LT COL BIJENDER SIDHU
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8375 INSTALLATION OF ELECTRIC FENCING AT INDQ
2026_MES_796534_1
8375/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹77,580
Yes
31 Oct 2026
31 Oct 2026
23 Nov 2026
31 Oct 2026
21 Nov 2026
14 Nov 2026
31 Oct 2026 - 13 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and installation of Special Profile Posts for fixing of electric fence as per following :- Note : (i) Posts should be of varying dimensions and profiles based on the site requirement. (ii) All poles shall have protective layer of coating durable for C5 environmental conditions i.e. Thermoplastic Powder coating of min.250 Microns over structure items. (iii) The OEM shall provide Type Test Certificate for sample testing of 1440 Hrs Salt Spray Test from reputed agencies like CSIR. (iv) The OEM shall have a valid applicator certificate from powder manufacturer Axalta as per PPA 571 ES grade for Thermo plastic coating using Electro static spraying method. (v) The OEM should have in-house plant and machinery for manufacturing and powder coating (Automated convey based electrostatic spray coating mechanism for consistent and uniform coating to meet the longevity of the coated components). (vi) The Square hollow section material shall be as per IS 4923:1997 YST(Yield Strength Tensile) of 210MPa Standard Specs Applicable for Straining posts. (vii) The Equal Angle material shall be as per IS 2062:2011 Grade E250 for Intermediate posts & Diagonal posts. The posts should be as follows: | |||||
| 1.01 | Straining posts for NAMAC Side:
Material and labour for strain poles comprises of following : Strain poles to be installed not more than 30 metre apart and at every corner and discontinuity including firmly fixing to the wall by a base plate and all holes in the sections shall be pre-drilled before galvanising/coating. The details are as under :-
Section: 40 x 40 x 3 mm,Square Hollow Section (SHS)
Height: 1500 mm above wall/Concertina Coil (NAMAC Side) (Design and height as per drawing submitted by OEM)
Pole fixtures should be according to the site conditions or as per drawing.
Powder Coating : The galvanised strain poles are subsequently Thermoplastic coated with a thickness of minimum 250 microns. Colour: Green (RAL 6005)
Coating Standard: As per EN 10245-1/ IS 13871 | 7 | Each | 1 | ₹7 |
| 1.02 | Intermediate posts for NAMAC Side:
Material and labour for intermediate poles comprises of following : Itermediate poles to be installed at max 3.0 metres from each other and intermediate posts must be firmly fixed to the wall by a base plate. All holes shall be pre-drilled before galvanising/coating.
Section: Equal Angle 40x40x4 mm
Height: 1500 mm above wall/ Concertina Coil (NAMAC Side) (Design and height as per drawing)
Powder Coating : The galvanised intermediate poles are subsequently Thermoplastic coated with a thickness of minimum 250 microns.
Colour: Green (RAL 6005)
Coating Standard: As per EN 10245-1/ IS 13871 | 15 | Each | 1 | ₹15 |
| 1.03 | Diagonal posts for NAMAC Side:
Material and labour for diagonal posts comprise following : Each Strain pole must be supported by 2 diaginal support Poles.
Section: Equal Angle 40x40x4 mm (Design and height as per drawing)
Pole Fixtures should be according to the site conditions.All holes shall be pre-drilled before galvanising/coating
Powder Coating : The galvanised support poles are subsequently Thermoplastic coated with a thickness of minimum 250 microns.
Colour: Green (RAL 6005)
Coating Standard: As per EN 10245-1/ IS 13871 | 14 | Each | 2 | ₹28 |
| 1.04 | Straining posts for other 3 Sides:
Material and labour for other 3 sides strain post comprises of following : Strain poles shall be installed not more than 30 metre apart and at every corner and discontinuity. Strain poles must be firmly fixed to the wall by a base plate. All holes in the sections shall be pre-drilled before galvanising/coating
Section: 40 x 40 x 3 mm,Square Hollow Section (SHS)
Height: 1500 mm above wall (Design and height as per drawing)
Pole fixtures should be according to the site conditions or as per drawing.
Powder Coating : The galvanised strain poles are subsequently Thermoplastic coated with a thickness of minimum 250 microns.
Colour: Green (RAL 6005)
Coating Standard: As per EN 10245-1/ IS 13871 | 16 | Each | 3 | ₹48 |
| 1.05 | Intermediate posts for other 3 Sides:
Material and labour for other 3 sides inermediate posts comprises of following : Intermediate poles shall be installed at max 3.0 metres from each other. Intermediate posts must be firmly fixed to the wall by a base plate. All holes shall be pre-drilled before galvanising/coating.
Section: Equal Angle 40x40x4 mm
Height: 1500 mm above wall (Design and height as per drawing)
Powder Coating : The galvanised intermediate poles are subsequently Thermoplastic coated with a thickness of minimum 250 microns.
Colour: Green (RAL 6005)
Coating Standard: As per EN 10245-1/ IS 13871 | 30 | Each | 4 | ₹120 |
| 1.06 | Diagonal posts for other 3 Sides:
Material and labour for diagonal post for other 3 sides comprises of following :- Each Strain pole must be supported by 2 diagonal support poles.
Section: Equal Angle 40x40x4 mm (Design and height as per drawing)
Pole Fixtures should be according to the site conditions.All holes shall be pre-drilled before galvanising/coating.
Powder Coating : The galvanised support poles are subsequently Thermoplastic coated with a thickness of minimum 250 microns.
Colour: Green (RAL 6005)
Coating Standard: As per EN 10245-1/ IS 13871 | 32 | Each | 5 | ₹160 |
| 2 | Supply and installation of fence wires comprises of following :- The fence wires should be high tensile SS316 wires shall be used as fence wire.
Diameter: 2.50 mm, Material Of Construction: High Tension
Tensile Strength: 135 kg/sq.mm min. | 95 | Kg | 6 | ₹570 |
| 3 | Supply and installation of appropriate insulators for insulating the poles from the live wires comprises of following:
Jumbo Strain insulators shall be used for Corner & Strain poles.
Y-Standard insulators shall be used for Intermediate poles.
Insulators must be strong enough to take the load of the wires.
Y-Standard Insulators should be designed to break under vertical load of 25-30 Kgs.
All the insulators shall be made of UV stabilised plastic. | 1,055 | Each | 7 | ₹7,385 |
| 4 | Supply and installation of wire tightener i.e. combi-tensioner and S-hook which is to be used in between the end of wire and strain poles including fixing on the pole through the S hook and take the load of the entire wire. Combi Tensioner will insulate the post from the wire and have a simple tightening mechanism to tighten the wire with a simple tool. | 1,035 | Each | 8 | ₹8,280 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
8375TENDERDOCUMENTS.pdf
Tender Documents • 1.84 MB
BOQ_893592.xls
BOQ • 2.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .