| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹22.7 L+₹1.2 L (5.55%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹24.3 L+₹2.8 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹26.8 L+₹5.3 L (24.5%)Rejected-Finance MOH SWAMI PADAM JAHANGIRPUR GREATER NOIDA GAUTAM BUDH NAGAR UP 203141 | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 203141 | L4 | Rejected-Finance Not being lowest tender |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA
GE AF TA GWALIOR-474020
REPAIR/MAINT OF AHUs AND CONNECTED WORKS IN TECH AREA AT AF STN GWALIOR
2022_MES_540907_1
8900/1414/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TA Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹60,000
Yes
30 Sept 2022
26 Jul 2022
7 Sept 2022
26 Jul 2022
30 Aug 2022
9 Aug 2022
60 days
Amount
Disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position and of capacity up to 10000 CFM for overhauling and servicing including taking out existing shaft, blower, drum, pulley and dehumidifier pump etc. of air handling unit, checking thoroughly the serviceability of the parts, dismantling the parts, fixing the serviceable parts in position, replacement of the defective/non-functional /unserviceable parts /spares, reassembling, commissioning, fixing in position and testing of the air handling unit on full load for its smooth and trouble free operation complete all as specified and directed . Note :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only'. (ii) Rates quoted by the contractor shall include the cost of transportation of any part of the AHU unit to and from approved workshop for their repair and alignment.
All as per item No 1.01 here-in-before but for air handling unit of above 10000 to 20000 CFM capacity
All as per item No 1.01 here-in-before but for air handling unit of above 20000 to 30000 CFM capacity
Supply only the following spares / parts suitable for Air handling units repaired under respective Sch ‘A’/BOQ ser item No. 1.01 to 1.03 for servicing / overhauling of AHU complete all as specified and directed. (a) Pedestal bearing no NTN 205 J (Japan) or equivalent of make SKF /NBC complete all as specified and directed
(b) Pedestal bearing no NTN 206 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed
(c) Pedestal bearing no NTN 207 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed
(d) Pedestal bearing no NTN 211 J (Japan) or equivalent of make SKF/NBC complete all as specified and directed
(e) Mild steel shaft pulley 8” dia, B section, double groove inner bore 32mm with suitable slot for key complete all as specified and directed
(f) Mild steel shaft pulley 8” dia, B section, three groove inner bore 25mm with suitable slot for key complete all as specified and directed
(g) Mild steel shaft pulley 4” dia, B section, double groove inner bore 25mm with suitable slot for key complete all as specified and directed
(h) Cast copper alloy gate valve 20mm nominal bore, screwed down high pressure, with crutch or butter fly handlecomplete all as specified and directed
(f) Cast copper alloy gate valve 25mm nominal bore, screwed down high pressure, with crutch or butter fly handlecomplete all as specified and directed Note for Item No 2.01 to 2.09: (i) Cost element of removing unserviceable parts, fixing and testing of the new items/ parts is deemed to be included in the respective rates quoted by the contractor under respective Sch ‘A’ item No. 1.01 to 1.03 here-in-before for servicing / overhauling of AHU. (ii) Contractor shall have no claim on account of variation of quantities of these items/non execution of any of the above items and contractor shall be paid for as pr quoted rates only for the parts actually replaced.
S&F ‘V’ belts of following cross section, pitch length & size including disconnection and taking down of ‘V’ belts from motors complete all as specified and directed, Make : Fenner / Hilton. (a) Cross section 17 x 11 mm & pitch length 4080 mm of size B-159
(b) Cross section 17 x 11 mm & pitch length 2910 mm of size B-113
(c) Cross section 17 x 11 mm & pitch length 1770 mm of size B-68
(e) Cross section 17 x 11 mm & pitch length 1800 mm of size B-69
(f) Cross section 17 x 11 mm & pitch length 2300 mm of size B-89
(g) Cross section 17 x 11 mm & pitch length 1820 mm of size B-70
(h) Cross section 17 x 11 mm & pitch length 1010 mm of size B-38
(j) Cross section 17 x 11 mm & pitch length 2790 mm of size B-108
(k) Cross section 22 x 14 mm & pitch length 3360 mm of size C-130
(l) Cross section 22 x 14 mm & pitch length 2720 mm of size C-105
Dismantling and taking down existing fire dampers of any description and in any position and material and labour for supplying and fixing new fire damper, cubical movable louvers, operating mechanism, including its frame shall be fabricated and made to shape and size with using 20 gauge MS sheet and flat iron of suitable cross section all as directed by the Engineer-in-Charge.
Supply & fix in replacement the following filters suitable for Air handling units of air conditioning plants complete all as specified and directed by the Engineer-in-Charge (Make : Dyna, Tenacity, Airtech, Puromatic, Thermodyne, Spetam or equivalent make as approved by the GE) (a) Micro ‘V’ air filter nylon/fabric fibre, media of capacity 5 micron, 98% efficiency of size 610mm x 610mm x 305mm deep.
(b) --ditto – but of size 610mm x 305mm x 305mm deep
(c) Pre-air metallic air filter of 10 micron, 90% efficiency with GI sheet frame of size 600mm x 400mm x 48mm deep
(d) --ditto—but of size 500mm x 400mm x 48mm deep
(e) --ditto—but of size 610mm x 305mm x 50mm deep
(f) --ditto—but of size 610mm x 610mm x 50mm deep
(g) --ditto—but of size 610mm x 310mm x 50mm deep
M&L for servicig /descaling of Hot water generator up to 170 KW 3 phase, 415 volts and callibration testing of all functional with including replacement of any minor defective parts such as bolts, nuts and screw etc.
Disconnecting and taking out existing unserviceable strip heater of 14KW/3KW capacity of any description and in any position complete all as specified & directed.
Supply and fixing strip heater 3 KW, 230 volts fin type for AHU complete all as specified & directed.
Supply and fixing and commissioning hot water generator set heating element 14 KW complete including flushing of pipe line and brazing as required all as specified and directed for satisfactory operation of plant.
Supply and fixing in replacement of PCB for hot water generator of capacity 170KW complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repair of Aluminium fan set upto for upto 20TR AC plants with hub assembly sweep 1200 mm & 4 blades complete all as specified and directed
Supply and fixing in repair of Aluminium fan set upto for 20 to 40TR AC plants with hub assembly sweep 1400 mm & 4 blades complete all as specified and directed
Supply and fixing in repair of Aluminium fan set upto for 40 to 100TR AC plants with hub assembly sweep 1500 mm & 4 blades complete all as specified and directed
Supply and fixing in repair of Aluminium fan set upto for 100 to 150TR AC plants with hub assembly sweep 1500 mm & 4 blades complete all as specified and directed
Disconnecting, dismantling & taking up/down AC electric motors of any description and in any position from existing foundation of compressor/blowers/pumps/ cooling tower strip opening and dismantling of motor for servicing /overhauling, cleaning oiling/greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling motors, ensuring proper alignment of the motor with existing compressor / pumps/blower/cooling tower, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 1 HP to 5 HP 1 Phase/3 Phase 50 Hz
(b) 7.5 HP to 12.5 HP Three phase 50 Hz
(c) 15 HP to 20 HP Three phase 50 Hz
(d) 60 HP Three phase 50 Hz
Disconnecting, dismantling & taking up/down pump set and monoblock pump sets of AC plant of any description and in any position from existing foundation, strip opening and dismantling of Pumps for servicing/overhauling, cleaning oiling/ greasing and fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, reassembling the pumps ensuring proper alignment of pump, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities :- (a) 0.5 HP to 3 HP single phase 50 Hz
(b) 5.0 HP Three phase 50 Hz
(c) 7.5 HP Three phase 50 Hz
(d) 10 HP to 12.5 HP Three phase 50 Hz
(e) 15 HP to 20 HP Three phase 50 Hz Notes for Schedule `A'/BOQ Ser item No 11.01 to11.04 & 12.01 to 12.05 :- (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under respective item of overhauling and servicing mentioned here in before. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & from of pumps/ motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bots/washers/ packing etc with new one.
Taking out & removing old burnt out windings and rewinding of electric motors of following sizes with existing size copper super enameled wire including insulating material such as illuminous paper, Leatherized paper, cotton tape, glass sleeving, insulating varnish etc testing for the following capacities covered vide item 11.01 to 11.04 and 12.01 to 12.05:- NOTE : Taking down of motor, its servicing & overhauling, fixing on foundation in position, connecting and testing is deemed to be included in the respective item No 11.01 to11.04 and 12.01 to 12.05 of Schedule `A'/BOQ herein before. (a) 0.5 HP to 1.5 HP single phase 50 Hz
(b) 2.0 HP to 3.0 HP Three phase 50 Hz
(c) 5.0 HP Three phase 50 Hz
(d) 7.5 HP Three phase 50 Hz
(e) 10 HP to 12.5 HP Three phase 50 Hz
(f) 15 HP Three phase 50 Hz
(g) 20 HP Three phase 50 Hz
(h) 60 HP Three phase 50 Hz NOTE : - Bearing, Bush, Condenser, terminal plates etc will be measured and paid for separately under appropriate item of this Schedule.
Supply only ball Bearing/Roller Bearing of the following Sizes complete all specified and directed by the Engineer-in-Charge. (a) 6202Z
Supply only gun metal bushes suitable for following capacity of pumps of any make/model :- (a) 02 to 05 HP Pump
(b) 7.5 to 12.5 HP Pump
(c) 15 to 20 HP Pump
Supply only of MS star coupling L – 190 for pump and Motor as approved by GE. Note :- Fixing/ testing charges of these items are deemed to be included in the rates quoted by the contractor for respective Sch ‘A’/BOQ item Nos 11.01 to 11.04 and 12.01 to 12.05 here-in-before.
Supply only neck ring of Gun metal for suction side of pump suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Supply only cast iron gland plate for pumps suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Supply only gland bolts made out of high carbon forged steel complete with nuts & washers suitable for following capacity of pumps of any make/model : (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Supply only pump shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of pumps of any make/model : (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Supply only rotor motor shaft all as specified & directed by Engineer-in-Charge, suitable for following capacity of motor of any make/model:- (a) 5 HP, three phase, 50 Hz
(b) 7.5 HP, three phase, 50 Hz
(c) 10 HP, three phase, 50 Hz
(d) 12.5 HP, three phase, 50 Hz
(e) 20 HP, three phase, 50 Hz
Supply only pump impeller CI suitable for following capacity of pumps of any make/model:- (a) 5 to 12.5 HP, three phase, 50 Hz
(b) 20 HP, three phase, 50 Hz
Disconnecting and taking down existing unserviceable terminal plate of any description and in any position supply and fixing terminal plate, 3 phase, six wire, bakelite, star delta connection as required at site with brass studs, two nuts and two washer complete all as specified and directed for the following capacity of motors : - (a) 1 HP to 3 HP
(b) 5 HP to 10 HP
(c) 12.5 HP to 20 HP
Dismantling and taking down/removing of damaged fan blades of any description and in any position from electric motors all as directed and Supply and fixing Fan blades fabricated to shape and size of Zink Aluminum cast alloy as per sample for electric motor with key and key grove complete all as directed for the following capacity motors :- (a) 5 HP to 7.5 HP
(b) 10 HP to 12.5 HP
S&F of contactor LC1D38M7, 38 Amp with 1 NO+1NC auxilary contacts complete all as specified and directed
S&F of contactor MNX 18 Amp with 1 NO+1NC auxilary contacts complete all as specified and directed
S&F of contactor MNX 32/40 Amp with 1 NO+1NC auxilary contacts complete all as specified and directed
Supply and fixing in repair of overload relay MN-2, 14-23Amp complete all as specified and directed Make L&T/ Legrand/Schneider/Havells
S&F in repair including testing of electronic timer, time range from 3 seconds to 120 seconds suitable for 240/415 volts 50 HZ complete all as specified and directed
S&F in repair copper Lugs/terminal heavy duty of the following size complete all as specified and directed (a) 50 Sqmm
(b) 35 Sqmm
(c) 25 Sqmm
(d) 16 Sqmm
S&F in repair including testing of DOL motor starter 20 HP capacity, 415 Volts, 3 phase, 50 Hz AC supply, in sheet steel enclosure three phase with maximum relay range of 9A-15A fixed on wall of appropriate size fixed with suitable MS nut bolts/screws complete all as specified and directed.
Supply & Fixing Electric motor with extended shaft with fully 15HP & 950 RPM complete including testing complete all as specified and directed.Make :- Sabar/Kirloskar/CG
Taking up or down cast iron butterfly valve/sluice valve of any description and supplying, fixing and testing new valve complete all as specified and directed of following bores in existing pipe line after necessary cleaning etc. :- (a) 40 mm bore
(b) 50 mm bore
(c) 80 mm bore
(d) 100 mm bore
(e) 150 mm bore
(f) 200 mm bore
Supply and fix in repair rotary sprinkler with head cagin with frame and PVC header assembly for following capacity of cooling tower complete including PVC pipe of suitable size and length as required complete all as specified and directed of following size of AC Plant :- (a) up to- 50 TR
(b) 50 to 100 TR
(c) 100 to 170 TR
S K MECHANICAL WORKS
M/S Rakesh Verma
Radhe Krishn Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .