators, of M/s. Modiguard/ M/s Saint gobain or approved equivalent, and fixing with aluminium framework including fixing aluminium channel beading (to be paid under releventitem) and providing and fixing with 2 way EPDM gasketing, to ensure water and air tightness and neoprene cushions /gasket accommadated in grooves, necessary bronze anodised screws etc., all complete generally as per drawings specifications and as directed by the Engineer-in-charge.
5 mm thick clear float glass.
5 mm thick tinted glass for wall span WS1.
5 mm thick & 75mm wide frosted glass for adjustable/fixed louvers.
6 mm thick reflective toughened glass of colour(super silver Brown) or as approved.
TOTAL OF PART I-G : DOORS AND WINDOWS
PART : I-H : FITTING & FIXTURES: Notes: i) One sample board consisting of each item of schedule of quantities with approved quality fittings & fixtures & necessary accessories including chromium plated brass screws, bolts, nuts, washers should be submitted for approval of Engineer-in- charge. Large scale procurement shall be taken up only after approval of the Engineer-in-charge. After approval, the samples shall be kept in the office of the Engineer-in-charge to ascertain the approved quality for the entire work. ii) All fittings & fixtures shall conform to relevant IS code.
Supplying at site of work approved quality and manufacturer (M/s Shalimar or other approved equivalent) Stainless steel (SS-304) fittings, fixtures and fastenings along with Stainless steel screws, bolts, nuts, washers, wooden packing pieces if necessary etc. and other accessories etc complete.
Tower bolt: 300mm. long x 15mm barrel.
D Type Bow handle 150mm long .
Aldrop 250mm long x 16mm dia. rod with an extra staple.
Door stopper with rubber bushing (shutter mount type)
C type 750mm long 25mm dia. SS pipe handle with necessary SS fittings and concealed screws .
C type 300mm long 30mm dia. SS pipe handles with necessary SS fittings and concealed screws.
'Supplying at project site approved quality non magnetic stainless steel fittings, fixtures and fasteners along with necessary SS screws, bolts, nuts, washers etc. wooden packing pieces if necessary and other standard accessories , as per approved samples Butt Hingesof following sizes.
Heavy duty stainless steel-304 grade premium hinges 125mm long and dimensions as per IS code 12817.
Supplying and fixing following type of approved quality miscellaneous fittings, fixtures and fastenings along with necessary SS screws, bolts, nuts, washers and other standard accessories.
Mortice lock with six lever chromium plated brass body and parts of M/s Godrej make with pair of detachable, pressure dia-cast chromium plated handles on both sides with chromiumplated brass screws for left hand/right hand with brass socket plated, (exact number for left,right and double shutter shall be ascertained based on site requirement) all complete as perspecifications & as directed by Engineer-in-Charge.
Heavy duty SS Floor Springs as per M/s Godrej or approved equivalent.
Heavy duty concealed type Door Closer as per M/s Godrej or approved equivalent.
Concealed type 6 lever locks of M/s Godrej or approved equivalent for entry doors of Aluminium wall span WS1 and WS2 lockable from both sides, all complete.
Concealed type stainless steel tower bolt for aluminium wallspan WS1 and WS2
TOTAL OF PART : I-H : FITTING & FIXTURES:
PART - I-I : WATERPROOFING TREATMENT: a) The contractor shall get written approval from the Engineer in Charge for the water proofing agency engaged and shall submit the specification of the waterproofing before commencement of work. b) The contractor shall test the surface where water proofing treatment is provided for bone dry condition by filling up with water. No wet patches or leaks shall appear on the surrounding wall or under side of the slab c) The contractor shall furnish guarantee bond on appropriate stamp paper in the proforma as per Section10 (iii) of Conditions and Clauses of Contract - 2008 for the entire waterproofing treatment for maintaining the surroundings and under side surfaces of the waterproofing treated area in bone dry condition for 10 years. During the guarantee period the contractor shall attend all leakages, defects etc. if noticed, free of cost, starting the work of checking up and rectification with in a week's time from the date of intimation about such leakages/ defects. d) The Contractor shall keep the water tank filled with water after the water proofing work has been completed and shall clean it before handing over. At no time shall the water tank be kept empty. Testing for the bone dry condition for the water proofing work carried out shall again be done, before handing over the Building/ flats, if found necessary by the Engineer in Charge. e) Wherever Cement motar is to be used it shall be with Ready mix mortar for all waterproofing work with suitable proportioning for richer mix.
Providing and laying integral cement based water proofing treatment of the agency approved by department, including preparation of surface as required for treatment of roofs, terraces etc mixing with waterproofing compound as per IS : 2645 :2003, with average thickness of 115mm and minimum thickness at drain point as 65 mm. Following works are included in above item. a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound over the RCC slab including cleaning the surface before treatment. b) Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of Readymix mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound over 20 mm thick layer of Readymix mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary waterproofing compound. d) Finishing the surfaces with 20 mm thick joint less cement mortar using readymix C.M 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound and finally finishing the surface with trowel with neat cement slurry & making pattern of 300x300mm square 3mm deep or suitable to receive the China Mosaic waterproofing treatment wherever specified. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
Extra for additional thickness of brick bat coba using ready mix mortar over and above standard average thickness of 115 mm. for effective slope wherever required.
Filling in bath, W/C, toilet, depressed areas with water proofing brick bat coba of the agency approved by the Dept. at all floors and locations upto the required level and making the surface finished suitable to receive floor finish etc. all complete as per drawings and waterproofing agency's specifications & as directed by the Engineer-in-Charge.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., Kitchen and the like consisting of : i) 1st course of applying cement slurry @ 4.4. Kg/sqm mixed with water proofing compound `Impermo' of Snowcem or equivalent conforming to IS 2645 in recommended proportions. ii) IInd course of cement plaster 1:3 (1 cement : 3 coarse sand) using Ready Mix Mortar mixed with water proofing compound in recommended proportions, 20mm thick up to finished floor level and 15mm thick above finished floor level up to 600mm. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm of area. iv) IV th course of 200 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.)
Providing cement based waterproofing treatment by 'Injection & Surface' method of the agency approved by the dept. of 50mm for floor and 20mm thick for the walls of the over head water tank on terrace, finished perfectly smooth to correct line, level and plumb including preparing the existing surfaces, necessary scaffolding, curing etc. complete as per waterproofing agency's specifications and testing water tank for the water tightness and rectification of defects, if any, to render the outer surface bone dry etc. complete as per specifications, drg. & as directed by the Engineer-in-Charge.
Providing China Mosaic water proofing over concrete/plastered surface of horizontal, vertical, sloped/ curved surfaces, rounded vatas, sharp corners, junctions etc., using broken pieces of approved uniform colour ceramic tile laid over and including 20mm thick cement mortar 1:3 using Ready mix mortar, screed mixed with approved waterproofing compound @ 2% by weight of cement, cost of all materials, labour, curing, breaking the tiles to the pieces of required size and shape, laying / fixing the tile pieces to the required line, slope, levels etc., providing extra screed as required for quick & easy flow of Rain water, curing etc., at all heights including necessary scaffolding, cleaning the surface initially with saw dust and finally with acid all as per specifications and as directed by the Engineer-in-Charge.
TOTAL OF PART - I-I : WATERPROOFING TREATMENT:
PART I - J : PLASTERING WORK : Note: a) Before commencement of plastering, the area shall be cleaned, wetted and shall be marked with 'Thiyyas' or 'Tapanis' and shall be got approved by the Engineer-in-charge. b) Whenever the electrical contractor/ agency has to fix up switch boxes in walls, necessary Thiyyas or 'Dhadas' shall be arranged prior to plastering so that the electrical boxes are fixed properly in line with the finished plastered surfaces. c) Finishing around the junction boxes shall be done at all floor, level and position to the line, level and right angles as required while carrying out plastering work. d) No extra claim/cement consumption shall be entertained by the department for the plastering done more than the specified thickness shown in the schedule of quantities, to bring the plastered surface to perfect line, level and plumb with adjoining columns and beams. e) Only Ready mix Mortar of approved make shall be used. For richer proportion additional cement to be added in required proportion.
Cement plaster using READY MIX MORTAR (RMM) of approved manufacturer (Roofit Mix, Wallplast, Readiplast, Silcoplast) in single/ double coat as specified over Concrete surfaces in thickness as mentioned, in C.M 1:4 or richer by proportionally increasing cement content as required, over plane or curved surfaces at all level including rounding of surfaces wherever required, prepare the surfaces even and smooth in correct line, level, plane and plumb including scaffolding, chemical curing etc. complete as per specification drawings and as directed by the Engineer in charge.
6mm thick cement plaster in Cement mortar (1 cement : 4 fine sand) for , exposed concrete surfaces, soffits of all slabs and beams soffit of staircase waist slab etc. as per finishing schedule in the drawing.
15mm. thick plaster in CM 1:4 mix for internal brick / concrete surfaces for all walls, beams flushed with walls, mullions etc.
Smooth finish cement plaster as mentioned below in CM 1:4, using factory manufactured pre mix/ ready mix of 'Roofit Mix' of M/s Premier Floor to Roof Materials pvt.ltd/ 'Build Well ready mix plaster' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd / Readymade polymerised Dry mix Plaster - Silicoplast of M/s. Precise Conchem Pvt. Ltd.or other approved equivalent make, having minimum composition of Cement : Sand as 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces final rendering, including using richer mix for making corners if necessary and making nosing / dripmould in plaster at all floors, levels, all heights and locations including scaffolding, preparing the surfaces, finishing and rendering with sponge to correct line, level and plumb, curing/ chemical curing etc. complete as per specification and drawings and as directed by Engineer-in Charge.
20mm thick in two coats for brick/ concrete surfaces (external / internal) (back coat and finishing coat of 10 mm. thick each) with water proofing agent @ 2% by weight of cement..
12 mm. thick in single coat for independent concrete surfaces with waterproofing agent @ 2% by weight of cement or as per manufacturer's specifications.
Extra over plastering items for making Plaster grooves and finishing in matching plaster finish (interior & exterior) grooves of sizes as per drawing in plaster, at all floors and locations to proper line, level and plumb all as per specifications and drawings
25 x10mm size
Providing vatas 150 x 150 mm at junction of walls and chajjas, canopies etc. with cement mortar 1:3 using Ready Mix Mortar (RMM) to match the surrounding plaster to the required profile including adding water proofing compound @ 2% by weight of cement, scaffolding, curing etc. complete as per specifications and drawings and as directed by the Engineer-in-charge.
TOTAL OF PART I - J : PLASTERING WORK :
PART : I-K : PAINTING :
Providing and applying 1.5mm thick cement base wall care putty in two coats of approved manufacturers at all floors and locations, over plastered surfaces finished smooth to correct line, level, plane, plumb etc., including preparing the surfaces, scaffolding smoothen the putty surfaces with very fine water proof emery paper to get a glossy finish etc. complete as per specifications, as per manufacturers specifications, drawing & as directed by the Engineer-in-charge.
Painting plastered /concrete surfaces with two coats of acrylic emulsion & paint of M/s Asian paints or at par approved equivalent, in approved colour over a coat of approved primer including preparing the surfaces, filling with putty wherever required, scaffolding and cleaning etc., complete as per specifications, drawings and as directed by the Engineer-in-Charge.
Painting plastered /concrete surfaces with two coats of exterior grade Acrylic (plastic) emulsion paint of M/s Asian Paints or at par approved manufacture and approved colour, pattern and shade over a coat of acrylic based water repellent primer of approved make and shade as mentioned below all as per manufacturer's recommendations and as per the approved sample including providing necessary scaffolding,cleaning the surface with water to remove all coating, dust, filling up cracks & crevices with approved putty, curing the surface etc. complete as per specifications and as directed by Engineer-in-Charge.
Over smooth finish external plaster.
TOTAL OF PART : I-K : PAINTING :
PART : I-L : MISCELLANEOUS WORKS Note: One sample of each item should be submitted for preliminary inspection and approval before procurement/ manufacturing on large scale. After the preliminary inspection and approval, the sample should be fixed at site or kept in the office of the Engineer-in-charge till completion of the work.
Structural steel work at all floors and locations in grills, guard bars for windows, frames, Fence, pit/ trench covers, cover bracket for slanting chajja, trap door, railing, balcony hand railing, hoisting hooks, smoke vents etc. using angles, channels, tees, flats, bars, chequered plates etc. of required sizes including supplying, cutting, fabricating, welding, erecting, making holes/ chases wherever required and fixing / embedding in position in concrete/ brickwork/block/ marble/ granite stone with necessary hold fasts/ stainless steel screws & rawl plugs by drilling etc. and finishing the concrete/ brick/block work after fixing/ embedding including painting two coats of anticorrosive bitumastic paint on all unexposed surfaces and two coats of synthetic enamel paint of approved make and colour on all exposed surfaces over a coat of approved primer etc. complete as per specifications, drawings and as directed by the Engineer in charge.
Supplying and fixing in position various dia GI pipe for sleeves, railing, ladder at terrace for over head water tank, using 'B' class (medium duty) GI pipes of any diameter as per requirement and as per drawing for verticals and steps/ Railing/ spout/ sleeves etc. including cutting, bending, welded properly in line and level to the verticals, providing necessary bracings, hold fasts etc. at all levels and anchoring the ladder/ railing with necessary brackets fixed in cement concrete 1:2:4, finishing including painting all exposed surfaces with two coats of synthetic enamel paint of approved make and colour over a coat of approved primer etc. complete as per specifications, drawings and as directed by the Engineer in charge.
Providing and fixing thermal under deck insulation using 50mm thick Phenotherm board made of Phenolic Foam with kraft paper on both sides manufactured by M/s Bakelite Hylam or approved equivalent at ceiling of Roof slab at all levels and locations including applying a coat of shali coat to the underside of the roof and CRPX compound to the underside of each board and pressed to the slab in position, fixing with suitable screws (5 Nos. stainless steel screws per panel of 1200mm x 600mm) with rawl plug and washer, including sealing the joints with self adhesive brown tape etc. complete all as per manufacturer's specification, cost of all materials, labours, scaffolding, tools & plants, required for completion of the work etc. all complete as per drawing and as directed by the Engineer in Charge. Note:- Any drilling operation for Fixing of thermal insulation shall be done before carrying out terrace waterproofing works.
Providing & laying 100mm to 300 mm thick, as per design shown in the drawing, Cement concrete coping of mix 1:1.5:3 over window / Ventillator Cill, parapet wall, etc. including formwork in all shapes, mechanical mixing of concrete, consolidation, finishing, making slope, curing including the cost of plastering with Ready Mix Mortar in CM 1:4, 20mm thick, etc. finished with neat cement all complete as per drawing, specification & as directed by Engineer in charge.
Providing, fabricating and fixing Galvanized M.S Gate (Double leaf and single leaf as per drawing), using G.I Chain link mesh of size 50mm * 50mm *4 mm dia, fixed/welded to G.I frame work made with Galvanised Pipe of 50mm diameter, in combination with Galvanised Structural Steel sections such as angles, Channels, flats, G.I sheet etc., fixing to Square M.S Post( to be paid under relevant item), with heavy duty Pivot Hinges(minimum 3 nos. per shutter), including providing necessary locking arrangements such as Alrdop, Tower Bolt, etc. on both sides , including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer etc. all complete as per specification and as directed by Engineer-in-Charge.
Galvanized structural steel frame work for Gate work.
Gavanized Ghain link Mesh of size 50mm X 50mm with 4mm dia GI wire for Gate work.
Supplying, fabricating, fixing in position G.I. chainlink fencing of 50mm x 50mm and 4mm dia. wire, with chain link net fixed to M.S square pipe frame (M.S. works shall be paid under relevant item) including cost of hooks, bolts, nuts, washers required if any and painting chain link and MS frame work with two coats of synthetic enamel paint over a coat of approved anticorrosive primer, etc.complete generally as per specifications, drawings as directed by EIC.
Providing and fixing in position at all floors, levels / heights 18 mm thick mirror polished natural stones slab for door/window frame in single/ two overlapping layers in one piece for full length / height of approved shade, finished sizes as directed including machine cut / hand cut, final cleaning, moulding and polishing of exposed edges, in line, level, plumb and fixing the stone with CM 1:4 (Using factory made Ready Mix Mortar only) and necessary SS screw, 20mm backing & overlapping of 20mm shall be fixed with Araldite adhesive, with best workmanship, finishing, curing, etc. complete all as per specifications, drawings & as directed by the EIC. Note:- 1) All finished natural stones except for floorings shall be applied with araldite or equivalent stone adhesive on back surface, spreading/splashing of sand particles on adhesive applied surface before a day of fixing of stones. 2) Window jamb, cill & soffit with granite shall be mitred / partly mitred joint as directed by Eingineer-In-Charge. 3)Exposed surface on Elevation & exposed vertical finished face shall be measured for payment in sqm. Overlapping & edges etc shall not be measured.
In 2 layers, 18mm thick machine cut, Brown / Jet Black Granite Stone for doors and windows, in cill and jamb, in stepped form.
In single layer, 18 mm thick machine cut and single side machine polished, Brown / Jet Black Granite stone for window soffit (bottom of lintel)/door frame(for type D6 door i.e. both side opening door), in single piece laid over 20 mm thick 1:4 cement mortar (Using factory made Ready Mix Mortar only) including half round moulding & polishing of exposed face etc. complete.
Providing & fixing in position GI chicken wire mesh (Hexagonal shape) of 12mm size hole, 22 Gauge with necessary "U" hooks, clips or nails at all floors and levels, wherever required to prevent development of cracks in plaster surfaces, as per specifications, drawings and as directed by the Engineer-in-Charge (Only area of chicken mesh provided shall be measured for payment).
Supplying, applying and placing swellable type water stop tape of size 19mm x 25mm thick of expansive nature for construction joints of RCC walls of water tank including cleaning the construction joints of loose mortar and dust, applying primer as per manufacturer's specification, unroll the water bar slowly and carefully on the joint without pulling and stretching it too much after the primer dries a little and became sticky and tying with the reinforcement bars as directed all complete as per manufacturer's specification.
Providing & fixing in position suspended false ceiling system using 600 x 600 mm Calcium Silicate Ceiling tiles (Aerolite) Ceiling Systems Tiles having 15mm densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approved surface design and edge profile (Tegular/ Spintone) placed in a suspended grid of size of 600 x 600mm made of hot dipped G.I. steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200mm centres along the length of ceiling with 4mm dia G.I wire with necessary level adjusters and cross tees of size 24 x 28 x 0.33mm x 1200mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees of size 24 x 28 x 0.33 mm x 600mm shall be inserted to form a grid size of 600mm x 600 mm resting on the periphery walls on wall angles of size 22mm x 22mm x 300mm x 0.40mm thickness etc. complete as per specifications, drawings and as directed by the Engineer-in-Charge. Note:- The entire grid system shall be designed to bear a distributed load of minimum 15 kg/sqm.
With approved surface design "Cosmos" of M/s Aerolite.
Providing and laying 80mm thick factory made cement concrete interlocking paving blocks of M/s Basant Batons, M/s Super tile or approved equivalent(M-35 grade) made by block making machines with strong vibratory compaction and approved size, shape, design laid in required colour and pattern with two coats of Laquer finish, placed over and including 50mm thick compacted bed of stone dust, filling the joints with crushed stone etc. all complete as per the direction of the Engineer-in-charge
Providing and fixing precast Kerb stones, of M/s Basant Batons, M/s super tile or approved equivalent made of cement concrete of grade M20 (using graded stone aggregate of 20 mm max. size) of size 125 x 375mm/300 mm, curved at inner edge of 25 mm radius including necessary form work, consolidation, finishing, curing, fixing with CM 1:3, jointing and pointing in CM 1:3 and painting the all exposed surfaces with two coats of synthetic enamel paint of approved colour and shade over a coat of approved primer etc. complete as per specifications and as directed by the Engineer- in-Charge.
Providing & fixing GI Mesh size (100mmX100mmX2mm) IRC-fabric at mid- depth of concrete cover to bottom reinforcement of suspended slab/beam, wherever there is risk of concrete spalling, such as bottom slab of water tank etc. The rate shall include cost of labour, materials, binding wire, cutting, bending, binding, strainghtening, placing in position & for welding with main reinforcement of slab, beam etc. complete as per specifications, drawings and as directed by the Engineer in charge.
Supplying and fixing 110mm dia and 300mm long(approx.) using PVC-SWR pipes for weep holes etc., of approved make and with ISI mark including laying the pipe to proper slope and gradient, including cutting to required length etc. complete as per specification and as directed by the Engineer in charge.
Cement plaster 15mm thick with water proofing agent @ 2% by weight of cement, for brick supports of pipe line etc. in cement mortar 1:4, using Ready mix plaster(RMP) of approved manufacturers such as M/s Ultratech Ltd., M/s Roofit, including transporting, loading, unloading, mixing at site, scaffolding, preparing the surface and applying as per manufacturer's specification, at all heights and locations on plane or curved surfaces including rounding wherever required, preparing the surface even and smooth to correct line, plane and plumb, curing etc. finishing with neat coat of cement, complete as per specifications, drawings and as directed by the Engineer-in-Charge.
Supplying and fixing in position at all floors and location stainless steel 304 grade mosquito net made out of 28 guage 16 mesh shutters of various size and shape fixing with stainless steel nuts and bolts to suit the aluminium frame (aluminium frame, beading etc. shall be paid under relevant item) including labour wastage scaffolding etc. all complete as per drawing , specification and as directed by Engineer in charge.
Demolishing existing Nalla of RR masonry/ RCC including shoring, scaffolding, separating steel bars, properly stacking, cleaning, leveling the entire plot to natural ground level, disposing off the debris generated out of demolision and dismantling works by mechanical transport with all leads and lifts to the nearest approved disposal ground of MCGM including all lifts, loading, unloading, stacking, spreading, levelling etc. complete all as per guidelines of Construction Demolition (C&D) waste management plan, as approved by MCGM etc., complete all as directed by the Engineer-in-charge.
Providing and fixing of signages of following sizes using Rigid sheet (A)ARS 10000 for the written matter (as described below), fixing to the base of 2mm thick Acrylic sheet using appropriate glue and stainless steel screw with washers etc. and providing arrangement for hanging the assembly to the ceiling including the cost of 2 sets of Stainless steel hangers, anchor fasteners, SS cover plates, hooks, etc. or fixing it to the wall, door as per drawings, complete as per manufacturer's specification and as per instruction of EIC.
Autoglow signages :
size 300mm x 300mm for "EMERGENCY EXIT" model D 160 Autoglow, Hanging type.
size 200mm x 300mm for "STAIRS" model No. C 25 / D 160 Autoglow, Hanging type.
size 200mm x 400mm for "FLOOR NUMBER-X" model No. FE 25 Autoglow, Fixing to wall type.
No glow signages :
size 300mm x 300mm for "SPECIALLY ABLED TOILET" model C 25. for fixing to wall/ door.
size 200mm x 300mm for "GENTS TOILET"/"LADIES TOILET"/ "ELECTRICAL PANEL ROOM" model No. C 25 for fixing to wall/door.
size 100mm x 300mm for "FIRE SHAFT"/ "TELEPHONE SHAFT"/ "ELECTRICAL SHAFT/Staff Change Room" model No. C 25 for fixing to wall/door.
size 300mm x 400mm for "FLOOR PLANS (YOU ARE HERE)" model No. C 25 for fixing to wall/door.
TOTAL OF PART : I-L : MISCELLANEOUS WORKS
Description of Work / Item(s)
Amount
ABSTRACT OF PART - II
PART - II - PUBLIC HEALTH ENGINEERING WORKS
PART - II - A - Sanitarywares & CP Appurtenances
PART - II - B - Water supply system
PART - II - C - Drainage system
Description of Work / Item(s)
Amount
Part II : PHE WORKS
Part II-A : Sanitarywares & C.P Appurtenances. Note:- 1) All sanitaryware shall be provided from same brand 2) All CP fittings / Fixtures (except jet spray) from same brand shall be provided.
Providing and fixing in position following Vitreous China Wall Hung type Wash down pattern water Closet consisting following items of work:- i) Providing Vitreous China wall hung type wash down pattern Water Closet ( EWC ) conforming to IS 2556 (part XVI) with integral "P" trap outlet with water seal not less than 50 mm with vent and necessary C.I. brackets supports. ii) Providing thermosetting or thermoplastic Seat & cover conforming to IS 2548, fixing seat & cover for water closet as per manufacturer's specification including the cost of corrosion resistant hinges, bolts, nuts, non ferrous or S.S washer etc. all complete. iii) Fixing the Water closet in position, jointing the trap, water closet and UPVC pipe by Epoxy grout or Rubber seal as per pipe manufacturer. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching colour cement etc. all complete. v) Testing the system to the full satisfaction of the Engineer-in-Charge.
White glazed vitreous China EWC as per Hindware cat.No. 20069/20097 lara model with slow falling seat cover or Cera cat no S1041111 cruse model with slow falling seat cover or Parryware cat no Co264 Cardiff model with slow falling seat cover or equivalent model.
Providing and fixing in position following Vitreous China pedestal type Wash down pattern water Closet, consisting following items of work:- I) Providing Vitreous China pedestal type wash down pattern Water Closet ( EWC ) conforming to IS:2556 ( part II ) with integral "P" or "S" trap outlet with water seal not less than 50 mm and with vent. ii) Providing thermosetting or thermoplastic Seat & cover conforming to IS:2548, fixing seat & cover for water closet as per manufacturer's specification including the cost of corrosion resistant hinges, bolts, nuts, non ferrous or S.S washer etc. all complete. iii) Fixing the Water closet in position, jointing the trap, water closet and C.I pipe by water proof cement joint using cement mortar 1:2 and hemp yarn. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching cement etc. all complete. v) Testing the system to the full satisfaction of the E.I.C.
White glazed vitreous China EWC as per Hindware cat. No. No. 20011 'Slick' with slow falling seat cover or cera conventional cat. No. S1050101/2 or equivalent.
PONCHO EWC as per Hindware cat. No. 20062 with seat cover or equivalent.
Providing & fixing in position first quality vitreous China Indian water closet consisting of following items of work:- i) Supplying Vitreous china Indian water closet ( Box rim pattern ) of following type conforming to IS:2556 ( part-II) with integral foot rest, W.C Connector and PVC "P" or "S" trap having water seal not less than 50 mm with / without vent as per requirement. ii) Fixing the Water closet in position, jointing the trap, water closet and PVC pipe using straight/ bend/reducer type W.C connector with Rubber Ring joint or as per manufacturer's requirement including the cost of connector and jointing materials all complete. ii) Cutting hole, making groove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, finishing the gaps with white / matching cement etc.complete. iii) Testing the system to the full satisfaction of E.I.C.
Vitreous China Water Closet of 580 x 440 mm size of Starwhite/snow white/bright colour as per Hindware Cat. No. 20042 "Orissa Pan Eco" model or Cera cat. No. S3020105 "Orrisa Pan Cable" model Or Parryware Cat. No. C0117 "Orrisa Pan" model with PVC / ceramicTrap (with/without vent) & WC connector etc.all complete.
Providing and fixing urinal of approved make consisting following items of work i) Providing urinal of approved make, and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete. ii) Providing various CP fittings such as Waste Coupling of Jaquar Cat No. 705/709, Bottle Trap of Jaquar Cat. No. 769 including provision and fixing 32 mm minimum 10kg class PVC pipe conforming to IS:4985 (and fittings conforming to IS:7834) Waste Pipe from Bottle trap to adaptor / Nahani trap / Floor Trap. ( Bottle trap & waste coupling will be paid separately under the relevant item.) iii) Fixing the urinal in position, including providing M.S. Brackets & Screws for the urinal as per Manufactures specification or as directed by Engineer-in Charge. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Testing the system to the full satisfaction of the Engineer in Charge.
Vitreous urinal of Starwhite/snow white/bright colour as per Hindware Cat. No. 60010 "Dyna" model or Cera cat. No. S4020113 "Civic" model Or Parryware Cat. No. C0580+C8123 "Whiz" model with connector etc.all complete.
Providing and fixing squating urinal of approved make consisting following items of work i) Providing urinal of approved make, and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete. iii) Fixing the urinal in position, including providing cement based adhesives or cement mortar on floor as per Manufactures specification or as directed by Engineer-in Charge. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Testing the system to the full satisfaction of the Engineer in Charge.
Vitreous squating urinal of Starwhite (Standered) color of Hindware Make Cat. No. 60003 model or equivalent
Supplying and fixing Granite partition sandwitch type (both)18 mm thick of specified colour, from floor level polished with Pencil Nosing on all edges with proper adhesive Partition plate of following size, fixing the partition in position, embedding 75 mm deep into the wall with cement concrete of grade M-15, including cutting chases of size 75 mm X 100 mm in the wall, finishing the joints with white cement etc. all complete as directed.
1500 x 575 mm size or directed by EIC.
Providing Flushing arrangement to Water Closets including providing and fixing manually operated PVC low level Flushing Cistern consisting following items of work:- i) Providing 3.0/6.0 ltrs capacity white colour PVC Low level, leak proof, water saving , dual flush, durable concealed Flushing cistern with all inside syphonic fittings & flush plate, duly assembled confirming to IS 7231 of following make, fixing the cistern in position using CP brass screws, rawl plugs, brackets/ frame, etc as per the manufacturer's recommendation, making outlet connection with EWC including the cost of supplying & fixing PVC Flush pipe etc all complete. ii) Cutting hole, making chases in the wall, floors, slabs etc. and reinstating the surface to the original condition,painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer,finishing the gaps with white/ matching cement etc. all complete. iii) Testing the entire system to the full satisfaction of the E.I.C.
Providing and fixing PVC low level white colour concealed cistern, model 'Concealo (80mm)' including flush plate model ' cute' and concealed cistern frame- floor mounted Cat No. 511725 of Hindware or equivalent model in Roca/ toto , etc all complete.
Providing Flushing arrangement to Squating Urinals including providing and fixing manually operated PVC low level Flushing Cistern consisting following items of work:- i) Providing PVC low level flushing cistern with all inside syphonic fittings, duly assembled conforming to IS:7231 of in etc.as per the manufacturer's recommendation all complete.position using CP brass screws, rawl plugs, bracketsapproved make with handle, fixing the cistern. ii) Providing 40/32 mm dia.uPVC (6Kg) flush pipe from Flush tank to squating urinals, concealed in the wall as directed making connection with squating urinal including the cost of fittings, fixtures and jointing materials etc. all complete including providing & fixing 15 mm dia. PVC coupling with mosquito proof jalli at overflow outlet. iii) Cutting hole, making chases in the wall, floors, slabs etc. and reinstating the surface to the original condition,painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer,finishing the gaps with white/ matching cement etc. all complete. iv) Testing the entire system to the full satisfaction of the E.I.C. v) Flushing cistern and squating urinal shall be from the same manufacturer.
Flushing arrangement with low level Cistern 'Sleek Essence single Flush' model of HINDWARE' or equivalent model .
Providing Flushing arrangement to Urinal etc., including providing and fixing manually operated flush valves consisting following items of work:- i) Providing and fixing flush valve in position using CP brass screws, rawl plugs, brackets etc.as per the manufacturer's recommendation, making inlet and outlet connections all complete. ii) Providing 40/32/25/20 mm dia.uPVC Pipe(Waste) from Flush Valve to Water Closet concealed in the wall as directed making connection with Urinal and flush valve including the cost of fittings, fixtures, reducers, CP brass fittings on exposed portion and jointing materials etc. all complete. iii) Cutting hole, making chases in the wall, floors, slabs etc. and reinstating the surface to the original condition, painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer, finishing the gaps with white/ matching cement etc. all complete. iv) Testing the entire system to the full satisfaction of the E.I.C.
Flushing arrangement with flush valve of Jaquar 'Pressmatic' make Cat No.PRS-073, Flush bend, cutting hole, testing etc.for Urinal
Providing and fixing first Quality Vitreous China hand wash Basin Consisting following items of work. i) Providing Wash Basin and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete. ii) Fixing various CP fittings such as Waste Coupling of Jaquar Cat No. 705/709, Bottle Trap of Jaquar Cat. No. 769 including fixing 32 mm minimum 10kg class PVC pipe conforming to IS:4985 (and fittings conforming to IS:7834). Placing and fixing Waste Pipe from Bottle trap to adaptor / Nahani trap / Floor Trap. iii) Fixing the Wash Basin in position, including providing M.S./C.I. Brackets & Screws for the basin. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting , finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Fixing Vitreous China under / over the counter / semi recessed type Wash Basin of following model and make conforming to IS 2556 and placing it in position with the granite platform as shown in the drawing or as directed including finishing the joints with white cement all complete. vi) Testing the system to the full satisfaction of the Engineer in Charge.
Vitreous China Wash Hand Basin of StarWhite colour of Hindware Make Cat. No. 10096 and Cat. No. 11038 Studio model with pedestal or Cera cat no S2040112 + S 2090120 Concord model equivalent model.
Vitreous China Wash Hand Basin of Star White colour of Hindware Make Cat. No. 10065 Round under counter model or Parryware cat no Co448 Grand model under counter model or equivalent.
PONCHO Wash Hand Basin of Hindware Make Cat. No. 10077 model or equivalent.
Providing braided hose with nuts, nipples etc. for Water supply Inlet connection of following make for wash basin, flush tank, kitchen sink etc with brass check nuts on both ends and fixing it in position as directed including the cost of jointing materials and testing for leak proof joints all complete
450 mm long Braided hose of Jaquar cat. No. 805B or equivalent . in equivalent in Roca/Toto.
Providing & fixing in position best quality bevelled edge plate Glass Mirror with PVC frame of following size with 6 mm thick marine ply wood (confirming to IS:710 : 2010) , fixed with required numbers of CP brass cup screws and caps, washers etc. including drilling holes, providing & fixing rawl plug in RCC/ brick wall/block wall, wooden packing behind the mirror if necessary, reinstating the damages to its original condition etc. all complete as directed by EIC.
6 mm thick Plate glass Mirror of size 600 mm x 450 mm / of required size with 6 mm thick marine ply wood (confirming to IS:710 : 2010) backing & PVC mouldedframe of approved shade or as directed by the E.I.C
Providing and fixing in position 'Matric Set' in Paraplegic ( handicapped ) Toilets consisting following items of work of M/s Hindware make:- I) Providing Vitreous China pedestal type wash down pattern Water Closet (Matrix EWC ) conforming to IS 2556 (part II) as per Hindware cat. No. 20049 with integral "P" trap outlet having water seal not less than 50 mm with vent and necessary supports, seat cover with complete Fittings all complete. ii) Providing Matrix Wash Basin 460x360 mm size of Hindware cat. No. 10060, M.S / C.I brackets etc. and placing / fixing in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement and fixing / jointing materials all complete. iii) Providing 'Abigail' Cistern of Hindwarwe cat.No. 21030 and fixing in position over a pair of M.S brackets as per manufacturer's specification including the cost of brackets, fixing / jointing materials etc. all complete. iv) Providing one No. Hinged rail of 76 cm long & four Nos. Grab Rail, each 60 cm long of Hindqware make, fixing the rails in position at correct level & locations as per drawing / manufacturer's recomandations. v) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching colour cement etc. all complete. vi) Testing the system for leakproof joints & smooth functioning including recifying the defects, if any. NOTE :- The scope of above item does not cover providing & fixing Faucets, Bottle Trap, waste coupling & Inlet connections which shall be paid under relevant item.
Providing & fixing a set ( Matrix ) of Vitreous China European Water Closet of starwhite colour with Cistern & seat cover, Wash Basin with a pair mounting brackets, one no. hinged rail and four nos of grab rails all complete.
Providing & fixing in position following approved quality CP fittings / Fixtures of 15 mm nominal dia. with ISI mark / approved make of following type including providing & fixing specials, wall flanges and fixing to concealed / exposed pipe line with leak proof threaded joints using tephlon tapes, testing the joints hydraulically to a pressure of 10 kg./ sq.cm, rectifying the leaky joints. if any, including cleaning etc. complete all as per specification.
C.P brass 2 Way Bib Cock with wall flange of Jaquar 'Florentine' Cat.No.FLR-5041 N or approved 'equivalent make
CP brass 2 Way Bib Cock with wall flange of jaquar Cat. No. SOL-6041 for Paraplegic WC
CP brass Single lever Diverter concealed Body of Jaquar Cat. No. ALD-079 with Exposed Part kit of Jaquar Cat. No. FLR-5079 K and Spout with wall flange of Jaquar Cat. No. SPJ-5429 provision of Bath & Overhead Shower complete or approved equivalent make
C.P brass wash basin Pillar Cock single lever of 'FLORENTINE' of 'Jaquar' cat. No.FLR-5011N or 'approved equivalent make for substation.
CP brass Pillar Cock for washbasin of Jaquar Cat. No. 'SOL-6011 'or approved equivalent 'make for Paraplegic WC
C.P brass Angular Stop Cock with wall flange of Jaquar 'Florentine' Cat. No. FLR-5053N or approved 'equivalent make
CP brass Angular Stop Cock with wall flange of Jaguar Cat. No. SOL-6053 for Paraplegic WC
C.P Health Faucet with 8 mm dia 1.2 m long flexible tube & Wall Hook with N.R.V (Back Flow Preventer) of Jaquar Brand 'Allied' Cat. No. ALD-573 or approved equivalent make
Stainless steel dome shaped heavy quality waste 'coupling of 32 mm size, full threaded, for Urinal.
CP brass waste coupling 32 mm size with 80 mm height as per Jaquar cat. No. ALD-705/709 for wash 'basin
CP brass Shower and Arm with wall flange of Jaquar Cat. No. OHS-1789 and SHA- 477.
CP Bottle trap for washbasins , sink and urinals of Jaquar Cat. No. ALD-769B L 300X190.
CP Sink Cock of Jaquar Cat. No. FLR-5357ND/FLR5347ND or 'approved equivalent of Roca/ Toto make
CP brass Corner Glass Shelf (with bracket) of Jaquar Cat. No. ACN-1173
Providing and fixing the following C.P Brass Bathroom /toilet accessories of following make and fixing on the wall using CP brass screws, rawl plugs etc. as per manufacturer's requirement all complete at the locations
C.P. Brass Toilet paper Roll Holder of Jaquar 'Continental' Cat. No. ACN -1153N or approved 'equivalent make.
CP brass Soap Dispenser with Glass Bottle of Jaquar 'Cat. No. ACN-1135N or approved equivalent of Roca / Toto make
CP brass Soap Dish Holder of Jaquar Cat. No. ACN-1131N
CP brass single Towel Rail of Jaquar 'Continental' Cat. No. ACN - 1111BNM or approved equivalent.
C.P brass double coat hook as per 'Continental',Jaquar make Cat. No. ACN -1161N or approved equivalent make.
Supplying Stainless steel Sink of following size with or without Drain board, approved make, moulded out of 19 SWG (1 mm ) stainless steel sheet of grade AISI 304 (18/8) with waste coupling conforming to IS:13983, placing and fixing the Sink in position to correct line and level with basket type choke-stop strainer ( waste coupling ), Check nuts etc. including the cost of jointing materials, finishing the edges with white / matching colour cement as per manufacturer's recommendation all complete as per specification and as directed by EIC.
Stainless steel Sink 'Nirali- Elegance' with Drain board and with 'Glossy surface' of overall size 1145 x 510 mm ( Bowl size 560x410x200 mm )
TOTAL OF Part II-A : Sanitarywares & C.P Appurtenances.
Part-II- B : Water Supply System
Supplying & fixing on Exposed surfaces the following sizes uv-stabilized Chlorinated Poly Vinyl Chloride (CPVC) pipes & Fittings of specified class having thermal stability for both hot & cold water supply consisting following items of work:- i) Supplying CPVC pipes and all required CPVC plain and brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply of approved make conforming to IS:15778 with ISI mark for CPVC pipe having nominal size up to 50 mm and conforming to ASTM F 441 (IPS SERIES) Schedule 40 for CPVC pipe having nominal size 65 mm (2 ½”) and above. ii) Supplying & providingCPVC/GI flanges, any other required specials and other jointing materials for connecting the CPVC pipe lines with spool pieces of water tank and for connecting the CPVC pipe lines with any fittings & fixtures etc., of the water supply line iii) Laying and fixing the pipe and specials on exposed surfaces/ underground, to correct line, level and plumb for water supply line, using metal straps ( On wall surfaces ) at 1.00 mtr. interval or as directed by the EIC. iv) Jointing the pipes and Specials using Solvent cement conforming to IS:15225 & Teflon tape ( For threaded joins ) of approved makes including cutting the pipe to required size, preparation of surfaces, necessary tools etc. all complete. v) Cutting or making hole or chases in RCC or brick/block work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. vi) Testing the pipe line as per relevant code to a hydraulic pressure of 10 Kg / Sq.cm to assess leakages if any, rectifying the defect, retesting etc till water tightness of pipe line is ensured. vii) CPVC pipes and fittings/ specials shall be of same brand. NOTE: 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI/ CPVC/ PP-R pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings only. 3) Exposed pipe fixing arrangement include providing & fixing slotted G.I. section & U clamps bolts arrangement for grouping of pipe. Sloted section thickness should not be less than 2mm. Pipes and Fittings SDR-11 as per IS:15778
15 mm (1/2")n.size
20 mm (3/4")n.size
25 mm (1")n.size
32 mm (1¼")n.size
40 mm (1½")n.size
50 mm(2") n.size
65 mm (2½")n.size
80 mm (3") n.size
Supplying, fixing & concealing on wall / beams / columns etc. the following sizes UV- stabilised Chlorinated PolyVinyl Chloride (CPVC) Pipes & (male / female) brass threaded fittings Fittings of specified class having thermal suitable for both hot & cold water supply & suitable for fixing various fittings & fixtures such as taps, jet sray, wall mixture, concealed stop cock, flush valves etc., consisting following items of work :- i) Supplying CPVC pipes and all required CPVC plain/ and brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply of approved make conforming to IS:15778 with ISI mark for CPVC pipe having nominal size up to 50 mm and conforming to ASTM F 441 (IPS SERIES) Schedule 40 for CPVC pipe having nominal size 65 mm (2 ½”) and above. ii) Laying and concealing the pipe and specials for water supply by cutting/ making 75 mm X 75 mm groove on the wall, fixing the pipe using metal straps wherever required and filling the groove with cement mortar mixed with water proofing compound, after laying and testing the pipe line including making leak proof joints using cement solvent/ Teflon tape ( For threaded fittings) of approved make, cutting the pipe to required length, preparation of surface, necessary tools etc. all complete. iii) Cutting or making hole or chases in RCC or brick/block work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. iv) Testing the pipe line as per relevant code to a hydraulic pressure of 10 Kg / Sq.cm to assess leakages if any, rectifying the defect, retesting etc till water tightness of pipe line is ensured. v) CPVC pipes and fittings/ specials shall be of same brand. NOTE:- 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI/ PP-R/ CPVC pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings only. 3) All concealed cPVC pipes provided for PH work shall be measured under this item Pipes and Fittings SDR-11 as per IS:15778
15 mm (1/2") n.size
20 mm(¾") n.size
25 mm (1")n.size
32 mm (1¼")n.size
40 mm (1½")n.size
50 mm size
Providing, instaling, fixing, connecting, testing 75 micron Super Flow-screen filter, of M/s. Jain Irrigation Systems Ltd., of following Model Nos, fitted with pressure gauge, water drain and emptying plug. etc all as per specifications, Drawings and as directed by EIC. Note: 1. Threaded fittings of CPVC shall be of Brass Threaded only. Brass threaded CPVC fittings will be measured and paid under relavent item 2. All Super Flow Plus filter provided for PH work will be measured under this item
DJPSFP50SW, Max. working pressure = 10 kg/cm², Flow rate = 50 m³/hr, Inlet/Outlet Connection = 3"
Providing and Fixing Ball Valve as per relevant IS suitable for pipe pressure class with body of bronze and ball & stem of Stainless Steel of approved make with fittings & material for conectivity and labour, making water proof joints, including cost of jointing material and CPVC specials if required & testing the joints. etc complete as per directions of engineer-in-charge. NOTE: 1) Item Includes Flange jointing with required new flanges and hardware. 2) Wherever required union joint shall be provided in pipe to facilitate removal of valve. 3) Threaded fittings of CPVC shall be of Brass Threaded only. Brass threaded CPVC fittings will be measured and paid under relavent item. 4) All bronze ball valves provided for PH work will be measured under this item.
15 mm (1/2")n.size
20 mm (3/4")n.size
25 mm (1")n.size
32 mm (1¼")n.size
40 mm (1½")n.size
50 mm(2") n.size
65 mm (2½") n.size
80 mm(3") n.size
Providing & fixing and Jointing to pipe work of following dia. Cast Iron / Spheroidal Graphite (SG) Iron D/F PN 1.0 class Sluice valve of approved Make with IS mark & as per IS 14846 : 2000 (including all hardware and packing) water works quality, having non-rising spindle with hand wheel, spindle of stainless steel as per requirement, testing the joints and valves to a hydraulic pressure as mentioned all as per the specification and as directed, Including fixing of structural steel if required.
65 mm for 73.02 NB cPVC, ASTM Pipe ( Sch.40).
80 mm for 88.9 NB cPVC, ASTM pipe (Sch.40).
Providing high pressure "HP" following size Float Valve assembly (horizontal plunger type ) conforming to IS 1703 with brass or gun metal piston, back nut and PVC float conforming to IS:9762, fixing to inlet pipe of water tank and making water proof joints including the cost of jointing materials and CPVC/ G.I specials, if required, testing the joints as per I.S. recommendations all complete as per specification and as directed.
50 mm dia.
Supplying & fixing following size C.P brass Coupling with approved quality C.P brass Mosquito proof jalli including providing CPVC/ GI connector, bend and any other CPVC/ GI specials, if required for fixing the coupling, jointing materials such as tefflon tapes, spun yarn, white zinc, fixing the same to GI/CPVC pipes etc. complete as specified & directed for overflow / vent pipe of water tank.
50 mm dia.
25 mm dia.
Supplying & fixing following Stainless Steel (grade 316) spool pieces of required diameter having flange on one / both end with flange holes in flanges for fixing with nut & bolts (OR) with screwed ends on both/ one end as per site requirement and as directed by the Engineer in charge , having 450 mm/ required length, providing 3D x 3D (where D is the outer diameter of pipe) and 4 mm thick stainless steel puddle plate (minimum size 150mmx 150mm) welded to it including cutting the plate to required shape and fixing in the reinforcement at the center of RCC wall / slab at required level, height etc including cutting the form work provided for casting concrete etc., Complete all as per specifications and as directed by Engineer-in-Charge. Note:- actual weight of spool piece only will be measured for payment and no payment will be made for any wastages.
40 mm to 450 mm dia
Construction of brick masonry valve chambers of following dimensions for depth as mentioned below comprising of 230 mm thick brick masonry in cement mortar 1:4 over a bed of 150 mm thick cement concrete of grade 1:2:4 for foundation with 150 mm offset all round, including racking out joints & plastering in cement mortar 1:3, 20 mm thick both on internal and external surfaces, internal surfaces finished smooth with a floating coat of neat cement, Fixing (FRP/GRP) Frame and cover of approved make all as per specifications and directions of the E.I.C. including dewatering the pit, if required till completion of the work all complete.
Chamber measuring 0.60 mtr. X 0.60 mtr. for an initial depth of 600 mm (Clear internal dimension)
Providing GRP/FRP composite Mosquito proof hinged cover with frame for Overhead Water Tank (Having loading capacity not less than 300 Kg) of 'EVERLAST' having suitable locking arrangement for Manhole opening of water tank, fixing the cover by providing corrosion resistant studs, nuts, built-in hold fasts etc. by chasing or cutting holes and grouting with cement mortar 1:1 by adding approved water proofing compound @ 2% by weight of cement, all complete as per specification and as directed by EIC.
530 mm dia.
TOTAL of Part-II- B : Water Supply System
Part-II-C : Drainage System
Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, anti syphonage, HVAC waste pipe and rain water pipe lines consisting following items of work:- i) Providing and fixing uPVC UV-Stabilised Soil / waste pipe as per IS:13592 and IS:14735 Type-B laid in floor & on Exposed faces of wall of approved make ii) Fixing the pipeline vertically by Metal clamps with rubber seal of approved make. iii) Fixing the pipeline Horizontaly with specified slope below the ceiling by Metal clamps with rubber seal and GI hanger rods not less than 5mm dia at specified spacing, including all required hardware. iv) Providing and fixing uPVC cowl at the top of soil,waste water & vent pipe line. v) Providing and fixing uPVC P/S trap on line as per requirement for soil,waste water pipeline. vi) Laying the pipe below floor / ground to the slope and gradient equal to (or) steeper than 1 in 50, making leak proof connections of soil /waste pipe line from the shaft with inspection chamber / Manhole / Gully trap Chamber including the cost of filling around the holes of inspection chamber / Manhole / Gully trap with cement mortar 1:1 mixed with water proofing compound vii) Jointing the pipe / fittings with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Carrying out water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at concealed locations. viii) Cutting the pipe to the required length including providing short pieces, necessary connectors, fittings & specials with & without door, assorted fittings such as plugs, tees, couplers, reducers, cross tees, reducing tees, elbows, bends, single & double Y, vent cowl,gaskets, offsets etc. Including providing necessary clean outs, cleaning pipe, extension pipe if any for clean outs, door bend, door elbow, door Y, socket plug, etc wherever required for accessing every segment of soil and waste pipes to enable removal of any Chock up after installation. ix) providing necessary specials for connecting UPVC SWR (IS:13592/ IS:14735) pipe with UPVC (IS:4985) pipe etc x) Dewatering the pit/ trenches if necessary till completion of work xi) Testing the pipe line for any leakages, rectifying the leakages if any, retesting etc., till water tightness of the pipe line is ensured xii)Exposed pipe fixing arrangement include slotted G.I. section and U clamps. Note: Earthwork excavation for trenches shall be paid under relevant items ) For Soil & waste and Vent pipe lines
50 mm dia.
75 mm dia.
110 mm dia.
160 mm dia.
Supplying, fixing & concealing on walls/ beams/ floors columns etc. the following sizes uPVC Pipes & Fittings of specified class consisting following items of work:- i) Supplying uPVC pipes conforming to IS:4985 and uPVC moulded plain / threaded fittings conforming to IS:7834 for waste water pipe line of approved make with ISI mark / equivalent approvals as per relevant standards, providing necessary specials for connecting UPVC (IS:4985) pipe with UPVC SWR (IS:13592) pipe etc. ii) Laying and concealing the pipe and specials for waste water by cutting/ making 75 mm X 75 mm groove on the wall, fixing the pipe using metal straps wherever required and filling the groove with cement mortar 1:3 mixed with water proofing compound, after laying and testing the pipe line including making leak proof joints using cement solvent/ Teflon tape ( Forthreaded fittings) of approved make, cutting the pipe to required length, preparation of surface, necessary tools etc. all complete. iii) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition (No Chases in RCC wall, column, beam, slab, chajja,etc shall be made with out getting the permission from Engineer In charge & structural design Enginner) iv) Concealing the pipes in wall, Laying the pipe below floor/ ground to the slope and gradient equal to (or) steeper than 1 in 50 v) Testing the pipe line for any leakages, rectifying the leakages if any, retesting etc., till water tightness of the pipe line is ensured. For Urinal/ wash basin/ Anti syphonic/ Sink waste. (10kg Pressure)
Providing uPVC Floor Trap / Nahani Trap of following size having not less than 40 mm effective water seal, fixing the trap in position and connecting with waste water pipe by cement solvent / as per manufacturer's recommandation, embedding the trap in cement concrete 1:2:4 to correct level and gradient, providing and fixing 200 x 200 mm size top tile with central strainer & flat cover / flush strainer, closing the side inletes with plugs if required etc.complete all as per specification and as directed by the Engineer in charge.
Multifloor trap of 110 x 75 x 50 size of approved make with 3 pc top tile & flush strainer, mat finish.
Providing and fixing HDPE sheet flashing fabricated by welding HDPE flexible sheet with 160 / 110 mm dia HDPE pipe about 400mm long for PVC rain water pipes, fixing the same on RCC/cement concrete surface using approved synthetic glue, covering the HDPE sheet wateright with cement mortar 1:2 mixed with water proofing compound and forming the proper shape and grade and finishing with inlet mouth of rain water pipe, cutting RCC slab or wall if required, including the cost of bitumen, cement mortar etc. complete all as per specification and as directed by the Engineer-in-charge. NOTE: HDPE sheet flashing shall be sticked watertight over RCC / Cement Concrete surface by using approved synthetic glue as per manufacturers recommendation and as directed by the Engineer incharge. After fixing HDPE sheet flashing over RCC/ Cement concrete surface, the top potion of HDPE sheet flashing shall be spread with approved synthetic glue, fine (0.5 mm size) sand shall be sprinkled over it immeadiately, allowed to be dried and after drying it is to be covered watertight with cement mortar1:2 mixed with waterproofing compound @ 2% by weight of cement as per required shape and form. Item includes providing 160x110 mm uPVC reducer.
450 x 450 mm size HDPE sheet Flashing fabricated from 8 mm thick HDPE sheet and PN 6 grade 160mm /110 mm dia HDPE pipe.
Providing and fixing Stainless steel Dome mesh fabricated by welding from 2mm dia 304 grade stainless steel wire for PVC rain water pipes (sheet flashings), with 5mm x 10mm L base ring of 0.5mm thickness 304 grade Stainless steel. L ring to be embedded in waterproofing & dome to be placed on it, including the cost of fixing material etc. all complete as specified and as directed by the E.I.C.
Half Spherical Dome having opening 5 to 10 mm of 160 mm ID
Constructing brick masonry Gully Trap chamber of following size and upto 600 mm initial depth including providing and fixing gully trap, consisting following items of work:- i) Providing square mouth uPVC gully trap of size 150 X 150 mm with 110 mm outlet of Approved Make embedding in position in cement concrete 1:2:4 inside the chamber. ii) 230 mm thick brick masonry in 1:4 cement mortar over 150 mm thick cement concrete 1:2:4. iii) 15 mm thick plaster in cement mortar 1:3 on internal and external surfaces, internal surfaces and top finished with a floating coat of neat cement. iv) Providing and fixing precast approved make (EVERLAST) Composite (FRP/GRP) Manhole covers & frame of size 300mm x 300mm as approved by E.I.C having point loading capacity not less than 0.3 tonne with name of department and year engraved as specified / approved, including cost of necessary hardware and cement concrete / mortar for fixing the frame.
300 X 300 mm size Gully Trap chamber.
Providing & laying UPVC under ground drainage pipes & Fittings of Approved make for storm water drains & Sewer lines of following size conforming to IS:15328 to proper level & grade, jointing including prviding coupler with solvent cement / welded joints / as per manufacturer's requirement, encasing the pipe alround using cement concrete 1:3:6 complete if required all as per specifictions, drawing and as directed by the E.I.C. item includes Providing and fixing UPVC fittings such as Bendes, Tees & Y, Reducers, Blanking Plugs, Couplers, Adaptors etc NOTE:-Cement concrete for encasing shall be paid under relevant item For Sewer line and Storm water Drains
110 mm DN (SN 8kN/m²-SDR34)
160 mm DN (SN 8kN/m²-SDR34)
Cement concrete of specified grades at all locations & depths for the following works using graded stone aggregate of 20mm. maximum size including necessary form work, machine mixing, transporting, placing in position consolidation, finishing, curing etc. complete as per specifications, drawings & as directed by the EIC.
PCC 1:3:6 in bed concrete, pedestal, encasing etc.
PCC 1:2:4 in bed concrete, pedestal, encasing etc.
NOTE FOR INSPECTION CHAMBER & MANHOLE i) Depth of Inspection chamber shall be the vertical distance from the top of the frame & cover of manhole/ chamber to the outgoing invert of the main drain channel. ii) The internal diameter/ sizes of inspection chambers & manholes mentioned in the item shall be measured from finished plastered surfaces. iii) The cost of 1:2:4 grade concrete and plastering with CM 1:2 for fixing frame & cover is included under the scope of work of item for providing Everlast Cover iv) Slope of 1:6 for benching shall be started from channel of depth equal of the outgoing sewer diameter. v) The slope of conical wall of manhole and longitudinal walls of rectangular Inspection Chamber starts from the vertical height of 200mm from top of frame and cover. vi) While making payment for extra over initial depth, the thickness of RCC frame & cover and the thickness of cement concrete bed block (bearing course) shall not be deducted from the depth of manhole or chamber. Constructing brick masonry Inspection chambers of internal sizes 900 X 600mm at bottom and 900 X 450mm at top for an initial depth of 600mm consisting following items of work. i) 230 mm thick brick masonry in cement mortar 1:2 over 150 mm thick bed in cement concrete of grade 1:2:4 with 150 mm offset all-around, tapering of longitudinal walls starting from the height of 450 mm from the top of chamber frame & cover and tapering of longitudinal walls ending at the height of 200 mm from the top of frame & Cover to obtain an internal dimensionof 900 X 450mm at 200 mm from top of chamber. ii) 20 mm thick plaster in cement mortar 1:1 mixed with water proofing compound @ 2% by weight of cement on internal and external surfaces, internal surfaces and top finished with a floating coat of neat cement. iii) Making benching and haunching in cement concrete of grade 1:2:4 and finishing with floating coat of neat cement. iv) Fixing frame and cover at top using cement concrete of grade 1:2:4 (for bed block / bearing course and capping) and cast iron steps / foot rests, all as per specification and as directed by Engineer in charge. NOTE: i) Providing & fixing foot-rests/ steps and CI/ RCC/ Composite frame & cover including CC of grade 1:2:4 & C.M 1:2 plaster for fixing the frame and cover, will be paid under relevant item/ included in other relevant item. ii) Additional depth of chamber will be measured in cm and paid as per actual depth.
Inspection chamber of internal sizes 900 X 600 mm at bottom and 900 X 450 mm at top for an initial depth of 600 mm.
Extra over above item for additional depth of inspection chamber beyond 600 mm initial depth & upto a depth of 1800 mm. all as per specification and as directed.
Construction of circular manhole of 1200 mm internal diameter at bottom and 530/ 560/ 600mm at top for 1.5m initial depth & brick masonry in 1:2 cement mortar, 230 mm thick wall for 1400mm measured from top of frame & cover of manhole in conical shape and remaining height constructed 345 mm thick in cylindrical shape over a 300 mm thick cement concrete bed of grade 1:2:4 with 300 mm offset from outer finished wall surface of the manhole, also for benching and fixing frame & cover at top of brick masonry i.e. below and around frame and cover for bed block (bearing course) and capping including providing and fixing frame & cover, CI steps, 20mm thick plaster in 1:1 cement mortar mixed with water proofing compound @ 2% by weight of cement as per specifications, drawings and as directed by EIC. NOTE: i) Providing & fixing foot-rests / steps and CI / RCC / Composite frame & cover including CC of grade 1:2:4 for fixing the frame and cover, plastering in C.M 1:2 on exposed surfaces of bed block & capping,making smooth cement finish etc. will be paid under relevant item.
Top internal dia 530 / 560 mm to suit MD,HD & EHD cover
Extra over above item for additional depth of Chamber upto 3m
Providing & fixing precast approved brand (EVERLAST) Composite Manhole covers as approved by Competant athority / E.I.C tested as per IS:1726, including cost of necessary hardware, 1:2:4 grade concrete for fixing frame, bed block (bearing course) and capping including necessary form work and CM 1:2 mortar for fixing the frame & for plastering exposed surfaces of concrete bed block (bearing course) and capping finished smooth with floating coat of neat cement etc., complete as per specifications, drawings and as directed by the E.I.C. NOTE: Shade and Colour and design pattern to be get approved from Engineer-in-Charge.
Rectangular Heavy duty (Grade HD - 20 designation as per IS:1726) frame and cover size 910 x 450mm
Circular Heavy duty (Grade HD-20 Designation as per IS:1726) frame and cover clear internal dia. 530mm
Square Heavy duty (Grade HD - 20 designation as per IS:1726) frame and cover size 600 x 600mm for Valve Chamers
Square Heavy duty (Grade HD - 20 designation as per IS:1726) frame and cover suitable for 300 x 300mm (Clear) valve chambers/Gully trap chambers/drop cleaning chambers etc.
Making new sewer connection with the existing manhole, which consist of making hole in the existing manhole with out causing any damage to the existing manhole, finishing the hole with cement mortar 1.1 (mixed with waterproofing compound) to the original condition after connecting the new sewer line to the existing manhole, disposing off the debris at directed place up to a lead of 150 metre all as per specifications and as directed by EIC.
160 mm nominal dia. pipe
Providing copolymer polypropylene steel reinforced plastic Foot-rests / Steps of Patel brand or eq. as per ASTM D - 4101 specification and moulded a 12 mm dia. IS - 1786 grade Fe - 415 steel reinforcing bar and in "U" shape having dimensions 263 x 168 mm and fixing in concrete / wall as shown in the drawing and as directed all complete. Note: All Foot-rests provided for PH work will be measured under this item
TOTAL OF Part-II-C : Drainage System
Description of Work / Item(s)
Amount
ABSTRACT OF PART - III
PART - III - ELECTRICAL WORKS
Section-I- Main SMDB
Section-II-fabricated Distribution Boards(MDB)
Section-III- LT Cables & End joints
Section-IV- Readymade Distribution Boards (DB)
Section-V- Point wiring & Submain wiring
Section-VI- Maintenance Free Earthing
Section-VII- Telephone System
Section-VIII- LAN System
Section-IX- Fire Alarm System
Section-X- Lightning Protection System
Section-XI- Emergency Voice Evacuation System
Section-XII-T. V. System
Section-XIII-Miscellaneous Items
Section-XIV-LED Luminaires, Ceiling fans etc.
Section-XV-Rooftop Solar PV System
Description of Work / Item(s)
Amount
Part III : Electrical WORKS
SECTION-I : Main Distribution Board (SMDB): LT PANEL: Supply, installation,testing & commissioning of totally type tested/design verified assembly, front operated front access cubicle, totally enclosed, IP42, indoor type, wall mounted with hinged and lockable doors MDB including inter connections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3 phase 4 wire 50 Hz system, and to with stand a fault level of 25KA symmetrical for 1 sec at 415V complete as per specifications, as required and as below .All SMDB shall have provision for entry of cables from the top/ bottom/sides as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof.The bus bars shall be insulated with heat shrinkable sleeves & color coaded. SMC/DMC shrouds and busbar supports shall be used. Note: 1)All G.A. & fabrication drawings,single line diagram, control schemes shall be got approved from the E.I.C. Necessary touch up may be done at site, incase if required. 2) All non current carrying metallic parts of the equipment shall be earthed with copper flexible wire / strip of adequate size. 3) All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. 4) Cable entry boxes,corner box, metering box etc shall be included in the scope of work. 5) MCCB shall be provided with spreader links.
Main SMDB Incomer : 1 no. 315 A, 25 kA, 415 volt 3P+N MCCB with microprocessor based O/C+S/C+ Earth fault release comprising of following: i) 3 nos cast resin current transformer of 300/5 ratio class 1.0 for metering,5 VA Burden. ii)RYB LED type indicating lamps - 1 set iii) Multifunction meter, 3 phase 4 wire, CT sec. 5A, Class-1, flush mounting size 96x96 mm indicating V, I,F,PF,Power & Energy etc. -1 no. Outgoings :- 12 Nos. 32A to 100 A 3P+N, 25KA MCCB complete with thermal magnetic release having over current & short circuit protection
TOTAL OF SECTION-I : MAIN SMDB WORKS
SECTION-II : Fabricated Distribution Boards(MDB) :
Fabricated Distribution Boards(MDB) : Supply,installation,testing & commissioning of Main distribution board IP 42, surface mounted type/ floormounted with concealed hinges fabricated out of min 16SWG thick MS CRCA sheet complete with 40 X 40 X 5mmMS angle iron frame work, supports, accessories,interconnections, earthing, locking arrangement, wire waybox, cable entry box with gland & gland earthing, metal treatment (Seven tank process) painting, 2 nos 10mm dia 32 mm long brass earthing, studs, enameled danger boardname plate, neoprene gasket, all required & as per instruction of E-I-C. Note: 1)The MCCBs shall be provided with microprocessor based overcurrent , short circuit & earth fault release. 2)MCCBs shall be of minimum 25 KA Ics breaking capacity. 3)All MDBs shall be provided with RYB indication lamps (heavy duty LED cluster type) with HRC protection fuses.
Rooftop Solar PV MDB a)63A MCCB 4 Pole, 25 kA, with extended rotary handle-1no. b) RYB indication lamp - 1 Set c) 63/5 A ratio, class-1, 5VA burden cast resin current transformer - 3 Nos. d) Multifunction meter, 3 phase 4 wire, CT sec. 5A, Class-1, flush mounting size 96x96 mm indicating V, I,F,PF,Power & Energy etc.-1 no.
TOTAL OF SECTION-II : MDB WORKS
SECTION-III : LT CABLES & END JOINTS :
L.T Cables: Supply, installation, testing & commissioning of 1.1 KV grade aluminium/ Cu stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2)outer sheathed cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, fixed on wall/column/slab/falseceiling / existing cable tray /existing hume pipe/trench/shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles and saddles or in ground, sand bedding laying of baked bricks on side & top-, temporary reinstatement, back filling, dewatering, consolidation,disposal of excess earth within the radius of 500 m andmaking good to the original finish etc providing Al cabletag as per enclosed detailed specifications, drawings & asper instructions of the E-I-C & of the following sizes. Note: 1) Excavation of earth shall be measured under item No. 320 of Section XIII Miscellaneous item. 2) Sealing of hume pipes with wooden bushes after cable laying shall be included in the scope of work. 3) Clamping of cables on trays including supply of clamping materials as per instruction of EIC shall be included in the scope of work.
3.5C x 70 Sq.mm Al. conductor cable
4C x 10 Sq.mm Al. conductor cable
3C x 2.5 sqmm Cu Conductor cable
LT Cables End Joints End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket,double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to thenearest earthing bus terminals as per the drawings,specifications and as per the instructions of the Engineer-in-charge.
3.5C x 70 Sq.mm Al. conductor cable
4C x 10 Sq.mm Al. conductor cable
3C x 2.5 sqmm Cu Conductor cable
TOTAL OF SECTION-III : LT CABLES & END JOINTS
SECTION-IV : Readymade Distribution Board : Supply, installation, testing & commissioning of following readymade distribution boards, double door, IP 42 degree protection complete with necessary, MCB isolators , MCBs,earth leakage circuit breaker (ELCB) etc including interconnections with appropriate capacity size of PVC insulated copper conductor wires (ISI marked),suitable for concealed mounting /wall mounting with MS frame workof 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated out of min 18 SWG /20SWG thick M.S. CRCA sheet as per manufacturers standard, with concealed hinged door, locking arrangement etc. including earthing clamps for both incoming & outgoing circuits interconnections, per phase isolation kit as required, cable end box & wire way box if required, continuous copperearth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coated painting, Phase Distribution drawing etc. all as per drawings (G.A. & fabrication drawing to be got approved) etc. relevant IS & instruction of Engineer-in-charge. Note: 1.MCBs (Type –C) shall be minimum 10 KA breaking capacity, as specified. 2. Blanking Plates shall be included in scope of work. 3. DB shall be of standard readymade type from approved manufacturers as indicated in preferred makes of material.
VTPN Emergency SMDB : a) 100 A , FP MCCB - 1 No. b) 63/40 A ,TP MCB -10 Nos. c) 25A DP MCB- 2 nos. d) 12 way brass neutral link -- 2 set
VTPN MDB : (MDB-1 to 3) a) 100 A , TP MCCB - 1 No. b) 63/40 A ,TP MCB -8 Nos. c) 12 way brass neutral link -- 2 set
ETPN DB : (LDB 1 to 3, ELDB 1 to 3, Staircase & corridor light DB) a) 40A TP MCB -- 1 No. b) 25A DP ELCB with 30mA sensitivity -- 3 nos c) 6-32A SP MCB -- 18 nos d) 8 way brass neutral link -- 4 set
ETPN DB : (PDB-1 to 6, EPDB-1 to 4 & ACDB-1 to 5) a) 63 A, TP MCB - 1 No. b) 40A DP ELCB with 30mA sensitivity -- 3 nos c) 6-32A SP MCB -- 18 nos d) 8 way brass neutral link -- 4 set
ETPN DB : (For Kitchen) a)63A TP MCB (D-type) -- 1 No. b) 40 A DP ELCB with 30mA sensitivity -- 3 nos c) 6-32A SP MCB (D-type) -- 18 nos d) 8 way brass neutral link -- 4 set
SPDB with acrylic door : (Security lighting) a) 16 A DP MCB -- 1 No. b) 16A, 240V, 50Hz, 2 output digital astronomical time switch-- 1 no
FP Change over switch enclosure Supply, Installation, Testing & Commissioning of following FP changeover switch with readymade metal enclosure with angle iron framework including minor civil work to fix on wall etc complete and all necessary components included (Security DB and Staircase & escape light DB)
40A, FP-two way with centre off-415V changeover switch (Master switchs) for corridor & staircase lighting
TOTAL OF SECTION-IV : READYMADE DB WORKS
Section-V: Point wiring and Submain wiring
Point wiring in PVC (HMS variety) conduits : Point wiring for light/ceiing fan/6A/ 16A/ socket outlet/6A outlet for exhaust fan , bell point etc. with 1.1 KV grade FRLS PVC insulated multi stranded copper conductor wire(ISI marked), in existing floor raceway/ 25 to 40 mmdia High mechanical stress (HMS) rigid PVC conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm.thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 0.9mm G.I. Saddles, ready made MS switch boxes & socketoutlet boxes of nominal 1.2 mm thickness , brass earthingstud 1/2 nos, controlling modular switches, sockets with moulded front plate and inner plate etc. including appropriate size of FRLS PVC insulated copper earth wire ,brass/bakelite (straight / angular) lamp holders, 3 plateceiling rose,6 A, connectors, painting etc. as per specifications and drawings and as per instructions of E-I-C and as detailed below : (sample switch Box etc. to be got approved before fabrication) NOTE: 1. Connections shall be done with crimped type tinned copper lugs & washers. 2. All switches & socket outlets shall be as per preferred makes. 3. All sample boxes with accessories /luminaires shall be got approved from Department. 4. All 16 A socket outlets should be with 6 pin type 5. MS boxes other than switch boxes & socket outlet boxes shall be fabricated out of minimum 1.5mm thick MS sheet duly painted with red oxide primer & 2 coats of epoxy paint 6. Minimum size of the FRLS insulated copper earth continuity wire shall be 2.5 sq.mm. 7. The colour shade of switches shall be white /off white.For socket outlet points/switch boards on normal powersupply, the cover plate shall be white/off white colour,graphite grey (RAL 7024) or other shade as per instruction of EIC, for socket outlet points/switch boards on DG power supply. 8. The scope also includes supply of modular blanking plates where ever required. 9. The maximum permissible number of FRLS insulated wires through PVC/MS conduits shall be as per technical specifications. 10. The point wiring shall generally be concealed type only, except in lift shaft/ Elect. Shaft/ Basement areas/ in RCC retaining wall/ in dry well/ above false ceiling & wherever concealed wiring is not feasible, as per instructions of E.I.C supply.
Primary Light point with 2 nos. 1.5 sq.mm wires & 1 No. 2.5 sqmm earth wire with 6A switch
On nomal power supply
On DG power supply
Secondary light point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looped to above item 306.01
On nomal power supply
On DG power supply
Primary Light point with 2 nos. 1.5 sq.mm wires & 1 No.2.5 sqmm earth wire with 'Two way' 6A switch (Staircase lights) (On DG power supply)
Secondary light point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looped to above item 306.03 (Staircase lights) (On DG power supply)
Primary Light point with 2 nos. 2.5 sq.mm wires & 1 No. 2.5 sqmm earth wire with 16A switch (Flood lights) on DG power
Secondary light point with 2 nos of 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looped to above item 306.05
3 nos.6A/10A/13A multistandard socket points with 2 nos of 2.5 sq.mm wires along with 1 no of 2.5 sq.mm insulated earth wires, looping with 1.5 sqmm + 2.5 sqmm wires (forearth) & independent 13A switches.
On nomal power supply
On DG power supply
6A/10A/ 13A multistandard socket with 1 no. of 1.5 sq.mm wires along with 1 no of 2.5 sq.mm insulated earthwires on ceiling and directly controlled from DB (Flykill indining areas) (On nomal power supply)
16 A 6 pin socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire complete with 16 A switch in one box
On nomal power supply
On DG power supply
16 A 6 pin socket outlet point on ceiling with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire with 16 A switch in on nearest switch board ( Class room)(On DG power supply)
6 A + 16 A (6 pin) socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire & looping with 1.5 sqmm + 2.5 sqmm wires complete within dependent 6A and 16 A SP switches in one box. (On nomal power supply)
6A socket point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires & 6A switch on switchboard.
Point wiring for single phase exhaust fan with 1.5 sq.mm phase wires & 2.5 sqmm earth wire & with ceiling rose near exhaust fan & controlling 6 A , 240 V SP switch on nearest switchboard.
Point wiring for single phase exhaust fan (300mm dia) with 2.5 sq.mm phase wires & 2.5 sqmm earth wire & with ceiling rose near exhaust fan & controlling 16 A , 240 V SP switch on nearest switchboard for kitchen and Electrical room
Point wiring with 4 sq.mm wire and 2.5 sq.mm insulated earth wire complete with 25 A 3pin socket outlet with plug(Industrial Type) near split AC unit & 25A DP MCB at operating height on wall, in readymade powder coated MSCRCA box with MS cover and with necessary cutouts,interconnections earthing stud etc . MCB shall be with 10KA breaking capacity.
Point wiring with 4 sq.mm wire and 2.5 sq.mm insulated earth wire complete with 25 A 3pin socket outlet with plug(Industrial Type) & 25A DP MCB on wall, in readymade powder coated MS CRCA box with MS cover and with necessary cutouts, interconnections earthing stud etc .MCB shall be with 10 KA breaking capacity.
Point wiring with 6 sq.mm wire and 4 sq.mm insulated earth wire complete with 32 A 5pin socket outlet with plug(Industrial Type) & 32A TP MCB(D type) on wall, in ready made powder coated MS CRCA box with MS cover and with necessary cutouts, interconnections earthing stud etc MCB shall be with 10 KA breaking capacity(kitchen)
Ceiling fan points with 1.5 sq.mm wires and with 2.5 sq.mm insulated earth wire complete with 6A, 240V, SP switch without regulator.
On nomal power supply
On DG power supply
6A socket point on the ceiling with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires & directly controlled from DB (For emergency lights onbattery backup)
Water heater point with 4 sq.mm + 2.5 sq.mm insulated earth wires , 32 A DP MCB type isolator (non tripping type) in MS box near door at suitable position , 30A 3 way connector block mounted in MS box near heater
SUBMAIN WIRING :- Supply, installation testing & commissioning of 1100 VFRLS grade PVC insulated multistranded aluminium conductor wires of the following sizes with necessary leads at both sides in 25mm/ 32mm/ mm/40mm dia PVC (HMS) or MS conduit concealed in wall/beam/ slab/column or onsurface of wall/beam/slab/ column on 5 mm thick G.I spacer and 20 SWG GI saddle, MS pull out boxes , junction boxes of suitable sizes as per site requirement, from MDB to individual DB including connection with copper lugs etcas per specifications and as per the instruction of Engineer-in-charge. Note: 1. Connections shall be done with crimped type tinned copper lugs. 2. All embeded conduit junction boxes/ pull boxes shall be covered by 18 SWG thick M S sheet covers painted white projecting atleast 5mm around finished opening fixed to box with CSK machine screws.
4 nos. of 6 sq.mm & 1 no. of 4 sq mm copper wire in 40mm dia PVC (HMS variety) or MS conduit with necessary pull out boxes, junction boxes etc including end temination at both the ends with additional loop wire of 0.5 m length at either ends.
2 nos. of 4 sq.mm & 1 no. of 2.5 sq mm copper wire in 40mm dia PVC (HMS variety) or MS conduit with necessary pull out boxes, junction boxes etc including end temination at both the ends with additional loop wire of 0.5 m length at either ends.
TOTAL OF SECTION-V : POINT WIRING & SUBMAIN WIRING
SECTION -VI: MAINTENANCE FREE EARTHING SYSTEM
MAINTENANCE FREE EARTHING SYSTEM : Supply, installation, testing & commissioning of maintenance free earthing system & associated works, etc. complete as per specifications & instructions of E-I-C. NOTE: Measurement of resistance of earthing grid must be carried out as per instructions of EIC. 2) All type of excavation shall be measured under item no. 320 of Section -XIII Miscellaneous item.
Providing and making earth station comprising of 17 mmdia 3m long earthing electrode of high tensile low carbon steel rod molecularly bonded 250 micron copper coating on the outer surface, UL listed, filling bore with suitable earth enhancement compound as per IEC 62561-7 & manufacturer's standard, surrounding the earth electrode complete with all required materials & instructions of EIC.(Body-2, Solar-2, LPS-6) Note: The scope includes :- 1) Installation of earth rods including making pit/ drilling 150 mm dia, 3m deep bore holes in normal soil/ hard rock as per manufacturer's recommendations & design. 2) Exothermic welding of joints between earth electrode & GI / tinned Cu strip and between GI / tinned Cu strips, used for interconnection of earth electrodes. 3) Each earth electrode shall be provided with poly plastic inspection chamber with cover as per OEM standard.
Supply & installation of 50x6mm & 150 mm long tinned Cu equipotential bar inside concrete chamber (600 x 600 x 600 mm) as per instructions of EIC. Note: 1) The date of testing and earth resistance value shall be written on the cover with black base with yellow paint. 2) The concrete chamber shall be included in Civil relevent item
Supply & installation of discharge gap device with parallel connected surge voltage protector to couple different earthing system similar to M/S OBO make FS-V20 or equivalent in fibreglass reinforced polyester enclosure IP65 & IK08 of size 200 (H) x 250 (W) x 115(D) mm similar to M/s.Spelsberg Cat No.Abox-I 250. Note: 1) The enclosure housing discharge gap device shall beinstalled in concrete chamber housing equipotential bar. 2) The scope includes interconnection of equipotential barsof lightning & body earthing with suitable size flexible Cuconductor with bimetallic lug at one end as per site &instructions of EIC.
G.I / tinned Cu earth wire/earth strip fixed on wall/side of trench/slab /column /beam/ shaft connection topanel/DBs/SFU's etc. with 5mm thick G.I. Spacers & 2mm thick G.I. Saddle or in ground at 500 mm below with earth enhancing material surrounding the strip, including excavation in ground, refilling & removal of excess earthwithin a radius of 500 m, temporary in statement & backfilling of trench, consolidation, painting with two coats of black bituminous paint for earth wire/ strip in ground &green enamel paint for earth wire /strip on surface etc.
25 X 6 mm tinned copper strip
25 X 3 mm tinned copper strip
4 SWG tinned Cu earth wire
8 SWG tinned Cu earth wire
TOTAL OF SECTION -VI : MAINTENANCE FREE EARTHING WORKS
SECTION-VII: TELEPHONE SYSTEM
Telephone Point Wiring: Point wiring with 4 pair CAT-6 wires copper conductor PVC insulated, in 25-40 mm dia rigid PVC conduit (HMS variety - ISI marked,conforming to IS 9537 Part-III) concealed in slab /wall or surface with 5mm thick G.I.spacer & 20 SWG GI Saddle fixed with nylon plug, wood screws etc. complete with all conduit accessories suitable MS pull boxes of suitable sizes as per site condition wherever required M.S. telephone point accessories boxes fabricated out of min 18 SWG/20 SWG thick CRCA sheet zinc passivated , brass earthing studs 1/2 nos., RJ-11 telephone socket outlets with shutter ferrule numbers on both side of the circuits all terminations with specifications & as per instructions of E-I-C. Note: 1. Point wiring means 4 pair CAT-6 wires from Telephone Tag Block to assigned point including end termination ofone pair at both sides and other pairs should be kept spare. 2. G.A drawings & fabrications drawing are to be got approved from E-I.C.
Point wiring for telephone point with 4 pair CAT-6 wire with RJ 11 jack type socket with shutter in a box with connector
Secondary Telephone extension Point (Jaco Point) looped to above item with 4 pair CAT-6 wire and with RJ 11 jack type socket with shutter in a box with connector
Telephone Tag Block (TTB) : Supply, installation, testing & commissioning of following readymade Krone connector telephone tag block box, 18SWG MS CRCA sheet, concealed/surface mounted on MS frame of size 40 x 40 x 5mm and grouted on the wall/fixed on the column free standing type with anchor fasterners,cable end/wire way box,if required, with adequate space facility to be provided in the TTB, with front operable hinged door, neoprene rubber/cork gasket for joints, wire bunching clamps , name plate etc. all as per standards,specification, drawing & instructions of E.I.C. Note: 1) Point distribution diagram shall put in side the DB with polythene protective cover. 2) All fabrication drawings shall be got approved. 3) Disconnection module shall be Krone Part No. 69011006-02 or equivalent approved.
50 pair telephone tag box : A set consisting of : 1) Disconnection module 2 /10 --> 5 nos. 2) Back mounting frame - 2/11 --> 1 nos ( C.T. box with mounting bracket ) 3) Transparent dust cover --> 1 no. complete with all accessories 4) Label Holder - 1 no
20 pair telephone tag box : A set consisting of : 1)Disconnection module 2 /10 --> 2 nos. 2)Back mounting frame - 2/11 --> 1 nos( C.T. box with mounting bracket ) 3) Transparent dust cover --> 1 no. complete with all accessories 4) Label Holder - 1 nos.
Telephone cables & end joints. Supply, installation, testing & commissioning of jelly filled telephone cable with copper conductor, PE insulated, cores twisted, G.I. wire/strip armoured, PVC sheathed cable fixed on wall/ column / slab on 5mm. thick GI spacer/MS flat support fixed with wood screws with 20 SWG GI saddle etc all fixing accessories and as directed by E-I-C..
0.5 mm dia 20 pair Telephone cable
End jointing of Telephone cable with all jointing materials like cable gland, ferrule lugs, ferrule numbers, wire dressing clamps/button tapes, etc. complete including all jointing materials and with necessary special tool kit for KRONE type connector and as directed by E-I-C.
0.5 mm dia 20 pair Telephone cable
TOTAL OF SECTION-VII: TELEPHONE SYSTEM
SECTION-VIII : LAN SYSTEM
LAN System : Supply, instalaltion, testing & commissioning of local area network system comprising of passive components like CAT-6 UTP or improved data cable, information oulet with RJ-45 connections , enclsoures for data outlets with faceplates concealed, patch panels, cable managers, LIU, OFC,splicing, 19" mounting racks , power panels in racks ,cooling fans in racks, flexible G.I pipe, PVC conduit HMS variety conforming to IS 9537 Part-III etc., complete with labeling/identification on the cable , outlets, patch panels etc. complete in all respect as required as per standards,drawings, specifications and instructions of E-I-C. Note : 1. LAN work shall be done by a specialised agency in the field. Credentials of the agency through which the bidder proposes to execute the LAN work to be submitted post W.O. 2. Evaluation of the proposed agency to execute the LAN work shall be carried out seperately by the Department. 3. Active components i.e switches etc are not in the scope of the agency and shall be executed by the users seperately. Agency shall extend full co-operation to the agency / users executing the balance work which is not in the scope of this tender. 4. Scope includes termination of cables at both ends with all accessories and installation/mounting of 19" racks with all accessories like angle iron frame work etc without any extra cost to the Department. 5. All LAN passive components shall be of same make.
Point Wiring :(LAN,Wifi and CCTV points) Point wiring in MS/PVC conduit HMS variety of size 25-40 mm dia ISI mark concealed in slab/column/beam/surface wherever required complete with bends, T/ Cross, junction box with all accessories with RJ-45 shuttered socket outlets (modular) concealed / surface in wall/column/ wherever required with all accessories including label holder, face plate, factory made zinc passivated box, screws etc terminated at one end at patch panel at respective floor at the other end in outlet with an extra loop length of approx 2 m at patch panel, ferrule numbers on both side, all terminations as per standards, drawing, specifications and as per instructions of E-I-C Note : 1. Patch panel shall be measured seperately. 2. Colour of the outlet and facia plate shall be matching with electrical switches and sockets with the approval of E-I-C.
Patch Panels: Supply, installation , testing & commissiong of 24 port, 19" rackmountable patch panel equiped with RJ-45 receptive female, CAT-6 UTP or better compatible to cat-6 cable and cable managers complete as required as per instructions of E-I-C.
LAN Racks:
Supply, installation, testing & commissioning of double section 19" wall mounted pivoting type, 15 U height & 600 mm depth rack having safety glass door & with standard accessories, including power supply panel, fans, cable manager, full cable entry plate with brush at top & bottom etc. complete as required & as per instructions of EIC.
Supply, installation, testing & commissioning of double section 19" wall mounted pivoting type, 9 U height & 600 mm depth rack having safety glassdoor & with standard accessories, including power supply panel, fans, cable manager, full cable entryplate with brush at top & bottom etc. complete as required & as per instructions of EIC.
CAT-6 Cable : Supply, installation, testing & commissioning of CAT-6 UTP cable in 25mm dia MS/PVC (HMS variety) conduit on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I. Saddles etc. for uplinking between patch panels, as required, including termination including end termination at both ends complete with all accessories all as required & as per instruction of EIC.
OFC Connection accessories in Network Rack : Supply, Erection, termination, testing and commissioning in inside the Wall mount / Floor Rack, following OFC connection accessories comprising of following items with suitable quantity required to complete fibre connectivity : a) 24 port fully loaded LIU - 2 nos. b) SC/LC Single mode OFC pigtails - 4 nos. c) SC to LC Single mode OFC patch chords (3m) - 2 nos. d) Any other accessories required to complete connection.
TOTAL OF SECTION-VIII : LAN SYSTEM WORKS
SECTION-IX : FIRE ALARM SYSTEM
Fire Alarm system (FAS) Design,supply,installation,testing & commissioning of analogue addressable type fire alarm system as per relevant Indian Standard specifications and conforming with relevant specifications of fire authorities of local Municipal Corporation, and as directed by E-I-C and consisting of the following: Note: 1) The work shall be carried out by licensed agency complying Maharashtra Fire prevention & Life safety measures Act 2006 with latest amendments. 2)Scope includes submission of factory test report of detectors,break glass and hooters and main panel and final inspection at site. 3)Make of all the components of FAS shall be same. 4) The Panel shall be suitable for networking using open technologies such as TCP/IP, Rs 485, modbus.
Multisensor Detectors : Supply ,installation,testing & commissioning of Intelligent addressable smoke detector unit working on multisensor detection technology with optical , heat detector sensor with inbuilt fault isolator complete with base as required & as per instructions of EIC.
Rate of Rise Heat Detectors (Thermal Detectors): Supply ,installation,testing & commissioning of Analog Addressable Heat Detectors with solid state design with sensing element combination of fixed type and rate of rise of temperature indicating LED, mounting base etc. as per detailed Specification.
Manual Call Point : Supply ,installation,testing & commissioning of dust and vermin proof Addressable Manual Call Point, break glass/pull station (square type/round type suitable for wall mounting surface/concealed) having painted/engraved/ embossed as “IN CASE OF FIRE, BREAK GLASS” on it, small hammer fixed with chain (in case of break glass), painting and other accessories as required. complete as required & as per instructions of EIC.
Loop powered Sounder with Strobe Light: Supply ,installation,testing & commissioning of Wall Mounting Alarm Intelligent loop powered sounder complete as per specifications and as required & as per instructions of EIC.
Response Indicator : Supply ,installation,testing & commissioning of Response indicator consisting of aluminium casting enclosure & steady glowing 2 nos.red indicator (LED) and cover plate shall be screen printed as "FIRE". The unit shall be suitable for connecting in parallel to the multisensor & wall mounting type with provision of 25mm dia conduit entries ,painting & other materials as complete as per specifications & of E-I-C.
Fire Alarm Panel Design,supply,installation,testing & commissioning of Analogue addressable microprocessor controlled Fire Alarm Control Panels, capable of being IP networked to the central monitoring System connecting through optical Fiber cable network to monitor and integrate above quantity of accessories like detectors, MCP's/loop power sounder/control modules, Fault Isolation Modules, Loop powered hooters, response indicators, fire/fault indicators, audio-visual signals, central processing units, complete with LED visual indicators, alpha-numeric display and audible alarm both for fire & fault, mains ON indication, test & reset provisions. Each loop should provided with integral SMF lead acid batteries with sealed cells (max 24 V) with appropriate AH capacity, as per IS requirement with integral battery charger, wire way box , if required , front openable lockable cover with front glass etc. complete as required and as per specification & instructions of EIC. Note: If charger & battery-capacities provided in redymade panel are not meeting operation requirement as per IS 2189 then charger & batteries shall be provided separately including wiring at no extra cost.
2 Loop panel
Supply ,installation,testing & commissioning of 12 relay transponder with surface mounting housing box and interconnection
Wiring for Fire Alarm System : Wiring with 2 nos. 1.5 sqmm FRLS-PVC insulated Shielded twisted pair copper cable/wires in 25mm dia concealed/surface MS/PVC conduit (HMS variety) including cost of cutting and filling chases for concealed conduit/ cost of saddles etc. for surface conduit as required and including the cost of crimped termination’s as required, complete as per instructions of E-I-C.
TOTAL OF SECTION-IX : FIRE ALARM SYSTEM WORKS
SECTION -X : LIGHTNING PROTECTION SYSTEM
Lightning Protection System :
Supply, installation, testing & commissioning of test link box consisting of 37 X 6 mm, heavily hot dipped GI test link, 25 X 8mm GI nut bolts & washers, suitable enclosure made of 2mm thick MS CRCA sheet with GI fixing screws/anchor fasteners etc., complete all as per STD drawing CSG/EM/STD -26 , specifications and as per the instructions of Engineer-in-charge.
Supply, installation, testing & commissioning of 25 x 6 mm heavily hot dipped GI earth strip for roofs conductors fixed on roof/wall/slab/ column with 5mm.thick GI spacers fixed with no. 10 GI wood screws & 2 mm thick GI saddles with GI machine screws, interconnection of earth strip with welded joints and GI nut bolts & washer painting with two coats of metallic paint, etc. instructions of Engineer-in-charge.
Supply, installation, testing & commissioning of 25 x 6 mm heavily hot dipped GI earth strip for down conductors fixed on roof/wall/slab/ column with 5mm.thick GI spacers fixed with no. 10 GI wood screws & 2 mm thick GI saddles with GI machine screws, interconnection of earth strip with welded joints and GI nut bolts & washer painting with two coats of metallic paint, etc. instructions of Engineer-in-charge.
Supply, installation, testing & commissioning 37 X 6mm heavily hot dipped GI earth strip for ground conductors fixed with no.10 GI wood screws & 1-2 mm thick GI saddles with G.I machine screws or in ground at 750mm below including excavation in all types of soil/rock with temporary reinstatement & back filling of trench, interconnection of earth strip with welded joints and GI nut bolts & washers, painting with two coats of metallic Aluminium paint for above ground portion & painting with two coats of black bituminous compound for earth strip in ground etc. all as per drawing, specifications and as per the instructions of the Engineer-in-charge.
TOTAL OF SECTION -X : LIGHTNING PROTECTION SYSTEM
SECTION-XI :EMERGENCY EVACUATION (PA)SYSTEM Emergency Evacuation/Public Address System (PAS) : Supply,installation,testing & commissioning of public Address system as per relevant standards, as directed by E-I-C and consisting of the following: Note. 1) The work shall be carried out by licensed agency complying Maharashtra Fire prevention & Life safety measures Act 2006 with latest amendments. 2)Scope includes submission of factory test report of controller,amplifire, speakers call station etc. 3)Scope includes interconnection of various PAS components in 19" cabinet/rack 4)Make of all the components of PAS shall be same. 5) The sysem shall be suitable for networking using open technologies.
Supply, installation, testing & commissioning of 8 zone digital System Controller complete in 19'' Rack mountable Dual tone, integration with existing Fire alarm system,control for Speech & Music, tone generator & Speech Processor with relays for activating tone & pre-recorded fire alarm messages etc as specified in the Tender Specifications. Note: scope also includes interconnection of existing FA panel with PA controller including testing & commissioning of interface of integrated FA-PA system
Digital Power Amplifier : Supply, installation, testing & commissioning of 19''rack mounted class-D Power Amplifier with on board DSP power for local signal processing, Switched mode power supply, Local audio inputs, Mains and battery operation and supervision, complete with following types and as per instructions of EIC. The amplifier shall be mounted in existing LAN rack.
2x250 W Power amplifier
Call Station : Basic Call Station with Power 'ON' indication, status/fault indications, priority level of destination is higher than that of the pending announcement indication, Supervision of microphone capsule and with built in On board DSP power for local audio processing. The call station basic can make manual or prerecorded announcements to any pre-assigned zones. The call station shall be provided with 18" gooseneck type microphone. The call station shall be fully supervised and must supports failsafe operation. Even if the network controller fails, the call station shall be able to put through emergency calls and as specified in the tender specifications and as per instructions of EIC.
PA system cabling: Supply, installation, testing & commissioning of 2 core twin twisted 48/0.2 ATC, multi stranded, overall PVC insulated and armoured cable (Blue colour) in existing PVC mini trunking, proper dressing of cables and including the cost of termination’s as required, complete as per instructions of E-I-C. The cost of mounting base boxes & the cost of providing cable glands etc shall be included in the scope of work.
Supply & installation of DVD player with USB support, in-built compressor & limiter as per instruction of EIC.
Supply, installation, testing & commissioning of 3 kVA double conversion (online) rack mountable UPS with single phase input and single phase output configuration with min. 15 minutes battery backup at 100% load using inbuilt sealed maintenance free batteries, flexible chord with plug in existing network rack as per instructions of EIC.
TOTAL OF SECTION-XI : EMERGENCY VOICE EVACUATION SYSTEM (PA) WORKS
SECTION-XII : T.V. SYSTEM
TV SYSTEM
T.V. point wiring complete with RG-6 solid co-axial copper conductor cable from spliter in 25mm dia MS/PVC (HMS) conduit in slab/wall or on the surface of slab/wall with G.I spacers & saddles fixed with nylon plugs, wood screws with all conduit accessories, suitable MS pull boxes/junction boxes, complete with modular T.V. socket outlet in readymade minimum 1 mm thick CRCA sheet zinc passivated brass earthing studs etc as required with connections at both ends all as per the instruction of E.I.C
Supply,installation,testing & commissioning of RG-11 solid co-axial copper conductor cable in 25mm dia PVC (HMS) concealed conduit in slab/wall or on the surface of slab/wall with G.I. spacers & saddles fixed with nylon plugs, wood screws with all conduit accessories, suitable M.S. pull boxes / junction boxes complete with connections at both ends (Between spliter to spliter / amplifier box) as per instruction of Engineer-in-charge.
Supply & installation of MS Box of 160 X 160 X 100 mm deep made of nominal 1.2mm thick CRCA sheet for T.V. antenna spliter box (concealed type ) with 4 way splitter with power pass & with knock-outs & front door with concealed hinges, locking arrangements complete with name plate, painting, and as per instruction of E-I-C.
TOTAL OF SECTION-XII : T.V SYSTEM WORKS
SECTION-XIII : MISCELLANEOUS ITEMS :
CABLE TRAYS AND CABLE MANAGEMENT SYSTEM Supplying and fixing following sizes of GI wire mesh tray, hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 carbon Steel cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required, and duly suspended from the ceiling with electro-zinc coated TF rods, wall mounting brackets etc.
150mm width x 50 mm depth
M. S. Boxes : Fabrication, supply and installation of M.S. boxes with 2 coats of primer & 2 coats of enamel / PU paint as per instructions of EIC.
MS Fabrication : Supply, fabrication and installation of supports using MS channel/angle / flat/ MS rod hangers etc.including cutting, fabrication, welding etc. and painting with two coats of primer and two coats of enamel/ PU paint of approved shade as per instructions of EIC.
In all soil other than soft and hard rock
In soft rock
In hard rock by chiselling or by using machine such as poclain with jack hammer etc.
Supply & installation of 250 mm dia heavy duty RCC Hume pipe of class 'NP3' to be laid in ground/from concrete cable trench to ground, for passing of cables with necessary joints, concrete supports. Scope includes excavation below ground level in all types of soil/concrete road cutting/foot path cutting, nallah cutting /any RCC wall/floor cutting including back filling, dewatering, consolidation, reinstatement of excess earth within the radius of 500 m and original,disposal making good to the original finish etc. spare space of hume pipes after cable laying and spares hume pipes shall be sealed properly with fireproof materials.
Supply, installation of GI pipe of B class sleeves in beams/ column/slab for passing electrical cables/conduit as per instruction of E-I-C.
80 mm dia
150 mm dia
Blank PVC (HMS) Conduits : Supply & installation of high mechanical stress (HMS) rigid PVC conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I. Saddles, MS/PVC pull out boxes, MS/PVC junction boxes, couplers, bends binding wires etc. as per site condition & as per instructions of E-I-C and of following sizes :-
25 mm dia
32 mm dia
40 mm dia
Flexible steel Conduit : Supply, installation, testing & commissioning of 25mm and 50mm liquid tight, FRLS , PVC coated Flexible Galvanised Steel conduit made up of helical coil of self interlocked ribbed stripes of Galvanised steel complete with necessary for rooftop solar PV system :
25mm conduit fixed to wall / slab / column / beam with 2mm thick GI saddle & 4-5 mm thick GI Spacer
50mm conduit fixed to wall / slab / column / beam with 2mm thick GI saddle & 4-5 mm thick GI Spacer
25mm on rooftop surface, laid along with earthing strip & clamped with earthing strip at every 200mm using 14 SWG GI wire.
50mm on rooftop surface , laid along with earthing strip & clamped with earthing strip at every 200mm using 14 SWG GI wire.
Supply, fixing & installation of pre mixed & ready to use M/s. HILTI make firestop foam CP 620 in 300ml bottle for sealing openings in electrical shafts, Telephone shaft, raceways & cutouts, hump pipes & where ever required & as per instruction of EIC.
Supply, fixing & installation of pre mixed & ready to use M/s. HILTI make firestop mortar CP 636 for sealing openings in electrical shafts, Telephone shaft, raceways & cutouts, hump pipes & where ever required & as per instruction of EIC.
Supply & laying of 50/42 mm OD/ID self lubricated HDPE pipes in ground at depth of 600 mm including cutting of existing footpath,road etc, sand bedding,laying of warning tape on top,temporary reinstatement.back filling ,dewatering if necessary consolidation,disposal of excess earth with in the radius of 500 m etc. or fixed on wall/column/slab with 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/ grouted in wall/anchor fasteners 2mm thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles all as per the attached work specification and instructions of EIC. Note: 1) The scope of work includes HDPE pipe accessories such as couplers, cable end plugs, cable sealing plugs etc.
In ground
On wall/ slab/ column/false ceiling/existing cable tray/existing hume pipe/trench/shaft/pit etc
PVC trunking system : Supply, installation, testing & commissioning of 80 x 50 mm PVC trunking with flexible cover of 65mm width of M/s Legrand make, suitable for mounting on wall as per instructions of EIC . Note: All the accessories like Internal, Flat & external angles, VDI accessories for internal, Flat & external angles, end caps, joint covers, cable tie base etc. suitable for 80 x 50 mm PVC trunking shall be included in the scope of work.
Insulating Mat : Supply and fixing in position of 'A' class ELASTOMER' insulating mat for protection to operators for working voltages upto 3.3 KV as per IS 15652 - 2006 of size 1000 mm (W) as per instructions of EIC.
Metering Box for Kitchen: Supply, installation, testing and commissioning of Non metallic Enclosures made of glassfibre-reinforced polyster and high transparent cover along with electrical installations mentioned below suitable for indoor use as per instructions of EIC:-i) 10-40A, 3 phase 4 wire static energy meter with RS 485 communication port - 1 nos.
Terminal boxes: Supply & erection of min. IP 65, Polycarbonate terminal box of 250 x 250 x 115 mm size, housing 4 Nos terminals (for 16 sqmm Al cable) on epoxy insulator, 3 nos 3A-6A SP MCB (as per load), 1no.neutral link, 1 no. earth link etc.
Providing and fixing danger plates made of mild steel 200x150mm atleast 2 mm thick & vitreous enameled white on both sides and with inscriptions "Medium Voltage" in single red colour on front side as required.
Supply & fixing of rigid self adhesive photoluminescent AUTOGLO sheet for indoor of different sizes & signage’s as per instruction of EIC.
TOTAL OF SECTION-XIII : MISCELLANEOUS ITEMS
SECTION-XIV: LED Luminaire ,Ceiling fan, Exhaust fans etc Supply, installation, testing & commissioning of LED luminaires complete with accessories etc on surface of slab/beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc., suitable supporting frame fixed with rag bolts grouted on the wall/anchor fastener on the beam/on the column & other fixing accessories etc provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. Notes: 1) Sample luminaire/fittings shall be got approved from Dept with complete technical data. 2) All luminairess shall be with drivers. 3) Cost of mounting accessories shall be included in luminaires cost. 4) The lumen output indicated is minimum system output of luminaire. 5) No negative tolerance is allowed on minimum system performance parameters indicated in the SOQ and specifications. 6) The CCT of the luminaire shall be decided at time of work execution.
Surface mounted LED luminaire 1500 lumen output similar to M/S Signify make cat no: SM200 LED 16S PSU 'Cirrus mini' or eq. approved
Surface mounted LED luminaire 2000 lumen output similar to M/S Signify make cat no: BN308C LED 20S PSU 'EnduraLED'or eq. approved
Surface mounted LED luminaire 2700 lumen output similar to M/S Signify make cat no: SM270 LED 30S PSU 'SmartBrite Surface' or eq. approved
Surface mounted LED luminaire 1000 lumen output similar to M/S Signify make cat no: SM250 LED 12S PSU 'Sleek Surface' or eq. approved
Surface mounted LED luminaire 2000 lumen output similar to M/S Signify make cat no: SM251 LED 20S PSU 'Sleek Surface' or eq. approved
Recessed mounted LED luminaire 3300 lumen output similar to M/S Signify make cat no: RC380B LED 36S PSU 'FullGlow' G5 or eq. approved
Ceiling mounted IP65 LED luminaires of 3400 lumen and similar to M/s Signify cat no BY300P LED 37S 'Wellglass' or eq approved
LED surface mounted bulkhead luminaire fitting having 600 lumen output similar to M/s Signify cat no. WT202 W LED 6S PSU 'EnduraLED bulkhead' or equivalent approved.
Surface mounted water proof LED luminaire 3800 lumen output similar to M/S Signify make cat no: WT201C LED 44S CW PSU 'Waterproof' or eq. approved
Surface mounted aluminum extruded linear, LED luminaire of 2400 lumen output with dimmable DALI driver similar to M/S Signify make cat no: SP780P LED26S PSD 'Pureline Slim' or eq. approved
Street light LED luminaries having a minimum efficacy of 110 lumen/watt and a minimum output of 3500 lumens, & pressure die cast Aluminium housing, UV stabilized polycarbonate / toughened glass diffuser having IP66 & IK07 protection etc. similar to M/s Signify cat no. BRP046 LED 36S PSU GR 'SmartBright Street' or eq. approved. as per specifications and instructions of EIC. The luminaire shall be mounted on 40 mm NB G.I pipe medium variety to IS 1239, 0.9m long bend to shape welded on GI plate fixed to wall with anchor fastner, GI saddle etc. as shown in drawing. Scope also includes internal wiring with 2.5 sq.mm copper conductor PVC wires from nearest existing terminal box to fixture in the PVC rigid/flexible pipe and earthing .
Supply & erection of 7 to 12W Bollard fixture, 800-1000 mm high, min.IP 65, IK 05, 2700-4000 degree K CCT, with PCC block of 200 x 200 x 200 mm for mounting on ground, anchor fastners, 2 nos 40/33 mm HDPE pipes in PCC block for passage of loop in & out cables etc. earthing etc. complete as required similar to M/S Signify make cat no: BCP150 LED /WW 6S PSU 'LED Bollard' or eq. approved as per instructions of E-I-C.
LED Dimming System : Supply, installation, testing & commissioning, including programming of following control modules complete with looping wiring from fixture to fixture with Cat-6 jumper cables & leader cable and interface module looping with Cat-6 wires all in PVC HMS conduit of 25-32 mm size etc. complete as required and as per instructions of E-I-C. The controller used shall be DIN rail mounting type in readymade metallic enclosure.
3 channel DALI broadcast controller similar to DDBC 300 of M/s Dynalite or equivalent approved.
DC regulated power supply similar to DDNP 1501 of M/s Dynalite or equivalent approved.
User interface device similar to Antumbra key pad + DACM-V2 of M/s Dynalite or equivalent approved
Emergency Luminaire : LED egress surface/recess, maintained type luminaire (double side viewing) in corridor near staircase with 1 hour backup similar to PEL LED E/M of M/s Prolite with all required hardware, egress symbols etc as per instructions of EIC.
Exhaust fans:
Supply, installation, testing & commissioning of 300mm dia size of exhaust/supply fans , single phase complete with blades, motor, scope includes supply of 3C copper 2.5 sq.mm. flexible chord of suitable length upto Ceiling rose near exhaust fan, aluminium louvers shutters, rag bolt/Anchor fasterner suitable MS angle iron frame made of 45 x 45 x 5 mm , 4 corners covered with 2 mm thick MS sheet to form suitable circular opening with necessary fixing arrangement, angled cowl with wire mesh as per specification, drawing as directed by E.I.C.
Supply, installation, testing & commissioning of 200/225 mm dia size of cassette type exhaust fans, single phase complete with blades, motor, scope includes supply of 3C copper 1.5 sq.mm. flexible chord of suitable length upto ceiling rose near exhaust fan with louvers with bird screen rag and fixing arrangement in window/wall as per instructions of EIC.
Ceiling Fans : Supply, installation, testing & comissioning of following Brushless DC (BLDC) ceiling fans with double ball bearing with following length downrod, canopies, shackles, blades with safety cable suspension (Secondary support safety cable) white colour with all accessories including continous earthing and final connection with 24/0.2 mm dia copper conductor 2/3 core twisted PVC flexible wire etc. Note: BLDC Fan should be as per technical specifications & testing conforming to IS 374/79 with latest amendments all as per specifications & instructions of E-I-C.
1200 mm sweep with GI down rod of varying lenghts from min 260 mm to 1000 mm as per location & instructions of E-I-C.
Fan Hook Boxes Supply, installation, testing of concealed fan hook boxes of size 150 x 150 x 75 mm deep fabricated out of 2mm thick M.S CRCA sheet with nominal 12 mm dia M.S tested rod hook with brass earthing stud & welded nut from inside and 2mm thick round M.S cover plate overlapping by 15 mm, including red oxide and two coats of white synthetic enamel paints and brass chromium plated screws and cup washers for fixing and all as per conceptional drawing No.: CED/EM /STD/11 R4 & instruction of Engineer-in-charge (Sample box with cover to be got approved before fabrication including the fabricator)
Water Heaters
Supply, installation, testing & commissioning of pressure type 25 litre capacity storage type (Horizontal mounting) water heater to work on 230 V AC supply with 2000 W heating element complete with all accessories, ISI mark, BEE min 4star rated with MS polymer/glass rust proof coating inner container and ABS plastic outer body, PUF insulation between inner & outer container, thermostat , thermal cut out, pressure release valve, 3 Cx 2.5 sq.mm PVC insulated stranded copper chord for interconnection between water heater to junction box, connector, flexible pipe of suitable size for inlet and outlet water connection etc . Scope includes M.S supports fabricated out of 25 mm 10 nettle fold screws in wall with nylon/phil plug & all mounting accessories including connection with suitable lugs, all as per specificaiton and instruction of E-I-C. Note: Sample water heater to be submitted for approval.
Supply, installation, testing & commissioning of instant type 1 litre capacity water heater to work on 230 V AC supply with 3000 W heating element complete with all accessories, ISI mark, with SS 304 inner container and ABS plastic outer body, PUF insulation between inner & outer container, thermostat , thermal cut out, pressure release valve, 3 Cx 2.5 sq.mm PVC insulated stranded copper chord for interconnection between water heater to junction box, connector, flexible pipe of suitable size for inlet and outlet water connection etc . Scope includes M.S supports fabricated out of 25 mm x 5 mm thick flat fixed on wall with 4 nos. of No. 10 nettle fold screws in wall with nylon/phil plug and all mounting accessories including connection with suitable lugs, all as per specificaiton and instruction of E-I-C. Note: Sample water heater to be submitted for approval.
TOTAL OF SECTION-XIV : LIGHTING LUMINAIRES
SECTION-II : XV : ROOFTOP SOLAR PV SYSTEM
Solar PV plant system package: Design, Supply, instalation, testing and commissioning of solar PV based plant comprising each of Mono- crystalline Solar Photo Voltaic Modules connected in series to form strings and various strings connected in parallel to form a array to generate DC power complete with solar inverter having built in MPPT's , all interconnecting solar copper DC cables with suitable connectors (module to module and upto array junction box and inverter), seperate array junction box having suitable 1000V, DC fuses, DC swich-disconnectors and required no. of surge protection devices, including providing 1.1KV grade XLPE insulated,PVC inner sheathed,G.I. strip armoured, FRLS PVC outer sheathed copper conductor cable between inverter and Solar PV MDB IN ELECTRICAL ROOM, termination with suitable glands and lugs etc. complete in all respects as per the detailed technical specifications and instruction of EIC & of the following capacities: Note: The bunch of DC cables from different strings shall be laid suitably in liquid tight flexible PVC coated galvanised steel conduit between grids of PV modules, from grid array juncton box and array junction box to inverter. The quantity of conduit is measure seperately under miscellaneous item No. 324
Min. 20 kWp Solar PV system with min.20 kWp input rated solar inverter
PV Module mounting structure items
Design, Fabrication,Supply, installation, testing and commissioning of completely modular GI mounting structure on rooftop for base structure for PV panel mounting, fabricated with hot dip galvanized MS channel and angels of different sizes for module mounting/fixing complete in all respects as per tender specification and as instructed by EIC
Supply, installation, testing and commissioning of Stainless steel (SS304) bolts & nuts of appropriate size with spring type washers for mounting the Solar module on GI mounting structure to bear the loading of PV modules
Supply, casting, installation of rectangular cement concrete blocks of suitable weight & suitable dimension with M20 grade PCC for dead weight support for Solar PV array structure as per tender specification & as instructed by EIC
TOTAL OF SECTION-XV : SOLAR PV WORKS
Description of Work / Item(s)
Amount
ABSTRACT OF PART-IV
Part IV : FIRE FIGHTING WORKS
PART - A - Firefighting works
PART - B - Electrical works
Description of Work / Item(s)
Amount
Part IV : FIRE FIGHTING WORKS
Terrace Fire Pump: Supply, installation, testing & commissioning of Motor driven Centrifugal Horizontal Pump Set for fire fighting system of following capacity & head along with all accessories with CI casing, Stainless Steel shaft, standard fittings, bronze impeller, suitable coupling to the electrical driven TEFC, squirrel cage induction motor suitably rated, with synchronous speed not exceeding 3000 rpm, Class-F insulation, IP-55, rated to operate at 415 V+/-10%, 50 Hz +/- 5%, 3 phase AC supply, including supply of of MS common base plate frame and installing pump set on it , foundation bolts, coupling guard, anti vibration pads and other accessories & connecting and jointing with suction & delivery piping with necessary reducers, enlargers, flanges etc, complete as per specifications, drawings and as instructed by Engineer-In-Charge. Providing weather proof hood fabricated weather as instructed by Engineer-In-Charge. NB: 1) The cost of all the items mentioned above are to be included under this item and no extra payment shall be made. 2) The sketch/ drg of weather proof cover is to be got approved by E-I-C before fabrication of the same.
i) 450 LPM at 35 m head
G.I. Pipes: Supply, installation, testing and commissioning of Heavy Duty, "C" Class GI pipes of following sizes confirming to IS-1239 along with all necessary fittings, flanges, jointing (screwed / welded / flanged etc.) and required supports with two coats of paint as per color code of the piping systems over two coats of red oxide primer, including all hardware, complete in all respects as per specifications and as instructed by Engineer-In-Charge. NB : 1) The pipe line shall be measured along the centre line. 2) Any Core cut if required for laying the pipes shall be included in above cost, no extra payment will be made for the same
100 mm dia.
50 mm dia
CI Gate Valves: Supply, installation, testing and commissioning of double flanged CI/Cast Steel Gate Valve of required sizes of ratings PN 1.6 with rising stem conforming to IS-14846 with all necessary fittings like flanges, neoprene gaskets, nut bolts, hardware, flanges, neoprene gaskets, nut bolts, hardware, flange joint etc. as shown in the drawings and as per specifications and as instructed by Engineer-In-Charge.
100 mm dia.
Gun Metal Gate Valve: Supply, installation, testing and commissioning of heavy pattern screw down Gun Metal Gate Valves of following sizes confirming to Class 2 of IS : 778 with hand wheels at top including testing for a pressure of 16 kg/sq.cm. for two hours, all as per specification, drawings and as instructed by Engineer-In-Charge.
50 mm dia.
Non Return Valve(Check Valve): Supply, installation, testing and commissioning of double flanged CI/ Cast Steel non return valves of following sizes of ratings PN 1.6 inline with relevant IS(flap/ball type) with gun metal working parts & CI body and including all necessary fittings flanges, neoprene gaskets, nuts bolts for fixing with pipe, hardware, joints etc. as per drawings, specifications and as instructed by Engineer-In-Charge.
100 mm dia.
HYDRANT LANDING VALVE Supply, installation, testing & commissioning of Single / Double outlet SS hydrant landing valve conforming to IS 5290 having 80 mm diameter flanged inlet 63 mm diameter instantaneous type female outlet with SS hand wheel, SS blank cap & GI chain conforming to IS 901, twist release type plug including nuts, bolts, washers, gaskets with necessary fittings like Tees, elbows etc. including providing 80 mm diameter GI pipe heavy class conforming to IS 1239 of suitable length to extend the hydrant from downcomer making flanged/welded joints, testing the unit, painting the hydrant valve and the exposed portion of GI pipe with 2 coats of signal red paint of approved make over a coat of approved make of primer, all as per specification and as instructed by Engineer-In-Charge.
Siamese Connections:
Supply, installation, testing & commissioning of Siamese connections having two numbers of 63 mm diameter G.M/SS inlet (instantaneous male coupling) along with one number 100 mm diameter C.I. double flange non return valve of rating PN 1.6 conforming to IS 5312 with G,.M working parts, and fittings all connected to 100 mm diameter GI pipe with necessary fittings including blank caps, flanges and joints, welding etc. and supplying and fixing of inlet housing box made out of 14 gauge M.S Sheet with angle and frame of suitable size and painting with two coats of synthetic enamel paint over a coat of approved primer over pipes and housing box and white enamel paint inside housing box complete in all respects as per specification and as instructed by Engineer-in-Charge.
Hose Reel With Drum: Providing & fixing rubber hose reel of 20 mm diameter x 37 m along with swinging drum along with high pressure braided rubber hose conforming to IS 884 including 8 mm diameter SS cut off nozzle on one end, wall mounting type, necessary brackets suitable for wall mounting, fixing on downcomer including connecting the other end to the downcomer by providing necessary connecting nipple/coupling, nuts, bolts etc. and providing & fixing 20 mm dia G.M. peet valve of approved make all complete including painting (the drum and brackets shall be painted with two coats of signal red enamel paint from outside and white enamel paint from inside) & as shown and as instructed by Engineer-In-Charge.
Hose Cabinet: Supply, installation & commissioning of 1.6 mm thick MS sheet metal hose cabinet of size 750x650x250 mmor appropriate for accomodating 02 nos. of hose pipes (measured & paid seperately under relevent SOQ item) and SS-304 branch pipe with nozzle. The box shall have front glass door lock with angle iron frame. The hose pipe box shall be fixed with Hilti make Anchor Fastner on the wall or nut bolts (in case of stand in open space) as shown in the drawing and as directed by EIC. The MS box shall be painted with two coats of signal red enamel paint from outside and white enamel paint from inside. The scope also includes supplying of gun metal / stainless steel branch pipe of 63 mm dia. fitted with detachable hexagonal nozzle of 19 mm dia. conforming to IS : 903 or universal pattern as per IS : 2871. The branch pipe with detachable nozzle shall be placed in the hose cabinet complete in all respect as instructed by Engineer-In-Charge.
Hose Pipe(For Hydrants, Landing Valve): Supply and installation of Unlined Flax Canvas (hose pipe) for fire fighting conforming to RRL fire hose type A or Synthetic Fibre Woven-Jacket (SFWJ) Elastomeric fire hose type B conforming to IS:636 all with ISI marks as required and of approved make and of 63 mm dia & 15 mtrs length, fitted with male and female SS coupling confirming to IS:903, ISI marks with guaranteed bursting pressure of 35.7 kg/sq.cm and complete as per the technical specifications and as instructed by Engineer-In-Charge. Each set shall comprise of 2 hose pipes.
Pressure Guages: Supply, installation testing and commisioning of pressure gauges of SS material with dial not less than 150 mm dia of appropriate range and complete in all respects with shut off gauge, cocks , all fittings etc, duly calibrated before installation in MKS and FPS units and duly tested after installation as per drawing and as instructed by Engineer-In-Charge.
Air Release Valve: Providing and fixing 20/25/40/50 mm dia (dia shall be as applicable as per relevant IS code) (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve conforming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) including making necessary flanged joints and providing all fitting materials nuts, bolts etc. and providing T on the pipeline for its installation at site all as per technical specification, drawings and as instructed by Engineer-In-Charge.
Orifice Plate: Design, supply and fixing stainless steel orifice plate of not less than 6 mm thick having suitable bore for reducing the pressure at the fire hydrant outlet as per fire brigade requirement and to restrict the operating pressure within 3.5 kg/sq.cm. at the fire hydrant outlet. The orifice plate shall be fixed in position & it shall be fitted between the flanges. The orifice plates shall have test certificate and calibrated to give the required pressure, complete all as per specification, drawings & as directed by E.I.C.
Valve Chamber: Construction of brick masonary valve chambers of following sizes comprising of 230 mm thick brick masonry in cement mortar 1:4 over a bed of 150 mm thick cement concrete of grade M-15 for foundation with 150 mm offset all round, including providing and fixing C.I. steps / foot rests / rungs each weighing not less than 5 Kg. first step at 450 mm from top of cover, remaining @ 300 mm centre to centre staggered with 380 mm spacing, painting etc. racking out joints & plastering in cement mortar 1:3, 20 mm thick both on internal and external surfaces, internal surfaces finished smooth with a floating coat of neat cement, providing 100 mm thick RCC slab casted in M.S. angle box frame (Galvanised) of 25 mm x 25 mm x 4 mm size in three equal pieces with reinforcement weighing not less than 100 kg/cu.m, fabricated M.S. angle all around & M.S. galvanised flat stiffners including formwork as per drawing etc. complete with lifting hooks at top, providing and fixing C.I. circular surface box weighing not less than 14 kg. over the RCC slab for key rod operation, painting all as per specifications and directions of EIC including dewatering the pit, if required till completion of the work.
1.2 m width x 1.2 m length x 1.2 m depth
M.S. Supports / Structure: Supply, cutting, fabrication, welding, erecting & fixing in position of M.S. support/structure (angle, channel, beam, plate, chequered plate etc.) for steps and other purpose (not applicable for items for which supports are already included in the item) including painting with two coats of synthetic enamel paint of approved make & shade over a coat of approved steel primer all as instructed by Engineer-In-Charge. Material shall conform to IS-2062.
PCC Pedestals: Providing PCC pedestals /thrust /anchor block of required sizes for underground pipes, fire hose box etc. and specials with cement concrete 1:2:4 at required intervals including form work, curing, finishing etc. complete in all respect as as per standard specifications and as instructed by Engineer-In-Charge.
Fire Extinguisher:
Proividing & fixing of Dry Chemical Powder (ABC) type fire extinguisher of 04 Kg capacity either portable or trolley mounted as per approved make fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS 15683-2006. The Fire extinguisher shall be supplied and placed without any damage, scratches and loss of accessories as per specifications and as instructed by Engineer-In-Charge.
Providing & fixing of, CO2 type fire extinguisher of 4.5 Kg capacity either portable or trolley mounted, highly effective against B & C class of fire, having ISI certification mark, having flat base including valve, discharge hose & complete in all respects including initial fill with CO2 gas conforming to IS 15683:2006, wall suspension bracket as required & as per instructions of Engineer In Charge. The Fire extinguisher shall be supplied and placed without any damage, scratches and loss of accessories as per specifications and as instructed by Engineer-In-Charge.
Foundation For Pump: Providing and laying Design-Mix Reinforced Cement Concrete foundation (design and drawing to be provided by contractor) for fire fighting pump of M-20 by weight batching using graded stone aggregate of 20 mm maximum size including mechanical mixing and vibration, consolidation, finishing, curing etc. as specified and also including dewatering, if any, cost of form work, shuttering & steel reinforcement, including nozing all around by 50 x 50 x 5 mm angle, all complete as per specifications, drawings and as directd by EIC.
Fire Bucket Supply and placing of fire sand bucket filled with dry and clean sand to be kept on floor or wall hook confirming to IS 2546. The fire bucket shall be galvanized mild steel of 9 litres capacity. The bucket shall be provided and placed as per instruction of EIC.
Bucket Stand Providing floor mounting stand for keeping 2 Nos. of FIRE buckets of 1000mm in length, 900mm in height, frame made out of 30x30x4 mm M.S. angle, rectangular bottom frame with cross supports for legs, suitable G.I. pipe shall be welded on the top end of of legs with 2 hooks on GI pipe for sand buckets and duly painted with one coat of red oxide and two coats of black paint all complete as per the given drawing, specifications or instruction of Engineer-In-Charge (E.I.C.)
TOTAL OF PART - A : Firefighting Works
PART - B : Electrical works
Remote ON / OFF P.B. Station: Supply, installation, testing and commissioning of 14 SWG MS CRCA sheet, remote ON/OFF push button enclosure, with ON / OFF indication lamps, IP 42, wall mounting type, powder coated with RAL 7032 shade complete with internal wiring with 1.5 sq.mm copper PVC FRLS wires etc. Note: 1) ON - OFF indication lamps shall be heavy duty LED type, 240V, 50 Hz 2) PB station shall be lockable type to prevent unauthorize operation of booster pump.
M.V.CABLES Supply, installation, testing & commissioning of 1.1 KV grade XLPE insulated, inner sheath PVC tapped, extruded FRLS PVC outer sheath, GI strip / wire armoured, multistranded Aluminium / copper conductor power cable confirming to IS : 1554 part I/IS 7098 part-1 with upto date amendments, fixed on wall/column/slab/false ceiling or in existing hume pipe/trench/ shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. Fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles and saddles all complete as per enclosed detailed specifications, drawings & as per instructions of the E-I-C & of the following sizes. The space between the two support shall be 600mm. approx.
4 C x 6 sq.mm copper conductor cable (On Wall / Trench / Cable tray)
3 C x 4 sq.mm copper conductor cable (On Wall / Trench / Cable tray)
End Joints: End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
4C X 6 sq.mm. copper conductor cable
3 C x 4 sq.mm copper conductor cable
Control Cable: Supply, installation, testing & commissioning of 1.1 KV grade multicore copper solid / stranded conductor of following sizes, PVC insulated, FRLS PVC outer sheathed armoured cable between various sensors and starter etc. on existing cable tray/surface on 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. Fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles and saddles etc. providing brass cable number tag as per enclosed detailed specifications, drawings & as per instructions of the E-I-C .The scope also includes end connections at both ends with glands etc. as required. 3 C x 2.5 sq.mm
Earthing System: 4 SWG GI strip/wire fixed to wall/side of trench/ slab/column/beam/shaft with 5mm thick G.I spacers & GI saddles or on existing cable tray etc.
TOTAL OF PART - B : Electrical works
ANS Constructions.com
Renjin Construction
ANS Constructions.com
Renjin Construction
ANS Constructions.com
Renjin Construction
ANS Constructions.com
Renjin Construction
ANS Constructions.com
Renjin Construction
Renjin Construction
ANS Constructions.com
Renjin Construction
ANS Constructions.com
KALPANA STRUCT CON PVT LTD
Renjin Construction
KALPANA STRUCT CON PVT LTD
Renjin Construction
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid