Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹59,264Accepted-Finance | I | Accepted-Finance accept | |
| 2 | II₹61,224.50Accepted-Finance B 2 C 11 SECTOR M KURSI ROAD ALIGANJ LUCKNOW UTTAR PRADESH 226024 | LUCKNOW | UTTAR PRADESH | 226024 | II | Accepted-Finance accept | |
| 3 | III₹63,967Accepted-Finance | III | Accepted-Finance accept |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
8 Apr 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER CIVIL UNIT
EXECUTIVE ENGINEER CIVIL UNIT 913 9TH Floor Shakti Bhawan Extn Lko
Sepage treatment Work of Toilets situated (4.00 Nos toilet) in A.C. Hostal Bulding at ETI Sarojini Nagar Lucknow
2021_UPPCL_577474_1
33(2)/EE(C)U/SBE/LKO/2020-2021
Open Tender
Civil Works - Others
Item Wise
120 days
Sepage treatment Work of Toilets situated (4.00 No
Please refer Tender documents.
2 documents required · 2 mandatory
₹296
EXECUTIVE ENGINEER CIVIL UNIT
₹2,000
12 Apr 2021
27 Mar 2021
8 Apr 2021
27 Mar 2021
8 Apr 2021
27 Mar 2021
60 days
Amount
Laying and Jointing PVC Pipe. Heading
Cement concrete with 2cm gauge approved hard stone ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 4:2:1 including supply of all materials,labour,side shuttering if required and T&P etc. required for proper completion of work.
S/Mixing approved water proofing compound(CICO,DR FIXIT etc) in cement mortar in plaster or concrete work in the Proportion as recommended by the manufacture .
Supply and Laying 8 mm thick glazed floor tiles of Somany , Johnson or equivalent make, of size 300x300 mm, laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials, labour and T&P etc. required for proper completion of the work.
Supply and Laying 6 mm thick glazed tiles of size 300x450 mm in skirting / dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete,including supply of all materials, labour and T&P etc. completion required for proper completion of the work.
One priming coat and one coat oil bound distemper on previously old oil bound distemperwork including supply of all materials,labour and T&P etc. required for proper completion of the work.
As in item 5 but for every coat after the first coat.
Applying BIRLA PUTTY or equivalent putty on previousaly birla putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work.
Repair to plaster or pointing in patches including removal of old plaster racking out joints to 1 cm.(3/8") depth, watering the area and then replastering or reappointing with the same mortar or proportion of mortar as the existing surface including supply of all materials, labour and T&P etc. required for proper completion of the work add to the respective items in chap.11 (Plaster and Pointing).
Supply and fixing 100 mm PVC Nahani Trap India make of heavy approved quality complete with CI grating, including supply of all materials,labour and T&P etc. required for proper completion of the work.
Providing and laying 110 mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Dismantling of tile, CC Floor and sunken of toilet and including stacking of materials as directed by the Engineer-in-charge within a distance of60 metres.
Supply and filling cinder in sunken floor in 15 cm layers including cost of all labour and T & P etc required for proper completion of the work.
Raking of tile joint and Filling apoxy grount and grouting of nahani trap etc as required including cost of all labour and T & P etc required for proper completion of the work.
M/S KALPANAM CONCEPTS
AAKRITI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .