Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-Finance | L1 | Accepted-Finance Accepted as per tender documents | |
| 2 | L2₹5.8 L+₹13,123 (2.30%)Accepted-Finance | L2 | Accepted-Finance Accepted as per tender documents | |
| 3 | L3₹6.0 L+₹28,988 (5.08%)Accepted-Finance | L3 | Accepted-Finance Accepted as per tender documents | |
| 4 | L4₹6.1 L+₹43,148 (7.56%)Accepted-Finance | L4 | Accepted-Finance Accepted as per tender documents |
Tender Value
₹6.3 L
Closing Date
10 Feb 2022, 3:00 pmClosed
Director
Deep Bhavan, D 372 by 2 Taratalla Road, Kolkata 700088
Provision of false ceiling light and electrical concealed wiring of Inspection Quarter including laying of new UG cable from distribution room to IQ and other Qtr. at Balasore Navtex Station, Odisha
2022_DGLL_669426_1
MS-KOL-04001/1/2019
Open Tender
Electrical Works
Works
45 days
Deep Bhavan, D 372 by 2 Taratalla Road, Kolkata 88
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
Deep Bhavan, Kolkata
3 Mar 2022
21 Jan 2022
11 Feb 2022
21 Jan 2022
10 Feb 2022
21 Jan 2022
28 Jan 2022
Supplying and fixing following size GI module box along with modular base & cover plate for modular switches in recess etc. as required.
2 Module (75mm * 75mm)
3 Module (100mm * 75mm)
4 Module (125mm * 75mm)
6 Module (200mm * 75mm)
8 Module (200mm * 75mm)
12 Module (200mm * 150mm)
Supply and fixing of metal box of following sizes in recess with suitable size phenolic laminated sheet cover in front including painting etc. as required.
100mmX100mmX60mm deep
150mmX150mmX60mm deep
Wiring for twin control light point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class pvc conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
10 Amp modular switch
2-way 10 Amp modular switch
20 Amp modular switch
3 pin 10 Amp 2- modular socket outlet
6 pin 20 Amp 2- modular socket outlet
TV antenna modular socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ hylam sheet including connections etc. as required.
Installation, testing, commissioning of wall bracket/ celling fittings of all sizes and shapes containing up to two GLS/CFL/LED surface/False ceiling light fitting complete with all accessories including connection etc as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Up to 300 mm Sweep
Supplying and fixing suitable size GI box (4-M) with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A, 2-M modular Starter including connection, painting etc as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in recess (Concealed) including cutting the wall and making good the same in case of recessed conduit as required.
25 mm pvc Conduit pipe.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed / PVC conduit as required.
3 x 1.5 sq. mm (11 coil of 90 mtrs.)
3 x 2.5 sq. mm (06 coil of 90 mtrs.)
3 x 4 sq. mm (05 coil of 90 mtrs.)
Supply and drawing co-axial RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with sheath in the existing surface/recessed / PVC conduit as required.
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 100A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
4 way (4 + 12), Double door.
Supplying and fixing following rating, four pole MCB, (three phase and neutral), 415 Volt in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 10A-3 nos, 16A-4 nos, 20 Amp- 3 nos
Double pole 32A
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of 10 sq mm & 2.5 sq mm UG cable direct in ground including excavation and refilling the trench etc as required, and end to end connection including Concrete path way cutting as required. (Trench size for soil - 300mm width X 300 mm depth) (Trench size for concrete-150mm width X 150mm depth) Distribution board to IQ- 180 mtrs. Distribution board to pump room- 100 mtrs. Pump room to Quarter- 60 mtrs. NA-II Quarter to vacant quarter- 80 mtrs. Pump room to LHA quarter- 80 mtrs. Pump room to office- 60 mtrs. Office room to security room- 60 mtrs.
Earthing with G.I earth pipe 4.5 meter long, 40mm dia including accessories, and providing masonry enclosure with cast iron cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15 mm diaG.I.Pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Supply of UG Cable, 4Core x 10 sq mm, Armored, Copper Conductor, HRPVC/ XLPE Insulation.
Supply of UG Cable, 3-Core x 2.5 sq mm, Armored, Copper Conductor, HRPVC/ XLPE Insulation.
Supply of LED 15 watt ultra slim round panel light.
Supply of 15 Watt LED surface light. Round.
LED foot light 4-Module with GI modular box..
Indicator 1-Modular.
Supply and fixing of 3-phase, 63 Amp, 440 volt TPN rotary Main switch with GI Box including connection.
Insulation Tape 5-mtr roll.
16 Amp, 3-pin Top.
LED mirror light, 5-watt, 1-feet.
4 inch round/square hylam sheet of 4mm thick. (Round- 10 nos. and Square- 10 nos)
PVC round Junction box, 1'', 2mm thick (1 to 4 way). 1-way-15nos, 2-way-20 nos, 3-way-15nos. 4-way- 10 nos.
Fan Rod with fixing clamp. 2.5 to 3 feet with clamp.
Labour charges for Removal and Re-Installation charges of electric Geyser with 1-set of hot and cold pipe. New Geyser installation- 01 no Old Geyser installation- 02 nos.
Labour charges for Removal and Re-Installation charges of 1.5 Ton split Air Conditioner units with stabilizer fixing including outdoor GI stand and drain pipe with wrapping tape complete. New AC installation- 02 nos Old AC installation- 02 nos.
Labour charges for cutting the gypsum board for light points in the false ceiling for fixing panel light.
Labour charges for removing of existing channel/Pipe wiring complete including switch board, pipes, fittings , MCB boxes etc.
MS SUJATA ENTERPRISE
BREEZE TUNE
JAGAJJIBAN DASH
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .