Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.6 LAccepted-AOC | L-1 | Accepted-AOC Admitted | |
| 2 | L-2₹4.4 L+₹81,961 (22.9%)Rejected-AOC | L-2 | Rejected-AOC Admitted | |
| 3 | L-3₹4.8 L+₹1.2 L (33.8%)Rejected-AOC KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L-3 | Rejected-AOC Admitted | |
| 4 | Rejected-Technical 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | - | Rejected-Technical Not Approved |
Tender Value
₹4.9 L
EMD Value
₹10,000
Closing Date
17 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (AF) Mount Abu
AGE (I) (AF) Mount Abu Distt- Sirohi (Raj) 307501
Repair and Maintenance of heating and cooling appliances at AF Stn Mount Abu and Gurushikhar under AGE I AF Mount Abu
2022_MES_553106_1
8512/02/E8 dt 20 Sep 2022
Open Tender
Civil Works
Item Rate
270 days
AGE (I) (AF) Mount Abu
As per tender documents
7 documents required · 7 mandatory
₹300
AGE (I) (AF) Mount Abu
₹10,000
Yes
22 Dec 2023
20 Sept 2022
24 Oct 2022
20 Sept 2022
17 Oct 2022
3 Oct 2022
Amount
M&L for Maintenance, servicing cleaning of the following air conditioner at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switchs condesor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items. (ii) After servicing the said ACs will be fixed to its original position. (a) 2 ton split type
(b) 1.5 ton split type
(c) 2 Ton window type
Supply and charging refrigerant F-22/R-22 (Mefron/Refron) gas for 1.5/2.00 Ton Split /Window AC at site after detection and rectification of any leackage in the system by sing CO2 gas and flushing the complete system thoroughly with nitrogen gas complete all as specified & directed.
Ditto as per item given above but R-134 complete all as specified & directed. Note : - The cost of nitrogen and CO2 gas used for leakage test and pressure test prior to filling charging gas shall be deemed to be included in this item rate
Disconnecting, cutting and taking out u/s sealed unit (Hermitically sealed) of any capacity and make and model against item Nos 4.00 to 6.00 here in after and removing materials for taking credit. complete all as specified & directed. Note:- Unserviceable compressor may be given with more than one cut
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for for split type AC of 1.5 ton Cap. With Gas Charging of any make complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for for split type AC of 2 ton Cap. With Gas charging of any make complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for refrigerator of 165 Ltrs capacity complete all as specified & directed.
shiftting of split AC of any size
S&F in repair New Indoor Unit for split AC of 1.5 Ton With Cordless Remote. complete all as specified & directed.
S&F in repair New Outdoor Unit for split AC of 1.5 Ton Without Compressore. complete all as specified & directed.
S&F in repair L &Key Valves 1/4 complete all as specified & directed.
S&F L in repair &Key Valves 1/2 complete all as specified & directed.
M&L for Maintenance, servicing cleaning of the water dispenser at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switchs condensor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items.
M & L in repair for installing , testing , commissioning hermitically sealed compressor suitable for water dispenser suitable for 5 ltrs cooling capacity of the existing make and model incl soldering, welding, brazing and testing on load for capacity 1/8 or 1/10 complete all as specified & directed.
S&F in repairs PVC drain out pipe, heavy duty 32/40mm dia, with wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity complete all as specified and directed by Engr-in-Charge.
Taking Down Old U/s Capacitor of any size
Supply & fix starting capacitor 50 mfd for window type room air conditoner 2.0 ton capacity Make Apcos/Natraj/Tesla/Spark complete all as specified & directed.
Supply and fix running capacitor 45 mfd Make Apcos/Natraj/Tesla/Spark complete all as specified & directed.
Taking down old u/s thermostat swich of any size
S&F thermostat switch for 2 Ton window type room air conditioner complete all as specified & directed.
taking down old u/s blower motor of AC any size
S & F Blower motor suitable for out door unit of split type AC 1.5 Ton complete all as specified & directed.
S& F Blower motor suitable for outdoor unit of split type AC 2Ton complete all as specified & directed.
S & F Blower motor suitable for indoor unit of split type AC 1.5Ton complete all as specified & directed.
S & F Blower motor suitable for indoor unit of split type AC 2 Ton complete all as specified & directed.
taking down of old u/s blower fan of AC any size
S& F blower fan as existing make and model / shape for window type room air conditioner 2 Ton capacity complete all as specified & directed.
S & F Blower fan suitable for indoor unit of split type AC 1.5 Ton complete all as specified & directed.
S & F Blower fan suitable for indoor unit of split type AC 2 Ton complete all as specified & directed.
taking out old u/sAir filter of ACany size
S & F air filter suitable for window type AC 2 Ton capacity as per samples complete all as specified & directed.
S & F air filter suitable for split type AC 1.5 Ton capacity as per samples complete all as specified & directed.
S&F in repair Condenser unit Suitable for 1.5 Ton Split AC Note: Gas Charge will Paid Seperately.
Taking down old u/s copper pipe of AC 1/4
S&F Copper pipe Of Size 1/4
Taking down old u/s copper pipe of AC 1/2
S&F Copper pipe Of Size 1/2
Maintenance, servicing & repair of refrigerator 165 ltrs capacity any make & modal cleaning the various components and replacement of U/s Spares complete all as specified & directed.: Note: Spares Will be paid In Other items of schedule.
Taking down, servicing, and refixing of Geyser 25 Ltrs by unscrewing of , MS clamps, inlet , outlet connections , any leakage & alike complete all as specified & directed. Note :- Spare parts will be measured & paid separately
taking down of old u/s heating element of 1.5/2 KW
S & F Heating element -1.5 KW complete all as specified & directed.
S & F Heating element -2 KW complete all as specified & directed.
taking down of old u/s thermostat swich for water heater of any size and any shape
S & F Thermostat switchof capacity 1.5/2.0KW complete all as specified & directed.
taking down of old u/s PVC connection
M& L for PVC connection 15mm x 60 cm long complete all as specified & directed.
taking down of old u/s rusted sheet metal enclosure complete
S&F Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Metallic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete Make Havells/MDS/Legrand complete all as specified & directed.
taking down old u/s PVC cable of size 3 core 70/.0076, Supply And fix the same.
Shifting of Geaser Of any Capacity.With Dismatling and making good the disturbed surfaces Cleaning after Refixing the geyser Including welding work of any part of geyser if required.
S&F Cable of size 2.5 Sqmm 3 Core
S&F Geyser Assembly of any size.
Choudhary Traders and Engineers
M/s Yash Electrical and Maintenance
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .