GEMC-511687752197105
Awarded to SRI SUDERSHAN TEXMART
₹5.5 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Portable fire extinguishers 4.5 kg | SEEMEX -FIRE EXTINGUISHERS | - | 98 NOS | ₹5,591 | 547,918 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.5 LQualified Make: SEEMEX
Model: SEEMEX -FIRE EXTINGUISHERS DELHI DELHI 110052 | NORTH DELHI | DELHI | 110052 | Make: SEEMEX
Model: SEEMEX -FIRE EXTINGUISHERS | ₹5.5 L | L1 | Qualified |
| 2 | L2₹10.7 L+₹5.2 L (95.0%)Qualified Make: SAFEPRO
Model: SAFEPROCO2New4.5 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: SAFEPRO
Model: SAFEPROCO2New4.5 | ₹10.7 L+₹5.2 L (95.0%) | L2 | Qualified |
| 3 | L3₹14.9 L+₹9.4 L (171.4%)Qualified Make: ceasefire
Model: CF-000063 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | Make: ceasefire
Model: CF-000063 | ₹14.9 L+₹9.4 L (171.4%) | L3 | Qualified |
| 4 | Disqualified Make: firequip
Model: FIREQUIP J 202 NARGIS AIRFORCE NAVAL HSG BOARD JALVAYU DEFENCE ENCLAVE CHS LTD PH I SEC 20 KHARGHAR NAVI MUMBAI 410210 RAIGAD MAHARASHTRA 410210 | RAIGAD | MAHARASHTRA | 410210 | Make: firequip
Model: FIREQUIP | - | - | Disqualified |
| 5 | Disqualified Make: ATCO
Model: ATCO AIRTECH ENTERPRISES JE 9 105 FIRST FLOOR OPPOSITE M BLOCK TIKONA PARK MALVIYA NAGAR NEW DELHI 110017 SOUTH DELHI | SOUTH DELHI | DELHI | 110017 | Make: ATCO
Model: ATCO | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Jul 2018, 1:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 98 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure Extinguishing Media Carbon Dioxide Based Carbon Dioxide Based Expellant Medium CO2 Extinguishing Medium CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) NA 1
2
NA Carbon Dioxide Based Fire Extinguisher Capacity (Kg) 4.5 4.5 Water Based Fire Extinguisher NA 2
NA 1/4 Capacity Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 16.7 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire false - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -30° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 NA - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) Test Pressure - 143 Bar Burst Pressure - 250 Bar - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 50.35 Fire Rating for Class -A Fire Extinguisher NA - Fire Rating for Class -B Fire Extinguisher 13B - Certification BIS Marking Yes - CM/L No.* with Validity Period 8886112 with validity of 31/03/2018 - Availability of Test YES - 2/4 Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification Test Report No. a) 110038A
squeeze grip type
ISI marked
EN PED approved and CE marked
Tamper- proof plastic safety seal and a metal pin
Used/Unused readiness Indicator
valve housing covered with a cap made of ABS plastic. - Test Report Date a) 12/12/2011 - Name of the Lab a) Fire Test & Research Laboratory - Address of the Lab a) 9th Milestone
SH-11
Sonipath- Gohana Road
Rattangarh
Sonipat-131001 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhay Bhan 226001
Fire Service hqrs 4th & 5th floor Indira Bhawan Ashok Marg Lucknow 98 30 EMD Required No ePBG Required No
236632
GEM/2018/B/33662
GeM Contract
Portable Fire Extinguishers IS 15683
GeM Contract
30 days
Uttar Pradesh; Lucknow
PRODUCT
Awarded to SRI SUDERSHAN TEXMART
₹5.5 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Portable fire extinguishers 4.5 kg | SEEMEX -FIRE EXTINGUISHERS | - | 98 NOS | ₹5,591 | 547,918 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 98 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure Extinguishing Media Carbon Dioxide Based Carbon Dioxide Based Expellant Medium CO2 Extinguishing Medium CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) NA 1 | - | - | - |
| 2 | - | - | - |
| NA Carbon Dioxide Based Fire Extinguisher Capacity (Kg) 4.5 4.5 Water Based Fire Extinguisher NA 2 | - | - | - |
| NA 1/4 Capacity Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 16.7 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire false - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -30° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 NA - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) Test Pressure - 143 Bar Burst Pressure - 250 Bar - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 50.35 Fire Rating for Class -A Fire Extinguisher NA - Fire Rating for Class -B Fire Extinguisher 13B - Certification BIS Marking Yes - CM/L No.* with Validity Period 8886112 with validity of 31/03/2018 - Availability of Test YES - 2/4 Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification Test Report No. a) 110038A | - | - | - |
| squeeze grip type | - | - | - |
| ISI marked | - | - | - |
| EN PED approved and CE marked | - | - | - |
| Tamper- proof plastic safety seal and a metal pin | - | - | - |
| Used/Unused readiness Indicator | - | - | - |
| valve housing covered with a cap made of ABS plastic. - Test Report Date a) 12/12/2011 - Name of the Lab a) Fire Test & Research Laboratory - Address of the Lab a) 9th Milestone | - | - | - |
| SH-11 | - | - | - |
| Sonipath- Gohana Road | - | - | - |
| Rattangarh | - | - | - |
| Sonipat-131001 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhay Bhan 226001 | - | - | - |
| Fire Service hqrs 4th & 5th floor Indira Bhawan Ashok Marg Lucknow 98 30 EMD Required No ePBG Required No | - | - | - |
Exempted
17 Oct 2018
21 Jun 2018
contract_GEMC-511687752197105.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_236632.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .