Development of High School Dara by way of Fencing/ Boundary walling etc.
2026_RDPR_302938_1
ENIT49/REW SRG 2025-26
Open Tender
Civil Works
Percentage
SRINAGAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,200
Rural Development and Panchayati Raj
₹33,760
18 Feb 2026
12 Feb 2026
18 Feb 2026
12 Feb 2026
17 Feb 2026
12 Feb 2026
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
Providing and laying of Stone Soling duly hand packed in trenches incl. compaction with hand ramming and carriage
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) with carriage, Complete job.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete, 40mm thick with 20 mm nominal size stone aggregate incl. carriage
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
Pointing on stone work with cement mortar 1 : 3 (1 cement : 3 fine sand) Flush/Ruled Pointing
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks. From brick work in cement mortar
Brick work with common burnt clay (non-modular) bricks of class designation 7.5i n superstructure above plinth level upto floor V level including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) incl carriage
Engagement of Labour for laying Bricks (Available at Site) in superstructure above plinth level upto floor V level including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): KD WOOD
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.22.1 With ISI marked M.S. pressed butt hinges bright finished of required size and neccesary screws and hardwear fittings, complete in all respects. 35mm
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : KD WOOD
Renewing glass panes and re-fixing existing wooden fillets: Float glass panes of thickness 4.0 mm (weight not less than10kg/sqm)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 3mm
Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer incl scraping of old paint where required
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) incl. scraping of old paint where required
Painting with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer with readymixed red oxide and zinc chromate of approved brand and manufacture.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/sqm
Wiring for Group Controlled light points(3 lights on one switch) with 1.5.sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in existing surface /recessed medium class PVC conduit ,with modular switch(Anchor roma urban /eq.make),base plate ,cover plate ,suitable modular PVC box required (Havells /Legrand/roma urban/Eq.make as par ISI Standard Note ThePVC boxes can be of different sizes of Modulues to hold the Modular Boxes and Modular Switches for lights/fans/exhaust fans and are included in the point rate
Supply ,fixing,drawing testing and commissioning of 3x2.5 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC conduit. Note This includes Three wires (Phase , Neutral and earth ) and 1 Ckt meter is equivalent to 3 meters
Supply ,fixing,drawing testing and commissioning of 3x4 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC conduit Note This includes Three wires (Phase,Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply of fixing of 25 mm size PVC channel along with accessories(bends,sockets,iron staples/saddles/screws,pvc fastener etc) in surface
Supply of fixing of Suitable PVC Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 15/16 amp /230 V AC modular socket and 15/16 amp modular switch(Anchor Ro urban/SSK NV/Havells /Eq.make)
Supply of fixing of Suitable PVC Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 5/ 6 amp /230 V AC modular socket and 5/6 amp modular switch(Anchor Ro urban/SSK NV/Havells /Eq.make)
S/F testing nd comm..of recessed /surface mounted 8-10 watt LED down lighters SMD type system Luman efficacy >= 100<120 lm/watt Philips /havalles /bajaj/Crompton make of eq. standards
SITC of 20 watt LED Flood Lights of standard make (Complete Job)
Suppling and fixing of 8 way horizontal type single pole and neutral sheet steel,MCB distribution board ,240 V ,On surface /recess,complet with neutral bus bar,earth bar,din bar interconnection ,powder painted including earthing etc .as required .(But with out mcb/ Rccb/Isolator ):-Hager /Legrand /ssk/equt .standard
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 6-32 Amp SP MCB
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 40-63 Amp DP MCB
SITC of 100 amp 4 way Connectror including Providing of 3x10sqmm FRLS cu wire(2 Ckt mtr=6 meter) from Mains DB to Connector to be installed outside the building
Earthing with GI earth Pipe 2.15 metre long (1 Nos) ,40 mm dia including charcoal/coke/salt as required along with 6 SWG GI Wire /25X3 mm GI Strp upto the nearest point of earth to be supplied/drawn from Main Power distribution Board and connecting the same (Complete Job) as per the directions of engineer incharge
Add provision for cost of signboard photographs and other unforeseen items etc. (STA)
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.23 MB
BOQ_983174.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .