Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
2 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT.GEN.
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(available in GCC), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Calculation of required minimum average annual contractual turnover- V = Rs. 14217741, N= 9 months = 0.75 year, V/N= 14217741/0.75 = Rs. 18956988, V is less than V/N, Hence, required minimum average annual contractual turnover = Rs. 14217741
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: (1) Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate
Defination of Similar Work :- Electrification / Rewiring of Service or Residential building / Yard / HT / LT substation work / HT / LT cable work / street lighting / platform or building lighting management / circulating area Lighting / Electrical overhead power supply work / Electrical pump work etc.
13 conditions · 7 needing a document upload
The registration of contractors working under Railway departments with ESIC is mandatory (if applicable as per current Law / Act)
In case a tenderer is participating as Sole Proprietor in a tender, it is mandatory for him to submit an undertaking on suitable stamp paper to this effect clearly mentioning PAN number also along with tender document at the time of submission of tender.
The tenderer may submit scanned copy of partnership deed if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor shall ensure all precautions during digging work close to Rly signaling, telecom electrical cables etc. Penalties to be imposed for damages to any cable as per Railway board letter no. 2021/Tele/5(2)/3- Part(1)/(3425647) dtd 12.06.2023
Electrification work in connection with provision of pathway in Bhusawal, Badnera, Nandgaon, and Khandwa yard.
BSL-L-W-T-49-2026
BSL-L-W-T-49-2026
Open
Works - General
9 Months
Jalgaon, Maharashtra
₹0
₹2.8 L
2 Jul 2026
9 Jun 2026
18 Jun 2026
88 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,42,17,741 | ||
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of 20 Mtrs. GI Stadium Mast as per Dimension: Top Dia.-150 mm, Bottom Dia. - 480 mm, Section- 2 (Section Length - 10300 mm.) Thick- T1- 4 /T2-5 mm.Base Plate - 670 X 32 mm.PCD: 590; stadium Mast suitable to with stand wind speed 50 m/s with 11 nos LED FLOOD LIGHT Mounted in Asymetrical arrangement, With Foundation Bolts : M30 X 850 X 12Sets., 32 Amp Feeder Pillar, Platform and Ring for housing LED Luminaires, Counterweightarrangement with fixing studs, Motorized accessories with winch,trailing cable,wire rope, SD LED AOL. (BD=2, KNW=2, NGN=2, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 31,95,906 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of 16 meters high mast system with accessories mast shall be in two sections, hot deep galvanized and suitable for wind velocity as per IS 875, erection complete with guarding ploes. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=5, SSE/EM/South/BSL=0) | — | — | — | 12,66,780 | |
| — | Item Breakup for | details. | — | ||
| SETC of 20 Mtr. High Mast lighting tower with foundation along with 9x350 watt LED fittings complete with all accessories. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=4) | — | — | — | 20,23,704 | |
| — | Item Breakup for | details. | — | ||
| Fabrication, supply and erection of Fencing around the high mast in square shape size 2M x 2M and height 1.5M from ground level fabricated from MS angle size40x40x6mm, MS Flat size 40x6mm and wire mesh made of 8SWG wire and 1M wide hinged type lockable door as per drawing approved by Railway including grouting, CC platform around the high mast above 0.30M above ground level and painting etc. complete as per site requirement. (BD=2, KNW=2, NGN=2, SSE/EM/NRSS/BSL=5, SSE/EM/South/BSL=4) | — | — | — | 1,31,055 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of maintenance free earth as per RDSO specification no. RDSO/PE/SPEC/ PS/0109-008 (REV '0') with improved earthing enhancing compound and exothermic welding (BD=4, KNW=10, NGN=20, SSE/EM/NRSS/BSL=20, SSE/EM/South/BSL=15) | — | — | — | 10,50,111 | |
| — | Item Breakup for | details. | — | ||
| Supply, fabrication, laying welding and connection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size. (BD=200, KNW=100, NGN=100, SSE/EM/NRSS/BSL=200, SSE/EM/South/BSL=200) | — | — | — | 91,200 | |
| — | Item Breakup for | details. | — | ||
| Supply of 4 core 16 sqmm armoured XLPE Cable. (BD=0, KNW=500, NGN=500, SSE/EM/NRSS/BSL=100, SSE/EM/South/BSL=0) | — | — | — | 2,05,700 | |
| — | Item Breakup for | details. | — | ||
| Supply of 4 core 25 sqmm armoured XLPE Cable. (BD=1000, KNW=300, NGN=100, SSE/EM/NRSS/BSL=1000, SSE/EM/South/BSL=500) | — | — | — | 7,07,600 | |
| — | Item Breakup for | details. | — | ||
| Supply of LT XLPE Armoured 4 Core 50 Sqmm Aluminium cable as per relevant IS. (BD=0, KNW=0, NGN=100, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=500) | — | — | — | 2,70,600 | |
| — | Item Breakup for | details. | — | ||
| Supply of 4 Core 70 Sqmm armoured LT XLPE Cable. (BD=0, KNW=100, NGN=100, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=500) | — | — | — | 3,63,300 | |
| — | Item Breakup for | details. | — | ||
| Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm) (BD=600, KNW=400, NGN=400, SSE/EM/NRSS/BSL=700, SSE/EM/South/BSL=800) | — | — | — | 6,69,900 | |
| — | Item Breakup for | details. | — | ||
| Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site. (BD=200, KNW=300, NGN=300, SSE/EM/NRSS/BSL=200, SSE/EM/South/BSL=200) | — | — | — | 4,81,200 | |
| — | Item Breakup for | details. | — | ||
| Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure. (BD=800, KNW=700, NGN=700, SSE/EM/NRSS/BSL=900, SSE/EM/South/BSL=1000) | — | — | — | 1,27,100 | |
| — | Item Breakup for | details. | — | ||
| Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware (BD=200, KNW=200, NGN=100, SSE/EM/NRSS/BSL=200, SSE/EM/South/BSL=500) | — | — | — | 86,400 | |
| — | Item Breakup for | details. | — | ||
| Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable. (BD=50, KNW=70, NGN=15, SSE/EM/NRSS/BSL=90, SSE/EM/South/BSL=30) | — | — | — | 51,510 | |
| — | Item Breakup for | details. | — | ||
| Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS-4984-1995. (BD=50, KNW=80, NGN=50, SSE/EM/NRSS/BSL=50, SSE/EM/South/BSL=50) | — | — | — | 1,40,000 | |
| — | Item Breakup for | details. | — | ||
| Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. (BD=700, KNW=600, NGN=300, SSE/EM/NRSS/BSL=200, SSE/EM/South/BSL=900) | — | — | — | 2,91,600 | |
| — | Item Breakup for | details. | — | ||
| Supply and laying of RCC Hume Pipe of size 6"(150mm) dia 2 mtr. Length. (BD=2, KNW=5, NGN=5, SSE/EM/NRSS/BSL=5, SSE/EM/South/BSL=25) | — | — | — | 31,710 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection of RCC Type cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. (BD=10, KNW=10, NGN=20, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 17,960 | |
| — | Item Breakup for | details. | — | ||
| Supply & Erection of RCC Warning Cover and refilling the cable trench in an approved manner. (BD=10, KNW=10, NGN=20, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 18,920 | |
| — | Item Breakup for | details. | — | ||
| Supply & erection of FRP junction box of suitable size having terminals and 1x16 A Cut out with Two Nos of entry glands. (BD=0, KNW=2, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=20) | — | — | — | 18,788 | |
| — | Item Breakup for | details. | — | ||
| Supply & erection of 3 core x 2.5 Sqmm armoured copper Cable. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=100) | — | — | — | 16,400 | |
| — | Item Breakup for | details. | — | ||
| Supply, fabrication, fixing and erection of MS Work of miscellaneous size and for cable tray etc. including painting complete. (BD=100, KNW=100, NGN=100, SSE/EM/NRSS/BSL=20, SSE/EM/South/BSL=100) | — | — | — | 44,940 | |
| — | Item Breakup for | details. | — | ||
| — | — | — | 1,22,560 | ||
| — | tio n :- Supply of in ratio | all material,excavation 1:3:6 for above work. | cement SSE/EM/NRSS/BSL=5, | ||
| — | Item Breakup for | details. | — | ||
| SETC of LT Outdoor type panel as per IEC 61439 with double door powder coated withlocking arrangements consisting of 1 Nos x 200 A 4P MCCB, 4 Nos x 63 A 4P MCCB With ELR & CBCT for each MCCB, multifunctionmeter, indication lamp, copper busbar, & other assocciate aceesories. All MCCB are Microprocessor based (completely wired with suitable communication cable to fetch data from each compartment functional Unit (ACB/MCCB/SFU etc) / Multifunction Meter) (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=1) | — | — | — | 5,03,421 | |
| — | Item Breakup for | details. | — | ||
| SETC of LT Outdoor type panel as per IEC 61439 with double door powder coated withlocking arrangements consisting of 1 Nos x 125 A 4P MCCB as I/C and 4 Nos x 63 A 4P MCCB With ELR & CBCT for each MCCB, multifunctionmeter, indication lamp, copper busbar, & other assocciate aceesories. All MCCB are Microprocessor based (completely wired with suitable communication cable to fetch data from each compartment functional Unit (ACB/MCCB/SFU etc) / Multifunction Meter) (BD=0, KNW=1, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 4,38,910 | |
| — | Item Breakup for | details. | — | ||
| Providing & erecting Hot dipped Galvanised Perforated type cable tray manufactured from 16 SWG (1.6 mm thick) Gl sheet of 300 mm width & 100 mm height comprising all required standard accesssories. (BD=0, KNW=0, NGN=50, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 53,300 | |
| — | Item Breakup for | details. | — | ||
| shifting of Pole of suitable size and re-erection of the pole with foundation & complete accessories etc. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=20, SSE/EM/South/BSL=0) | — | — | — | 40,000 | |
| — | Item Breakup for | details. | — | ||
| Dismantling of existing Light poles with infrastructure and handing over to depot incharge at their depot. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=20, SSE/EM/South/BSL=0) | — | — | — | 27,020 | |
| — | Item Breakup for | details. | — | ||
| Supplying, fixing and commissioning 4 pole RCBO up to 16A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indications per specification (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=10, SSE/EM/South/BSL=0) | — | — | — | 47,760 | |
| — | Item Breakup for | details. | — | ||
| Supplying, fixing and commissioning 4 pole RCBO 32/40A with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification (BD=0, KNW=0, NGN=1, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=25) | — | — | — | 1,28,752 | |
| — | Item Breakup for | details. | — | ||
| Supplying, fixing and commissioning 2 pole RCBO up to 16 A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification with metal enclosure. (BD=0, KNW=0, NGN=1, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=10) | — | — | — | 41,107 | |
| — | Item Breakup for | details. | — | ||
| Supply, installation, testing & commissioning of single phase RCBO of 32A capacity, 30mA sensitivity with Metal enclosure. (BD=0, KNW=0, NGN=1, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 3,480 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Double walled corrugated (DWC) pipes 103.5 MM inner dia & 120 MM outer dia confirming to IS specification No. IS.14930- (Part 2) 2001 with one coupler for every 6 meter length of pipe. (BD=0, KNW=0, NGN=200, SSE/EM/NRSS/BSL=500, SSE/EM/South/BSL=0) | — | — | — | 98,000 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of 7 Mtr high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation. (Along with 2 pole RCBO 6A, with 30 mA sensitivity & single/Double arm with wiring arrangments). (BD=0, KNW=0, NGN=10, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=10) | — | — | — | 3,05,480 | |
| — | Item Breakup for | details. | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 48W maximum, whether proofhaving IP 65/66 protection, having inbuilt auto dimming driver and sensor, System efficacy 100lm/W, Luminaires must be capable of delivering minimum 4800 lumens, luminaries complete with allaccessories. (BD=6, KNW=0, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 50,064 | |
| — | Item Breakup for | details. | — | ||
| SETC of 160 Watts LED Flood light fittings with high luminous efficiency, protected to IP65. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=10) | — | — | — | 1,32,220 | |
| — | Item Breakup for | details. | — | ||
| SETC of LED street Light Roadway fittings in aluminium PDC housing, toughened glass cover withIP66 protection, Wattage 70 ±2 watts, input voltage-240 volts ac, 50Hz. Complete with PIR sensor based with IR sensor. (BD=0, KNW=0, NGN=10, SSE/EM/NRSS/BSL=10, SSE/EM/South/BSL=20) | — | — | — | 3,19,040 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of 300 W LED High Mast Flood Light for Tower as per specification. (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=45, SSE/EM/South/BSL=0) | — | — | — | 4,46,040 | |
| — | Item Breakup for | details. | — | ||
| SITC of 22-30W LED pit light 24V AC 50 Hz. with IP67/IP68 protection integral luminaries, compact, robe, ORHS compliance, available in white color, Make- Jaquar, Halonix, Surya, Ultraone. (BD=0, KNW=2, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 7,802 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing and commissioning of Astronomical street light control panel outdoortype CRCA sheet steel powder coated capacity- 6 kW single phase consisting digital 24 Hr timer, 32 A TP contactor, 40 A SPN (DP) MCB, auto/manual switch with complete wiring suitable to bemounted on channel/angle fixed on electrical pole IP-32 (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=1, SSE/EM/South/BSL=0) | — | — | — | 11,793 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of Lighting circuit board double door powder coated with locking arrangement consisting of 1 Nos x 63 A 4P RCBO as incoming and 8 Nos x upto 25 A 2 P RCBO, 10 Nos x upto 16 A 2 P RCBO for outgoing complete. (BD=0, KNW=0, NGN=1, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=0) | — | — | — | 1,19,783 | |
| — | Item Breakup for | details. | — | ||
| Supply, erection, testing & commissioning of LT Mini feeder pillar (BD=0, KNW=0, NGN=0, SSE/EM/NRSS/BSL=0, SSE/EM/South/BSL=1) | — | — | — | 18,825 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022dt.27.04.2022.pdf GCC Apr 2022
ATTACHMENT
ACS1to6ofGCC.pdf
ATTACHMENT
ACS7to10ofGCC.pdf
ATTACHMENT
ACS11toGCC.pdf
ATTACHMENT
Tenderdocument492026.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .