PLANNING
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Tenderer shall have a valid Electrical Contractor's License issued in the name of the firm by any State Government and shall furnish/attach all the particulars of the Electrical license along with their offer.
(a)The Tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b)(i) In case of tender for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works costing not less than the amount equal to 30% of advertised value of each component of tender, or (iii)Two similar works costing not less than the amount equal to 40% of advertised value of each component of tender, or (iv)One similar work costing not less than the amount equal to 60% of advertised value of each component of tender. Note:- Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated /registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of similar nature of work:- For this tender the following work only will be considered similar work for judging the technical eligibility criteria. ""Design, Supply, Installation, Testing & Commissioning of HT/LT network like HT/LT panel, Overhead distribution network, earthing, laying of HT/LT cable etc. and associated electrical works. "
23 conditions · 3 needing a document upload
If firm ( Partnership Firm, Registered Society & Registered Trust) is required to submit Power of attorney it should be submitted as per given proforma enclosed in tender document.
If firm (Company registered under Companies Act 2013) is required to submit a copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company it should be submitted as per given proforma enclosed in tender document.
If firm LLP (Limited Liability Partnership) is required to submit a copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP, it should be submitted as per given proforma enclosed in tender document.
1.0 The tenderer should indicate clearly replies against item included in this check list. 2.0 Furnished the details of credential Alongwith attested copies of supporting document. 3.0 Quoted the accessories and essential spares. 4.0 Furnished your ITCC (income Tax clearance Certificates. 5.0 Quoted period of completion correctly. 6.0 Kept your offer valid for 60 days. 7.0 Visited the site and have studied the methodology To be adopted for completion of the work. 8.0 Submitted the integration scheme. 9.0 Submitted the BAR CHART /PERT CHART. 10.0 Submitted scheme of completion of work. 11.0 Submitted details of staff working under tenderer. 12. Submit the bid security certificate in appropriate form.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical Work in Connection with Provision of Air Conditioner in Station Master's Office (VDU Rooms) at 157 Stations Over Lucknow Division.
1222-SrDEE-NR-LKO~NR
1222-SrDEE-NR-LKO
Open
Works - General
9 Months
Lucknow, Uttar Pradesh
₹0
₹3.1 L
18 Sept 2026
18 Sept 2026
28 Sept 2026
67 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,54,99,943.16 | ||
| — | 3000.00 | — | — | ||
| Supply and Recessing/Fixing of PVC Conduit Pipe Conforming to IS. 9537 Part-III.1987 (Latest version) with Accessories Junction box, Bends etc. Including Making Chase, Plastering/Clamping etc. As per Technical Scope of Work. Size-25 mm dia (Medium) | — | — | — | 1,18,350 | |
| — | 4000.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-1.0 sq mm | — | — | — | 43,800 | |
| — | 10000.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-4.0 sq mm | — | — | — | 3,22,500 | |
| — | 2000.00 | — | — | ||
| Supply of Following sizes FRLS PVC Insulated Multi Stranded Copper Conductor Single Core Cable conforming to IS 694 (Latest Version) , and Drawing in Laid (recessed /surface) M.S / PVC Conduit Pipe for Wiring of Point Wiring / Circuit Wiring / Sub Main / Main as required Including Connections, Testing and Commissioning. As per Technical Scope of Work Size-6.0 sq mm | — | — | — | 1,34,260 | |
| — | 200.00 | — | — | ||
| Supply of Material & Commissioning of PVC Casing Caping of Size 25mm x12mm (WXH) with accessories for Surface Wiring as per the Technical Scope of Work. | — | — | — | 6,110 | |
| — | 100.00 | — | — | ||
| Supply and Laying of 25 mm FRPP Corrugated Flexible Conduit Pipe as per standard specification.As per Technical Scope of Work | — | — | — | 3,005 | |
| — | 160.00 | — | — | ||
| Supplying and Fixing of CRCA sheet steel, 8 Way SPN, Double Door MCB Distribution Box, 240 V, IP54, on surface/recess, complete with tinned Copper Bus bar, Neutral Bus bar, Earth bar, Din bar, Interconnections, Powder Coated Including Earthing etc. a) DP MCB 25-32 A,10 KA "B/C" curve (incoming)-1 No, b) 25A DP RCCB = 01 No. having a Sensitivity Current 30 ma c) 6-32A ,10 kA MCB SP "B/C" curve = 04 Nos.(Outgoing). Make of MCB, RCCB & DBs: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per Technical Scope of Work | — | — | — | 10,38,132.8 | |
| — | 50.00 | — | — | ||
| Supply, Erection, Fixing, Testing and Commissioning of Double Door 4 Way ,TPN, Distribution Box, IP 54, along with 1X 125 Amp 3P MCCB 35 kA, 12X 6 -32 Amp 10 kA MCB SP "B/C" curve as per requirement Complete in all respect. Make of MCB/MCCB & DB: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager.As per Technical Scope of Work. | — | — | — | 8,53,832.5 | |
| — | 250.00 | — | — | ||
| Earthing with 40 mm Dia GI Pipe Class 'B' , 3 Meter Long Earth Electrode a s per IS:3043 (latest version) t o Achieve Earth Resistance Less than 5 Ohms Including Construction of Masonry Enclosures with Hinged Cover plate of Cast Iron with Locking Arrangement (Approx. size 400 mmx 400 mm) on Top, Provision of Earth Plate,Connections from Earth Electrode to Switch gear/pole as per drawing & as per Technical Scope of Work | — | — | — | 5,15,657.5 | |
| — | 2000.00 | — | — | ||
| Supply, Laying, Connection & Commissioning of 8 SWG GI Wire & Drawing in Laid/on Surface MS/PVC Conduit Pipe, Confirming to relevant IS Buried in Ground/Recessing in Floor from Earth Electrode to Earth Terminal of Equipment's. Including Supply of Material. As per Technical Scope of Work. | — | — | — | 28,040 | |
| — | 1500.00 | — | — | ||
| Supply, Laying, Connection & Commissioning of G.I. strip 12.5x3 mm (Galvanized) confirming to Relavent IS as per IS:3043 (Latest version), Fixing on Surface or as per site condition, Clamping or Fixing with suitable Arrangement as per Site requirement.As per Technical Scope of Work. | — | — | — | 57,690 | |
| — | 400.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of Cable End Termination Kit and Lugs of Cable for Energization,Suitable for Cable Size 25-150 sqmm cable 2 Core. As per Technical Scope of work. | — | — | — | 76,000 | |
| — | 50.00 | — | — | ||
| Supply, Installation , Testing and Commissioning of LT Heat Shrinkable Straight Through Jointing Kit and Jointing of Cable. As per Technical Scope of work.Suitable for Cable Size 25- 150 Sq.mm,2 core ( Only LT cable supplied by the Railway) , Make:-Raychem, 3M, Densons, Cabseal or other reputated make with prior Approval. | — | — | — | 92,901 | |
| — | 410.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of End Termination Kit of 3-½ C / 4.0 C X35 to 240 sq. mm. LT XLPE Cable as per Specification. (One set means lugs in R-Y-B-N).Suitable for Cable Size 3-½ C / 4.0 C X35 to 240 sq. mm. As per Technical Scope of work | — | — | — | 1,67,903.2 | |
| — | 40.00 | — | — | ||
| Supply, Installation , Testing and Commissioning of Heat Shrinkable Straight Through Jointing Kit and Jointing of Cable. As per Technical Scope of work..Suitable for Cable Size 35-185 Sq.mm,4 core , ( Only LT cable supplied by the Railway), Make:-Raychem, 3M, Densons, Cabseal or other reputated make with Prior Approval. | — | — | — | 1,75,274.4 | |
| — | 5.00 | — | — | ||
| Design, Manufacture, Supply, Erection, Testing & Commissioning of Front Operated Double door type Weather Proof Feeder Pillar Suitable for IP-65 Degree of Protection with Digital measuring Instrument & Copper Bus-bar Arrangement, Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest. Comprising with the Following MCCB's fixed in it: : i) Incoming MCCB 4P 250 Amp, 35 kA with Adjustable Thermal Magnetic Release =01 No. ii) Outgoing MCCB 4 Pole 125A, 35 kA - 02 Nos. iii) Outgoing MCCB 4P 63 A, 35 kA - 06 Nos. iv) Outgoing MCCB 4P 32A, 35 kA - 04 Nos. The Feeder Pillar shall be complete with 250A Copper Bus Bars for Phases and 125A for Neutral. As per Drawing Approved by Railways and Technical Scope of Work.Make of MCCB's :- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to IS/IEC 60947-2 or latest. The LT Panel manufacturer should be CPRI-Approved . | — | — | — | 9,07,424.15 | |
| — | 15.00 | — | — | ||
| Design, Manufacture, Supply, Erection, Testing & Commissioning of Front Operated Double door type Weather Proof Feeder Pillar Suitable for IP-65 Degree of Protection with Digital measuring Instrument & Copper Bus-bar Arrangement, Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest. Comprising with the Following MCCB's fixed in it; i) Incoming MCCB 4P 125A, 35 kA with Adjustable Thermal Mangnetic Release -1 Nos. ii) Out going MCCB 4P 63 A , 35 kA -2 Nos iii) Out going MCCB 32A 4P, 35 kA -6 Nos. The Feeder Pillar shall be complete with Copper Bus bars 150 Amps. for Phases and 75 Amps for Neutral.As per Drawing Approved by Railways and Technical Scope of Work.Make of MCCBs:- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to IS/IEC 60947-2 or latest. The LT Panel Manufacturer should be CPRI- Approved . | — | — | — | 18,82,347.3 | |
| — | 20.00 | — | — | ||
| Design, Manufacture, Supply, Erection, Testing & Commissioning of Front Operated Double door type Weather Proof Feeder Pillar Suitable for IP-65 Degree of Protection with Digital measuring Instrument & Aluminium Bus-bar Arrangement, Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest. Comprising with the Following MCCB's/MCBs fixed in it;. i) Incoming 4P MCCB 250 Amps 36 kA with Adjustable Thermal & Fixed Magnetic Release =01 No. ii) Outgoing 4P MCCB 63 Amps 36 kA with Adjustable Thermal & Fixed Magnetic Release =05 Nos. iii) Outgoing DP MCB 6-32 Amps 10 kA MCB SP "B/C" curve = 05 Nos. As per Drawing Approved by Railways and Technical Scope of Work. Make of MCCBs/MCBs:- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to relevant IS/IEC. The LT Panel Manufacturer should be CPRI- Approved . | — | — | — | 23,49,873.6 | |
| — | 19.00 | — | — | ||
| Design, Manufacture, Supply, Erection, Testing & Commissioning of Front Operated Double door type Weather Proof Feeder Pillar Suitable for IP-65 Degree of Protection with Digital measuring Instrument & Aluminium Bus-bar Arrangement, Conforming to IS/IEC 61439 -1 & 2,Edittion 3, 2020 with Latest Amendments or latest. Comprising with the Following MCCB's/RCCBs/MCBs fixed in it; i) Incoming 63A Microprocessor MCCB 4P 36 kA= 01 No. ii) Outgoing 40A 4P RCCB = 01 No. iii) Outgoing 6-32A MCB DP10 kA MCB SP "B/C" curve = 06 Nos. As per Drawing Approved by Railways and Technical Scope of Work.Make of MCCBs/RCCBs/MCBs:- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to relevant IS/IEC. The LT Panel Manufacturer should be CPRI- Approved . | — | — | — | 9,35,519.91 | |
| — | 7000.00 | — | — | ||
| Laying of 1.1 KV grade LT XLPE Insulated Armoured, Aluminium Conductor Cable of Different Sizes as per Cable route Plan Approved by Railways and Meggering of Cable before and after its Laying. As per Technical Scope of work( Cable will be Supplied by the any Railway store of Lucknow Division) | — | — | — | 72,800 | |
| — | 4000.00 | — | — | ||
| Excavating and Refilling of Trench in Normal Soil to the Level of Ground with Rammed Earth as per Site Incharge and as per Cable Route Plan. so as not to form a Drain. Size of Trench should be 0.3 Mtrs. Wide & 1 Mtr. Deep as per Cable Plan and Instructions of SSE/incharge. It shall confirm to the Safe Distance as per Cable Plan. It also Includes Clearance of Roots of Trees & Bushes. As per Technical Scope of Work. | — | — | — | 3,65,520 | |
| — | 20000.00 | — | — | ||
| Supply and Laying of 2nd Class New Bricks in the Trench and Laying as per Cable Plan and Instructions of SSE/incharge. As per Technical Scope of Work. | — | — | — | 1,93,400 | |
| — | 2500.00 | — | — | ||
| Clamping of Cable with Wall / Trusses / Cable Tray / Angle with help of Nut, Bolt & Washer. The Clamp made out of GI strip Size not Less than 32X5 mm).As per Technical Scope of Work. | — | — | — | 82,100 | |
| — | 1500.00 | — | — | ||
| Platform Surface/Concrete cutting for Excavation of Cable Trench 300 mm Wide x 300 Deep, Re-fitting of Soil and Re-Plastering of Excavated Trench with Cement on the PF's to bring Original Shape.As per Technical Scope of Work. | — | — | — | 8,56,380 | |
| — | 1000.00 | — | — | ||
| Horizontal boring size up to 125 mm Dia & minimum 1.0 Mtr Depth from Ground Level by Horizontal Deep Drilling Machine or Suitable Machine Including Supply and Commissioning of DWC HDPE Pipe as per IS-16205 or latest. Size Outer Dia 120 mm and Inner Dia 103 mm. DWC HDPE Pipe to be Provided at the Starting Bore and at End of the Bore upto Maximum Feasibility for Horizontal Bore Complete in all respect as per Site requirement and as per Technical Scope of Work. | — | — | — | 5,21,170 | |
| — | 1000.00 | — | — | ||
| All Work of Manual Horizontal Boring and Trenchless Cabling along with Supply, Transportation and Insertion of DWC HDPE Pipe as per IS-16205 ( Latest version, ( ISI marked ) and the Laying of Cable in the boring under the Track /Road etc. as per Instruction of Site Incharge by using Pipe of Size 120 mm Nominal Dia in which required number of Cables to be crossed. DWC HDPE Pipe will be Supplied by Contractor. The Depth of Horizontal Boring should be Minimum 1.0 m from Rail Flange/Road Level.As per Technical Scope of Work. ( Cable will be supplied by the any Railway store of Lucknow Division) | — | — | — | 12,37,390 | |
| — | 500.00 | — | — | ||
| Fabrication, Supply and Fixing of MS stand/ Cabinets or any other MS Structure for Precooling Points, Battery Charger, Electrical Panels, covering of any Electrical Structure or Cable Support Structure. The work Includes Structural Steel work, cutting, Welding Riveting, Nut Bolts or Welded in Built up sections, Trusses and framed work and Applying Primary coat of Steel primer and one coat of Painting of Approved Shade, as per site requirement/ approved drawing. The Work also Includes Foundation work and Grouting of MS structure/stand as per Site requirement and direction of Site Incharge. As per Technical Scope of Work. | — | — | — | 57,435 | |
| — | 1000.00 | — | — | ||
| Dismantling/Removing and Rerouting of Existing Aluminium Conductor Armored Cables from 4-300 sq mm X 4core, with Clamping and by Removing M. S. Cable Clamp.As per Technical scope of work. | — | — | — | 24,190 | |
| — | 70.00 | — | — | ||
| Manufacturing and Supply, Erection and Commissioning of Bus bar type Junction box, 4 pole Alluminium Bus bar 4 Strip, Capacity 200 Amp each Bus bar, Enclosure made of 16 SWG CRCA with Powder Coating, Bus bar not less than 250 mm Length or Suitable for 4 Way Complete as per IS and site requirement Including Civil Foundation work required to Install Junction box. As per Technical Scope of Work. | — | — | — | 3,39,601.5 | |
| — | 55.00 | — | — | ||
| Supply, Assembly, Fixing and Commissioning of Pole mounted/ Wall Mounted Junction Box of Size 300 X 300 X170 IP-65 Including Standard Connection Plate TPN-100 Amps in DMC with Colour caps. Polycarbonate Junction Box Similar to M/s HENSEL Model No. MI- 0201.of Pole/Wall Mounted Junction Box as per site requirement and Direction of Site Incharge. As per Technical Scope of Work. | — | — | — | 1,38,603.3 | |
| — | 200.00 | — | — | ||
| Supply, Erection, Connection , Testing and Commissioning of Powder Coated Sheet metal deep drawn distribution board fitted with 20 Amp plug socket 2P + E, 240V AC and 16-20 Amp MCB (1 P + N) complete in all respect as per site requirement .As per Technical Scope of Work. | — | — | — | 3,66,706 | |
| — | 200.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Electronic Voltage stabilizer suitable for one Air Conditioner unit upto 2 Ton Capacity . The Electronic Voltage Stabilizer having Digital Display , Wall Mounted , Capacity 15Amp , Input Voltage range :130-300Volt A C ,50 Hz ,Low/High Voltage Cutoff 120/300Volt , Time Delay 4 -6 sec Initial Delay. Make o f Voltage Stabilizer : M/s V- Gaurd Model No VWR 500, M/s Microtek Model No EM5150+. , M/s Livgaurd Model No LS2G 500/LG 500, Voltas Model No VA5130, Blue Star VS513DTA-GT or Equivalent Model of above Mentioned make with Prior Approval. As per Technical Scope of Work. | — | — | — | 10,29,324 | |
| — | 200.00 | — | — | ||
| Installation, Testing and Commissioning of Split AC 1.5 Ton/2 Ton Capacity Indoor and Outdoor Unit and Providing Drainage Pipe upto nearest Drainage point. The work Includes Top up of Prescribed Refrigerant required during Installation. The work also Includes Supply and Commissioning o f Bracket with Fastener for Outdoor unit Complete with all related Accessories. As per Technical Scope of Work. | — | — | — | 5,06,702 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender_document_1222.pdf
ATTACHMENT
I_CT_GCC-
ATTACHMENT
ACStoGCC1-10.pdf
ATTACHMENT
GCCACS113_compressed.pdf correction slips
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
GCCACS113_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .