Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹7.4 L+₹53,558 (7.81%)Rejected-Finance 1 215 BHOOSA MANDI FATEHGARH FATEHGARH FARRUKHABAD UTTAR PRADESH 209601 | FARRUKHABAD | UTTAR PRADESH | 209601 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹7.5 L+₹63,348.80 (9.24%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | 4₹7.5 L+₹68,532.20 (10.00%)Rejected-Finance 05 BABA PALACE MUSRIGHARARI JANDAHA ROAD MUSRIGHARARI SAMASTIPUR BIHAR 848101 | SAMASTIPUR | BIHAR | 848101 | 4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | 5₹7.7 L+₹84,792 (12.4%)Rejected-Finance | 5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹9.6 L
EMD Value
₹18,600
Closing Date
29 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Fatehgarh
AGE(I) Fatehgarh
SPL REPAIR TO BLDG No P 255 (COOK HOUSE) OF 431(I) SUP PL ASC SUPPLY DEPOT FATEHGARH CANTT
2021_MES_497221_1
AGE(I)/FAT/ET-51 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
REFER TENDER DOCUS
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹18,600
Yes
24 Mar 2022
30 Dec 2021
2 Feb 2022
30 Dec 2021
29 Jan 2022
15 Jan 2022
30 Dec 2021 - 14 Jan 2022
90 days
Amount
Demolition of reinforced cement concrete of any description and in any position including cutting of reinforcement, if required complete all as specified and directed.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping & benching complete all as specified and directed.
M&L cement concrete type B-1, 1:2:4 set in C:M 1:4 in, lintel,kitchen slabs etc. complete all as specified and directed.
M & L mild steel TMT bars 6 to 8mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each not exc 4.00 sqm each.complete all as specified and directed.
S & F Anodised aluminium frame work for window/ventilator made out of approved section incl providing necessary joining cleats,glazing clips,rubber packing,anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long ( 1 No.) hinges type B-21 100 mm long (2 no.) suitable handle(1 No.), 100mm long tower bolt (02 Nos) (all fittings per leaf) complete all as specified and directed. Note:- Fabrication work shall be got done by approved fabricator or manufacturer of aluminium.
S & F Anodised aluminium frame work for door made out of approved section incl providing necessary joining cleats,glazing clips,rubber packing,anodised aluminium snap beading screws, anodised aluminium fittings such as hinges type 150 mm long (3 no.) suitable handle(2 No.), 150 mm long tower bolt (02 Nos) (all fittings per leaf) complete all as specified and directed.
S&F sheet glass 4.8 mm thick ordinary quality exc 0.5 sqm each complete all as specified and directed.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill toproper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed.
S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Built in steel Cupboard (shutter and frame) of pressed steel frame of size 75mm x45mm x1.25 mm thick with pressed steel shutter 1.00mm thick Godrej Pattern fixed to masonary walls by hold fast made out of 25 x 3 mm FI embeded in PCC 1 :2 : 4 type B1 complete, incl two coats of spray painting over a coat of red oxide primer on steel surfaces,including hinges,handle/lock godrej pattern, complete all as specified and directed.
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material of out side MD land complete all as specified and directed.
Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc. but including concrete articles complete all as specified and directed.
M & L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed.
-ditto- all as per above but except Bricks etc complete all as specified and directed.
M&L half brick thick walls built in CM 1:4 Sub Class B bricks straight or curved on plan to any radius complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed.
M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of chalk whitening complete all as specified and directed..
M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M & L for preparation of old plastered surfaces of walls by rubbing down and making surface smooth and applying two coats of OBD complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls by rubbing down and making surface smooth and applying two coats of cement base paint complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving n.exc 15cm thickness (below or above ground level) etc complete all as specified and directed.
S & F Vitrified Ceramic Tiles 10 mm thick (Square/rectangular) light shade polished area of each tiles not exceeding 0.36 sqm in floors and skirting etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match incl 15 mm thk screed bed in CM 1:6 complete all as specified and directed.
M & L Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors,skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer of cement (1:6) complete all as specified and directed..
M & L Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450x 350x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
18-20 mm th Granite (of any type) work (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over 15 mm th screed in CM 1:6 complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for machine cut kota stone slab as in stair case riser and skrting/dado 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for providing prepolished chequered cement concrete tiles of size 20cm x 20cm x 25mm thick set & jointed in neat cement slurry with grey cement and pigment including 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying of chequered tile complete all as specified and directed.
M & L 50 mm thick PCC 1:3:6 type C-2 using 40mm graded aggregateds as in plinth protection, subbase of floors complete all as specified and directed.
M & L 75 mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in floors etc complete all as specified and directed.
Dismantaling of asbestos cement (Corrugated, semi corrugated etc) sheetiting in roof covering complete all as specified and directed.
Dismantling framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesconforming to Fe 410-W (Gde E-250) quality B complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed up, capacity in 1000 Ltrs, hoisted and fixed in position with all fittings and fixtures including float valve 20 mm bore in position complete all as specified in SSR Part-I complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F False Ceiling Horizontal level regular edge grid 600 x600 mm from work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6 to 8mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab all as per manufactured instruction complete all as specified and directed.
S&F in repair Vitreous China Wash Basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets , 32 mm PVC waste pipe, 32 mm PTMT Waste coupling and 15 mm dia Pillar taps fancy type chromium plated complete all as specified and directed
S&F in repair Vitreous China Wash down water closet pedestal patteren white with platic seat cover including Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook complete all as specified and as directed .
S&F in repair Low Level Flushing System PVC valveless syphonic action type, 10 ltrs capacity white, with inlet, ball float and handle including brackets complete all as specified and directed.
S&F 15 mm bore GI pipe medium grade ISI marked with all fittings and fixed to walls/roofs or laid in floors/plinth protection including making good disturbed surfaces with cement mortar (1:3) to match with existing surfaces including dismantling of old pipe complete all as specified and directed.
S&F 20 mm bore GI pipe medium grade ISI marked with all fittings and fixed to walls/roofs or laid in floors/plinth protection including making good disturbed surfaces with cement mortar (1:3) to match with existing surfaces including dismantling of old pipe complete all as specified and directed.
S&F in repair 15mm bore Chromium plated Bib taps fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore ,Stop valves, cast copper alloy,screwed down, high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed fancytype, chromium plated with long shank and cup(concealed type)complete all as specified and directed.
S&F in repair 15 mm bore ,Stop valves, cast copper alloy,screwed down, high pressure, with crutch or butterfly handle,screwed both/one ends for iron pipe or for unions and fixed fancy type, chromium plated complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed.
S & F in repairs brass chromium plated showe rose 125mm size with shower arm complete all as specified and directed.
S & F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repair PTMT grating doom 100mm dia with or without waste hole etc complete all as specified and directed.
S&F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames glazed with putty of fixed with beads complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S & F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples, wodden beads to steel windows/wodden doors complete all as specified and directed.
Taking down copper/aluminium point wiring of any discrapation and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed
M&L for point wiring of One light/fan/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit of suitable size medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
…..ditto as above but for one 5 pin 5 Amp switch socket combination point on an independent board…ditto…..
…..ditto as above but for one 5 pin 5 Amp socket point controlled by one switch on same board…ditto…..
…..ditto as above but for one 15 Amp 6 Pin switch socket combination independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded …..ditto……
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F switch socket combination 5 Amp 5 Pin complete all as specified and directed.
S&F switch socket combination 5 in 1 flush type 5/15 Amp complete all as specified and directed.
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings incl LED lamp of 9 W and colour temp 6500K suitable to fix in angle hoder complete all as specified & directed.
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm FRLS and one run of 04 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing in replacement MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified.
S&F in replacement of MCB SPN 16-40 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F in replacement of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F surface and wall mounted 18/20W LED extruded aluminium batten fiitting provided for efficient heat dissipation complate all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. (Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S SRI JAGDAMBE TRADERS
MS. BK BROTHERS AND CO
M/S BABA CONSTRUCTION
M/s Moti Babu Agarwal
M/S S P CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .