Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC lowest | |
| 2 | L2₹39.9 L+₹22,234 (0.56%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹41.4 L+₹1.8 L (4.41%)Rejected-Finance A 2 206 SAI DWARKAMAI NIBM ROAD KONDHWA PUNE 411 048 | PUNE | MAHARASHTRA | 411048 | L3 | Rejected-Finance RATE HIGH |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Pune
NO 1 GEN BHGAT MARG PUNE 40
8601 COMPREHENSIVE REPAIR UNDER AGE BR II OF GE SOUTH PUNE
2024_MES_672190_1
8601 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
180 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹96,000
Yes
18 Nov 2024
5 Sept 2024
5 Oct 2024
5 Sept 2024
3 Oct 2024
20 Sept 2024
Amount
Refixing of old serviceable steel tubing and connection in new or old position (Wall, ceiling floor etc.) with and including necessary fittings & fixtures etc including taking up or down of old steel water tubing and connections including cleaning for refixing or remove from site , complete all as specified and directed for following size of pipes :- (a). 15mm bore
(b) 20 mm bore
Supplying, fixing, jointing and testing galvanised steel tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floor including taking up or down of old steel water tubing and connections including cleaning for refixing or remove from site, complete all as specified and directed for following size of pipes :- (a). 15mm bore
(b) 20 mm bore
(c) 25 mm bore
Attending of day to day complaints of plumbing work by deploying one plumber for 8 hrs in working day to attend any type of complaints such as repairs of taps / cocks, showers, towel rail / rings, flush tank, pipe lines, fixing of new taps / cocks, showers, towel rail / rings, flush tank, water tanks, pipe lines and all plumbing works complaints received and ordered by Engineer-in-charge. The plumber should have necessary equipment & tools including ladder etc as required for 01 plumber for 08 hrs working complete all as directed by Engr-in-Charge. Note :- (i). Each Job shall contain 8 hrs working of 01 plumber per day to attend various complaints of plumbing received by the office / Armaan each day. All spares, fitting and fixture (if any) required for smooth functioning of above mentioned fittings will be provided by Engr-in-Charge free for fixing. (ii). All minor complaints will be attended within 24 hrs and major complaints within 7 days (Major / Minor complaint shall be decided by Engr-in-Charge and in case of dispute (if any), the decision of GE shall be final and binding.
Attending of day to day complaints of carpenter work by deploying 01 carpenter to attend any type of complaints such as repairs & easing to doors, windows, ventilators, cupboards, shelve etc and fixing of doors, windows, ventilators, cupboards, shelve etc, fixing of fittings of doors, windows, ventilators, cupboards, shelve etc and all carpenter works / complaints received and ordered by Engineer-in-charge. The carpenter should have necessary equipment & tools including ladder etc as required for 01 carpenter for 08 hrs working complete all as directed by Engr-in-Charge . Note :- (i). Each Job shall contain 8 hrs working of 01 plumber per day to attend various complaints of plumbing received by the office / Armaan each day. (ii) All hardware (if any) required for smooth functioning of above mentioned door, windows & ventilators will be provided by Engr-in-Charge free for fixing
S & F in repairs gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified and directed for the following bore dia of pipe:- (a) 15mm bore.
(b) 20 mm bore
(c) 25 mm bore
S&F in repairs 15mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 142 gms), complete all as specified and directed.
S&F in repairs 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms), complete all as specified and directed.
S&F in repairs 25/32mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 455 gms), complete all as specified and directed.
M & L for cutting grooves on stone slabs such as in steps and other similar situations complete all as specified and directed by Engr-in-charge
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed
M&L for cutting chases, pinning in, concrete block / brick / stone walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing / PVC conduit etc and making good, cutting n. exc. 10 cm girth, complete all as specified and directed.
M&L for cleaning and removing all dirt and scale etc from tank and from the mouths of circulating pipes for the tanks by using bleaching powder including minor repairs i.e S&F in replacement of old unserviceable float valve, vent pipe, gate valve (If any required at site) suitable for following capacity of tanks including written of date of cleaning with white or black (As applicable) synthetic enamel paint complete all as specified and directed:- (a) Not exc. 500 Ltrs
(b) Exc. 500 Litres but n. exc. 1000 Litres.
S&F in replacement rotational moulded polyethylene water storage tank 500 Litres capacity, double layered, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old unserviceable water tanks and removing to store, including making all connections to inlet and outlet pipe lines, including providing of new tank nipples of suitable size, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement rotational moulded polyethylene water storage tank 1000 Litres capacity, double layered, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old unserviceable water tanks and removing to store, including making all connections to inlet and outlet pipe lines including providing of new tank nipples of suitable size, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement rotational moulded polyethylene water storage tank 2000 Litres capacity, double layered, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old unserviceable water tanks and removing to store, including making all connections to inlet and outlet pipe lines including providing of new tank nipples of suitable size, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall / ceilings, including taking down of old unserviceable pipe complete all as specified and directed. Note for item nos 16 & 17:- Rate quoted shall be deemed to be inclusive of the cost of necessary scaffolding & security measures as the work is to be carried out on elevated height upto 12.0 m high building.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/ ceilings including taking down of old unserviceable pipe, complete all as specified and directed.
S&F in repairs PVC (SWR) bends / Tee with acess door any radius 110 mm bore , complete all as specified and directed.
S&F in repairs PVC (SWR) bends / Tee with acess door any radius 75 mm bore , complete all as specified and directed.
M&L for Gypsum ceiling board for ceiling pre-painted, perforated finish, 595x595x9 to 9.5mm thick in size, of approved brand / make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. Tee 32 x 24 mm for main, 25x24mm for cross Tee and 20 x 20mm angle fixed on walls, powder coated finish on exposed faces of Tee and angle including hung from ceiling by using 2 mm dia G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans / light etc including taking down of old unserviceable false ceiling of any type complete at as specified and directed
M&L for PVC coloured false ceiling sheets of 595x595x9 to 9.5mm thick in size, of approved brand / make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. Tee 32 x 24 mm for main, 25x24mm for cross Tee and 20 x 20mm angle fixed on walls, powder coated finish on exposed faces of Tee and angle including hung from ceiling by using 2 mm dia G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans / light etc including taking down of old unserviceable false ceiling of any type complete at as specified and directed
M & L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw (as per manufacturer’s instructions) with and including Gl frame work suitable for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including two coats of oil bound distemper over primer on ceiling including dismantling of existing false ceiling with grid complete all as specified and directed
M & L for decorative POP cornices / moulding of pattern as per approved by Engr-in-charge of cross section area exc. 13 Sqcm and n. exc. 25 Sqcm including applying two coats of oil bound distemper over a coat of primer on POP cornices / moulding surfaces complete all as specified and directed
Hacking out old broken glass of any thickness / Size or quality from aluminium door / window frame fixed with rubber packing and aluminium beading tinted glass and S&F 5.5mm thick plain sheet glass, ordinary quality area exceeding 0.50 Sqm each pane complete all as specified and as directed
Hacking out old broken glass of any thickness / size or quality from wooden / metal frame fixed with putty / beading and S&F 3mm thick sheet glass, plain or frosted ordinary quality not exc. 0.5 Sqm in each pane complete all as specified and as directed
S&F 75 mm PVC (SWR) multi floor trap with grating including jointing with solvent cement , complete all as specified and directed.
Dismantling of single layer Mangalore pattern tiles or similar tiles in roofing incluidng ridge etc complete all as specified and directed
M&L for roof tiles, Mangalore pattern Gde 'AA' interlocking at side joints laid dry complete all as specified and directed.
Fixing only for roof tiles Mangalore pattern interlocking at side joints laid dry (except tiles) complete all as specified and directed.
M&L for ridge or hip tiles to suit Mangalore pattern roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed
Fixing only ridge or hip tiles to suit Mangalore pattern roofing tiles complete all as specified and directed.
Dismantling of battens for tiles shingles etc of any size including tiling fillets exc. 15 cm spacing etc complete all as specified
M&L for 2nd class hardwood clean sawn battens exceeding 5 and n. exc. 15 Sqcm in cross section, spaced at 30cm centres complete all as specified and directed
Fixing only 2nd class hardwood clean sawn battens at 30cm centres exc. 5 and n. exc. 15 Sqcm ( Except batten) complete all as specified and directed
Dismantling timber scantlings, 40 Sqcm over in section in any position, fixed with nails unframed work and S&F of new 2nd class hardwood scantlings clean sawn as in ceiling work, complete all as specified and directed
S&F in repairs 2nd class hard wood, 20mm thick boarding fixed with nails in any situation planed one side with butt joints complete all as specified and directed
Dismantling timber scantling unframed in post, rafters, purlins etc under 40 Sqcm in section and M&L for plain fillets of IInd class hard wood exc. 13 but n. exc. 25 Sqcm in section, square rectangular or triangular in section secured with screws complete all as specified and directed
M&L for preparing of surfaces of slate battens, any size and spacing prepared and treated all over (measured overall on one side only, spaces not deducted) with two coats creosote complete all as specified and directed
M&L for cleaning of roof area, not exceeding 300 Sqm each and chajja’s of bldgs front, rear and side complete including clearing mouth of rain water pipes and spouts in chajja’s etc complete including removals of roots of vegetative growth, algae, small plants and applying hydrochloric acid on the left over roof portion etc and making good the existing surface with cement mortar plaster in CM 1:3 mixed with liquid WPC as per manufacturer’s instructions, minimum area of cement plaster per block - 05 Sqm, complete all as directed by Engr-in-Charge
M&L for cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment / surface and carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50, complete all as specified and directed. Make: PIDILITE or equivalent make as approved by GE.
M&L for glazed coloured designed ceramic tiles of size 300x200x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles including 10 mm thick rendering as in backing coat in CM 1:4 including triangular filleting in CM 1:4 on top edges including dismantling of existing unserviceable tiles & backing coat of any description and removal of debries & dismantled materials outside the MD land complete all as specified and directed.
M&L for non skid ceramic colored tiles 7 to 8mm thick (square / rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm as in flooring etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match laid over and including 15mm thick screed bedding layer in CM 1:6, including dismantling of existing unserviceable floor hearth or tiles & screed bedding layer of any description and removal of debries & dismantled materials outside the MD land complete all as specified and directed
M&L for non skid ceramic colored tiles 7 to 8mm thick (square / rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm as in flooring etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match laid over and including 15mm thick screed bedding layer in CM 1:6, including dismantling of existing unserviceable floor hearth or tiles & screed bedding layer of any description and removal of debries & dismantled materials outside the MD land complete all as specified and directed
M&L for non skid ceramic colored tiles 7 to 8mm thick (square / rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm as in skirting etc. set and jointed in neat cement slurry & pointed in white or coloured cement to match laid over and including 10mm thick rendering / backing coat in CM 1:4, including triangular filleting in CM 1:4 on top edges including dismantling of existing unserviceable tiles & backing coat of any description and removal of debries & dismantled materials outside the MD land complete all as specified and directed
M&L for machine cut cuddapa stone slabs, one side polished, 20 to 25mm thick set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 20mm screed bed in cement mortar 1:6 including dismantling of existing unserviceable stone slab & screed bedding layer of any description and removal of debries & dismantled materials (except stone slab) outside the MD land complete all as specified and directed
M&L for (light shade) Vitrified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 including dismantling of existing unserviceable tiles / floor hearths & screed bedding layer of any description and removal of debries & dismantled materials outside the MD land complete all as specified and directed.
M&L for (light shade) Vitrified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering / backing coat in CM 1:4, including triangular filleting in CM 1:4 on top edges including dismantling of existing unserviceable wall hearth or tiles & backing coat of any description and removal of debries & dismantled materials outside the MD land complete all as specified and directed
M&L for glazed coloured designed ceramic tiles of size 600x300x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles including 10 mm thick rendering as in backing coat in CM 1:4 including triangular filleting in CM 1:4 on top edges including taking down of existing tles & backing coat of any description and removal of debries & demolished materials outside the MD land complete all as specified and directed.
M&L for 20 mm thick Granite slab (of any type/colour) work (table rubbed and polished) in steps, pillars; window cills / jamb, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite as counters of any radious etc laid over and including 15mm thick screed bed in CM 1:6 including dismantling of existing floor of any description including removal of debries & demolished materials (except stone slabs / tiles) outside the MD land complete all as specified and directed.
Supply and fix in repairs sink made of stainless steel 1mm thick for kitchen without drainage board including with plugs, washers and CP Brass waste coupling, waste pipe and fitting including bedding in cement mortar to dwarf wall or including fixing & providing cantilever brackets or fixed as in counter type in granite / cuddappa platform and connecting union to pipe, overall size of sink 495mm X 420mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed
S&F in repairs sink with drainage board made of stainless steel 1 mm thick for kitchen with and including plugs, CP Brass waste coupling washers and waste pipe and fitting including bedding in cement mortar to dwarf wall or including fixing & providing cantilever brackets and connecting union to pipe, overall size of sink 1020 mm X 510 mm, bowl size 460 mm X 360 mm X 160 mm complete all as specified and as directed
S&F in repairs vitreous china wash down water closet pan, 'Pedestal' coloured, including fixing bolts etc including PVC seat cover white with flat bottom including MS, CP or aluminium anodised hinge devices etc. complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltrs capacity approved make including all internal fitting, pair of bracket, including inlet / outlet PVC pipe connections etc complete all as specifed and directed by Engr-in-Charge.
S & F in repairs wash hand basins, vitreous china of size 550mm X 400mm including providing CI brackets including S&F of 32 mm bore waste fittings brass chromium plated with long screwed shanks and fly nuts, screwed for iron pipe and 32mm dia PVC waste pipe with and including 15 mm bore CP fancy type Pillar cock with long shank etc. complete all as specified and as directed
S&F in repairs Bib taps, 15mm bore, CP fancy type with wall flange conforming to CAT No. CON- 037 Jaquar / 9206 (CASA) pf Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs Soap dish, CP fancy type CAT No. ACN-1131N Jaquar/BA-259 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs CP towel rail 20mm dia and 600mm long, D type including brackets conforming to CAT No. ACN-111N of Jaquar/ BA-20 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs Health faucet CAT No. ALD-583KN of Jaquar/ BEA-85 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repair stop valve / angular stop cock CP fancy type conforming to CAT No. 053 of Jaquar/ 9210 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repair concealed, lond shank stop valve / angular stop cock CP fancy type conforming to CAT No. 053 of Jaquar/ 9210 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs CP toilet paper holder conforming to CAT No. ACN-1151N of Jaquar/ BA-38 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs CP towel ring round with round flange conforming to CAT No ACN-1121 BN of "Jaquar" / 9218 of "Prayag" or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs CP wall mixer 3 in 1 including telephone shower for 15mm bore of pipe conforming to CAT No.CON 281 and HSH -1939 of Jaquar/ PIS-70 and BH-73 of Prayag or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs 2 way bib cock, CP fancy type with wall flange conforming to CAT No. CON 041N of Jaquar or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs Brass chromium plated shower rose 125 dia with 235 mm long arm with or without swivel joints, including fixing to steel pipe or union "Jaquar" or of equivalent make specified here-in-after complete all as specified and directed.
S&F in repairs Pillar cock, CP fancy type, long neck with aerator CAT No CON-021KN of "Jaquar" or of equivalent make as specified here-in-after complete all as specified and directed
Supply and fix in repairs elbow operated pillar tap cast copper alloy, brass chromium plated, screw down, single leaver surgical purpose with extended operating lever of cat ID-FLR-5031N of Jaquar / CERA / Hindware complete all as specified and directed
S& F in repair 5mm thick sheet glass corner shelf, 250mm radius including CP railing and CP brackets, complete all as specified and directed.
S&F in repairs PVC syphon with rod suitable for low level flushing cistern including PVC handle with adjustable lever (flushing cistern kit) complete all as specified and as directed
S&F in repairs flush handle PVC with adjustable Lever and hook suitable for low level flushing cistern complete all as specified and as directed
S&F in repairs mild steel chromium plated grating (round) 125 mm dia fixed over floor / nahani trap (with hole OR without hole), complete all as specified and directed.
S&F in repairs vitreous china ceramic white single piece WC (S or P trap with UF soft close seat cover, hinges, accessories set, size 365x655x765 mm, product Code : LYS-WHT-38851SSM of Jaquar of equivalent make as mentioned here-in-after, complete all as specified and directed
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm, suitable for hot & cold water complete all as specified and directed.
S&F in repairs PVC flexible waste pipe 32/40mm bore of suitable length as required for wash hand basin or sinks, complete all as directed.
M&L for PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) of 75mm thick, laid in alternate bays including finishing the surfaces even and smooth using extra cement including demolition of existing PCC from any position and removing of debries and demolished materials outside the MD land complete all as specified and directed by Engineer-in-Charge
S&F in repair high density 40mm bore polythylene pipes (HDPE) of pressure rating 6 kg/cm2 fixed complete to wall or in floors with necessary socket, elbow & bend etc complete fixed to wall or in floors etc complete all as complete and directed.
M&L for old size fly ash bricks, straight or curved on plan exc. 6 m mean radius built in CM 1:6 including dismantling of old existing brick / stone /PCC block wall etc. complete all as specified and directed.
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:3:6) type C-1 using 20 mm graded aggregate and setting in CM 1:6 including dismantling of brick work or PCC or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as complete and directed.
M&L for 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 to be finished even and smooth (without using extra cement) including taking down cement old unserviceable plaster and removing of debries & demolished materials etc outside the MD land complete all as specified and directed by Engineer-in-Charge
M&L for 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 to be finished even and smooth (without using extra cement) complete all as specified and directed.
S&F in repairs 2mm thick PVC fibre mirror cabinet of size 450x325x120mm and fixed to wall after taking down of old one, complete all as specified and directed
Supply only liquid water proofing compound complete all as specified and directed
M&L for preparation of new plastered surface of ceiling and applying two coats of oil bound distemper over and including 3 mm thick wall care putty complete all as specified and as directed.
M&L for prepration of newly plastered wall surface and applying two coats of cement based paint over a coat of chalk whiting complete all as specified and as directed.
Dismantling structural steel work including doors, gates etc, complete all as specified and directed.
S&F roof sheeting prepainted galvalume aluminium zinc coating 150 gms, GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including dismantling of old unserviceable sheet complete all as specified and as directed.
S&F roof sheeting prepainted galvalume aluminium zinc coating 150 gms GI based plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including dismantling of old unserviceable sheet complete all as specified and as directed.
S&F in repairs 0.63 mm thick grade ‘O’ galvanised corrugated mild steel sheeting with garde ‘B’ corrugation, zinc coating @ 120 gram per sqm inclusive of both sides, laid with two corrugation side lap fixed with 'J' or 'L' or crank hooks including with washers as in roof covering etc. including dismantling of old unserviceable CGI sheet of any type complete all as specified and directed
M&L for filleting in any position and to any shape in CM 1:3, sectional area exceeding 25 Sqcm but n. exc. 50 Sqcm complete all as specified and directed.
Supply & fixing rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates of etc. confirming to Fe-410-W (Gde-E-250) Quality-A, complete all as specified and directed.
S&F 35 mm thick factory made 2nd class hardwood gauged and skelton shutters open rebated and prepared to receive glass / gauze etc ( without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc size of members of shutters as specified in SSR part-I Section 8 cluse 8.24(a) and Fitted to chowkats complete all as specified and as directed.
S&F 35mm thick, factory made, plain framed, panelled shutter (Any number of panel) with IInd class hard wood rail & style, lock rail and panel of 9 mm BWP commercial ply or 12 mm thick vaneered particle board with commercial vaneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F 30mm thick flush shutters, solid core contruction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Taking down shutters of any description exc 1.0 sqm but n.exc 2.00 Sqm each and rescuring or easing & adjusting after repair in door opening and connected carpentry work and refixing at same opening complete all as speicified and directed.
Taking down shutters of any description n. exc 1.0 sqm each and rescuring or easing & adjusting after repair in door opening and connected carpentry work and refixing at same opening complete all as speicified and directed.
Taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each, complete all as specified and directed.
Taking down / cutting of steel windows shutter by means of gas cutter with out disturbing of sofit / jambs / cills etc of any description n. exc. 1.5 sqm (without taking off guard bar) complete all as specified and as directed.
S&F three track sliding window with two or more shutter with 4mm thick tinted glass one shutter using stainless steel wire cloth 0.36 mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc by using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge :- (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S & F ventilators / louvers using 4mm thick x 10cm wide froasted glass strips by using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make including with rubber beading etc complete all as specified and directed by Engr-in-Charge:- (a) SP 20048 (b) Glazing clips 19352
S&F Aluminium powder coated single leaf door on pivots along with and including hydraulic door closer, door lock, handle, 5mm thick plan glass fixed with rubber beading in top panel and glazing clips MS clamps and 12mm thick laminated particle board as in bottom panel (both side laminated) using following sections as given in 'JINDAL' or of equivalent make including with rubber beading etc complete all as specified and directed by Engr-in-Charge:-. (a) Rectangular tube - 14005 (b) Vertical rail - 19501 (c) Top rail -19503 (d) Middle rail -20060 (e) Bottom rail- 19511
S&F in repairs powder coated anodised aluminium fixed partition, comprising of at least 63.50 x 38.10 x 1.85 mm aluminium section with and including jointing cleats, aluminium snap beading 20x15mm, rubber gasket, glazing clips, 5mm thick frosted glass in top and 12mm thick pre-laminated particle board (both side laminated) in bottom panel, fixed with and including rubber beading and glazing clips & all other fittings required to erect as per site requirement complete all as approved by Engr-in-charge
S&F stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.4 mm and fixed with stanless steel stepple to aluminum window shutter including taking down shutter from frame and refixing in frame complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.4 mm and fixed with stanless steel stepple to aluminum window shutter including taking down shutter from frame and refixing in frame complete all as specified and directed.
Taking down chowkhat or frames n. exc. 1.5 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
Taking down chowkhat or frames exc. 1.5 sqm but n. exc. 4 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with M.S square tube, supplying & fixing in opening as per specifications, drawings, complete al as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles plain colour PVC sheet for top rail , lock rail & bottom rail either side & as gap isert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC beading and jointed together with solvent cement, supplying and fixing in the frame at site as per SSR Pt-I specification & drawing.
S&F in repairs, 18 mm thick PVC sheet shutter, one side prelim of any shade as in cupboard or kitchen cabinet etc complete all as specified.
S&F pressed steel frames of size 105X60 mm for doors with one or more rebates including necessary lugs, hinges-03 Nos, lock strikes plate, including providing PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) to fill up the hollow portion of the frame complete all as specified and directed.
S&F pressed steel frames of size 125X60 mm for doors with one or more rebates including necessary lugs, hinges- 06 Nos, lock strikes plate, including providing PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) to fill up the hollow portion of the frame complete all as specified and directed.
S&F 300mm length of bolt, aluminium alloy, anodised, sliding door bolts with hasp staple (bolt type) anf fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast alluminium alloy, complete all as specified and directed.
S&F in repairs 300mm length of bolt, aluminium alloy, anodised, sliding door bolts with hasp staple (bolt type) anf fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast alluminium alloy, complete all as specified and directed.
S&F 150 mm long aluminium, anodised, barrel tower bolts of extruded section ISI marked, fabricated type complete all as specified and directed
S&F in repairs 150 mm long aluminium, anodised, barrel tower bolts of extruded section ISI marked, fabricated type complete all as specified and directed
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised ISI marked complete all as specified and directed .
S&F in repairs 150 mm long extruded aluminium alloy handles, fabricated type anodised ISI marked complete all as specified and directed .
S&F 100 mm size hinges medium weight, cold rolled mild steel and fixed complete all as specified and as directed
S&F 100mm dia Brass handles, cast type, polished bright cupboard handles fixed with nuts screws and washer complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish, width of flaps (When open) 30mm, complete all as specified and directed.
S&F of magnet catches and striking plate of suiatble size, complete all as specified and directed.
S&F in repair Aluminium (Extruded section body door closer hydroulically regulated designation No.3 universal typt , suitable for door shutter of 851 to 1000 mm in width and weight between 61 to 80 Kg complete all as specified and directed.
M&L for preparation of new steel surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F mild steel 300 mm, ordinary rat tail pattern, spring including rollar and rollar plate , complete all as specified and directed.
S&F in repairs mild steel 300 mm, ordinary rat tail pattern, spring including rollar and rollar plate , complete all as specified and directed.
M&L for running welding in repairs not exc. 6mm thick plates and angles complete all as specified and as directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other part made of mild steel heavy duty, complete all as specified and directed
S&F in repairs plastic water closet (EWC) seat cover white closed pattern with flat bottom and cover including mild steel chromium plated hinging device complete all as specified and as directed
M&L for framed work as in grills / guard bars, gratings etc. with ends of bars shouldered and / or rivetted, or forged into spikes; framed guard bars; barred iron door, railings and similar work conforming to Fe 410-0 or Fe 310-0 including dismantling of old unserviceable frames, grills / gratings etc or wrought iron work of any description and any position complete all as specified and directed.
S&F mild steel framed work for doors or gate of angle, plain sheet or other sections etc. complete drilled for fixing of steel sheeting, incl necessary welding etc of grade Fe-410-w(Gde-E-250 quality B) including dismantling of old unserviceable frames including doors or wrought iron work of any description and any position complete all as specified and directed.
M&L for removal of air lock / blockage of water in GI tubing 15mm bore of any type including taking down (if required), cleaning the pipe or fittings etc and re-fixing the same in position complete all as directed by Engr-in-charge Note:- Removing 01 air lock / blockage from pipe line and make it functional shall be measured as one Job.
M&L for removal of air lock / blockage of water in GI tubing 20mm bore of any type including taking down (if required), cleaning the pipe or fittings etc and re-fixing the same in position complete all as directed by Engr-in-charge Note:- Removing 01 air lock / blockage from pipe line and make it functional shall be measured as one Job.
S&F in repairs 100 mm size stainless steel fancy type handles complete all as specified and directed
S&F in repair 20 mm dia aluminium powder coated curtain rods, fixing fancy type, medium weight with and including bracket , stops, latoo etc (Minimum 02 Nos. for each opening) including taking down old one complete all as specified and directed by Engineer-In-Charge.
S&F in repairs floor door stopper of aluminium alloy body double tongue annodised with rubber shoe and fixed of size 140 mm all as specified and as directed.
S&F in repairs, stainless steel plate rack of size 36inch x 39 inch x 10inch, made out of 0.63mm thick stainless steel sheet (Grade AISI 304 18/8), including stainless steel screws and round pipe etc, fixed to wall with screws & royal plugs complete all as specified and as directed. Make – Blue Star Silver Shine Cat No.KPR-315 or equivalent from Nirali / Jain Brothers Sanitation Pvt Ltd (Jayna)
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches, sockets, ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down carefully existing main switch, MCB DB boxes with MCBs, sheet metal boxes etc of any size, any capacity from boards complete all as specified and as directed
M&L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area),single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC casing caping including all accessories etc., heavy duty ISI marked, mild steel concealed sunken boxes, 1.6 mm thick and 60 mm depth with earth dolly duly painted with two coat of black bituminous paint over a coat of red oxide primer with laminated bakelite sheet of minimum thickness of 3mm suitable for switches / sockets, etc, including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core green PVC insulated FRLS cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for the following:- (a) One light/fan/ point controlled by one switch.
(b) One 5 Amps Socket outlet point controlled by one switch on independent board.
(c) One 5 amps socket outlet point on same board with other switches
(d) One bell/buzer point controlled by one bell push
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm(Nominal area),single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in the existing conduit ,with mild steel concealed sunken boxes with earth dolly with laminated bakelite sheet of min. thickness of 3mm sheet suitable for switches, sockets, etc including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core green PVC insulated FRLS cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for the following:- (a). One light/fan point controlled by one switch.
(b) One 5 Amps Socket outlet point controlled by one switch on independent board.
(c) One 5 amps socket outlet point on same board with other switches
(d) One bell/buzer point controlled by one bell push
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 4 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into existing conduit including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-Two meter length of 4 sq mm & 1 meter length of 2.5 Sqmm stranded copper conductor cable shall be measured as one unit length
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into existing conduit including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-Two meter length of 6 sq mm & 1 meter length of 4 Sqmm stranded copper conductor cable shall be measured as one unit length
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into existing conduit including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-Two meter length of 10 sq mm & 1 meter length of 6 Sqmm stranded copper conductor cable shall be measured as one unit length
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 4 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including PVC casing capping including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:- One meter length of PVC casing caping and 3 runs of 4 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including PVC casing capping including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:- One meter length of PVC casing caping and 3 runs of 6 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, two core, PVC insulated, copper conductor cable drawing into and including PVC casing capping including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:- One meter length of PVC casing caping and 6 runs of 6 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 2x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty concealed PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of conduit and 6 runs of 6 sq mm stranded copper conductor cable shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS with flexible wiring cable confirming to IS: 694-1990 with and including continuous earth wire of size 2x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty concealed PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing including taking down of old unserviceable sub main wirings complete all as specified & directed. Note:-One meter length of conduit and 6 runs of 6 sq mm stranded copper conductor cable shall be measured as one unit length.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked drawn in existing conduit,with mild steel concealed sunken boxes 1.6 mm thick & 60 mm depth with earth dolly duly painted with two coat of black bituminous paint over a coat red oxide primer with laminated bakelite sheet of min. thickness of 3mm sheet suitable for switches, including PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core green PVC insulated FRLS cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for 15 Amps socket outlet on independent board
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC casing caping including all accessories etc. heavy duty ISI marked, with mild steel concealed sunken boxes 1.6 mm thick & 60 mm depth with earth dolly duly painted with two coats of anti corrosive paint over of red oxide primer, internally, covered with laminated bakelite sheet of min. thickness of 3mm sheet suitable for switches, including PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core green PVC insulated cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for for 15 Amps socket outlet point on independent board
M&L for point wiring with 1.5 sqmm PVC insulated copper conductor FRLS cable 1100 Volts grade complete with & including PVC casing and caping and accessories with PVC ISI marked, switch board, including continuous PVC insulated copper earth wire 1.5 Sqmm connected to common earth dolly complete all as specified and directed, for the following :- (a). One light/fan/ point controlled by one switch.
(b). One 5 Amps Socket outlet point controlled by one switch on independent board
(c) One 5 amps socket outlet point on same board with other switches
(d) One bell/buzer point controlled by one bell push
M & L for point wiring with 2.5 Sqmm copper conductor FRLS cable for 15 amps socket outlet point on independent board and continuous PVC insulated copper earth wire 1.5 Sqmm in PVC casing and capping and including PVC mounted switch board complete all as specified and directed.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm(Nominal area),single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC rigid conduits 20 mm or higher dia as required at site, totally concealed in walls/floors/ceiling including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made pressed steel housing, totally concealed in walls suitable for modular switch socket accessories with earth dolly with suitable modular plate etc, including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for the following:- (a). One light/fan/ point controlled by one switch
(b). One 5 Amps Socket outlet point controlled by one switch on independent board
(c) One 5 amps socket outlet point on same board with other switches
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 2.5 Sq.mm(Nominal area),single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC rigid conduits 20 mm or higher dia as required at site, totally concealed in walls/floors/ceiling including all conduit accessories / fittings / junction boxes / inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made pressed steel housing, totally concealed in walls suitable for modular switch socket accessories with earth dolly with suitable modular plate etc, painted with two coats of anti corrosive paint over of red oxide primer, internally, covered PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for 15 amps socket outlet point on independent board
S&F modular type switch 6A single pole,one way,240 volts, Cat.No 6730 00 Make-Legrand "Myrius series", complete all as specified and directed.
S&F multipurpose socket outlet 16A -2/3 pin,2 module for 230 volts flush type.cat.No 6730 42 Make-Legrand "Myrius series", complete all as specified and directed.
S&F modular type switch 16A single pole,one way,1 module, 240 volts, Cat.No 6730 00 Make-Legrand "Myrius series", complete all as specified and directed.
S&F modular universal socket 2 module outlet 6 amps 5 pin 230 volts flush typeMake-Legrand :Myrius series", complete all as specified and directed.
S&F in replacement of modular ceiling fan step regulator 100 Watts, 2 module, electronic step type, suitable for fan 48"/56" sweep complete all as specified and directed.
S & F 240 V, 20 Amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, SPN, complete all as specified and directed.
S&F piano type switch 5 amps single pole,240 volts, complete all as specified and directed.
S&F bell push, flush type, 5 amp, 240 volts, complete all as specified and directed.
S&F bell electrical ding dong including hard\wood board bell push,flush type,5 amp,240 volts, complete all as specified and directed.
S&F ceiling rose surface type three terminals, 240 volts, complete all as specified and directed.
S&F socket outlet 5 amps 5 pin 230 volts flush type on same board, complete all as specified and directed.
S&F socket outlet multipurpose 2 in 1, 5/15 amps, 230 volts flush type, complete all as specified and directed.
S&F piano type switch 15 amps single pole, 240 volts, complete all as specified and directed.
S&F lamp holder (Angle/bracket) insulated body, with back plate for batten fittings with and including 5 watt LED bulb of make-Philips / Wipro / HPL, complete all as specified and directed.
S&F in replacement of ceiling fan regulator, electronic step type, delux, suitable for fan 48"/56" sweep complete all as specified and directed.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm(Nominal area),single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC rigid conduits 20 mm or higher dia as required at site, totally concealed in walls/floors/ceiling including all conduit accessories/fittings/junction boxes/inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made pressed steel housing, totally concealed in walls suitable for modular switch socket accessories with earth dolly with suitable modular plate etc, including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box with and including making good of the disturbed surfaces will and match with existing surfaces complete all as specified and directed for the following:- (a) One light/fan/ point controlled by one switch.
(b) One 5 Amps Socket outlet point controlled by one switch on independent board.
(c) One 5 amps socket outlet point on same board with other switches.
S&F bell push, flush type, 5 amp, 240 volts, Modular type, complete all as specified and directed.
S&F MCB DB TPN 4 way double door with 200 amps rated busbar 415 V, recess mounted / wall mounted complete all as specified and directed by Engineer in charge. Make:-Legrand / Scenider / HPL
S&F MCB DB SPN 8 way double door with 200 amps rated busbar 240 V, recess mounted / wall mounted complete all as specified and directed by Engineer in charge. Make:-Legrand / Scenider / HPL
S&F vertical 4 way TPN double door,recess mounted/wall mounted DB incl one number, MCCB as incomer 3 pole and neutral of 100A rated capacity & 16KA breaking capacity, pre-fitted at factory complete all as specified and directed by Engineer in charge. Make:-Legrand / Scenider / HPL
S&F MCB DB SPN 4 way double door with 200 amp rated busbar, 240V recess mounted with common earth dolly complete all as specified and directed by Engineer in charge. Make:-Legrand / Scenider / HPL
S&F MCB SP 6-32 amps,10 KA, 'C' series, complete all as specified and directed
S&F MCB SPN 10-40 amps,10KA, 240V,'C' series complete all as specified and directed
S&F MCB TPN 63 amps ,10 KA, 415 V, 'C' series complete all as specified and directed
M & L for fixing earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 4 mm dia GI Wire, complete all as specified and directed.
S&F in repairs LED tube light fitting complete with all fitting and fixing accessories, 1X20 Watt pre-wired with high efficiency electronic driver, glare free, smooth light distribution, CAT Part No.Garnet 20 W LED (D532065) of Wipro or of equivelent cat part in Havells / HPL / Philips, including taking down of old existing one complete all as specified and directed.
S&F in repairs integral LED Security Light Luminaire 30 Watt comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe (including GI pipe) complete with accessories conforming to Cat Part No : HPLLEDSL3060S of HPL or of equivalent cat part in Wipro / Phillips / Havells including taking down of old existing one complete all as specified and directed.
Taking down ceiling fans and removing to workshop for servicing, cleaning, lubricating and applying one coat of synthetic enamel paint with spray machine including writing MES No., replacement of split pin, rubber bush and other spare parts required if any including fixing with new PVC cable with stranded copper conductor of size 0.75 Sqmm and re-fixing the fans at the same locations, complete all as directed by Engr-in-charge. Note:- Spares like Capacitor, bearing, terminal connector, gun metal bush, PVC cable shall be measured and paid separately as “Supply only”
Taking down exhaust fans and removing to workshop for servicing, cleaning, lubricating and applying one coat of synthetic enamel paint with spray machine including writing MES No., replacement of split pin, rubber bush and other spare parts required if any including fixing with new PVC cable with stranded copper conductor of size 0.75 Sqmm and re-fixing the fans at the same locations, complete all as directed by Engr-in-charge. Note:- Spares like Capacitor, bearing, terminal connector, gun metal bush, PVC cable shall be measured and paid separately as “Supply only”
Taking down wall mounted fans and removing to workshop for servicing, cleaning, lubricating and applying one coat of synthetic enamel paint with spray machine including writing MES No., replacement of split pin, rubber bush and other spare parts required if any including fixing with new PVC cable with stranded copper conductor of size 0.75 Sqmm and re-fixing the fans at the same locations, complete all as directed by Engr-in-charge. Note:- Spares like Capacitor, bearing, terminal connector, gun metal bush, PVC cable shall be measured and paid separately as “Supply only”
S&F new fan motor assembly in replacement of burnt out and unserviceable fan motor assembly complete including with double bearing, copper winding with metal plate top & bottom side suitable for usha or any other existing make at any location complete all as specified and as directed by Engr-in-Charge.
Supply only capacitor of 2.5mfd, 230 volts, Make - Asian or equivalent, complete all as specified and as directed
Supply only capacitor 4mfd 230 volts Make - Asian or equivalent, complete all as specified and as directed
Supply only SKF bearing 6200 to 6203 ZZ Make - SKF or equivalent complete all as specified and as directed
Supply only terminal conductor 3 way Bakelite complete all as specified and as directed
Supply only self adhesive PVC electrical Insulation tape 7 mtr long with superior quality complete all as specified and as directed
Supply only PVC three core sheathed cable with stranded copper conductor of size 1.00 sqmm, complete all as specified and as directed
S&F in repairs PVC three core sheathed cable with stranded copper conductor of size 2.50 sqmm, complete all as specified and as directed
Supply only brass gun metal bushing suitable of size 1200/1400mm sweep ceiling fan, complete all as specified and as directed
Supply and Fix in replacement canopy for ceiling fans (Set of two) complete all as specified and as directed
Supply and Fix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm swwep ceiling fan, complete all as specified and as directed.
S&F in replacement two feet long down rod suitable for 1200/1400 sweep ceiling fans, made out of GI pipe medium grade, 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
S&F in replacement four feet long down rod suitable for 1200/1400 sweep ceiling fans, made out of GI pipe medium grade, 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
S&F in replacement six feet long down rod suitable for 1200/1400 sweep ceiling fans, made out of GI pipe medium grade, 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
M&L for preventive maintenance of storage type electric water heater (Geyser) of capacity 25/50 ltrs comprising of the following tasks at different locations and of any make including replacement of defective parts etc complete all as directed by Engr-in-charge:- (a) Inspection of geyser after opening bottom cover plate. (b) Examine water tightness of storage tank. (c) Carry out / make functional of all stop cocks, pressure reducing valves etc. to ensure trouble free movement of the working parts. (d) Replacement of washers & glands of defective taps to ensure water tightness & smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and made good earth continuity of electrical items. (g) Check and correct temperature setting of thermostats and test its functioning. (h) Checking and adjustments of pressure reducing valves. (i) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection & cleaning of seat and ensure that the waste hole is not blocked / chocked. (j) Testing of Geysers after repairs / maintenance in all respect for smooth functioning. Note:- Spares like heating element, valve, thermostate, indicator lamp, tanks etc shall be measured and paid separately as “Supply only”
Supply only thermostat ISI marked suitable for 25 to 50 litres capacity of Geysers, complete all as specified and as directed.
Supply only safety valve / dead weight valve ISI marked suitable for 25 to 50 ltrs capacity of Geysers, complete all as specified and as directed.
Supply only heating element for 1KW /1.5 KW rating as required at site(any type) including rubber washers (ISI marked), complete all as specified and as directed
Supply only storage inner tank made out of copper sheet suitable for 25 Ltrs capacity geyser, make & size as per existing geyser, complete all as specified and as directed by Engr-In-Charge
Supply only storage inner tank made out of copper sheet suitable for 50 Ltrs capacity geyser, make & size as per existing geyser, complete all as specified and as directed by Engr-In-Charge
M&L for replacement of burnt winding of ceiling fan 1200/1400mm sweep working on 230 volts AC supply and rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and refixing the fan at positions complete all as directed by Engr-in-charge.
M&L for replacement of burnt winding of exhaust fan upto 300mm sweep working on 230 volts AC supply and rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and refixing the fan at positions complete all as directed by Engr-in-charge.
M&L for replacement of burnt winding of wall mounting fan of any size,working on 230 volts AC supply and complete rewinding the same with super enamelled copper wire of same guage and weight including replacement of insulation paper, varnishing, heating up and testing etc complete including taking down and re-fixing the fan at positions complete all as directed by Engr-in-charge.
S&F in repairs apparatus plate suitable for Geyser of 25 to 50 ltrs capacity, complete all as specified and as directed
Supply & fix in repairs PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe, 45/60cm long suitable for cold water as per site requirement complete all as specified and as directed.
Supply & fix in repairs PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe, 45/60cm long suitable for hot water as per site requirement complete all as specified and as directed.
Supply & fix in replacement of 15 Amps plug top and making connection complete all as specified and as directed
S&F in repairs non-return valve of 15mm / 20mm dia of brass, ISI marked complete all as specified and as directed
M&L for repair to Geysers inner water tank of 25 to 50 litres capacity including gas welding / brazing for water tightness and testing complete all as specified and as directed
S&F indicators (Red/Green/Yellow) suiatble for Geysers 25 to 50 litres capacity complete all as specified and as directed
S&F gasket rubber ring for Heater plate of any size Geysers complete all as specified and as directed .
S&F inspection cover for outer container of Geysers 25 to 50 ltrs complete all as specified and as directed
S&F outer container suitable for 25 litres capacity geyser, made out of 14 gauge CRCA sheet duly painted complete all as specified and as directed .
S&F outer container suitable for 50 litres capacity geyser, made out of 14 gauge CRCA sheet duly painted complete all as specified and as directed .
M&L for preparation of old painted surfaces of geyser of any capacites by scrubbing, cleaning with sand paper / wire brush etc making good surfaces and applying a coat of synthetic enameled paint by using spray gun machine in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified & directed
S&F in replacement of smart glow recess mounting LED 2'x2' luminaries of 36 Watt with an inbuilt sensor thus avoids unwanted hassle of creating space for sensors, white acrylic drop light dissipator white powder coated CRCA housing with LED, Plane front frame fixed to housing, Concave acrylic diffuser enables lighting, Cat Part No RC 383B LED 36S-6500 PSU OD WH PIR of HPL or of equivalent cat part in Philips / Wipro / Havells complete all as specified and directed.
S&F in replacement of sleek LED Cadila mirror light fitting complete in all respect having high output diffuser of 2 feet length, 9 W LED Cat Part No HLPLEDCAD09CW of HPL or of equivalent cat part in Havells / Philips / Wipro complete all as specified and directed.
S&F in repairs electronic driver of 34/36 watts capacities of existing make, complete all as directed by Engr-in-Charge.
S&F in repairs electronic driver of 5-9 watts capacities of existing make, complete all as directed by Engr-in-Charge.
S&F in repairs electronic driver of 12-15 watts capacities of existing make, complete all as directed by Engr-in-Charge.
S&F in repairs electronic driver of 18-20 watts capacities of existing make, complete all as directed by Engr-in-Charge.
Supply and fixing in repairs PVC body fresh air ventilation fan of 200mm sweep complete all as specified and as directed by Engr-in-Charge. (Make :- Bajaj/cromptan/Havells/Usha)
Supply and fixing in repairs PVC body fresh air ventilation fan of 250mm sweep complete all as specified and as directed by Engr-in-Charge. (Make :- Bajaj/cromptan/Havells/Usha)
Supply and fixing in repairs PVC body fresh air ventilation fan of 300mm sweep complete all as specified and as directed by Engr-in-Charge. (Make :- Bajaj/cromptan/Havells/Usha)
S&F PVC rectangular block suitable for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 100mmx100mm and 50mm deep, including making good of disturbed surfaces and match with existing surfaces etc complete all as specified and directed
S&F PVC rectangular block suitable for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 175mmx100mm and 50mm deep, including making good of disturbed surfaces and match with existing surfaces etc complete all as specified and directed.
S&F PVC rectangular block suitable for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 200mmx150mm and 50mm deep, including making good of disturbed surfaces and match with existing surfaces etc complete all as specified and directed.
S&F PVC rectangular block suitable for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 250mmx200mm and 50mm deep, including making good of disturbed surfaces and match with existing surfaces etc complete all as specified and directed.
S&F PVC rectangular block suitable for mounting, switches, sockets, fan regulator etc with and including cover laminated sheet cover of size 350mmx300mm and 50mm deep, including making good of disturbed surfaces and match with existing surfaces etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m GI pipe for protection of 4mm dia GI earth wire for each earthing.
UNIQUE ENGINEERS (BID ID -3116355)
SARATH ENTERPRISES (BID ID -3108928)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .