Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | Admitted-Finance |
| 3 | Admitted-Finance 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | Admitted-Finance |
Tender Value
₹96.0 L
EMD Value
₹1.9 L
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112 Taj Road Agra Cantt
ADDN / ALTN TO BLDG NO. P-06 UNDER GE (WEST) AGRA
2022_MES_538739_1
84259/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class C category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE West Agra
₹1.9 L
Yes
2 Sept 2022
16 Jul 2022
26 Aug 2022
16 Jul 2022
20 Aug 2022
6 Aug 2022
16 Jul 2022 - 23 Jul 2022
Amount
Excavation in trenches n exc 1.50 m depth for foundation and getting out in soft/loose soil complete all as specified and directed
M & L Plain Cement concrete, type D-2(1:4:8) (using 40mm graded stone aggregates) as in foundations, filling and mass-concrete complete all as specified and directed
M & L for Returning , filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
M & L for Removing excavated soil exc 250m but n exc 500m and depositing where directed at a level n exc. 1.5 m complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) sub base for floors finished and fair complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as sub base for floors finished and fair complete all as specified and directed
M&L for 20-25 mm thick Machine cut kota stone slab flooring over 20mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M & L RCC 1:2:4 Nominal mix (using 20mm graded stone aggregate) for foundations, incl rafts, footings, foundations beams , plinth beams, bases for columns etc complete all as specified and directed
M & L RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) Nominal mix for Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed
Formwork to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffitsn(if any) of foundation and similar work vertical or to batter complete all as specified and directed
Formwork to sides and soffits of floor or roof beam, bem haunchings, girders, bressummers, lintels, cantilevers etc complete all as specified and directed
M&L for rolled MS roof trusses (Framed), trussed , purlines, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel of flat sections including distance pieces, clets etc) confirming to Fe-410-W (Gde-E-250 quality B) complete all as specified and directed
Demolition of cement concrete (unreinforced) in any position n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed
Disposal of removed/demolished soil/materials exc 1.50 km but n. exc 5 km and depositing where directed complete all as specified and directed
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with CM 1:3 or PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) complete all as specified and directed.
Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in benching, coping , roof kerbs, mud stop etc and similar work including all necessary form work complete all as specified and directed
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry @ minimum 9 kg cement / sqm and pointed in white or colour cement to match tiles with cement plaster over & including 10mm thick rendering in CM 1:4 on brick wall & prepare the surface to received the tiles complete all as specified and as directed .
M&L glazed ceramic non skid joint free coloured tiles (1st quality/premium quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqm as in floors, skirtings etc set and jointed in neat cement slurry @ minimum 3 kg cement / sqm and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.
M&L for vitrified ceramic light or any shade of tiles 10mm thick (square /rectangular), polished (Ist quality/Premium quality), area of each tiles n.exc 0.36 Sqm in floors etc, laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry @ minimum 3 Kg / Sqm and pointed in white or coloured cement to match the shade of tiles, including skirting, complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) ,complete all as specified and directed
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound @ manufacturers instructions finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
M & L for rendering 10mm thick in CM 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for applying three coats of white wash on wall including preparation of new plastered surfaces of walls, complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of new plastered surfaces, complete all as specified and directed.
M&L for applying two coats of cement base paint on wall over a coat of priming paint including preparation of new plastered surfaces,complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of average 1mm thick wall care putty on new plastered surfaces complete all as specified and directed.
M&L for preparation of old decorated plastered or un-plastered surface of wall and applying one coat of white wash complete all as specified and as directed
All as per item No.33 above but one coat of white wash on ceiling
M&L for Preparation of old plastered or unplastered surfaces of wall and applying one coat of cement base paint (snowcem) white or tinted complete all as specified and directed.
M&L for complete removal of existing treatment old plastered or unplastered surfaces including preparation surfaces of walls and applying two coats of distemper oil emulsion on wall over a coat of 1mm thick wall care putty complete all as specified and directed.
M&L for preparation of plastered surfaces and applying one coat of weather proof acrylic emulsion paint in different tint as in band/strips in narrow width and similer works complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection complete all as specified and directed.
S&F 15mm bore steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors (concealed) complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth etc. brick walls complete all as specified and directed.
S&F in repairs CP Bib taps fancy type 15 mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as pecified and directed.
S&F in repairs CP Bib taps fancy type long body 15 mm cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as pecified and directed.
S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including brackets, rubber bush, washers etc complete all as specified and directed.
S&F in repair 15 mm bore CP angle/Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed.
S&F in repairs 15mm concealed stop cock, chromium plated fancy type with long shank and cup complete all as specified and directed.
S&F in repairs Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)
S&F in repair PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed
S&F in repairs Vitreous china wash basin white flat back size 550 x 400mm incl waste pipe chain plug brackets complete all as specified and directed. .
S&F in Repairs vitreous China squatting pan, `Orissa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe and including concrete bedding) Complete all as specified as directed.
S&F in repairs White Vitreous china European wash down water closet pan of size as directed fixing with bolts including connecting to 100mm bore CI ‘P’ or ‘S’ trap with following accessories complete all as specified and directed. a. Flush pipe -01 b. Plastic seat cover coloured -01
S&F in repairs Vitreous china urinal partition white of size 310x700 mm complete
S&F in repairs ceramic large Urinal pot with white colour wall mounted oval type of size 37.5x60x32cm depth of make BM BELMONTE or equvilant complete
S&F 15mm bore, CP fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms) of 32mm bore suitable for wash hand basin complete all as specified and directed.
S&F in repairs 32 mm dia PVC waste pipe for wash basin /sinks 800mm long complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall/laid in trenches complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F in repairs PVC (SWR) pipe single socket in any length with rubber ring joints fitted to wall 75 mm as in repairs complete all as specified and directed
S&F PVC (SWR) bends of 75 mm radius to PVC SWR pipes including taking out existing bends as in repairs complete all as specified and directed
S&F in repair 500 ltrs capacity rotational moulded polyethylene water storage tank double layered, ISI engraved (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 10mm (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
Chamfer, splays or arris in facework of granite, marble etc complete all as specified and directed
S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mmbowl size 410mm x 330mm x160mm complete all as specified and directed
S&F in repair plate rack of 1mm thick stainless steel of size 900x600mm with three shelves complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed.
S & F Steel windows with side hung shutters including box type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S & F in repairs Mild steel work in framed work such as grills, gratings, guard bars etc, with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed.
S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F 3 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
M&L resecuring or easing & adjusting incl taking down shutters of size exc 2.00 sqm complete all as specified and directed
M&L for rolled sections as in framing for cladding, door chowkats, glazing and the like fixed with angle cleats and connecting plates, etc. complete all as specified and directed.
M&L 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixedcomplete all as specified and directed.
S&F Second class hard wood (SAL) chemically treated for ATT, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints including tarring back of chowkhat with a coat of crude oil complete all as specified and directed.
S & F 30 mm thick flush shutters, board solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 30 mm thick 2nd class hard wood (Hollock/Sal/Bijasal), glazed skeleton door shutters open rebated and prepare to receive glass, gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut including mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8, clause No 8.24 (a) complete all as specified and directed.
S&F solid PVC frame of size 50x47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube supplying & fixing in opening as specified in clause No. 8B.3 at Sl page No. 145 and shown in drawing on sl page No 160 of SSR 2010 respectively and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed
S&F in repair 18 mm thick Rajshree Celuka ply of grade 1 quality of one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters complete as per specification and as directed by Engineer-in-Charge.
S&F magnetic catcher as in cup boards and drawers complete all as specified and directed
S&F 75 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S&F 50mm dia, polished, hard wood knobs fixed with screws complete all as specified and directed
S&F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S&F 100 mm long Stailess steel Butt hinges complete all as specified and directed.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S & F in repair Galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned stacks, or galvanized wire staples complete all as specified and directed
S&F in repairs for stainless steel drapery rods, 25mm internal diameter including decoratine type brackets, side caps including fixing arrangement with drilling holes in walls, brackets etc complete all as specified and directed.
M & L for applying one coat of synthetic enamel paint including preparation of old wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer including preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth complete all as specified and directed.
S&F in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bars 5mm to 10mm dia as in stirrups, spacers complete all as specified and directed
M&L Pre-cast Reinforced cement concrete 1:2:4 Type B1 (20mm graded stone aggregate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces incl necessary formwork complete all as specified and directed
Dismantling of Stone slabs and tiles of any description or thickness in floors/roof slabs, aprons etc set in cement mortar complete all as specified and directed
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed
Dismantling and re fixing Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc complete all as specified and directed
S&F mild steel joist channel angle or tee sections fixed independently with out connecting plates etcof grade fe-410-W Gde E-250) quality A 310-0 complete all as specified and directed..
M&L cement concrete type B-1, 1:2:4 mix ( 20 mm graded stone aggregate) in padding, roof kerbs or mud stops, rounded or chamfered on edges and similar work incl necessary form work complete all as specified and directed.
M & L for water proofing treatment of roof slab all as followes: - (a) Preparation of roof surfaces by brushing & cleaning (b) Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm (c) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (d) Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen. (e) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition will be dusted over the bitumen @1.00 Kg/Sqm Note : WPC shall be measured and paid separately under respective item
M&L brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:6 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed.
M & L cutting holes into or through brick wall built in cement mortar exc one brick but n.exc two bricks and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F Anodised aluminium frame/shutters for doors, windows, ventilators and partitions with powder coated (Thickness of powder coating not less than 50 Micron) one or more rebates including joining cleat for fixing etc. complete all as specified and directed
S&F automatic floor mounted hydraulic door closer, heavy duty with pivot, aluminium body, ISI marked, complete all as specified & directed.
S&F automatic hydraulic door closer, heavy duty with pivot, aluminium body, ISI marked, complete all as specified & directed.
S&F 5.50 mm thick tinted sheet glass with necessary jointing cleats, glazing clips, rubber packing & anodised aluminium snap beading complete all as specified and directed. .
S&F 100 mm long Mortice latch with four levers (vertical type) , aluminium body and fixed complete all as specified & directed.
M&L 12mm thick veneered partcle board exterior grade faced with decorative veneer on both faces including fixing with rubber gasket complete all as specified and directed
S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre. size of grid 605 mm x 605mm complete all as specified and directed
S &F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified
S &F Exposed metal frame ceiling with calcium silicate board 6 mm thick if siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed
S&F PVC sheet wall panelling (wood grains) of thickness 5mm struck on interframe work on 50mm wide strip and 5mm thick PVC sheet the the strip should have a groove of 6mm width and 1mm depth in their centre for sinking the head of screw to the wall vertically the PVC strip shall be fixed to the wall using 65mm long MS screw not more than 200mm C/C throgh the groove in the strip by using PVC fastener complete all as specified and as directed
Dismantling wall and ceiling boards ( fibre, pulp, insulation etc or insulation boards/ slabs/ blankets any thickness including cover filletts complete all as specified and directed
M&L Sand cushion under floors/paver blocks, spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade With Grey Cement and pigment all as directed and specified.
S&F 75mm thick PCC 1:3:6 C-1 (using 20mm graded crushed stone aggregate) as in path/ hardstanding all as specified and directed
M&L for Chequered cement concrete tiles 300 x 300m x 25mm thick incl Screed bed 15mm thick in CM 1:6 set, jointed and pointed in near cement slurry in floors with grey cement and pigment complete all as specified and directed
S&F 12mm toughened glass door (made in required design) including 2 x Fancy handles 300mm long x 20mm dia and complete top and bottom spring mechanisms complete all as specified and as directed by Engineer in Cahrge
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Demolition and breaking up drain pipe (SGSW, AC, RCC or PVC) of 150mm bore incl demolition of PCC as in benching and hauching etc complete all as specified and directed
M&L of brick work in CM 1:4 using sub class 'B' bricks as in man holes, etc complete all as specified and directed
M&L PCC 1:2:4 type B-2 ( using 40 mm graded stone aggregate) as in surface chanels including necessary form work complete all as specified and directed
M&L PCC1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, benching etc incl necessary form work complete all as specified and directed
Extra for forming fair finished drain or channel 30cm inner girth using extra cement incl forms, moulds, etc. complete all as specified and directed
Add or deduct for each 25mm girth or part thereof over or under 30cm -ditto-
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in bed of drain pipe inch packing under and haunching against the sides of pipe after they are laid and tested for 150mm dia of pipe complete all as specified and directed
M&L of 150mm SGSW drain pipe laid in trenches and jointed in CM 1:1 complete all as specified and directed
M&L Treating the backfill in contact with foundation at the rate of 7.5 liters of ATT emulsion per square meter of vertical surface complete all as specified and directed
M&L Treating the top surface of filled earth at the rate of 5 litres of ATT emulsion per square meter of surface complete all as specified and directed
M&L Treating the soil under plinth protection at the rate of 5 litres of ATT emulsion per square meter of surface area complete all as specified and directed
M&L broken stone boulders hardcore of gauge n.exc. 63mm,depoisited ,spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface as in plinth protection complete all as specified and directed
M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection laying in alternate ways finished even and fair without using extra cement including filled joint with bitumin mastic complete all as specified and directed
Takign down shutters of any description exc. 1 Sqm and n. exc. 2 Sqm complete all as specified and directed.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multistranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, to be terminated in and excluding modular metal GI flush box and its cover plates for fixing modular type switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No.145 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the independent board but not below the switch board complete all as specified & directed.
All as per item No-145 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on the same board with other switches complete all as specified & directed.
All as per item No.145 here in before but point wiring for one modular socket out let 3/5 pin, 5/6 Amps controlled by one 1 way modular switch on independent board but below the switch board of light points in same vertical plane complete all as specified & directed.
All as per item No.145 here in before but point wiring for one six pin socket outlet 16 & 6 amps (independent) controlled by one modular switch 16 Amps using PVC FRLS cable of size 2.5 sqmm in lieu of 1.5 Sqmm complete all as specified & directed. NOTE-For item No 145 to 149 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface steel conduit of suitable size but not less than 20 mm bore fixed on surface with using PVC rawl plug, gully & saddles etc. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A here in after. (iii)The size of conduits shall be determined on permissible no of rns of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade). (iv) The rate of all type of conduit, fittings, rawl plugs etc deemed included in items.
Supply and fixing modular metal GI flush box 1/2 module as per site requirement suitable for 20mm dia conduit with and fixed in existing walls in CM 1:4 and making good the disturbed surfaces of walls as per existing complete all as specified and directed.
All as above item No.150 but modular type metal flush box of 3 module complete all as specified and directed.
All as above item No.150 but modular type metal flush box of 4 module complete all as specified and directed.
All as above item No.150 but modular type metal flush box of 6 module complete all as specified and directed.
All as above item No.150 but modular type metal flush box of 2 x 6 module complete all as specified and directed.
Supply and fix modular white cover plate with frame 1 module for mounting modular switches,sockets and regulators etc complete all as specified and directed.
All as per item No 155 but modular white cover plate with frame 2 module complete all as specified and directed.
All as per above item no 155 but modular white cover plate with frame 3 module complete all as specified and directed.
All as per above item no 155 but modular white cover plate with frame 4/5 module complete all as specified and directed.
All as per above item no 155 but modular white cover plate with frame 6 module complete all as specified and directed.
All as per above item no 155 but modular white cover plate with frame 2x 6 module complete all as specified and directed.
Supply and fix switch modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
Supply and fix bell push modular type, single pole, 6 Amps one module,one way, 230 volts complete all as specified and directed.
Supply and fix switch modular type, single pole, 16 Amps one module,one way 230 volts complete all as specified and directed.
Supply and fix socket outlet, 5/6 pin 6 Amps, modular type, 2 module 230 volts complete all as specified and directed.
Supply and fix socket outlet, 6 & 16 Amps, modular type, 2 module 230 volts complete all as specified and directed.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
Supply & fix rotory stepped type electronic fan regulator modular type,Single module 120 watt 230 Volts complete all as specified & directed.
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed.
Supply & fix commiosnig and testing of complete power cum starter unit compressing of ON/OFF switches, socket outlet 3 pin socket outlet with plug top modular type made out of white polycarbonate, fire retardant, UV stabilized power unit internally pre-wired with suitable size copper conductor cable with overload protective device (MCB) complete unit fixed in single polycarbonate housing with inlet & outlet cable port suitable for AC & geyser operated at single phase, 240 volts, 50 Hz AC supply of capacity 20 Amps load bearing capacity complete all as specified and directed.
Supply & fix single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed.
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed.
S&F 1x22 W, 220 V LED Batten surface/wall mounted with specially designed powder coated aluminium housing,high optically efficient polycarbonate diffuser,in built electronic driver duly wired up to terminal block,power consumption<20W,luminaire lumen >2000 lm,system efficiency of >120 lumens/W,LED make Nichia/Cree/Everlite/Eclison/Osram/lumiled,with LED binning as per ANSI Bin C78.377A,photo biological safety report as per IEC 624718& electrical insulation class 1 Ingress protection IP 20,clor rendering index CRI> 80 ,temp range 0 to 450 C ,driver efficiency >85% Power factor >0.9 THD <20% as per IEC 61000-3-2 ,color temp -6500K,Surge protection 2.5 KV,50000 burning hrs (min) as per L7O criteria,two stages isolated constant current operated driver with range 150-270 V AC and safety extra low voltage safe level< 60 V DC as per IEC standard with LM70 & LM 80 certification. complete all as specified and directed.
S&F for 2 ft x 2 ft recess mounted full panel LED luminaire with white powder coted housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired upto terminal block, power consumption< 35 W, luminaire lumen > 3500lm and system efficiency > 120lm/w, CRI> 80, LED Make :- Nichia/Cree/Osram/Lumined with LED binning as per ANSI Bin C78.377A, Photo biological safety report as per IEC624718 & electrical insulation class 1 , colour temp- 5700k, Ingress protection IP20, Driver efficiency > 85% , 50000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor > 0.95 THD <10%, surge protectionin CM-3KV, two stage isolated constant current operated driver with range 150-270V AC and safety extraa low voltage safe level < 60V DC as per IEC standard, with LM79 & LM80 certification. complete all as specified and directed.
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 15 Watt LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 complete all as specified and directed.
S&F LED security with aluminum pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-65 protection, power consumption < 30 W, luminaire lumen < 3000lm and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, CRI > 70, LED Make :- Nichia/Cree/Osram, ambient temprature range 0-450c, THD<10%, colour tempreature 5700K, surge protectionin cm 3.5KV, 50000 burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low volatge safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 25 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified and directed.
S & F LED light fitting 1x9 W/1X10 W bulkhead luminaires including LED light driver holderconnecting up with three core flexible copper conductor cable, power consumption < 10 W and system efficiency > 100lm /W, of suitable size complete all as specified & directed.
Supply and fixing in renewal round/ Square shape 12/15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
Supply and fixing 100 watt, 230 V AC outdoor type, 5700K LED security Flood light made out of pressure die cast aluminium housing with toughned glass , IP66 protection and impact resistance IK07 ,mounted on top of the pole with and incuding cap type bracket having lenght not less than 0.31 meter fixed with suitable fasteners having extended arm length not less than 1.5 meter and dia not more than 43 mm and angle between pole and extended arm should be 100 to 105 degrees including fabrication work for fixing Building security light . including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduit from celling rose to building security light fittings complete all as specified and directed.
Supply & fix NEW GENERATION POST TOP energy saving envirmental friendly long life 35 watt LED luminaire light fitting, IP 66 protection with reflector cover electronic driver, connector block etc with internally prewired fixed to brcket on gate with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor .
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length complete all as specified and directed. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length complete all as specified and directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with four runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 25mm dia with its accessories, concealed type, including two run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes :- Finished sub main wiring with four runs of 10.0 sqmm cable & two run of 10.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCCB/VTPN/TPN/SPN/Isolator/SP etc and making good the disturbed surfaces complete all as specified and directed.
Supply and fix MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed .
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed .
Supply and fix MCCB 4 pole 100 to 125 Amp, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB complete all as specified and directed.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed.
Supply & fix Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 63 Amps, IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning complete all as specified & directed.
Supply & fix Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 100 Amps, IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply & fix MCB SP, 40 to 63 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
Supply & fix MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit)
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 complete all as specified and directed.
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repaire/ servicing & painting with one coat of synthetic enable paint and re-hanging/ re-fixing in original position but including replacement of three coer flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as specified and directed
Supply and fix ceiling fan, 1200mm sweep, minimum 220 CFM, 230 V, BEE 5 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
S&F iron metal body heavy duty exhaust fan 300mm sweep, double ball bearing, copper wound, with louvers, 230 volts, 50 Hz, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
Supply laying and testing in renewal of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty), as per ISI marked, IS 7078 (E), 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core layed in tranch, fixed on wall/ ceiling/ floor with saddles with screwes with PVC plug or passing through in pipe or fixed on pole or any other indicated suitation complete all as specified and directed.
Supply laying and testing in renewal of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty), as per ISI marked, IS 7078 (E), 1100 volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core layed in tranch, fixed on wall/ ceiling/ floor with saddles with screwes with PVC plug or passing through in pipe or fixed on pole or any other indicated suitation complete all as specified and directed.
Supply & Laying,testing ,in renewal of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty), as per ISI marked, IS 7078 (E), 1100 volt grade, with stranded aluminium conductor of size 50 Sqmm 3.5 core layed in tranch, fixed on wall/ ceiling/ floor with saddles with screwes with PVC plug or passing through in pipe or fixed on pole or any other indicated suitation complete all as specified and directed.
Supply & Laying,testing ,in renewal of cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty), as per ISI marked, IS 7078 (E), 1100 volt grade, with stranded aluminium conductor of size 25 Sqmm 4 core layed in tranch, fixed on wall/ ceiling/ floor with saddles with screwes with PVC plug or passing through in pipe or fixed on pole or any other indicated suitation complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed.
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and directed.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as specified and directed.
Supply and fixing in renewal of GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed.
Supply and fixing GI Pipe 50mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed.
Supply and fixing GI Pipe 80mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed.
M&L for MCCB 4 pole, 160 Amp, 415 Volts, 50 Hz, DPX³ 160, Icu- 36 KA, with microprocessor, Ics-100% of Icu, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting (min 70% to 100%) to be fixed existing LT pannel as outgoing switchgear complete all as specified & directed.
Supplying, fixing, commissioning and testing, self supported, cubical, floor mounted, indoor LT panel, CPRI approved and confirming to IS 61439-, dust and vermin proof factory fabricated, made out of not less than 2 mm thick CRCA sheet, powder coated, suitable for operation on 3 phase, 4 wire system, 50 Hz, 415 volts, including internal wiring with 1100 volts grade single core, PVC (FRLS) insulated, multistranded copper conductor cables of suitable current carrying capacity complete and comprising of the following accessories. (a) INCOMMER :- (i)MCCB 4 pole, 250 Amp, 415 Volts, 50 Hz, DPX³ 250, Icu- 36 KA, confirming to IEC-60947-1/2 & insulation glass should be according to IEC-60664-1, with microprocessor, Ics-100% of Icu, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting (min 70% to 100%) Make- L&T - 02 No. (01 for Main + 01 for Genretor set) (ii) Aluminum bus bar of capacity 400 Amp, 3 phase 4 wire system duly colour coded tape/ paint duly mounted on insulators - 02 Set. (iii) Digital type volt meter of size 96 x 96 mm make - AE - 02 No. (iv) LED type indicating lamp for 3 phase (RYB) including control wiring - 02 Set. (v) Change over on load type 4 pole 250 Amps suitable for interior with rotary type handle front operated. - 01 Nos
(b) OUTGOING :- (i) Aluminum bus bar of suitable capacity for outgoing MCCB's, 3 phase 4 wire system for each outgoing feeder.- 08 Nos (ii) MCCB 4 pole, 160 Amp, 415 Volts, 50 Hz, DPX³ 160, Icu- 16 KA, confirming to IEC-60947-1/2 & insulation glass should be according to IEC-60664-1 with microprocessor, Ics-100% of Icu, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting (min 70% to 100%) Make- L&T - 02 Nos (iii) MCCB 4 pole, 100 Amp, 415 Volts, 50 Hz, DPX³ 160, Icu- 16 KA, confirming to IEC-60947-1/2 & insulation glass should be according to IEC-60664-1 with microprocessor, Ics-100% of Icu, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting (min 70% to 100%) Make- L&T - 02 Nos (iv) MCCB 4 pole, 63 Amp, 415 Volts, 50 Hz, DPX³ 160, Icu- 16 KA, confirming to IEC-60947-1/2 & insulation glass should be according to IEC-60664-1 with microprocessor, Ics-100% of Icu, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting (min 70% to 100%) Make- L&T - 02 Nos (v) MCB SPN 40 Amp, 240 volts, 50 Hz, 10 KA, ISI marked as per IS/IEC 60898-1 2002- 02 Nos (vi) MCB Isolator TPN 40 Amp 240 volts, 10 KA, 50 Hz, ISI marked as per IEC 60947-3 - 02 Nos (vii) Digital type volt meter of size 96 x 96 mm for each outgoing feeder make - AE (viii) Digital type Amp meter 0-500 Amps with CT Coil ratio 100/5 of size 96 x 96 mm for each outgoing feeder make - AE - 08 Nos (ix) Internal copper wire/ strip connection completely from incoming bus bar to out going switch gear with suitable size copper cable complete- 01 Job
Allied Agencies
deva engineers
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .