Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | ₹1.3 Cr | 1 | Accepted-AOC Acceptance of tender |
| 2 | 2₹1.4 Cr+₹14.2 L (10.9%)Rejected-Finance FIRST FLOOR 44 DDA SHOPPING COMPLEX BUDH BAZAR SIDE 42 KALKAJI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹1.4 Cr+₹14.2 L (10.9%) | 2 | Rejected-Finance Not L1 |
| 3 | 3₹1.5 Cr+₹15.4 L (11.8%)Rejected-Finance 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹1.5 Cr+₹15.4 L (11.8%) | 3 | Rejected-Finance Not L1 |
| 4 | 4₹1.9 Cr+₹63.6 L (48.7%)Rejected-Finance 452 1 STREET NO 2A KAULAGARH ROAD RAJENDRA NAGAR DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.9 Cr+₹63.6 L (48.7%) | 4 | Rejected-Finance Not L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
10 May 2025, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
PROVN OF 9 X LIGHTING CONDUCTOR FOR VARIOUS BLDGS OF AMC RECORD AND RELACEMNET OF CONVEBTIONAL LIGTS TO SOLAR STREET LIGHTS AT OFFS AND JCO / OR MD ACCN AND SPL REPLACEMENT OF EARTHING VTPN DBS AND REPLACEMENT OF BLDG SECURITY LIGHTS GATE LIGHTS AND
2024_MES_685640_3
CWE/LKO/E/T-98 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EAST LUCKNOW
₹2.8 L
Yes
6 Jun 2025
15 Apr 2025
12 May 2025
15 Apr 2025
10 May 2025
22 Apr 2025
15 Apr 2025 - 22 Apr 2025
Amount
Taking out Old Earthign Materials and making good disturbed surfaces all as specified and as directed by the Engr-in-Charge.
Taking out Old UNSV TPN DB/Meter Box/Switch boards any type and size as per retrieved from site and making good disturbed surfaces all as specified and as directed by the Engr-in-Charge.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wir 4 sqmm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
M/L for Sub Main wiring with under mentioned runs of S/C PVC insulated but unsheathed FRLS cable of specified size with multi stranded copper conductor 1100 volt grade IS-694 marked drawn through and including non metallic PVC conduit pipe medium grade ISI marked along with fittings and accessories all fixed on surface of wall in conduit and also including the specified runs of specified size earth continuity conductor of similar type of cable complete all as specified and directed (the under mentioned specified runs of single core cables and specified runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one length).
(a) 4 run of 10.0 Sqmm cable and 1 run of 10.0 sqmm cable connected to common earth dolly
(b) 4 run of 6.0 Sqmm cable and 1 run of 6.0 sqmm cable connected to common earth dolly
Supply and fixing all in one solar street/ Bidg security light fitting 17/18 watt complete. PV Module 75 Wp (Min) 12.8 V, Min 30 AH capacity lithium Ferro Phosphate battery, maint free. The luminaries must use high efficiency W-Led with min 135 lumens per watt (and UV free). The luminaries shall be tested for electrical,Photometry and colour parameters as per IES LM-79:2008 or IS : 16106:2012, over all total efficiency of the electronics should be min 90% with MPPT type charge controller with dusk to dawn operation complete protection of battery deep discharge reverse polarity (driver section) short circuit, No load/ Open load over load protection, SPV reverse polarity and no flow of current through battery to panel complete with aluminium extruded housing complete fix in wall mounted and necessary bracket nut & Bolts etc., complete all as specified and directed by Engineer-in-charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core all as specified and as directed by the Engr-in-Charge.
M &L for Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
M &L for Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of cables complete all as specified and directed.
Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
Supply & fix HDPE pipe DWC grade 80mm bore in trench/ wall/floor for protection of Cable including making good of the distubed surface all as specified and directed.
Taking down Old U/S lights of any type and size from existing site all as specified and directed.
Supply and fixing all in one solar street bldg security light fitting 30 watt complete PV Module 75 Wp (Min) 12.8 V, Min 30 AH capacity lithium Ferro phosphate battery, maint free The luminaries must use high efficiency W-Led with min 135 lumens per watt (and UV free). The luminaries shall be tested for electrical, Photometry and colour parameters as per IES LM-79:2008 or IS : 16106:2012, over all total efficiency of the electronics should be min 90% with MPPT type charge controller with dusk to dawn operation complete protection of battery deep discharge reverse polarity (driver section) short circuit, No load/ Open load over load protection, SPV reverse polarity and no flow of current through battery to panel complete with aluminium extruded housing complete fix in wall mounted complete all as specified and directed by Engineer-in-charge.
S & F street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm with nuts bolts & washers for fixing on wall complete necessary fixing arrangements on pole incl taking out old U/S bracket as directed.
Suplply,Installation, commissioning and testing Direct lighting protection sysytem CPRI tested early streamer lighting conductor Ait terminal with redious of protection of 60 mtrs and gain in triggering complete all as specified.
Suplply, ,Installation,commissioning and testing CPRI tested 7 segment 6 digit digital lightning event counter in all weather progg IP 67 grade poly propolyne enclosure with accessories complete all as specified.
Suplply, ,Installation,commissioning and testing Elevation mast for fixing air ter minal on top of the tower with (GI with FRP section) 1 Meter FRP and 3 meter GI with clamps and accessories for fixing and mounting complete all as specified.
Suplply, ,Installation,commissioning and testing down counductor ISI marked 50 Sqmm PVC insulated copper flexiable wire with accessories for fixing and mounting complete all as specified.
M &L CPRI tested transient earthing bonding unit in IP68 explosion proof enclosure for equipotential bonding among various services to avoid earth loop and differetial curruent flow to avoid equipment damges complete all as specified and directed.
S & F primary protection surge diverter, 340kA , 3 phase block MOV surge diverter in IP55 enclosure no. 01 Nos, 63 Amp, 3 phase , 4 wire, BMOVSD safty bracker - 01 Nos, copper flexiable cable 16 Sqmm min 25 mtrs complete all as specified and directed.
S & F Secondary protection 3 stage series power filter , 125 Amp 3 Phase series power filter - 01 No, 125 amp onload MSSPF service by pass block fitted -01 No, copper flexiable cable 50 Sqmm min 50 mtrs with lugs and accesserioes complete all as specified and directed.
S & F 480 kA , 3 Phase 4 wire equipment level protection using energy conversion apparatus, MIL STD energy conversion apparatus digital grounding -01 No, complete all as specified and directed.
S & F Protection for RF Communication lines and discrate access switches, RJ 45 protection module single port -02 nos and complete all as specified and directed.
M&L for Maint free earthing CPRI tested 8fit 2.5 inch dia 11.6 mm thickness with pure electrolyte copper tube earthing system charged with PCG ion and active catelyzer complete with heavy duty plastic inspection chamber min earth test result below 01 ohm Note:- (i) The earth pit shell be refiilled by boulders free from vegetable soil. (ii) Earthing shall be tested by contractor in presence of engr-in-charge. Record shell be maint payment shall be admissiable only after satisfactorly test result. (iii) Necessary borewell shell be carried out by the contractor
Supply and fix copper flexiable cable 70 Sqmm of size with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed
Supply and fix copper strip of size 20 x 3.00 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed
Supply and fix epoxy insulator with red colour incl with nut and bolt suitable for fixing size of strip 20 X 3.00 mm complete all as specified and directed
Supply and fixing all in one solar street/ bldg security light fitting 40 watt complete PV Module 75 Wp (Min) 12.8 V, Min 30 AH capacity lithium Ferro phosphate battery, maint free.The luminaries must use high efficiency W-Led with min 135 lumens per watt (and UV free). The luminaries shall be tested for electrical, Photometry and colour parameters as per IES LM-79:2008 or IS: 16106:2012, over all total efficiency of the electronics should be min 90% with MPPT type charge controller with dusk to dawn operation complete protection of battery deep discharge reverse polarity (driver section) short circuit, No load/ Open load over load protection, SPV reverse polarity and no flow of current through battery to panel complete with aluminium extruded housing complete fix in wall mounted and necessary bracket nut & Bolts etc., complete all as specified and directed by Engineer-in-charge.
Supply and fixing E18 of Lithium based Energy efficient Integrated Solar garden / Bollard Light of max 5 Watt 800 luman lights, new genration, energy saving envioremental friendly long life aesthelically designed weather proof lumaniare IP65 and IK 07 protection die cast aluminium land scape luminaire for down ward lighting with high power LED as , surge protection 100 V -240 V all as per civil work ilke coping of pole height of PCC from ground lavel min one feet, and earth work for fixing of pole is included in the item rate and No extra payment will be done to the contractor complete all as specified and directed by Engineer- in- charge.
Supply and fix LED Solar based gate light with lithium battery 3.7V/2000mAh with solar panel 1.1 W, ABS housing with efficacy 140Lm/W and output 300 lumens of with remote Incl GI Pipe 40mm dia 0.45mtr long fixed in gate pole with PCC 1:2:4 of 0.20 mtr height and size of existing gate pole. Fixture lumen efficacy >4500 Lm, IP66 (no glue), IK05, PF>0.95, Operating voltage range: 140- 277V, Incl cutting/ drilling of exiting gate pillar 0.6 mtr long GI Pipe 40 mm dia medium grade or suitable size of gate light fixed in gate /pillar with PCC 1:2:4 of 0.30 mtr height and size of existing gate pole complete all as specified and directed by Engineer- in- charge.
Unex Power Point Pvt Ltd (BID ID -3288160)
T.I.John and Sons (BID ID -3289287)
M/S SEWA AND SERVE BUILDERS (BID ID -3288053)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .