| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | ₹20.3 L Quoted ₹21.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹26.6 LRejected-AOC 296 SECTOR 15 PANCHKULA HARYANA | ₹26.6 L | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | PARTAP ENGINEERING WORKS L1 | KAPOOR ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | Servicing & repair / replacement of defective / unserviceable parts of RO Plant having capacity 60 litres per Hr including testing of the RO plant for entire satisfaction of Engr-in-Charge.
Note: (a) The Contractor shall be responsible for continuous serviceability of each RO during the tender period.
(b) Servicing of RO Plant shall be carried out by the contractor minimum two times after gap of five months in same quoted rate.
(c) Unserviceable parts shall be measured and paid separately under the respective items as supply only. | 10 | Each RO | 5,000 ₹50,000 | 2,000 ₹20,000 |
| 1.01 | Supply only Spun filter length 20”.Make - Ion Exchange, Livpure, Aquafresh, Kent | 20 | Each | 1,100 ₹22,000 | 150 ₹3,000 |
| 1.02 | Supply only Carbon filters length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent | 20 | Each | 510 ₹10,200 | 400 ₹8,000 |
| 1.03 | Supply only Membrane complete assembly 40/80 flow rate length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent | 20 | Each | 1,500 ₹30,000 | 4,000 ₹80,000 |
| 1.04 | Supply only Superior quality RO pipe of PVC pressure rating 6kg/cm2 of size 3/4'' dia including all connected fittings. | 80 | RM | 100 ₹8,000 | 80 ₹6,400 |
| 1.05 | Supply only Booster pump motor 0.5 HP , single phase, 230 phase. | 6 | Each | 3,800 ₹22,800 | 6,000 ₹36,000 |
| 1.06 | Supply only RO solenoid valve for 60 Ltrs RO Plant. | 5 | Each | 700 ₹3,500 | 400 ₹2,000 |
| 1.07 | Supply only Primary filter housing complete body with candle , elbow & top cover length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent | 5 | Each | 1,000 ₹5,000 | 600 ₹3,000 |
| 1.08 | Supply only Carbon filter complete body with candle , elbow & top cover length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent | 5 | Each | 700 ₹3,500 | 800 ₹4,000 |
| 1.09 | Supply only Membrane Housing with membrane suitable for 60 LPH RO. Make - Ion Exchange, Aquafresh, Livpure, Kent | 4 | Each | 1,500 ₹6,000 | 1,500 ₹6,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
3 Oct 2025, 6:00 pmClosed
Garrison Engineer
GE (U) Chandimandir Pin-134107
CA NO GE(U)/CHM-40/2025-26 REPAIRS AND MAINTENANCE OF VARIOUS CAPACITY OF RO PLANTS, OIL HEATER, UPS SYSTEM AND SURGICAL LIGHTS (OT LIGHTS) INSTALLED AT COMMAND HOSPITAL (WC) UNDER GE (U) CHANDIMANDIR
2025_MES_726380_1
GE(U)/CHM-40/2025-26
Open Tender
Miscellaneous Works
300 days
GE (U) Chandimandir
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹70,000
Yes
29 Jan 2026
29 Aug 2025
4 Oct 2025
29 Aug 2025
3 Oct 2025
13 Sept 2025
Amount
Supply only Spun filter length 20”.Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Carbon filters length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Membrane complete assembly 40/80 flow rate length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Superior quality RO pipe of PVC pressure rating 6kg/cm2 of size 3/4'' dia including all connected fittings.
Supply only Booster pump motor 0.5 HP , single phase, 230 phase.
Supply only RO solenoid valve for 60 Ltrs RO Plant.
Supply only Primary filter housing complete body with candle , elbow & top cover length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Carbon filter complete body with candle , elbow & top cover length 20”. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Membrane Housing with membrane suitable for 60 LPH RO. Make - Ion Exchange, Aquafresh, Livpure, Kent
Supply only Stainless steel fabricated of grade SS 304 RO stand for 60 Ltrs plant.
Supply only flow resistance (FR) suitable for 60 LPH RO.
Supply only TDS adjustor suitable for 60 LPH RO.
Supply only flow valve suitable for 60 LPH RO plant.
SMPS DC output power supply 5 Amp, 24/36 Volts
Supply only high pressure switch suitable for 60 LPH RO.
Supply only low pressure switch suitable for 60 LPH RO.
Supply only Apec aqua plastic RO direct inlet quick valve straight connector 1/2" for female thread and 1/4" push fit for RO water purifiers suitable for 60 LPH RO.
Supply only water cooler 15/20 mm tap connector with female brass insert 15x30x50 suitable for 60 LPH RO.
Supply only Spun filter length 10” Make: Ion Exchange, Livpure, Aquafresh, Kent
Supply only Carbon filters length 10” Make: Ion Exchange, Livpure, Aquafresh, Kent
Supply only Membrane complete assembly 100 GDP. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Booster pump 300 GDP, single phase, 230 phase.
Supply only RO solenoid valve for 25 Ltrs plant. 24 VDC.
Supply only Primary filter complete body with candle, elbow & top cover length 10”. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Stainless steel fabricated of grade SS 304 RO stand for 25 Ltrs plant.
Supply only Carbon filter housing complete body with candle, elbow & top cover 10". Make - Ion Exchange, Aquafresh, Livpure, Kent
Supply only membrane Housing with membrane. Make - Ion Exchange, Livpure, Aquafresh, Kent
SMPS DC output power supply 2.5 Amp, 24/36 Volts.
Supply only Superior quality RO pipe of PVC pressure rating 6kg/cm2 of size 1/4'' dia including all connected fittings.
Supply only flow resistance (FR) suitable for 25 LPH RO.
Supply only TDS Adjustor suitable for 25 LPH RO.
Supply only flow valve suitable for 25 LPH RO.
Supply only high pressure switch suitable for 25 LPH RO.
Supply only low pressure switch suitable for 25 LPH RO.
Supply only Apec aqua plastic RO direct inlet quick valve straight connector 1/2" for female thread and 1/4" push fit for RO water purifiers suitable for 25 LPH RO.
Supply only water cooler 15/20 mm tap connector with female brass inser 15x30x50 suitable for 25 LPH RO.
Supply only spun filter suitable for 100 Ltrs RO Make: Ion Exchange, Aquafresh, Livpure, Kent
Supply only carbon filter suitable for 100 Ltrs RO Make: Ion Exchange, Aquafresh, Livpure, Kent
Supply only Membrane complete assembly suitable for 100 Ltrs RO Make: Ion Exchange, Aquafresh, Livpure, Kent
Supply only Booster pump suitable for 100 Ltrs RO single phase, 230 phase.
Supply only RO solenoid valve for suitable for 100 Ltrs RO plant, 24 VDC.
Supply only Primary filter complete body with candle, elbow & top cover suitable for 100 Ltrs RO complete all as specified and directed. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only Membrane Housing with membrane suitable for 100 LPH RO. Make - Ion Exchange, Aquafresh, Livpure, Kent
Supply only SMPS DC output power supply suitable for 100 LPH RO, 24/36 Volts.
Supply only Superior quality RO connection pipe of size 1/4" dia including all connected fittings
Supply only flow resistance (FR) suitable for 100 LPH RO
Supply only TDS Adjustor suitable for 100 LPH RO
Supply only flow valve suitable for 100 LPH RO
Supply only only high pressure switch suitable for 100 LPH RO
Supply only low pressure switch suitable for 25 LPH RO.
Supply only Apec aqua plastic RO direct inlet quick straight connector 1/2" for female thread and 1/4" push fir for RO water purifiers suitable for 100 LPH RO
Supply only water cooler 15/20 mm tap connector with female brass inser 15x30x50 suitable for 25 LPH RO.
Servicing & repair/replacement of defective/ unserviceable parts of Trolly mounted RO Plant having capacity 220 litres per Hr, including testing of the RO plant to the entire satisfaction of Engr-in-Charge. Note: (a) The Contractor shall be responsible for continuous serviceability of each RO during the tender period. (b) Servicing of RO Plant shall be carried out by the contractor minimum two times after gap of five months. (c) Unserviceable parts will be measured and paid separately under the respective items.
Supply only sand Media as per approved sample.
Supply only carbon Media as per approved sample.
Supply only Chemical (Resin and sodium chloride) as per approved sample.
Supply only cartridge filter as per approved sample. Make - Ion Exchange, Livpure, Aquafresh, Kent
Supply only TDS adjustor for 220 LPH RO plant as per sample.
Supply only motor pump 0.5 HP as per sample
Supply only high pressure pump of size 2 HP suitable for 220 LPH RO plant as per sample
Supply only multi pot valve as per sample
Supply only pressure pump seal as per sample
Supply only display for 220 LPH RO plant as per sample
S&F PVC insulated flexible copper conductor cable 1 Sqmm 3 core, 1100 Volts grade conforming to IS 694 (FRLS) complete all as specified and as directed
S&F PVC insulated flexible copper conductor cable 1.5 Sqmm 3 core, 1100 Volts grade conforming to IS 694 (FRLS), complete all as specified and as directed
S&F Plug top 5 Amp, 3 pin including making electrical connections with existing cable and taking down existing plug top, complete all as specified and directed
Supplying and laying as in replacement of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed.
Supplying and laying as in replacement of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed.
Supplying and laying as in replacement of 32 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed.
Supply & fixing in replacement of CPVC gate valve of size 20 mm dia suitable for existing RO pipe line complete all as specified and directed
Supply & fixing in replacement of CPVC gate valve of size 25 mm dia suitable for existing RO pipe line complete all as specified and directed
Supply & fixing in replacement of CPVC gate valve of size 32 mm dia suitable for existing RO pipe line complete all as specified and directed
Material and labour in replacement for Sub main wiring with 2 run of 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 1.5 Sqmm (nominal area) FR, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified & directed
Supply and fixing switch modular 6 Amps , one way, 230 volts, 1 Module, complete all as specified and directed.
Supply and fixing socket modular 6 Amps , one way, 2/3 pin, 230 volts., two module, complete all as specified and directed.
Supply and fixing white cover plate 3 module, complete all as specified and directed.
Supply and fix modilar metal flush box 3 Module.
Servicing of water cooler of capacity 40 to 80 litres with washing chemical and warm water and replacing defective minor parts such as nut & bolts, PVC pipes and connected items complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs fan motor, single phase, 230 volts complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs thermostat, AC single phase, 230 volts complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs self-closing taps, 15 mm bore brass chromium plated complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs fan blade steel as per existing size complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs brass ball valve 25 mm size complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs float valve as per existing size complete all as directed by Engr-in-Charge.
Servicing of oil filled room heater with checking of power connections and repairing defective fins, replacing of control switches complete all as specified and directed
Supply & fixing as in repairs heating element of cap 1.5 KW of oil filled room heater complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs thermostat, AC single phase, 230 Volts of oil filled room heater complete all as directed by Engr-in-Charge.
Supply & fixing as in repairs of castor wheels for portability of oil filled room heater complete all as directed by Engr-in-Charge.
Taking up and refixing of power card after repairing of oil filled room heater complete all as directed by Engr-in-Charge.
Notes for items 31, 32 & 33. (i) Ensure equipment is clean where appropriate. (ii) Visual inspection of UPS. (iii) Check all re-set, where necessary relevant present adjustment. (iv) To rectify any apparent fault, where immediately possible, records other for later rectification. (v) To taking of electrical measurement to established the operation state of the UPS. (vi) Check setting of adjustable device (vii) Visual inspection of the UPS batteries. (viii) Checking for correct and accurate operation of all instruments
Supply only communication interface board (CIB) of 60 KVA UPS and replacing the board of proper make of existing at site with complete connection of existing cables with and CIB board making UPS running condition including taking down existing complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply only Communication Interface Board (CIB) of 80 KVA UPS and replacing the board of proper make of existing at site with complete connection of existing cables with and CIB board making UPS running condition including taking down existing complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply only Communication Interface Board (CIB) of 20 KVA UPS and replacing the board of proper make of existing at site with complete connection of existing cables with and CIB board making UPS running condition including taking down existing complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply only Monitoring unit Board and programming flashing of 60 KVA UPS , proper coy of make existing at site with complete connection through authorized operator of company including taking down existing complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply only Monitoring unit Board and programming flashing of 80 KVA UPS , proper coy of make existing at site with complete connection through authorized operator of company including taking down existing complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply only Monitoring unit Board and programming flashing of 20 KVA UPS , proper coy of make existing at site with complete connection through authorized operator of company including taking down existing complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply only Charger board of 80 KVA UPS including taking down existing complete all as specified and directed. Make : SOCOMEC/LIEBERT or as approved by GE.
Supply only Charger board of 60 KVA UPS including taking down existing complete all as specified and directed. Make : SOCOMEC/LIEBERT or as approved by GE.
Supply only Charger board of 20 KVA UPS including taking down existing complete all as specified and directed. Make : SOCOMEC/LIEBERT or as approved by GE.
Supply only SMF/VRLA type (Exide power safe plus ) sealed lead acid battery 12 volt 200 AH of existing make/model conecting each other, with suitable size of copper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and directed.
Supply only SMF/VRLA type ( Exide power safe plus ) sealed lead acid battery 12 volt 100 AH of existing make/model conecting each other, with suitable size of copper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and directed.
Supply only SMF/VRLA type (Exide power safe plus ) sealed lead acid battery 12 volt 65 AH of existing make/model conecting each other, with suitable size of copper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and directed.
Supply only SMF/VRLA type ( Exide power safe plus ) sealed lead acid battery 12 volt 42 AH of existing make/model conecting each other, with suitable size of copper plate/bracket as per existing place and including taking down old unserviceable battery or as recommended by manufacturer complete all as specified and directed.
Supply only IGBT board rectifier capacity 80 KVA UPS including internal hardware and software and making connection to the system for smooth functioning of UPS after taking out broken cabinet all as specified and directed. Make Emersion or as per OEM.
Supply only IGBT board rectifier capacity 60 KVA UPS including internal hardware and software and making connection to the system for smooth functioning of UPS after taking out broken cabinet all as specified and directed. Make Emersion or as per OEM.
Supply only IGBT board rectifier capacity 20 KVA UPS including internal hardware and software and making connection to the system for smooth functioning of UPS after taking out broken cabinet all as specified and directed. Make Emersion or as per OEM.
Taking out existing burnt fan motor single phase 230/240 Volt from the existing UPS capacity 60-80 KVA at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the following all as specified and as directed by Engineer - in - Charge.
Taking out existing burnt fan motor single phase 230/240 Volt from the existing UPS capacity 20 KVA at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the following all as specified and as directed by Engineer - in - Charge.
Supply only LED module assembly Major/Minor dome of OT Light complete all as specified and directed.. Model Dr Med LED 5030 double dome & Model Dentis lewis LED 5030.
Supply only head controller PCB of OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Supply only arm controller PCB of OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Supply only SMPS input/output harness of OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Supply only main PCB bracket of OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Supply only damper bolt OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Supply only Handle shaft assy of OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Fixing only for installation, testing and commisioning of Surgical Lights (OT Lights) from MES store yards to various locations of minor OTs of Command Hospital as marked by the user's including drilling in roof for suitable size of flange, nuts, bolts etc. including necessary electric connections from nearest electrical taping points and including necessary fittings and fixtures as per site requirement complete all as specified and directed by Engineer-in-Charge. Notes. (i) OT lights will be issued under Sch 'B' free for fixing. (i) Rates shall deemed to be included over all cost of necessary fittings & fixtures like flanges, nuts/bolts etc. (ii) Rates shall deemed to be included over all cost for necessary electric fittings and fixtures as per site requirement. (iii) Rates shall deemed to be included on over all cost for shifting of materials (OT lights) from MES store yards to fixing location (Comd Hosp). (iv) Submain wiring to be measured and paid separately in relevant schedule of item.
Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLSH copper conductor drawn through existing conduit including one run of single core 2.5 sqmm dia FRLSH PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. Notes:- (i) Two runs of 2.5 sq.mm copper conductor, one runs of 2.5 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
KAPOOR ENGINEERS (BID ID -3439872)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid