| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | ₹9.7 L Quoted ₹9.9 L | L1 | Accepted-AOC accepted |
| 2 | L2₹10.2 LRejected-Finance | ₹10.2 L | L2 | Rejected-Finance due to higher rate |
| Sl No | Description | Qty | Unit | BRAR PIPE INDUSTRIES L2 | Brar Construction Company L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. | 48.17 | cum | 200 ₹9,634 | 190 ₹9,152.30 |
| 2.00 | Construction of embankment with earth obtained from roadway cutting or excavation including spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications | 40.41 | Cum | 110 ₹4,445.10 | 105 ₹4,243.05 |
| 3.00 | Cement concrete 1:3:6 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type | 5.11 | Cum | 4,250 ₹21,717.50 | 4,200 ₹21,462 |
| 4.00 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded | 7.12 | sqm | 365 ₹2,598.80 | 360 ₹2,563.20 |
| 5.00 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. | 11.99 | CUM | 6,500 ₹77,935 | 6,450 ₹77,335.50 |
| 6.00 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth | 31.35 | cum | 6,500 ₹2.0 L | 6,250 ₹2.0 L |
| 7.00 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth | 19.07 | cum | 6,500 ₹1.2 L | 6,350 ₹1.2 L |
| 8.00 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) | 48.96 | cum | 230 ₹11,260.80 | 225 ₹11,016 |
| 9.00 | Centring and shuttering for slab of culverts for vent height up to 3.00 mtr | 66.89 | sqm | 650 ₹43,478.50 | 630 ₹42,140.70 |
| 10.00 | 12.5 mm thick cement plaster 1:4 | 263.6 | sqm | 210 ₹55,356 | 205 ₹54,038 |
Updated dates
Tender Value
₹9.3 L
EMD Value
₹18,656
Closing Date
4 Dec 2025, 10:00 amClosed
Executive Engineer
Executive Engineer, Bathinda Canal and Ground Water Division, Bathinda
ESTIMATE FOR CONSTRUCTION OF 1 HALL AND 1 ROOM FOR GONIANA ZAILADARI
2025_WR_154067_3
44/22A/2025-26
Open Tender
Civil Works - Canal
Bathinda
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹18,656
bathinda
22 Apr 2026
20 Nov 2025
4 Dec 2025
20 Nov 2025
4 Dec 2025
20 Nov 2025
26 Nov 2025
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Construction of embankment with earth obtained from roadway cutting or excavation including spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications
Cement concrete 1:3:6 with stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centring and shuttering for slab of culverts for vent height up to 3.00 mtr
12.5 mm thick cement plaster 1:4
Excavation of Soil using Hyraulic Excavator and hydraulic Tractor Trolly I/C cutting and loading in Trollyand transporting to the embankment locations with all lifts and leads Disposal/carraige from 0 upto 450m
Excavation of Soil using Hyraulic Excavator and hydraulic Tractor Trolly I/C cutting and loading in Trollyand transporting to the embankment locations with all lifts and leadsNO. Disposal/ carraige additional beyond 450m upto 1Km
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Supplying and fixingof Japani sheet frames(Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest),including iron lugs (hold fasts)iron hinges conforming to PWD specifications includingbolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame andcement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. ((a)) Doors and windows frame of size 118mm x 60mm with 40 mm wide singlerebate weighing 3.43 kg permeter.
White washing (two or more coat)
Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
WOOD WORK Deodar wood doors shutter windows shutter including hinges, screw and cords etc. Complete fixed in position ((a)) Panelled, glazed or glazed and panelled. ((i)) 40mm thick (Single Leaf)
FLOORING & DADOS Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile(a) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (a) Size 600x600 mm.
HOISTING, ROOFING AND WATER PROOFING Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on an
RECESSED HDPE PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked), overall 1.5sq. mm, 1100volts grade to be laid in HDPE electrical conduit pipe 20mm/25mm dia. ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, SteelHooks, Sheet metal fan box (1.6mm thick shapehexagonal), CI Circularjunction Boxes (Four way 1½" deep for walls and 3" deep forceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- ((i) b) Wiring fan point
Wiring call-bell point 1.00 Each
Wiring 6Amp. wall socket point
Wiring 16/20Amp. power plug control point
Wiring light point without control switch.
Wiring light point with double control switches
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:MCB Single Pole 6-32amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's asoutgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-) TP&N Horizontal Double Door Distribution Board 4 way each
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
BOQ_312091.xls
BOQ • 0.29 MB
TB03.xls
Additional Documents • 0.03 MB