| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.3 L+₹4.8 L (13.2%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
26 Aug 2019, 6:00 pmClosed
GE(AF) Tech Area Maharajpur
GE(AF) Tech Area Maharajpur
REPAIR/MAINT OF DG SET, AMF PANEL/LT PANEL OF DG SET AND SPECIAL POWER SUPPLY IN TECH AREA/SINGPUR AT AF STN MAHARAJPUR
2019_MES_256265_2
8900/1174/MJR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(AF) Tech Area Maharajpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(AF) Tech Area Maharajpur
₹77,800
Yes
30 Jan 2020
24 Jul 2019
27 Aug 2019
24 Jul 2019
26 Aug 2019
3 Aug 2019
24 Jul 2019 - 17 Aug 2019
Amount
M/L for Maintenance and servicing of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M&L for changing of V-belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure , oil temprature , coolant temprature, frequancy , load current , battery charging , fuel consumption etc complete all as spicified and directed by Enginner in Charge for 7.5 KVA to 30 KVA D G set Make - Kirloskar/CG /Ruston/Cummins/ AhokA Leyland or any make .
All as per item No.1 here-in-before but for 40 KVA to 63 KVA DG Set Make :- Kirloskar/Cummins etc.
All as per item No.1 here-in-before but for 100 KVA to 125 KVA DG Set Make :- Kirloskar/Cummins etc.
All as per item No.1 here-in-before but for 160 KVA DG Set Make :- Kirloskar/Cummins etc.
All as per item No.1 here-in-before but for 200 KVA 250 KVA DG Set Make :- Kirloskar/Cummins etc.
All as per item No.1 here-in-before but for 320 KVA DG Set Make :- Kirloskar/Cumminsetc.
All as per item No.1 here-in-before but for 380 KVA to 400 KVA DG Set Make :- Kirloskar/ Cummins ,etc
All as per item No.1 here-in-before but for 500 KVA DG Set Make :- Kirloskar/ Cummins ,etc Note for BOQ Item No 1.00 to 8.00 1. Engine oil for refilling will be measured and paid Seprately 2. Coolant for make up will be measured & paid separately 3. DHPP will be issued by dept for testing and top up in tank only. 4. The Make of Fuel filter , Oil Filter , V belt & component will be as per existing or suitable make. 5. Replacement of unseriviceable part except which included in Item No 1.00 to 8.00 shall be measured and paid as supply only. Make of spare parts shall be same as existing.
Supply and fill lubricating oil for DG Sets all as specified and directed. Make: Castrol
Supply and fill coolant for radiator all as specified and directed. Make :- TVS
M/L for Servicing B-Check of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , fiter by pass ,super filter, fuel gasket lid gas check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separatobd sealing ring ling strip aeat sker ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M&L for changing of V-belts, checking of exhaust leakage, governor, breathers etc, adjust/set the sket ame for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure , oil temprature , coolant temprature, toltage , frequancy , load current , battery charging , fuel consumption etc complete all as spevidied and directed by Enginner in Charge for 320 KVA D G set Make - VOLVO PENTA E9,320 KVA AND DG NO -2 MODEL NO TAD 1351 GE,Sr No. 2013487101(320 KVA) Note :- 1. Engine oil for refilling will be measured and paid Seprately 2. Coolant for make up will be measured & paid separately 3. DHPP will be issued by dept for testing and top up only. 4. The Make of Fuel filter , Oil Filter , V belt & component will be as per existing or suitable make. 5. Replacement of unseriviceable part except which included in Item No 11.00 shall be measured and paid as supply only.Make of spare parts shall be same as existing.
Supply only Air filter main element for DG set 320 KVA of sterling make complete set all as per drected by Eng-in-charge
Supply only Air filter safety element for DG set 320 KVA of sterling make complete set all as per drected by Eng-in-charge
M/L for Servicing B-Check of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , fiter by pass ,super filter, fuel gasket lid gas check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separatobd sealing ring ling strip aeat sker ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M&L for changing of V-belts, checking of exhaust leakage, governor, breathers etc, adjust/set the sket ame for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure , oil temprature , coolant temprature, toltage , frequancy , load current , battery charging , fuel consumption etc complete all as spevidied and directed by Enginner in Charge for 250 KVA DG set Engine Make - VOLVO PENTA Model No. TAD754GE Sr No. 5311671946 (250 KVA) Note :- 1. Engine oil for refilling will be measured and paid Seprately 2. Coolant for make up will be measured & paid separately 3. DHPP will be issued by dept for testing and top up in tank only. 4. The Make of Fuel filter , Oil Filter , V belt & component will be as per existing or suitable make. 5. Replacement of unseriviceable part except which included in Item No 14.00 shall be measured and paid as supply only. Make of spare parts shall be same as existing.
Supply only Air filter main element for DG set 250 KVA of sterling Make : complete set all as per drected by Eng-in-charge
Supply only DSE 6 020 (Controller )for DG Set 250 KVA of sterling make complete all as directed by Eing-in-charge
Supply only AVR- R450 for DG set 250 KVA sterling make complete all as directed by Engineer-in-charge.
Supply onlymain Relay (part no.3171420) for DG set 250 kva steriling make complete all as directed.
Supply only varistor diode for DG set 250 /320kva control panel steriling make complete all as directed.
Supply only positive/ negative side diode for DG set 250/320 kva control panel steriling make complete all as directed.
Supply only Hose pipe set & Clips of water / coolent cooled radiator system for following D G set
15 KVA DG set to 30 KVA DG set
40 KVA to 63 KVA DG set
100 KVA to 160 KVA DG set
200 KVA to 250 KVA DG set
320 KVA DG set
380 KVA to 500 KVA DG set
Dismantling the water pump of the DG Set, taking out and replaceing with the worn out parts, refixing the water pump after repair and testing complete all as specified and directed for following D G set:-
Up to 50 KVA DG set.
62.5 KVA to 63 KVA DG set.
100 KVA to 125 KVA DG set.
200 KVA to 250 KVA DG set
320 KVA to 500 KVA DG set
Material and labour for servicing of self-starter assembly of DG Set ,by disconnecting the self starter assembly from the engine and dismantling the self-starter assembly for followiong DG set and cleaning all accessories , replace worn out parts like carbon brush, bush, contact plates, jumping leads etc and re-tapping the field coil and varnishing all as directed for following DG set :
7.5 KVA 30 KVA DG set
40 KVA to 63 KVA DG set
100 KVA to 160 KVA DG set
200 KVA to 320 KVA DG set
380 KVA to 500 KVA DG set
Material and labour for servicing battery charging alternators assembly of DG Set , by disconnecting from engine and dismantling the battery charging alternator assembly for follwing DG set cleaning all accessories replace worn out parts like carbon brush, bush/bearing , jumping leads etc, and varnishing all as directed
7.5 KVA to 30 KVA DG set
40 KVA to 63 KVA DG set
100 KVA to 160 KVA DG set
200 KVA to 250 KVA DG set
320 KVA to 500 KVA DG set
Disconnection and dismantling the fuel injector pump assembly from its original position & servicing by cleaning / oiling / servicing of fuel injector pump assembly , removing and replacement fuel injector pump repair kit & fuel pipe including calibration complete & refixing the same all as directed by Engineer-in-charge for following DG set :-
7.5 KVA to 30 KVA DG set
40 KVA to 63 KVA DG set
100 KVA to 160 KVA DG set
200 KVA to 320 KVA DG set
380 KVA to 500 KVA DG set
S&F in repair RPM meter on DG set complete all as specified and directed.
S&F in repair oil pressure Gauge on DG set complete all as specified and directed.
S&F in repair oil temperature Gauge on DG set complete all as specified and directed.
S&F in repair water temperature Gauge on DG set complete all as specified and directed.
S&F PVC insulated standard copper conductor cable 2 mtr length each soldered with 2 Nos brass battery terminals suitable for 120/150/180 AH 12 V DC battery complete all as specified and directed.
Supply and fix in repairs the following DG spares including testing complete all as directed by Engineer-in-Charge :-
AVR unit complete for 40 KVA to 100 KVA DG Set
AVR unit complete for 125 KVA to 200 KVA DG Set
AVR unit complete for 250 KVA to 320 KVA DG Set
AVR unit complete for 320 KVA 500KVA DG Set
Silicon Rectifier
Flexible rubber couping star type capacity alternator coupled with engine Make : Dunlop for 40 / 63 KVA
High pressure pipe complete set
Pipe assembly consisting of banjo bolt,copper washer,dual bango bolt ,leak of pipe etc.
Air cleaner
Diesel return pipe
Thermostate
Injector assembly
V Belt for fan radiator upto 500 KVA Set
Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 40 KVA to 63 KVA DG Set, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.
Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 100 KVA to160 KVA DG Set , strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.
Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 200 KVA to 250 KVA DG Set, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.
Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 320 KVA to 500 KVA DG Set, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.
Supply & fix in repair self starter assembly 12 volt compleate for 7.5 KVA to 63 KVA DG set
Supply & fix in repair self starter assembly 12 volt compleate for 100 KVA to 160 KVA DG set
Supply & fix in repair self starter assembly 24 volt compleate for 200 KVA to 320 KVA DG set
Supply & fix in repair self starter assembly 24 volt compleate for 380 KVA to 500 KVA DG set
Supply & fix in repair Fly wheel ring by removing alternator from engine for 50 Kva to 63 KVA DG set complete all as specified and directed.
Supply & fix in repair Fly wheel ring by removing alternator from engine for 100 KVA to 125 KVA DG set complete all as specified and directed.
Supply & fix in repair Fly wheel ring by removing alternator from engine for 200/320 Kva DG set complete all as specified and directed.
Supply & fix in repair Fly wheel ring by removing alternator from engine for 380 to 500 Kva DG set complete all as specified and directed.
Supply & fixing in repair fuel pipe assembly set for supply and returning complete all as specified and directed.
Supply & fixing in repair the turbo charger assembly complete of 40 KVA to 100 KVA DG Set complete all as specified and directed.
Supply & fixing in repair the turbo charger assembly complete of 125 KVA to 200 KVA DG Set complete all as specified and directed.
Supply & fixing in repair the turbo charger assembly complete of 250 KVA to 500 KVA DG Set complete all as specified and directed.
S & F following items in AMF Panel of any description and in any position of capacity DG Set upto 500 KVA including checking AC/DC circuits, tightning of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to make AMF functional inclusing testing complete all as specified and directed.
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla make or equivalent of Eagle man.
Pla relay 12 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -12D of pla make or equivalent of Eagle man.
Ammeter size 96 mm X 96mm, flush mounted digital type, three phase of class 1.0 complete all as specified and directed. Make: HPL / Rishab / MECO / Schneider.
Voltmeter size 96 mm X 96mm, flush mounted digital type, three phase, class 1.0 complete all as specified and directed. Make: HPL / Rishab / MECO / Schneider.
Frequency meter size 96 mm X 96mm, flush mounted digital type, three phase, class 0.2 complete all as specified and directed. Make: HPL /Rishab / MECO / Schneider.
Under voltage relay suitable for 3 phase 415 volts, AC supply complete all as specified and directed. Make: PIC / Aditya Electronic
Engine starting relay with sequence timer & master timer suitable for 12 / 24 Volts DC supply complete all as specified and directed. Make: PIC / Aditya Electronic
Electronic timer, time range from 3 seconds to 10 seconds , suitable of 12/ 24 Volts, 50 Hz, AC supply complete all as specified and directed. Make : L&T / PIC / Aditya Electronic.
Rectifier 4 plates, single phase, having charging rate 15–20 Amp per minute for 12/24 Volts DC battery charge complete all as specified and directed. Make : Usha / URI / Kirloskar.
Rectifier 8 plates, single phase, having charging rate 15–20 Amp per minute for 12/24 Volts DC battery charge complete all as specified and directed. Make : Usha / URI / Kirloskar.
LED Indicator 22.5mm for 12 /24 volts AC/DC supply complete all as specified and directed. Make: L&T/ BCH / Seimens / ABB.
Battery charging transformer 0 to 10 Amperes, 12 Volts DC tapping 0-12-18-24 Volts complete all as specified and directed.
MCB single pole, 10 KA, rating 6 to 32 Amps ‘C’ series, 240 volts complete all as specified and directed. Make :Legrand /Siemens / BCH/ /ABB/Havells/Standrd.
S&F in repair including testing of Power contactor , of following capacity, for 415 Volt AC supply complete all as specified and directed :-
Power contactor 3 pole, AC3 rating of 630 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/GE
Power contactor 3 pole, AC3 rating of 580 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/L&T/Havells
Power contactor 3 pole, AC3 rating of 500/550 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/L&T/Havells
Power contactor 3 pole, AC3 rating of 400 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/L&T/Havells/TC
Power contactor 3 pole, AC3 rating of 325 Amps, with 2 NO + 2 NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : L&T MNX 325 / Siemens / BCH/ Schneider/Havells.
Power contactor 3 pole, AC3 rating of 210 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make :ABB / Siemens / BCH/ Schneider/L&T/Havells
Power contactor 3 pole, AC3 rating of 200/225 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/L&T/Havells/TC
Power contactor 3 pole, AC3 rating of 185 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/L&T/Havells
Power contactor 3 pole, AC3 rating of 110/125 Amps, with 1NO + 1NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : ABB / Siemens / BCH/ Schneider/L&T/Havells .
Power contactor 3 pole, AC3 rating of 110 Amps, with 2 NO + 2 NC auxiliary contacts for AC circuit, 415 Volts complete all as specified and directed. Make : L&T MNX 110 / Siemens / BCH/ Schneider/Havells.
S&F in repair including testing of MCCB, of following capacity, having adjustable thermal magnetic release for 415 Volt AC supply complete all as specified and directed :-
MCCB, 4 pole, 100 Amps, breaking capacity Icu = 25 KA. Make: ABB /Legrand/ Havells/ C&S/L&T/Schneider
MCCB 3 pole, 125 Amps, breaking capacity Icu = 25 KA. Make: ABB / Legrand / Siemens / Havells /C&S/L&T/Schneider
MCCB, 4 pole, 160 Amps, breaking capacity Icu = 36 KA. Make: ABB / Legrand / Siemens /Havells /C&S/L&T/Schneider
MCCB, 4 pole, 200 Amps, breaking capacity Icu = 36 KA Make: ABB / Legrand / Siemens / Havells /C&S/L&T/Schneider
MCCB, 4 pole, 250 Amp, breaking capacity Icu = 35 KA, Make: ABB / Legrand / Siemens / Havells /C&S/L&T/Schneider
MCCB, 4 pole, 315/320 Amp, breaking capacity Icu = 35/36 KA, Make: ABB / Legrand / Siemens / Havells /C&S/L&T/Schneider
MCCB, 4 pole, 400 Amps, breaking capacity Icu =50 KA Make: ABB / Legrand / Siemens / Havells /C&S/L&T/Schneider
MCCB, 4 pole, 630 Amps, breaking capacity Icu = 50 KA Make: ABB / Legrand / Siemens / Havells /C&S/L&T/Schneider
S&F in repair including testing of ON LOAD change over switch of 630 Amp capacity 4 pole for 415 volts complete all as specified and directed . Make: C&S / HPL / L&T / Havells/Legrand.
S&F in repair including connecting and testing of change over switch OFF LOAD type in sheet metal enclosure with side handle operation of following capacity, 415 volts, AC supply confirming to IS : 13947( Part I & III ) complete all as specified and directed :-
Change over switch OFF LOAD type 400 Amp, 4 pole. Make:- Havell's / HPL / L&T/C &S / Legrand.
Change over Switch OFF LOAD type, 320 Amps, 4 pole. Make:- Havells/ HPL / L&T / C&S/Standard.
Change over Switch OFF LOAD type, 200 Amps, 4 pole. Make:- Havells/ HPL / L&T / C&S/Standard.
Change over switch OFF Load type 100A, 4 pole. Make:- Standard / Havells/HPL/L&T/ C & S/.
Change over switch OFF Load type 63A, 4 pole. Make:- Standrad / Havells/HPL/L&T/C & S.
S & F in repair governor control unit for electronic governor suitable for Kirlosker / Cummins Make DG Sets of capacity upto 125 KVA
S & F in repair governor control unit for electronic governor suitable for Kirlosker / Cummins Make DG Sets of capacity 160 to 250 KVA
S & F in repair governor control unit for electronic governor suitable for Kirlosker / Cummins Make DG Sets of capacity 320 KVA to 500 KVA
S&F in repair Actuator ETR fuel control unit of cummins/Kirloskar make DG sets of 380-500 KVA capacity complete all as specified and directed.
S&F in repair Control instrumentation panel for cummins/Kirloskar make DG sets of 380-500 KVA capacity complete all as specified and directed.
S&F in replacement engine electronic (instrumentation) digital panel comprising of starting switch ON/OFF water temp display, hour meter cum RPM display, lubricant oil pressure display, lubricant oil tempreture display, battery charing display, safety alarm against high water temp and lubricant oil pressure for cummins/Kirloskar make DG Set of 250-500KVA capacity complete all as specified and directed
Dismantling of alternator assly of DG Set and taking out U/S Exitation winding and rewinding of excatation coil with supper enamelled copper winding all as per specified and directed. 200 KVA to 400 KVA.
M&L for repairing of canopy of DG set by carrying out repairing of door with replacement of broken hinges including nuts, bolts/welding etc as per requirement, cleaning of base of foundation and painting with black paint MS channel with two coats including touching of paint at cannopy where required complete all as specified and directed
S&F in repair lead acid battery DC 12 Volts, 150 AH complete all as specified and directed. Make - Exide/Amron/Sonic.
S&F in repair lead acid battery DC 12 Volts, 180 AH complete all as specified and directed. Make - Exide/Amron/Sonic. Note for item No 61 & 62:- Old unserviceable battery shall be deposited to AGE(E/M) Store yard.
Material and labour for dismantling and taking out and rewindind of Alternator stator assembly of 160 KVA DG Set and rewinding of approved suitable gauge super enamel insulated copper winding wire with necessary insulating materials reassembling and transportation to workshop and bring back to orgins at installation and fixing,testing and commissioning complete all as specified and directed by Eng-in-charge.
All as per item No. 63 as avove 20 KVA Alternator and exiting coil all as per directed by Engg-in-charge
M & L for disconnecting taking out excitation coil 125 KVA Alternator and Exeatation winding and rewinding of excatation coil with super enamelled copper winding wire of same gauge quanity,assembling of alternator, refitting and testing complete all as specified and directed.
Materal and labour for spray painting of old painted sarfaces of DG Set 200KVA and spray painting with approvd colour synthetic enamel paints including basechannel complete all as directed by Eng-in-charge.
All as item No. 66 as above but 125 KVA DG Set
M/s Yashika Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .