| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.3 CrAccepted-AOC 11 164 S BHAVAN VADAKUVILAI KUTTAIKADU KATTATHURAI POST KANNIYAKUMARI DISTRICT | KANNIYAKUMARI | TAMIL NADU | 629001 | ₹84.3 Cr Quoted ₹91.7 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹95.2 CrRejected-AOC 11 125 JOSEPH PRABHU ILLAM POOVAN PATTU VILLAI KUTTAIKADU VEEYANUR POST KANYAKUMARI DISTRICT 629702 | KANYAKUMARI | KANYAKUMARI | TAMIL NADU | 629702 | ₹95.2 Cr | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | JEBAMANI DHAS L2 | ABBS INFRASTRUCTURE PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00Supply earmarked quantity of water noted against 25 Nos. CWSS in Tirunelveli District by carrying out all the necessary works such as pumping, attending to leak and burst, attending to electrical and mechanical repair works, providing disinfection, preventive maintenance of all installations, sump cleaning and deliverance of earmarked quantity of water to the beneficiaries as per schedule and standard operating procedures and as directed by the TWAD Board officers for the period from 01.04.2026 to 31.03.2029 | |||||
| 1.01 | Operation and Maintenance of the CWSS to 170 habitations in Manur and Palayamkottai union in Tirunelveli District with river Tamirbarani as source | 1 | job | 4,86,59,399.46 ₹4.9 Cr | 4,68,89,953.09 ₹4.7 Cr |
| 1.02 | Operation and Maintenance of the CWSS to Nanguneri - Thisayanvilai Town Panchayats and 297 Rural Habitations in Tirunelveli District with river Tamirbarani as source | 1 | job | 13,13,96,466.79 ₹13.1 Cr | 12,66,18,383.9 ₹12.7 Cr |
| 1.03 | Operation and Maintenance of the CWSS to Senthamangalam and 57 Wayside Habitations in Tirunelveli District. with river Tamirbarani as source | 1 | job | 3,62,14,604.88 ₹3.6 Cr | 3,48,97,695.97 ₹3.5 Cr |
| 1.04 | Operation and Maintenance of the CWSS to Narasinganallur in Tirunelveli District with river Tamirbarani as source | 1 | job | 55,99,272.29 ₹56.0 L | 53,95,655.63 ₹54.0 L |
| 1.05 | Operation and Maintenance of the CWSS to 483 Rural habitations in Manur and 7 other Panchayat Unions, Sankarankovilmunicipality, Thiruvengadamr T.P, Sivakasi Corporation in Tirunelveli, Tenkasi and Virudhunagar District. with river Tamirbarani as source | 1 | job | 20,08,48,565.45 ₹20.1 Cr | 19,35,44,797.95 ₹19.4 Cr |
| 1.06 | Operation and Maintenance of the CWSS to Sankarankovil Municipality. Alangulam rtp and 60 Way Side Habitations with river Tamirbarani as source | 1 | job | 5,67,57,215.21 ₹5.7 Cr | 5,46,93,273.5 ₹5.5 Cr |
| 1.07 | Operation and Maintenance of the CWSS to Vagaikulam and 12 other rural habitations in Ambasamudram union of Tirunelveli District with river Tamirbarani as source | 1 | job | 89,04,714.16 ₹89.0 L | 85,80,903.06 ₹85.8 L |
| 1.08 | Operation and Maintenance of the CWSS to 185 rural habitations inTirunelveli Districtwith river Tamirbarani as source | 1 | job | 4,34,51,418.87 ₹4.3 Cr | 4,18,71,340.38 ₹4.2 Cr |
| 1.09 | Operation and Maintenance of the CWSS to Koodankulam and 12 other Village Panchayats of Radhapuram and Valliyur union in Tirunelveli District with river Tamirbarani as source | 1 | job | 3,62,88,088.14 ₹3.6 Cr | 3,49,68,516 ₹3.5 Cr |
Updated dates
Tender Value
₹86.5 Cr
EMD Value
₹64.9 L
Closing Date
19 Jan 2026, 3:00 pmClosed
Chief Engineer, TWAD, MDU
Office of the Chief Engineer, TWAD Board, Opposite to Mattuthavani Bus Stand, Madurai
Operation and Maintenance of 25 nos CWSS in Tirunelveli District
2026_TWAD_638233_1
Operation and Maintenance of 25 nos CWSS in Tirunelveli District
Open Tender
Civil Works - Water Works
1096 days
Tirunelveli
AS per Bid Document
2 documents required · 2 mandatory
₹0
₹64.9 L
Madurai
18 Mar 2026
2 Jan 2026
20 Jan 2026
2 Jan 2026
19 Jan 2026
9 Jan 2026
2 Jan 2026 - 7 Jan 2026
7 Jan 2026
Supply earmarked quantity of water noted against 25 Nos. CWSS in Tirunelveli District by carrying out all the necessary works such as pumping, attending to leak and burst, attending to electrical and mechanical repair works, providing disinfection, preventive maintenance of all installations, sump cleaning and deliverance of earmarked quantity of water to the beneficiaries as per schedule and standard operating procedures and as directed by the TWAD Board officers for the period from 01.04.2026 to 31.03.2029
Operation and Maintenance of the CWSS to 170 habitations in Manur and Palayamkottai union in Tirunelveli District with river Tamirbarani as source
Operation and Maintenance of the CWSS to Nanguneri - Thisayanvilai Town Panchayats and 297 Rural Habitations in Tirunelveli District with river Tamirbarani as source
Operation and Maintenance of the CWSS to Senthamangalam and 57 Wayside Habitations in Tirunelveli District. with river Tamirbarani as source
Operation and Maintenance of the CWSS to Narasinganallur in Tirunelveli District with river Tamirbarani as source
Operation and Maintenance of the CWSS to 483 Rural habitations in Manur and 7 other Panchayat Unions, Sankarankovilmunicipality, Thiruvengadamr T.P, Sivakasi Corporation in Tirunelveli, Tenkasi and Virudhunagar District. with river Tamirbarani as source
Operation and Maintenance of the CWSS to Sankarankovil Municipality. Alangulam rtp and 60 Way Side Habitations with river Tamirbarani as source
Operation and Maintenance of the CWSS to Vagaikulam and 12 other rural habitations in Ambasamudram union of Tirunelveli District with river Tamirbarani as source
Operation and Maintenance of the CWSS to 185 rural habitations inTirunelveli Districtwith river Tamirbarani as source
Operation and Maintenance of the CWSS to Koodankulam and 12 other Village Panchayats of Radhapuram and Valliyur union in Tirunelveli District with river Tamirbarani as source
Operation and Maintenance of the CWSS to Tsunami Affected 113 habitations in Tirunelveli District with river Tamirbarani as source
Operation and Maintenance of the CWSS to 25 Habitations in Pappakudi Union and 6 Habitations in Alangulam Union in Tirunelveli District.
Operation and Maintenance of the CWSS to Pappakudi and 17 Habitations in Tirunelveli District.
Operation and Maintenance of the CWSS Kavalkinaru - Vadakkankulam CWSS in Tirunelveli District
Operation and Maintenance of the WSS to Tirunelveli Medical College,Hostel and Hospital inTirunelveli District
Operation and Maintenance of the WSS to Central Prison in Tirunelveli District
Operation and Maintenance of the CWSS TO MOOLAKARAIPATTI in Tirunelveli DISTRICT.
Operation and Maintenance of the CWSS TO 34 RURAL HABITATIONS IN Manur Union of TIRUNELVELI DISTRICT.
Operation and Maintenance of the Skylark (P) WSS in Tirunelveli District.
Operation and Maintenance of the CWSS SANKARNAGAR THALAIYUTHU IN TIRUNELVELI DISTRICT
Operation and Maintenance of the CWSS Ponnakudi and 22 Rural habitations in Tirunelveli District.
Operation and Maintenance of the CWSS to BURKITMANAGAR in Tirunelveli District.
Operation and Maintenance of the CWSS to Reddiyarpatti and 63 Rural habitations in Tirunelveli District
Operation and Maintenance of the CWSS to Panagudi - Vadakku Valliyoor Town Panchayats and 168 Habitations in Tirunelveli District.
Operation and Maintenance of the CWSS TO BRAMMADESAM ,MANNARKOVIL, VAGAIKULAM HABITATIONS IN IN TIRUNELVELI DISTRICT
Operation and Maintenance of the CWSS TO BRAMMADESAM AND THREE OTHER VILLAGE PANCHAYATS COVERING 17 HABITATIONS IN AMBASAMUDRAM UNION OF TIRUNELVELI DISTRICT
Total Basic Value
Add GST @18% on Basic Value
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A1 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 5.21 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1901.65 ML (5.21*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
50 mm PVC 6 KSC PVC COUPLER FABRICATED
63mm PVC 4KSC PVC COUPLER FABRICATED
75mm PVC 4 KSC PVC COUPLER FABRICATED
90mm PVC 4KSC PVC COUPLER FABRICATED
110mm PVC 4KSC PVC COUPLER FABRICATED
140mm PVC 4KSC PVC COUPLER FABRICATED
160mm PVC 4KSC PVC COUPLER FABRICATED
200mm PVC 4KSC PVC COUPLER FABRICATED
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
For DI Pipe various size
Removing the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (ex
300mm DI K7 Pipe
250mm DI K7 Pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
300mm DI K7 Pipe
250mm DI K7 Pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
300mm DI K7 Pipe
250mm DI K7 Pipe
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials)
300mm DI K7 Pipe
250mm DI K7 Pipe
For DI Pipe various size
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Repairing/ reconditioning of Sluice valve (for line valve/ for Scour valve) including all material, labour (Specify type of sluice valve and type of repair to be carried out)
50mm SLUICE valve
65mm SLUICE valve
80mm SLUICE valve
80mm Scour valve
20mm Single chamber Air valve
40mm Double chamber Air valve
100mm Scour valve
150mm SLUICE valve
100mm SLUICE valve
200mm SLUICE valve
125mm Scour valve
50mm Gate valve
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 16Sq. mm aluminium cable
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
3core 16Sq. mm aluminium cable
Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers
3core 16Sq. mm aluminium cable
Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 25Sq. mm aluminium cable
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
3core 25Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 25Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
400 Amps 3 pole MCCB Switch
63 Amps 3 pole MCCB Switch
100 Amps 3 pole MCCB Switch
32 Amps 3 pole MCCB Switch
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
2 KVAR Power capacitors for 31 wayside sumps
For 7.5 HP Star delta
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) nclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board officers
For 5 HP DOL Starter
For 3 HP DOL Starter
For 2 HP DOL Starter
For 1 HP DOL Starter
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.70 LL capacity of sump @ Melakallur
0.60 LL capacity of sump @ Melakallur
0.65 LL capacity of sump @ sankanthiradu
2.35LL capacity of sump @ Kodaganallur
0.65LL capacity of sump @ Pazhavoor
1.00LL capacity of sump @ Kondanagaram
4.80 LL capacity of sump @ Suthamalli
1.65LL capacity of sump @ Narasinganallur
1.50LL capacity of sump @ Pettai Rural
0.40LL capacity of sump @ Thenpathu
0.55LL capacity of sump @ Vellalankulam
0.25LL capacity of sump @ Thulukarkulam
0.65LL capacity of sump @ Thirupanikarisalkulam
2.50LL capacity of sump @ Seethaparapanallur
0.60LL capacity of sump @ Pudhur
0.30LL capacity of sump @ Vallavankottai
0.70LL capacity of sump @ Madhavakuruchi
1.95LL capacity of sump @ Ramayanpatti
0.30LL capacity of sump @ Nanjankulam
0.85LL capacity of sump @ Thenkalam
1.75LL capacity of sump @ Thalaiyuthu
0.40LL capacity of sump @ Mavadi
0.70LL capacity of sump @ Manur
0.45LL capacity of sump @ Ettankulam
0.60LL capacity of sump @ Kalakudi
0.85LL capacity of sump @ Therkupatti
0.95LL capacity of sump @ Pallikottai
0.60LL capacity of sump @ Kanarpatti
0.75LL capacity of sump @ Pillayarkulam
1.00LL capacity of sump @ Alagiyapandipuram
1.25LL capacity of sump @ Vagaikulam
2.50LL capacity of sump @ Ukkirankottai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 5.262 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1925.892 ML (5.262*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
50 mm PVC 6 KSC PVC COUPLER FABRICATED
63mm PVC 4KSC PVC COUPLER FABRICATED
75mm PVC 4 KSC PVC COUPLER FABRICATED
90mm PVC 4KSC PVC COUPLER FABRICATED
110mm PVC 4KSC PVC COUPLER FABRICATED
140mm PVC 4KSC PVC COUPLER FABRICATED
160mm PVC 4KSC PVC COUPLER FABRICATED
200mm PVC 4KSC PVC COUPLER FABRICATED
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
For DI Pipe various size
Removing the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (ex
300mm DI K7 Pipe
250mm DI K7 Pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
300mm DI K7 Pipe
250mm DI K7 Pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
300mm DI K7 Pipe
250mm DI K7 Pipe
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials)
300mm DI K7 Pipe
250mm DI K7 Pipe
For DI Pipe various size
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Repairing/ reconditioning of Sluice valve (for line valve/ for Scour valve) including all material, labour (Specify type of sluice valve and type of repair to be carried out)
50mm SLUICE valve
65mm SLUICE valve
80mm SLUICE valve
80mm Scour valve
20mm Single chamber Air valve
40mm Double chamber Air valve
100mm Scour valve
150mm SLUICE valve
100mm SLUICE valve
200mm SLUICE valve
125mm Scour valve
50mm Gate valve
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 16Sq. mm aluminium cable
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
3core 16Sq. mm aluminium cable
Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers
3core 16Sq. mm aluminium cable
Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 25Sq. mm aluminium cable
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
3core 25Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 25Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
400 Amps 3 pole MCCB Switch
63 Amps 3 pole MCCB Switch
100 Amps 3 pole MCCB Switch
32 Amps 3 pole MCCB Switch
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
2 KVAR Power capacitors for 31 wayside sumps
For 7.5 HP Star delta
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) nclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board officers
For 5 HP DOL Starter
For 3 HP DOL Starter
For 2 HP DOL Starter
For 1 HP DOL Starter
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.70 LL capacity of sump @ Melakallur
0.60 LL capacity of sump @ Melakallur
0.65 LL capacity of sump @ sankanthiradu
2.35LL capacity of sump @ Kodaganallur
0.65LL capacity of sump @ Pazhavoor
1.00LL capacity of sump @ Kondanagaram
4.80 LL capacity of sump @ Suthamalli
1.65LL capacity of sump @ Narasinganallur
1.50LL capacity of sump @ Pettai Rural
0.40LL capacity of sump @ Thenpathu
0.55LL capacity of sump @ Vellalankulam
0.25LL capacity of sump @ Thulukarkulam
0.65LL capacity of sump @ Thirupanikarisalkulam
2.50LL capacity of sump @ Seethaparapanallur
0.60LL capacity of sump @ Pudhur
0.30LL capacity of sump @ Vallavankottai
0.70LL capacity of sump @ Madhavakuruchi
1.95LL capacity of sump @ Ramayanpatti
0.30LL capacity of sump @ Nanjankulam
0.85LL capacity of sump @ Thenkalam
1.75LL capacity of sump @ Thalaiyuthu
0.40LL capacity of sump @ Mavadi
0.70LL capacity of sump @ Manur
0.45LL capacity of sump @ Ettankulam
0.60LL capacity of sump @ Kalakudi
0.85LL capacity of sump @ Therkupatti
0.95LL capacity of sump @ Pallikottai
0.60LL capacity of sump @ Kanarpatti
0.75LL capacity of sump @ Pillayarkulam
1.00LL capacity of sump @ Alagiyapandipuram
1.25LL capacity of sump @ Vagaikulam
2.50LL capacity of sump @ Ukkirankottai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 5.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1941.80 ML (5.32*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
50 mm PVC 6 KSC PVC COUPLER FABRICATED
63mm PVC 4KSC PVC COUPLER FABRICATED
75mm PVC 4 KSC PVC COUPLER FABRICATED
90mm PVC 4KSC PVC COUPLER FABRICATED
110mm PVC 4KSC PVC COUPLER FABRICATED
140mm PVC 4KSC PVC COUPLER FABRICATED
160mm PVC 4KSC PVC COUPLER FABRICATED
200mm PVC 4KSC PVC COUPLER FABRICATED
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
For DI Pipe various size
Removing the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (ex
300mm DI K7 Pipe
250mm DI K7 Pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
300mm DI K7 Pipe
250mm DI K7 Pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
300mm DI K7 Pipe
250mm DI K7 Pipe
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials)
300mm DI K7 Pipe
250mm DI K7 Pipe
For DI Pipe various size
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Repairing/ reconditioning of Sluice valve (for line valve/ for Scour valve) including all material, labour (Specify type of sluice valve and type of repair to be carried out)
50mm SLUICE valve
65mm SLUICE valve
80mm SLUICE valve
80mm Scour valve
20mm Single chamber Air valve
40mm Double chamber Air valve
100mm Scour valve
150mm SLUICE valve
100mm SLUICE valve
200mm SLUICE valve
125mm Scour valve
50mm Gate valve
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 16Sq. mm aluminium cable
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
3core 16Sq. mm aluminium cable
Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers
3core 16Sq. mm aluminium cable
Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 25Sq. mm aluminium cable
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
3core 25Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 25Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
400 Amps 3 pole MCCB Switch
63 Amps 3 pole MCCB Switch
100 Amps 3 pole MCCB Switch
32 Amps 3 pole MCCB Switch
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
2 KVAR Power capacitors for 31 wayside sumps
For 7.5 HP Star delta
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) nclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board officers
For 5 HP DOL Starter
For 3 HP DOL Starter
For 2 HP DOL Starter
For 1 HP DOL Starter
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.70 LL capacity of sump @ Melakallur
0.60 LL capacity of sump @ Melakallur
0.65 LL capacity of sump @ sankanthiradu
2.35LL capacity of sump @ Kodaganallur
0.65LL capacity of sump @ Pazhavoor
1.00LL capacity of sump @ Kondanagaram
4.80 LL capacity of sump @ Suthamalli
1.65LL capacity of sump @ Narasinganallur
1.50LL capacity of sump @ Pettai Rural
0.40LL capacity of sump @ Thenpathu
0.55LL capacity of sump @ Vellalankulam
0.25LL capacity of sump @ Thulukarkulam
0.65LL capacity of sump @ Thirupanikarisalkulam
2.50LL capacity of sump @ Seethaparapanallur
0.60LL capacity of sump @ Pudhur
0.30LL capacity of sump @ Vallavankottai
0.70LL capacity of sump @ Madhavakuruchi
1.95LL capacity of sump @ Ramayanpatti
0.30LL capacity of sump @ Nanjankulam
0.85LL capacity of sump @ Thenkalam
1.75LL capacity of sump @ Thalaiyuthu
0.40LL capacity of sump @ Mavadi
0.70LL capacity of sump @ Manur
0.45LL capacity of sump @ Ettankulam
0.60LL capacity of sump @ Kalakudi
0.85LL capacity of sump @ Therkupatti
0.95LL capacity of sump @ Pallikottai
0.60LL capacity of sump @ Kanarpatti
0.75LL capacity of sump @ Pillayarkulam
1.00LL capacity of sump @ Alagiyapandipuram
1.25LL capacity of sump @ Vagaikulam
2.50LL capacity of sump @ Ukkirankottai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A2 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 10.62 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 3876.30 ML (10.62*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for AC and PSC Collar leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. (AC and PSC pipe Collar Leak )
AC Pipe - 441.393 cum PSC Pipe - 1012.844 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
AC pipe - 585 kg PSC pipe - 1000 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -585.00 litre PSC pipe - 875.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 1105.00 Kg PSC pipe - 1290.00 kg
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 845 hrs PSC pipe - 875.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC Pipe - 441.393 cum PSC Pipe - 1012.844 cum
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. AC & PSC Leak rectification with MS clampset
AC pipe - 281.979 cum PSC pipe - 188.054 cum
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board Officers
400 mm dia AC Class 15 Pipe
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
150 mm dia AC Class 15 Pipe
For 500 NB PSC of various classes Pipe
For 400 NB PSC of various classes Pipe
For 350 NB PSC of various classes Pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 617 hrs PSC pipe - 238 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC pipe -281.979 cum PSC Pipe - 188.054 cum
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. -PVC, AC and PSC burst
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC pipe - 1048.922 cum AC pipe - 238.923 cum PSC pipe - 745.079 cum
Removing the burst P.V.C/AC/PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
200mm PVC 4 KSC
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
For 350 mm PSC Pipes of various classes
For 400 mm PSC Pipes of various classes
For 500 mm PSC Pipes of various classes
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC Pipe
63mm PVC 4KSC Pipe
75mm PVC 4KSC Pipe
90mm PVC 4 KSC Pipe
110mm PVC 4KSC Pipe
140mm PVC 4KSC Pipe
160 mm PVC 4KSC Pipe
200 mm PVC 4KSC Pipe
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
150 mm DI K7 Class
200 mm DI K7 Class
250mm DI K7 Class
300 mm DI K7 Class
400 mm DI K7 Class
Supply and Delivery of MJ Collars as directed by TWAD Board officers
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
355.6 mm x 5.6 mm thick MS PIPE
406.4 mm x 6.3 mm thick MS PIPE
508 mm x 6.3 mm thick PIPE
Supply and Delivery of MJ Collars as directed by TWAD Board officers
350 mm dia PSC Pipe Various Classes
400 mm dia PSC Pipe Various Classes
500 mm dia PSC Pipe Various Classes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump
Rewinding of motor and and repair works to vertical turbine Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
Supply and delivery of Directly operated Bimetallic Thermal overload relay Upto which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) nclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board officers
5 HP Starter
3 HP Starter
2 HP Starter
7.5 HP Starter
12.5 HP Starter
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. etc., complete and as directed by TWAD Board officers.
60 HP Starter
40 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
Supply and delivery of following Range AMPS 4 Pole MCCB Switch ( Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
400 Amps MCCB
250-320 Amps MCCB
100 Amps MCCB
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI Sluice valve
350 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
250 mm CI Sluice valve
100mm Double air valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
Pathamadai (Headworks)2.50 LL
Pathamadai (Headworks)4.00 LL
Singikulam2.50 LL
Singikulam5.00 LL
SouthVijayanarayanam1.00 LL
SouthVijayanarayanam1.00 LL
Thisayanvilai0.50 LL
Thisayanvilai0.60LL
Marukalkurichi0.10LL
Nanguneri0.15LL
Nanguneri2.00 LL
PerumalNagar0.10 LL
PerumalNagar1.00 LL
Mavadi1.50 LL
Mavadi0.60LL
Radhapuram1.00 LL
Radhapuram4.00 LL
Vadakkankulam0.50LL
Vadakkankulam3.00LL
Samugarengapuram2.00LL
Samugarengapuram0.10LL
Shanmugapuram0.10LL
Alaganeri1.00 LL
Avaraikulam0.15LL
Avaraikulam0.60LL
Chidambarapuram0.60LL
Ittamohi0.10 LL
Ittamohi1.00 LL
Patrakattivilai0.10 LL
Pettaikulam0.10LL
Pettaikulam0.60LL
Rajivgandhinagar0.60LL
Manimutharkulam0.10LL
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD board officers
Formation of leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m to 10m
TRANSFORMER REPAIR AND RECONDITIONING- 200KVA U1 & U2 Transformer - HW Pathamadai
Labour charges for dismantling of 200 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as rected by TWAD Board Officers
Supply and delivery of 3 phase insulation to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of new transformer oil to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 11KV HV Bushing with metal parts to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 433KV LV Bushing copper rod to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of silica gel breather to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of gasket & oil seals to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of paint to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for hot air chamber treatment for IR value Improvement work 900c for 2 days to 200 KVA Transformer as per IS Specifications as directed by TwAD Board Officers
Charges for transformer tank cleaning and painting work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour charges for Re rection of 200 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
Hire charges for Mobile crane used for unloading of Transformer from Bed to loading into Vehicle for moving to Work Shop & After Repair work, Placing back in Transformer Bed
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 10.62 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 3886.92 ML (10.62*366)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for AC and PSC Collar leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. (AC and PSC pipe Collar Leak )
AC Pipe - 441.393 cum PSC Pipe - 1012.844 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
AC pipe - 585 kg PSC pipe - 1000 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -585.00 litre PSC pipe - 875.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 1105.00 Kg PSC pipe - 1290.00 kg
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 845 hrs PSC pipe - 875.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC Pipe - 441.393 cum PSC Pipe - 1012.844 cum
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. AC & PSC Leak rectification with MS clampset
AC pipe - 281.979 cum PSC pipe - 188.054 cum
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board Officers
400 mm dia AC Class 15 Pipe
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
150 mm dia AC Class 15 Pipe
For 500 NB PSC of various classes Pipe
For 400 NB PSC of various classes Pipe
For 350 NB PSC of various classes Pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 617 hrs PSC pipe - 238 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC pipe -281.979 cum PSC Pipe - 188.054 cum
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. -PVC, AC and PSC burst
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC pipe - 1048.922 cum AC pipe - 238.923 cum PSC pipe - 745.079 cum
Removing the burst P.V.C/AC/PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
200mm PVC 4 KSC
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
For 350 mm PSC Pipes of various classes
For 400 mm PSC Pipes of various classes
For 500 mm PSC Pipes of various classes
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC Pipe
63mm PVC 4KSC Pipe
75mm PVC 4KSC Pipe
90mm PVC 4 KSC Pipe
110mm PVC 4KSC Pipe
140mm PVC 4KSC Pipe
160 mm PVC 4KSC Pipe
200 mm PVC 4KSC Pipe
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
150 mm DI K7 Class
200 mm DI K7 Class
250mm DI K7 Class
300 mm DI K7 Class
400 mm DI K7 Class
Supply and Delivery of MJ Collars as directed by TWAD Board officers
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
355.6 mm x 5.6 mm thick MS PIPE
406.4 mm x 6.3 mm thick MS PIPE
508 mm x 6.3 mm thick PIPE
Supply and Delivery of MJ Collars as directed by TWAD Board officers
350 mm dia PSC Pipe Various Classes
400 mm dia PSC Pipe Various Classes
500 mm dia PSC Pipe Various Classes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump
Rewinding of motor and and repair works to vertical turbine Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
Supply and delivery of Directly operated Bimetallic Thermal overload relay Upto which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) nclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board officers
5 HP Starter
3 HP Starter
2 HP Starter
7.5 HP Starter
12.5 HP Starter
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. etc., complete and as directed by TWAD Board officers.
60 HP Starter
40 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
Supply and delivery of following Range AMPS 4 Pole MCCB Switch ( Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
400 Amps MCCB
250-320 Amps MCCB
100 Amps MCCB
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI Sluice valve
350 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
250 mm CI Sluice valve
100mm Double air valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
Pathamadai (Headworks)2.50 LL
Pathamadai (Headworks)4.00 LL
Singikulam2.50 LL
Singikulam5.00 LL
SouthVijayanarayanam1.00 LL
SouthVijayanarayanam1.00 LL
Thisayanvilai0.50 LL
Thisayanvilai0.60LL
Marukalkurichi0.10LL
Nanguneri0.15LL
Nanguneri2.00 LL
PerumalNagar0.10 LL
PerumalNagar1.00 LL
Mavadi1.50 LL
Mavadi0.60LL
Radhapuram1.00 LL
Radhapuram4.00 LL
Vadakkankulam0.50LL
Vadakkankulam3.00LL
Samugarengapuram2.00LL
Samugarengapuram0.10LL
Shanmugapuram0.10LL
Alaganeri1.00 LL
Avaraikulam0.15LL
Avaraikulam0.60LL
Chidambarapuram0.60LL
Ittamohi0.10 LL
Ittamohi1.00 LL
Patrakattivilai0.10 LL
Pettaikulam0.10LL
Pettaikulam0.60LL
Rajivgandhinagar0.60LL
Manimutharkulam0.10LL
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD board officers
Formation of leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m to 10m
TRANSFORMER REPAIR AND RECONDITIONING- 200KVA U1 & U2 Transformer - HW Pathamadai
Labour charges for dismantling of 200 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as rected by TWAD Board Officers
Supply and delivery of 3 phase insulation to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of new transformer oil to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 11KV HV Bushing with metal parts to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 433KV LV Bushing copper rod to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of silica gel breather to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of gasket & oil seals to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of paint to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for hot air chamber treatment for IR value Improvement work 900c for 2 days to 200 KVA Transformer as per IS Specifications as directed by TwAD Board Officers
Charges for transformer tank cleaning and painting work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour charges for Re rection of 200 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
Hire charges for Mobile crane used for unloading of Transformer from Bed to loading into Vehicle for moving to Work Shop & After Repair work, Placing back in Transformer Bed
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 10.62 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 3876.30 ML (10.62*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for AC and PSC Collar leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. (AC and PSC pipe Collar Leak )
AC Pipe - 441.393 cum PSC Pipe - 1012.844 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
AC pipe - 585 kg PSC pipe - 1000 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -585.00 litre PSC pipe - 875.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 1105.00 Kg PSC pipe - 1290.00 kg
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 845 hrs PSC pipe - 875.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC Pipe - 441.393 cum PSC Pipe - 1012.844 cum
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. AC & PSC Leak rectification with MS clampset
AC pipe - 281.979 cum PSC pipe - 188.054 cum
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board Officers
400 mm dia AC Class 15 Pipe
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
150 mm dia AC Class 15 Pipe
For 500 NB PSC of various classes Pipe
For 400 NB PSC of various classes Pipe
For 350 NB PSC of various classes Pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 617 hrs PSC pipe - 238 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC pipe -281.979 cum PSC Pipe - 188.054 cum
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. -PVC, AC and PSC burst
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC pipe - 1048.922 cum AC pipe - 238.923 cum PSC pipe - 745.079 cum
Removing the burst P.V.C/AC/PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
200mm PVC 4 KSC
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
For 350 mm PSC Pipes of various classes
For 400 mm PSC Pipes of various classes
For 500 mm PSC Pipes of various classes
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC Pipe
63mm PVC 4KSC Pipe
75mm PVC 4KSC Pipe
90mm PVC 4 KSC Pipe
110mm PVC 4KSC Pipe
140mm PVC 4KSC Pipe
160 mm PVC 4KSC Pipe
200 mm PVC 4KSC Pipe
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
150 mm DI K7 Class
200 mm DI K7 Class
250mm DI K7 Class
300 mm DI K7 Class
400 mm DI K7 Class
Supply and Delivery of MJ Collars as directed by TWAD Board officers
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
355.6 mm x 5.6 mm thick MS PIPE
406.4 mm x 6.3 mm thick MS PIPE
508 mm x 6.3 mm thick PIPE
Supply and Delivery of MJ Collars as directed by TWAD Board officers
350 mm dia PSC Pipe Various Classes
400 mm dia PSC Pipe Various Classes
500 mm dia PSC Pipe Various Classes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump
Rewinding of motor and and repair works to vertical turbine Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
Supply and delivery of Directly operated Bimetallic Thermal overload relay Upto which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) nclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board officers
5 HP Starter
3 HP Starter
2 HP Starter
7.5 HP Starter
12.5 HP Starter
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. etc., complete and as directed by TWAD Board officers.
60 HP Starter
40 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work
Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
Supply and delivery of following Range AMPS 4 Pole MCCB Switch ( Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
400 Amps MCCB
250-320 Amps MCCB
100 Amps MCCB
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI Sluice valve
350 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
250 mm CI Sluice valve
100mm Double air valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
Pathamadai (Headworks)2.50 LL
Pathamadai (Headworks)4.00 LL
Singikulam2.50 LL
Singikulam5.00 LL
SouthVijayanarayanam1.00 LL
SouthVijayanarayanam1.00 LL
Thisayanvilai0.50 LL
Thisayanvilai0.60LL
Marukalkurichi0.10LL
Nanguneri0.15LL
Nanguneri2.00 LL
PerumalNagar0.10 LL
PerumalNagar1.00 LL
Mavadi1.50 LL
Mavadi0.60LL
Radhapuram1.00 LL
Radhapuram4.00 LL
Vadakkankulam0.50LL
Vadakkankulam3.00LL
Samugarengapuram2.00LL
Samugarengapuram0.10LL
Shanmugapuram0.10LL
Alaganeri1.00 LL
Avaraikulam0.15LL
Avaraikulam0.60LL
Chidambarapuram0.60LL
Ittamohi0.10 LL
Ittamohi1.00 LL
Patrakattivilai0.10 LL
Pettaikulam0.10LL
Pettaikulam0.60LL
Rajivgandhinagar0.60LL
Manimutharkulam0.10LL
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD board officers
Formation of leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m to 10m
TRANSFORMER REPAIR AND RECONDITIONING- 200KVA U1 & U2 Transformer - HW Pathamadai
Labour charges for dismantling of 200 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as rected by TWAD Board Officers
Supply and delivery of 3 phase insulation to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of new transformer oil to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 11KV HV Bushing with metal parts to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 433KV LV Bushing copper rod to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of silica gel breather to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of gasket & oil seals to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of paint to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for hot air chamber treatment for IR value Improvement work 900c for 2 days to 200 KVA Transformer as per IS Specifications as directed by TwAD Board Officers
Charges for transformer tank cleaning and painting work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour charges for Re rection of 200 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
Hire charges for Mobile crane used for unloading of Transformer from Bed to loading into Vehicle for moving to Work Shop & After Repair work, Placing back in Transformer Bed
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A3 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 3.02 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1102.30 ML (3.02*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for AC & PSC Collar leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
AC Pipe - 88.890 cum PSC pipe - 111.600 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
AC pipe - 237.00 Kg PSC pipe - 80 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 258 litres PSC pipe -60 litres
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -547.00 Kg PSC pipe - 140.00 Kg
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 310.00 hrs PSC pipe - 20.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC Pipe - 88.890 cum PSC pipe - 111.600 cum
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works with MS Clampset for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PSC Leak
PSC pipe
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board Officers
350 mm PSC pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
PSC pipe
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers. 355.6 X 5.6mm dia
Each - 3 metre i) Maruthampudur ii) Kandapatti iii) Ramnagar iv Uthumalai
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
PSC pipe
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.- PVC and AC pipes
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC pipes - 576.931 cum AC pipe - 160.874 cum
Removing the burst P.V.C/AC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC Pipe
63mm PVC 4KSC Pipe
75mm PVC 4KSC Pipe
90mm PVC 4 KSC Pipe
110mm PVC 4KSC Pipe
140mm PVC 4KSC Pipe
160 mm PVC 4KSC Pipe
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of A.C.Pressure Pipes inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
300 mm AC Class 15
250 mm AC Class 15
200 mm AC Class 15
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Rewinding of Motors in pumping stations iod in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by the TWAD Board Officers
Rewinding of motor and reconditioning pump and repair works to Submersible / Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump set
Rewinding of motor and and repair works to HSC Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. etc., complete and as directed by TWAD Board officers.
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ (± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)
CABLE FAULT
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 4 Pole & 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
4 Pole MCCB
400 Amps MCCB
63 Amps MCCB
250 Amps MCCB
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI NRV valve
200 mm CI Sluice valve
200 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI NRV valve
125 mm CI Sluice valve
125 mm CI NRV valve
100 mm CI Sluice valve
100 mm CI NRV valve
80mm CI Double air valve
50mm CI Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
0.60 LL Capacity of sump Nanthanthattai (Head works)
0.60 LL Capacity of sump Kandapatti
0.60 LL Capacity of sump Uthumalai
0.15 LL Capacity of sump Kalathimadam
0.10 LL Capacity of sump Karuvantha
0.30 LL Capacity of sump Soorangudi
0.05 LL Capacity of sump R.Navaneethakrishnapuram
0.15 LL Capacity of sump Veerasigamani
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board Officers
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 3.02 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1105.320 ML (3.02*366)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for AC & PSC Collar leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
AC Pipe - 88.890 cum PSC pipe - 111.600 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
AC pipe - 237.00 Kg PSC pipe - 80 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 258 litres PSC pipe -60 litres
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -547.00 Kg PSC pipe - 140.00 Kg
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 310.00 hrs PSC pipe - 20.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC Pipe - 88.890 cum PSC pipe - 111.600 cum
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works with MS Clampset for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PSC Leak
PSC pipe
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board Officers
350 mm PSC pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
PSC pipe
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers. 355.6 X 5.6mm dia
Each - 3 metre i) Maruthampudur ii) Kandapatti iii) Ramnagar iv Uthumalai
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
PSC pipe
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.- PVC and AC pipes
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC pipes - 576.931 cum AC pipe - 160.874 cum
Removing the burst P.V.C/AC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC Pipe
63mm PVC 4KSC Pipe
75mm PVC 4KSC Pipe
90mm PVC 4 KSC Pipe
110mm PVC 4KSC Pipe
140mm PVC 4KSC Pipe
160 mm PVC 4KSC Pipe
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of A.C.Pressure Pipes inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
300 mm AC Class 15
250 mm AC Class 15
200 mm AC Class 15
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Rewinding of Motors in pumping stations iod in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by the TWAD Board Officers
Rewinding of motor and reconditioning pump and repair works to Submersible / Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump set
Rewinding of motor and and repair works to HSC Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. etc., complete and as directed by TWAD Board officers.
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ (± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)
CABLE FAULT
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 4 Pole & 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
4 Pole MCCB
400 Amps MCCB
63 Amps MCCB
250 Amps MCCB
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI NRV valve
200 mm CI Sluice valve
200 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI NRV valve
125 mm CI Sluice valve
125 mm CI NRV valve
100 mm CI Sluice valve
100 mm CI NRV valve
80mm CI Double air valve
50mm CI Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
0.60 LL Capacity of sump Nanthanthattai (Head works)
0.60 LL Capacity of sump Kandapatti
0.60 LL Capacity of sump Uthumalai
0.15 LL Capacity of sump Kalathimadam
0.10 LL Capacity of sump Karuvantha
0.30 LL Capacity of sump Soorangudi
0.05 LL Capacity of sump R.Navaneethakrishnapuram
0.15 LL Capacity of sump Veerasigamani
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board Officers
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 3.02 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1102.30 ML (3.02*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for AC & PSC Collar leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
AC Pipe - 88.890 cum PSC pipe - 111.600 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
AC pipe - 237.00 Kg PSC pipe - 80 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 258 litres PSC pipe -60 litres
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -547.00 Kg PSC pipe - 140.00 Kg
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
AC pipe - 310.00 hrs PSC pipe - 20.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC Pipe - 88.890 cum PSC pipe - 111.600 cum
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works with MS Clampset for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PSC Leak
PSC pipe
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board Officers
350 mm PSC pipe
Dewatering using diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.- 5 HP
PSC pipe
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers. 355.6 X 5.6mm dia
Each - 3 metre i) Maruthampudur ii) Kandapatti iii) Ramnagar iv Uthumalai
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
PSC pipe
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.- PVC and AC pipes
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC pipes - 576.931 cum AC pipe - 160.874 cum
Removing the burst P.V.C/AC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC Pipe
63mm PVC 4KSC Pipe
75mm PVC 4KSC Pipe
90mm PVC 4 KSC Pipe
110mm PVC 4KSC Pipe
140mm PVC 4KSC Pipe
160 mm PVC 4KSC Pipe
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of A.C.Pressure Pipes inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
300 mm AC Class 15
250 mm AC Class 15
200 mm AC Class 15
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Rewinding of Motors in pumping stations iod in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by the TWAD Board Officers
Rewinding of motor and reconditioning pump and repair works to Submersible / Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump set
Rewinding of motor and and repair works to HSC Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc. etc., complete and as directed by TWAD Board officers.
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ (± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)
CABLE FAULT
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 4 Pole & 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
4 Pole MCCB
400 Amps MCCB
63 Amps MCCB
250 Amps MCCB
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI NRV valve
200 mm CI Sluice valve
200 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI NRV valve
125 mm CI Sluice valve
125 mm CI NRV valve
100 mm CI Sluice valve
100 mm CI NRV valve
80mm CI Double air valve
50mm CI Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
0.60 LL Capacity of sump Nanthanthattai (Head works)
0.60 LL Capacity of sump Kandapatti
0.60 LL Capacity of sump Uthumalai
0.15 LL Capacity of sump Kalathimadam
0.10 LL Capacity of sump Karuvantha
0.30 LL Capacity of sump Soorangudi
0.05 LL Capacity of sump R.Navaneethakrishnapuram
0.15 LL Capacity of sump Veerasigamani
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board Officers
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A4 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 116.80 ML (0.32*365)
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes - 119.837 cum GI pipe - 89.809 cum
Removing the burst P.V.C/GI pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
63 mm PVC 4 KSC
75 mm PVC 4 KSC
90 mm PVC 4 KSC
110 mm PVC 4 KSC
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Repair and Reconditonig works in various capacity 7.5 HP Openwell Submersible Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 3 HP Centrifugal monobloc Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 25 Amps 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
12 Amps 440V
25 Amps 440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to 10 A
Upto 10 A to 20 A
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by TWAD Board officers -7.5 HP
Attending cable fault by replacing the cable
Supply and delivery of PVC Insulated and sheathed 3 Core Flat Type Copper cable conforming to IS 694/1990 and as amended thereafter etc complete and as directed by TWAD board officers
3 core 10 Sq. mm copper cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable For laying below GL including earth work
3 core 10 Sq. mm copper cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply and delivery of following Range AMPS 100 Amps 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
65 mm CI NRV valve
80 mm CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.10 LL capacity of sump @ Gnanamalkattalai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m to 10m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 117.12 ML (0.32*366)
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes - 119.837 cum GI pipe - 89.809 cum
Removing the burst P.V.C/GI pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
63 mm PVC 4 KSC
75 mm PVC 4 KSC
90 mm PVC 4 KSC
110 mm PVC 4 KSC
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Repair and Reconditonig works in various capacity 7.5 HP Openwell Submersible Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 3 HP Centrifugal monobloc Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 25 Amps 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
12 Amps 440V
25 Amps 440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to 10 A
Upto 10 A to 20 A
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by TWAD Board officers -7.5 HP
Attending cable fault by replacing the cable
Supply and delivery of PVC Insulated and sheathed 3 Core Flat Type Copper cable conforming to IS 694/1990 and as amended thereafter etc complete and as directed by TWAD board officers
3 core 10 Sq. mm copper cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable For laying below GL including earth work
3 core 10 Sq. mm copper cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply and delivery of following Range AMPS 100 Amps 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
65 mm CI NRV valve
80 mm CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.10 LL capacity of sump @ Gnanamalkattalai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m to 10m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 116.80 ML (0.32*365)
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes - 119.837 cum GI pipe - 89.809 cum
Removing the burst P.V.C/GI pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
63 mm PVC 4 KSC
75 mm PVC 4 KSC
90 mm PVC 4 KSC
110 mm PVC 4 KSC
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm GI (Medium)
80mm GI (Medium)
100mm GI (Medium)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Repair and Reconditonig works in various capacity 7.5 HP Openwell Submersible Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 3 HP Centrifugal monobloc Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 25 Amps 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
12 Amps 440V
25 Amps 440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to 10 A
Upto 10 A to 20 A
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by TWAD Board officers -7.5 HP
Attending cable fault by replacing the cable
Supply and delivery of PVC Insulated and sheathed 3 Core Flat Type Copper cable conforming to IS 694/1990 and as amended thereafter etc complete and as directed by TWAD board officers
3 core 10 Sq. mm copper cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable For laying below GL including earth work
3 core 10 Sq. mm copper cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply and delivery of following Range AMPS 100 Amps 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
65 mm CI NRV valve
80 mm CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.10 LL capacity of sump @ Gnanamalkattalai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m to 10m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A5 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 27.82MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 10154.30 ML (27.82*365 )
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes -4272.549 cum AC Pipes - 495.249 cum
Removing the burst P.V.C./A.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
300 mm dia A.C. Pipes
250 mm dia A.C. Pipes
200 mm dia A.C. Pipes
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of AC pipes of 5 m length and specials confirming to IS other specifications amended from time to time having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc., complete and as directed by TWAD Board officers.
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Attending Collar Leaks in the Pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
AC Collar leak - 909.761 cum PSC Collar Leak - 2905.247 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 714.00 Kg PSC Pipe -2425.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -952.00 litre PSC Pipe -2495.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -714.00 Kg PSC Pipe - 3715 kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
AC pipe -952.00 hrs PSC Pipe -3013.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC pipe - 909.761 cum PSC Pipe - 2905.247 cum
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) GI pipe - 86.63 Cum 2) OPVC and DI pipe -46.268 cum 3) PSC and AC pipe - 679.704 cum 4) MS pipes loacted PSC pipe line - 409.551 cum
Supply and delivery of the following sizes of GI medium pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Supply and delivery of following sizes of GI Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
25 mm Coupling
40 mm Coupling
50 mm Coupling
65 mm Coupling
80 mm Coupling
100mm Coupling
50 mm Flange set
65 mm Flange set
80 mm Flange set
100mm Flange set
50 mm Rubber sheet for Flange set
65 mm Rubber sheet for Flange set
80 mm Rubber sheet for Flange set
100mm Rubber sheet for Flange set
40 mm Hex nipple
50 mm Hex nipple
65 mm Hex nipple
80 mm Hex nipple
100mm Hex nipple
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63 mm x 20 mm
75 mm x 20 mm
90 mm x 20 mm
Supply, Delivery and fixing of CI SINGLE AIR VALVE AS PER ISI 14845/2000 AND WITH 5 YEARS WARRANT inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
Supply and delivery of the following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 AS PER IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200 mm dia DI K7
350 mm dia DI K7
Supply and delivery of the following sizes of UN PLASTICIZED O-PVC PIPES FOR POTABLE WATER SUPPLY AS PER IS 16647 / 2017 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
250 mm dia OPVC PN 12.5 Class 500
Supply and delivery of the following sizes of MOULDED (OR) FABRICATED O-PVC FITTINGS COMPATIBLE WITH O-PVC PIPES
SLIDING COUPLER DN 250mm
Supply and Delivery of MJ Collars as directed by TWAD Board officers IS 8794/1988 etc., complete and as directed by TWAD Board officers
200 mm dia DI K7
350 mm dia DI K7
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board officers
For 800mm PSC of various classes Pipe
For 500 NB PSC of various classes Pipe
For 450 NB PSC of various classes Pipe
For 350 NB PSC of various classes Pipe
For 300 NB AC of various classes Pipe
For 250 NB AC of various classes Pipe
For 200 NB AC of various classes Pipe
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
PSC and AC pipes - 628 hrs MS pipes located PSc pipelines - 407 hrs
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
PSC and AC pipe
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
PSC and AC pipe
Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
MS pipes located PSc pipelines
Hire charges for Generator for electric current for attending leaks by fabrication of MS pipes and specials including fuel, Transportation etc., Complete as directed by TWAD Officials
MS pipes located PSc pipelines
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
813 mm x 7.1 mm thick MS PIPE
355.6 mm x 5 mm thick MS PIPE
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) GI pipe - 86.63 Cum 2) OPVC and DI pipe -46.268 cum 3) PSC and AC pipe - 679.704 cum 4) MS pipes loacted PSC pipe line - 409.551 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump set
Rewinding of motor and and repair works to vertical turbine / HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Vertical turbine motor
HSC motor
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Attending Major Fault in Transformer
Labour Charges for dismantling of Transformer upto 500 KVA at Booster Stations with all accessories by using crane etc.complete as directed by TWAD Board officers
500 KVA TRANSFORMER LOCATED IN PAZHAVOOR HEADWORKS - 2 NOS (1 STANDBYE) & AZHAGIYAPANDIPURAM BOOSTER - 2 NOS (1 STANDBYE)
400KVA TRANSFORMER LOCATED IN SIRUKANKURICHI BOOSTER STATION - 2 NOS (1 STANDBYE)
250 KVA TRANSFORMER LOCATED IN NALUVASANKOTTAI BOOSTER STATION - 2 NOS (1 STANDBYE)
200 KVA TRANSFORMER LOCATED IN VADAKUACHAMPATTI BOOSTER STATION - 2 NOS (1 STANDBYE)
Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase Transformer upto 500KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to Transformer upto 500KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 3 phase insulation material for Transformer upto 500 KvA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of new transformer oil suitable for Transformers upto 500KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 11KV HV bushing with Metal parts for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 433V LV bushing copper rod to upto 500 KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of silica gel breather suitable for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of capillary type thermometer including accessories suitable for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delivery of Gasket & Oil Seals suitable for 500KvA & 400KvA as directed by TWAD Board Officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
Supply and delivery of Gasket & Oil Seals suitable for 250KvA & 200KvA as directed by TWAD Board Officers.
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of paint for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days for Transformer upto 500 KVA etc.,complete as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for Transformer tank cleaning and painting work for Transformer upto 500 KVA as per IS Specification as directed by TWAD Board Officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 200 & 250 KVA Transformer as per IS specifications as directed by TWAD board officers..
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVa & 500 KVA Transformer as per IS specifications as directed by TWAD board officers..
500 KVA TRANSFORMER
400KVA TRANSFORMER
Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 200 KvA & 250 KVA Transformer as per IS specifications as directed by TWAD board officers.
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 Kva & 500 KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
Labour Charges for Re erection of Tranformers upto 500 KVA and all accessories at Booster Station by using crane and fixing etc complete as directed by Twad Board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Hiring Charges for Crane for Positioning of Transformer in Bed for fixing etc., Complete as directed by TWAD Board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Conveyance charges for transformers unit from Booster Station to work shop site and for rectification works from work shop site to Booster Station after completion of rectification works etc complete as directed by Twad Board officers
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delivery of Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc ., complete and as directed by TWAD Board officers
9 Amps\440V
12 Amps\440V
18 Amps\440V
25 Amps\440V
32 Amps\440V
40 Amps\440V
45 Amps\440V
95 Amps\440V
185 Amps\440V
300 Amps\440V
400 Amps\440V
Supply and delivery of following Electromechanical item as directed by TWAD Board Officials
Digital Ammeter 3 phase
Digital Voltmeter 3 phase
SUPPLY AND DELIVERY OF PVC INSULATED SINGLE CORE MULTI STRAND FIRE RETARDANT LOW SMOKE (FRLS) FLEXIBLE COPPER CABLEWITH ISI MARK CONFORMING TO IS
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5A
Upto 5A-10A
Upto 10A-20A
Upto 20A-30A
Upto 30A-50A
Upto 50A-75A
Upto 75A-110A
Upto 200A-300A
Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
5 HP Starter
3 HP Starter
2 HP Starter
1.5 HP Starter
1.0 HP Starter
25 HP Starter
22.5 HP Starter
22 HP Starter
20 HP Starter
17.5 HP Starter
10 HP Starter
7.5 HP Starter
Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V (+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 4 Pole & 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
400 Amps MCCB
400 Amps Spreader Terminal
250 Amps MCCB
250 Amps Spreader Terminal
125 Amps MCCB
125 Amps Spreader Terminal
63 Amps MCCB
63 Amps Spreader Terminal
400 Amps MCCB
400 Amps Spreader Terminal
250 Amps MCCB
250 Amps Spreader Terminal
160 Amps MCCB
160 Amps Spreader Terminal
100 Amps MCCB
100 Amps Spreader Terminal
Supply and delivery of following Fuse unit etc., complete and as directed by TWAD Board officers
200 AMPS Porcelain Fuse unit
100 AMPS Porcelain Fuse unit
63 AMPS Porcelain Fuse unit
32 AMPS Porcelain Fuse unit
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI scour /CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI Sluice valve
350 mm CI NRV valve
300 mm CI Sluice valve
300 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
800 mm CI Sluice valve
700 mm CI Sluice valve
500 mm CI Sluice valve
450 mm CI Sluice valve
250 mm CI Sluice valve
150mm Double air valve
100mm Double air valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
15.00 LL 1) Pazhavoor(Headworks) 2) Sirukankuruchi 3) Madhavakuruchi 4) Alagiyapandiyapuram 5) Vadakku Achampatti 6) Naluvasankottai 7) Madhavakuruchi
1.50 LL Pazhavoor(Headworks) (Sump cum pumphouse)
0.10 LL 1) Vettuvankulam 2) Seethaparpanallur 3) Ayubhkanpuram 4) Vadakku Cheliyanallur 5) Therkku Achampatti 6) Devarkulam(Chettikuruchi) 7) Karisalkulam 8) Muthukrishnapuram
0.30 LL 1) Kankeyankulam 2) Rastha 3) Ettankulam 4) Melapilayarkulam 5) Therkku Puliyampatti 6) Vadanathampatti 7) Madathupatti 8) Panaiyur 9) Sump at Kunndampatti 10) Sump at Sarathanagar
0.60 LL 1) Manur 2) Chettikulam 3) Nakkalamuthampatti
1.00 LL Thalavaipuram
2.00 LL Thiruvengadam
3.00 LL Sankarankovil
5.00 LL 1) Booster at Thiruvenkatam 2) Booster at Seval patti 3) Booster at Keelanmarainadu 4) Booster at Sithurajapuram
1.00 LL MSR AT SAMABAKULAM
2.00 LL MSR Vadakku KuruviKulam
1.00 LL MSR @KalliKulam
4.00 LL MSR @ANAIYUR
2.00 LL MSR @Sankarankoil
2.00 LL MSR @Ettiseri
1.00 LL MSR @Vadakku-malaiyadipatti
0.60 LL MSR @ Kalingapatti
2.00 LL MSR @ Nakkalamuthanpatti
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 27.82MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 10182.12 ML (27.82*366 )
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes -4272.549 cum AC Pipes - 495.249 cum
Removing the burst P.V.C./A.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
300 mm dia A.C. Pipes
250 mm dia A.C. Pipes
200 mm dia A.C. Pipes
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of AC pipes of 5 m length and specials confirming to IS other specifications amended from time to time having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc., complete and as directed by TWAD Board officers.
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Attending Collar Leaks in the Pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
AC Collar leak - 909.761 cum PSC Collar Leak - 2905.247 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 714.00 Kg PSC Pipe -2425.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -952.00 litre PSC Pipe -2495.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -714.00 Kg PSC Pipe - 3715 kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
AC pipe -952.00 hrs PSC Pipe -3013.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC pipe - 909.761 cum PSC Pipe - 2905.247 cum
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) GI pipe - 86.63 Cum 2) OPVC and DI pipe -46.268 cum 3) PSC and AC pipe - 679.704 cum 4) MS pipes loacted PSC pipe line - 409.551 cum
Supply and delivery of the following sizes of GI medium pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Supply and delivery of following sizes of GI Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
25 mm Coupling
40 mm Coupling
50 mm Coupling
65 mm Coupling
80 mm Coupling
100mm Coupling
50 mm Flange set
65 mm Flange set
80 mm Flange set
100mm Flange set
50 mm Rubber sheet for Flange set
65 mm Rubber sheet for Flange set
80 mm Rubber sheet for Flange set
100mm Rubber sheet for Flange set
40 mm Hex nipple
50 mm Hex nipple
65 mm Hex nipple
80 mm Hex nipple
100mm Hex nipple
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63 mm x 20 mm
75 mm x 20 mm
90 mm x 20 mm
Supply, Delivery and fixing of CI SINGLE AIR VALVE AS PER ISI 14845/2000 AND WITH 5 YEARS WARRANT inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
Supply and delivery of the following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 AS PER IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200 mm dia DI K7
350 mm dia DI K7
Supply and delivery of the following sizes of UN PLASTICIZED O-PVC PIPES FOR POTABLE WATER SUPPLY AS PER IS 16647 / 2017 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
250 mm dia OPVC PN 12.5 Class 500
Supply and delivery of the following sizes of MOULDED (OR) FABRICATED O-PVC FITTINGS COMPATIBLE WITH O-PVC PIPES
SLIDING COUPLER DN 250mm
Supply and Delivery of MJ Collars as directed by TWAD Board officers IS 8794/1988 etc., complete and as directed by TWAD Board officers
200 mm dia DI K7
350 mm dia DI K7
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board officers
For 800mm PSC of various classes Pipe
For 500 NB PSC of various classes Pipe
For 450 NB PSC of various classes Pipe
For 350 NB PSC of various classes Pipe
For 300 NB AC of various classes Pipe
For 250 NB AC of various classes Pipe
For 200 NB AC of various classes Pipe
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
PSC and AC pipes - 628 hrs MS pipes located PSc pipelines - 407 hrs
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
PSC and AC pipe
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
PSC and AC pipe
Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
MS pipes located PSc pipelines
Hire charges for Generator for electric current for attending leaks by fabrication of MS pipes and specials including fuel, Transportation etc., Complete as directed by TWAD Officials
MS pipes located PSc pipelines
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
813 mm x 7.1 mm thick MS PIPE
355.6 mm x 5 mm thick MS PIPE
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) GI pipe - 86.63 Cum 2) OPVC and DI pipe -46.268 cum 3) PSC and AC pipe - 679.704 cum 4) MS pipes loacted PSC pipe line - 409.551 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump set
Rewinding of motor and and repair works to vertical turbine / HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Vertical turbine motor
HSC motor
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Attending Major Fault in Transformer
Labour Charges for dismantling of Transformer upto 500 KVA at Booster Stations with all accessories by using crane etc.complete as directed by TWAD Board officers
500 KVA TRANSFORMER LOCATED IN PAZHAVOOR HEADWORKS - 2 NOS (1 STANDBYE) & AZHAGIYAPANDIPURAM BOOSTER - 2 NOS (1 STANDBYE)
400KVA TRANSFORMER LOCATED IN SIRUKANKURICHI BOOSTER STATION - 2 NOS (1 STANDBYE)
250 KVA TRANSFORMER LOCATED IN NALUVASANKOTTAI BOOSTER STATION - 2 NOS (1 STANDBYE)
200 KVA TRANSFORMER LOCATED IN VADAKUACHAMPATTI BOOSTER STATION - 2 NOS (1 STANDBYE)
Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase Transformer upto 500KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to Transformer upto 500KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 3 phase insulation material for Transformer upto 500 KvA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of new transformer oil suitable for Transformers upto 500KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 11KV HV bushing with Metal parts for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 433V LV bushing copper rod to upto 500 KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of silica gel breather suitable for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of capillary type thermometer including accessories suitable for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delivery of Gasket & Oil Seals suitable for 500KvA & 400KvA as directed by TWAD Board Officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
Supply and delivery of Gasket & Oil Seals suitable for 250KvA & 200KvA as directed by TWAD Board Officers.
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of paint for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days for Transformer upto 500 KVA etc.,complete as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for Transformer tank cleaning and painting work for Transformer upto 500 KVA as per IS Specification as directed by TWAD Board Officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 200 & 250 KVA Transformer as per IS specifications as directed by TWAD board officers..
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVa & 500 KVA Transformer as per IS specifications as directed by TWAD board officers..
500 KVA TRANSFORMER
400KVA TRANSFORMER
Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 200 KvA & 250 KVA Transformer as per IS specifications as directed by TWAD board officers.
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 Kva & 500 KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
Labour Charges for Re erection of Tranformers upto 500 KVA and all accessories at Booster Station by using crane and fixing etc complete as directed by Twad Board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Hiring Charges for Crane for Positioning of Transformer in Bed for fixing etc., Complete as directed by TWAD Board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Conveyance charges for transformers unit from Booster Station to work shop site and for rectification works from work shop site to Booster Station after completion of rectification works etc complete as directed by Twad Board officers
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delivery of Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc ., complete and as directed by TWAD Board officers
9 Amps\440V
12 Amps\440V
18 Amps\440V
25 Amps\440V
32 Amps\440V
40 Amps\440V
45 Amps\440V
95 Amps\440V
185 Amps\440V
300 Amps\440V
400 Amps\440V
Supply and delivery of following Electromechanical item as directed by TWAD Board Officials
Digital Ammeter 3 phase
Digital Voltmeter 3 phase
SUPPLY AND DELIVERY OF PVC INSULATED SINGLE CORE MULTI STRAND FIRE RETARDANT LOW SMOKE (FRLS) FLEXIBLE COPPER CABLEWITH ISI MARK CONFORMING TO IS
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5A
Upto 5A-10A
Upto 10A-20A
Upto 20A-30A
Upto 30A-50A
Upto 50A-75A
Upto 75A-110A
Upto 200A-300A
Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
5 HP Starter
3 HP Starter
2 HP Starter
1.5 HP Starter
1.0 HP Starter
25 HP Starter
22.5 HP Starter
22 HP Starter
20 HP Starter
17.5 HP Starter
10 HP Starter
7.5 HP Starter
Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V (+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 4 Pole & 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
400 Amps MCCB
400 Amps Spreader Terminal
250 Amps MCCB
250 Amps Spreader Terminal
125 Amps MCCB
125 Amps Spreader Terminal
63 Amps MCCB
63 Amps Spreader Terminal
400 Amps MCCB
400 Amps Spreader Terminal
250 Amps MCCB
250 Amps Spreader Terminal
160 Amps MCCB
160 Amps Spreader Terminal
100 Amps MCCB
100 Amps Spreader Terminal
Supply and delivery of following Fuse unit etc., complete and as directed by TWAD Board officers
200 AMPS Porcelain Fuse unit
100 AMPS Porcelain Fuse unit
63 AMPS Porcelain Fuse unit
32 AMPS Porcelain Fuse unit
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI scour /CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI Sluice valve
350 mm CI NRV valve
300 mm CI Sluice valve
300 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
800 mm CI Sluice valve
700 mm CI Sluice valve
500 mm CI Sluice valve
450 mm CI Sluice valve
250 mm CI Sluice valve
150mm Double air valve
100mm Double air valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
15.00 LL 1) Pazhavoor(Headworks) 2) Sirukankuruchi 3) Madhavakuruchi 4) Alagiyapandiyapuram 5) Vadakku Achampatti 6) Naluvasankottai 7) Madhavakuruchi
1.50 LL Pazhavoor(Headworks) (Sump cum pumphouse)
0.10 LL 1) Vettuvankulam 2) Seethaparpanallur 3) Ayubhkanpuram 4) Vadakku Cheliyanallur 5) Therkku Achampatti 6) Devarkulam(Chettikuruchi) 7) Karisalkulam 8) Muthukrishnapuram
0.30 LL 1) Kankeyankulam 2) Rastha 3) Ettankulam 4) Melapilayarkulam 5) Therkku Puliyampatti 6) Vadanathampatti 7) Madathupatti 8) Panaiyur 9) Sump at Kunndampatti 10) Sump at Sarathanagar
0.60 LL 1) Manur 2) Chettikulam 3) Nakkalamuthampatti
1.00 LL Thalavaipuram
2.00 LL Thiruvengadam
3.00 LL Sankarankovil
5.00 LL 1) Booster at Thiruvenkatam 2) Booster at Seval patti 3) Booster at Keelanmarainadu 4) Booster at Sithurajapuram
1.00 LL MSR AT SAMABAKULAM
2.00 LL MSR Vadakku KuruviKulam
1.00 LL MSR @KalliKulam
4.00 LL MSR @ANAIYUR
2.00 LL MSR @Sankarankoil
2.00 LL MSR @Ettiseri
1.00 LL MSR @Vadakku-malaiyadipatti
0.60 LL MSR @ Kalingapatti
2.00 LL MSR @ Nakkalamuthanpatti
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 27.82MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 10154.30 ML (27.82*365 )
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes -4272.549 cum AC Pipes - 495.249 cum
Removing the burst P.V.C./A.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
300 mm dia A.C. Pipes
250 mm dia A.C. Pipes
200 mm dia A.C. Pipes
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
160mm PVC 4 KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of AC pipes of 5 m length and specials confirming to IS other specifications amended from time to time having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc., complete and as directed by TWAD Board officers.
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 300 NB AC Class 15
For 250 NB AC Class 15
For 200 NB AC Class 15
Attending Collar Leaks in the Pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
AC Collar leak - 909.761 cum PSC Collar Leak - 2905.247 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 714.00 Kg PSC Pipe -2425.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -952.00 litre PSC Pipe -2495.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -714.00 Kg PSC Pipe - 3715 kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
AC pipe -952.00 hrs PSC Pipe -3013.00 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
AC pipe - 909.761 cum PSC Pipe - 2905.247 cum
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) GI pipe - 86.63 Cum 2) OPVC and DI pipe -46.268 cum 3) PSC and AC pipe - 679.704 cum 4) MS pipes loacted PSC pipe line - 409.551 cum
Supply and delivery of the following sizes of GI medium pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Supply and delivery of following sizes of GI Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
25 mm Coupling
40 mm Coupling
50 mm Coupling
65 mm Coupling
80 mm Coupling
100mm Coupling
50 mm Flange set
65 mm Flange set
80 mm Flange set
100mm Flange set
50 mm Rubber sheet for Flange set
65 mm Rubber sheet for Flange set
80 mm Rubber sheet for Flange set
100mm Rubber sheet for Flange set
40 mm Hex nipple
50 mm Hex nipple
65 mm Hex nipple
80 mm Hex nipple
100mm Hex nipple
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
25 mm GI Pipe
40 mm GI Pipe
50 mm GI Pipe
65 mm GI Pipe
80 mm GI Pipe
100 mm GI Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63 mm x 20 mm
75 mm x 20 mm
90 mm x 20 mm
Supply, Delivery and fixing of CI SINGLE AIR VALVE AS PER ISI 14845/2000 AND WITH 5 YEARS WARRANT inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
Supply and delivery of the following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 AS PER IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200 mm dia DI K7
350 mm dia DI K7
Supply and delivery of the following sizes of UN PLASTICIZED O-PVC PIPES FOR POTABLE WATER SUPPLY AS PER IS 16647 / 2017 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
250 mm dia OPVC PN 12.5 Class 500
Supply and delivery of the following sizes of MOULDED (OR) FABRICATED O-PVC FITTINGS COMPATIBLE WITH O-PVC PIPES
SLIDING COUPLER DN 250mm
Supply and Delivery of MJ Collars as directed by TWAD Board officers IS 8794/1988 etc., complete and as directed by TWAD Board officers
200 mm dia DI K7
350 mm dia DI K7
Supply and delivery of Leak Arresting Flexible MS Clamps etc., complete and as directed by TWAD Board officers
For 800mm PSC of various classes Pipe
For 500 NB PSC of various classes Pipe
For 450 NB PSC of various classes Pipe
For 350 NB PSC of various classes Pipe
For 300 NB AC of various classes Pipe
For 250 NB AC of various classes Pipe
For 200 NB AC of various classes Pipe
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
PSC and AC pipes - 628 hrs MS pipes located PSc pipelines - 407 hrs
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
PSC and AC pipe
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
PSC and AC pipe
Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
MS pipes located PSc pipelines
Hire charges for Generator for electric current for attending leaks by fabrication of MS pipes and specials including fuel, Transportation etc., Complete as directed by TWAD Officials
MS pipes located PSc pipelines
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
813 mm x 7.1 mm thick MS PIPE
355.6 mm x 5 mm thick MS PIPE
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) GI pipe - 86.63 Cum 2) OPVC and DI pipe -46.268 cum 3) PSC and AC pipe - 679.704 cum 4) MS pipes loacted PSC pipe line - 409.551 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
Monoblock Pump set
Rewinding of motor and and repair works to vertical turbine / HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Vertical turbine motor
HSC motor
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Attending Major Fault in Transformer
Labour Charges for dismantling of Transformer upto 500 KVA at Booster Stations with all accessories by using crane etc.complete as directed by TWAD Board officers
500 KVA TRANSFORMER LOCATED IN PAZHAVOOR HEADWORKS - 2 NOS (1 STANDBYE) & AZHAGIYAPANDIPURAM BOOSTER - 2 NOS (1 STANDBYE)
400KVA TRANSFORMER LOCATED IN SIRUKANKURICHI BOOSTER STATION - 2 NOS (1 STANDBYE)
250 KVA TRANSFORMER LOCATED IN NALUVASANKOTTAI BOOSTER STATION - 2 NOS (1 STANDBYE)
200 KVA TRANSFORMER LOCATED IN VADAKUACHAMPATTI BOOSTER STATION - 2 NOS (1 STANDBYE)
Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase Transformer upto 500KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to Transformer upto 500KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 3 phase insulation material for Transformer upto 500 KvA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of new transformer oil suitable for Transformers upto 500KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 11KV HV bushing with Metal parts for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of 433V LV bushing copper rod to upto 500 KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of silica gel breather suitable for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of capillary type thermometer including accessories suitable for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delivery of Gasket & Oil Seals suitable for 500KvA & 400KvA as directed by TWAD Board Officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
Supply and delivery of Gasket & Oil Seals suitable for 250KvA & 200KvA as directed by TWAD Board Officers.
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delievery of paint for Transformer upto 500 KVA as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days for Transformer upto 500 KVA etc.,complete as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for Transformer tank cleaning and painting work for Transformer upto 500 KVA as per IS Specification as directed by TWAD Board Officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 200 & 250 KVA Transformer as per IS specifications as directed by TWAD board officers..
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVa & 500 KVA Transformer as per IS specifications as directed by TWAD board officers..
500 KVA TRANSFORMER
400KVA TRANSFORMER
Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 200 KvA & 250 KVA Transformer as per IS specifications as directed by TWAD board officers.
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 Kva & 500 KVA Transformer as per IS specifications as directed by TWAD board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
Labour Charges for Re erection of Tranformers upto 500 KVA and all accessories at Booster Station by using crane and fixing etc complete as directed by Twad Board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Hiring Charges for Crane for Positioning of Transformer in Bed for fixing etc., Complete as directed by TWAD Board officers.
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Conveyance charges for transformers unit from Booster Station to work shop site and for rectification works from work shop site to Booster Station after completion of rectification works etc complete as directed by Twad Board officers
500 KVA TRANSFORMER
400KVA TRANSFORMER
250 KVA TRANSFORMER
200 KVA TRANSFORMER
Supply and delivery of Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc ., complete and as directed by TWAD Board officers
9 Amps\440V
12 Amps\440V
18 Amps\440V
25 Amps\440V
32 Amps\440V
40 Amps\440V
45 Amps\440V
95 Amps\440V
185 Amps\440V
300 Amps\440V
400 Amps\440V
Supply and delivery of following Electromechanical item as directed by TWAD Board Officials
Digital Ammeter 3 phase
Digital Voltmeter 3 phase
SUPPLY AND DELIVERY OF PVC INSULATED SINGLE CORE MULTI STRAND FIRE RETARDANT LOW SMOKE (FRLS) FLEXIBLE COPPER CABLEWITH ISI MARK CONFORMING TO IS
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5A
Upto 5A-10A
Upto 10A-20A
Upto 20A-30A
Upto 30A-50A
Upto 50A-75A
Upto 75A-110A
Upto 200A-300A
Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
5 HP Starter
3 HP Starter
2 HP Starter
1.5 HP Starter
1.0 HP Starter
25 HP Starter
22.5 HP Starter
22 HP Starter
20 HP Starter
17.5 HP Starter
10 HP Starter
7.5 HP Starter
Supply and delivery of floor mounted type FCMA Air/ Oil Cooled soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V (+/-10%) including line contactors suitable for next standard higher KW rating, Over load relay, instrument panel with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 70 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 4 Pole & 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
400 Amps MCCB
400 Amps Spreader Terminal
250 Amps MCCB
250 Amps Spreader Terminal
125 Amps MCCB
125 Amps Spreader Terminal
63 Amps MCCB
63 Amps Spreader Terminal
400 Amps MCCB
400 Amps Spreader Terminal
250 Amps MCCB
250 Amps Spreader Terminal
160 Amps MCCB
160 Amps Spreader Terminal
100 Amps MCCB
100 Amps Spreader Terminal
Supply and delivery of following Fuse unit etc., complete and as directed by TWAD Board officers
200 AMPS Porcelain Fuse unit
100 AMPS Porcelain Fuse unit
63 AMPS Porcelain Fuse unit
32 AMPS Porcelain Fuse unit
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI scour /CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
350 mm CI Sluice valve
350 mm CI NRV valve
300 mm CI Sluice valve
300 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
800 mm CI Sluice valve
700 mm CI Sluice valve
500 mm CI Sluice valve
450 mm CI Sluice valve
250 mm CI Sluice valve
150mm Double air valve
100mm Double air valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
15.00 LL 1) Pazhavoor(Headworks) 2) Sirukankuruchi 3) Madhavakuruchi 4) Alagiyapandiyapuram 5) Vadakku Achampatti 6) Naluvasankottai 7) Madhavakuruchi
1.50 LL Pazhavoor(Headworks) (Sump cum pumphouse)
0.10 LL 1) Vettuvankulam 2) Seethaparpanallur 3) Ayubhkanpuram 4) Vadakku Cheliyanallur 5) Therkku Achampatti 6) Devarkulam(Chettikuruchi) 7) Karisalkulam 8) Muthukrishnapuram
0.30 LL 1) Kankeyankulam 2) Rastha 3) Ettankulam 4) Melapilayarkulam 5) Therkku Puliyampatti 6) Vadanathampatti 7) Madathupatti 8) Panaiyur 9) Sump at Kunndampatti 10) Sump at Sarathanagar
0.60 LL 1) Manur 2) Chettikulam 3) Nakkalamuthampatti
1.00 LL Thalavaipuram
2.00 LL Thiruvengadam
3.00 LL Sankarankovil
5.00 LL 1) Booster at Thiruvenkatam 2) Booster at Seval patti 3) Booster at Keelanmarainadu 4) Booster at Sithurajapuram
1.00 LL MSR AT SAMABAKULAM
2.00 LL MSR Vadakku KuruviKulam
1.00 LL MSR @KalliKulam
4.00 LL MSR @ANAIYUR
2.00 LL MSR @Sankarankoil
2.00 LL MSR @Ettiseri
1.00 LL MSR @Vadakku-malaiyadipatti
0.60 LL MSR @ Kalingapatti
2.00 LL MSR @ Nakkalamuthanpatti
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A6 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 7.20 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 2628.00 ML (7.20*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various Sizes - 1604.415 cum ii) DI Pipe of various sizes - 479.546 cum
Removing the burst P.V.C/ DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000 other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Attending Collar Leak in DI Pipe pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of DI pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
DI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI Pipe of various sizes
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI Pipe of various sizes
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
DI Pipe of various sizes
Supply of CID Joint as per IS 8794/1988 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
DI Pipe of various sizes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
1 HP - STARTER
2 HP - STARTER
3 HP - STARTER
5 HP - STARTER
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
400 mm CI Sluice valve
400 mm CI NRV valve
350 mm CI Sluice valve
300 mm CI Sluice valve
250 mm CI Scour valve
250 mm CI NRV valve
200 mm CI Scour valve
200 mm CI Sluice valve
200 mm CI NRV valve
100 mm CI NRV valve
100 mm CI Sluice valve
100 mm Double Air Valve
80 mm Double Air Valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
3.00 LL capacity of sump @ Nanthanthattai (Head works)
3.00 LL capacity of sump @ Kandapatti
3.00 LL capacity of sump @Uthumalai
12.25 LL capacity of sump @ Kallathikulam
5.00 LL capacity of sump @ Sankarankovil
O THULUKKAR PATTI -0.50 LL
MAYAMANKURICHI - 1.80 LL
MEELAVEERANAM -0.25 LL
KIDARAKULAM0.70 LL
NACHIYARPURAM -0.60 LL
ACHANKUTTAM -0.95 LL
KEELAVEERANAM -1.90 LL
KURINCHAMPATTI -0.15 LL
MELAKALNGAL -0.75 LL
KARUVANTHA -2.20 LL
KEELAKALANGAL-1.05 LL
MELAMARUTHAPURAM -2.05 LL
PERIYAKOVILANKULAM-0.70 LL
SHUNMUGANALLUR -0.60 LL
NEDUNKULAM-0.15 LL
NAVANEETHAKRISHNAPURAM (KO- MARUTHAPPAPURAM)- 0.60 LL
ELANTHAIKULAM -0.25 LL
MELANEETHANALLUR-0.80 LL
KEELANEETHANALLUR-1.00 LL
KURRUKALLAL PATTI -1.05 LL
ECHANDA - 0.30 LL
MARUTHAMUTHUR-1.15 LL
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 7.20 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 2635.20 ML (7.20*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various Sizes - 1604.415 cum ii) DI Pipe of various sizes - 479.546 cum
Removing the burst P.V.C/ DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000 other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Attending Collar Leak in DI Pipe pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of DI pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
DI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI Pipe of various sizes
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI Pipe of various sizes
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
DI Pipe of various sizes
Supply of CID Joint as per IS 8794/1988 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
DI Pipe of various sizes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
1 HP - STARTER
2 HP - STARTER
3 HP - STARTER
5 HP - STARTER
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
400 mm CI Sluice valve
400 mm CI NRV valve
350 mm CI Sluice valve
300 mm CI Sluice valve
250 mm CI Scour valve
250 mm CI NRV valve
200 mm CI Scour valve
200 mm CI Sluice valve
200 mm CI NRV valve
100 mm CI NRV valve
100 mm CI Sluice valve
100 mm Double Air Valve
80 mm Double Air Valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
3.00 LL capacity of sump @ Nanthanthattai (Head works)
3.00 LL capacity of sump @ Kandapatti
3.00 LL capacity of sump @Uthumalai
12.25 LL capacity of sump @ Kallathikulam
5.00 LL capacity of sump @ Sankarankovil
O THULUKKAR PATTI -0.50 LL
MAYAMANKURICHI - 1.80 LL
MEELAVEERANAM -0.25 LL
KIDARAKULAM0.70 LL
NACHIYARPURAM -0.60 LL
ACHANKUTTAM -0.95 LL
KEELAVEERANAM -1.90 LL
KURINCHAMPATTI -0.15 LL
MELAKALNGAL -0.75 LL
KARUVANTHA -2.20 LL
KEELAKALANGAL-1.05 LL
MELAMARUTHAPURAM -2.05 LL
PERIYAKOVILANKULAM-0.70 LL
SHUNMUGANALLUR -0.60 LL
NEDUNKULAM-0.15 LL
NAVANEETHAKRISHNAPURAM (KO- MARUTHAPPAPURAM)- 0.60 LL
ELANTHAIKULAM -0.25 LL
MELANEETHANALLUR-0.80 LL
KEELANEETHANALLUR-1.00 LL
KURRUKALLAL PATTI -1.05 LL
ECHANDA - 0.30 LL
MARUTHAMUTHUR-1.15 LL
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 7.20 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 2628.00 ML (7.20*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various Sizes - 1604.415 cum ii) DI Pipe of various sizes - 479.546 cum
Removing the burst P.V.C/ DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000 other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Attending Collar Leak in DI Pipe pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of DI pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
DI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI Pipe of various sizes
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI Pipe of various sizes
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
DI Pipe of various sizes
Supply of CID Joint as per IS 8794/1988 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
450 mm dia DI k7 Pipe
400 mm dia DI k9 Pipe
400 mm dia DI k7 Pipe
350 mm dia DI k7 Pipe
300 mm dia DI k7 Pipe
250 mm dia DI k7 Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
DI Pipe of various sizes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
1 HP - STARTER
2 HP - STARTER
3 HP - STARTER
5 HP - STARTER
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 35 Sq. mm aluminium cable
3 core 50 Sq. mm aluminium cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
400 mm CI Sluice valve
400 mm CI NRV valve
350 mm CI Sluice valve
300 mm CI Sluice valve
250 mm CI Scour valve
250 mm CI NRV valve
200 mm CI Scour valve
200 mm CI Sluice valve
200 mm CI NRV valve
100 mm CI NRV valve
100 mm CI Sluice valve
100 mm Double Air Valve
80 mm Double Air Valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
3.00 LL capacity of sump @ Nanthanthattai (Head works)
3.00 LL capacity of sump @ Kandapatti
3.00 LL capacity of sump @Uthumalai
12.25 LL capacity of sump @ Kallathikulam
5.00 LL capacity of sump @ Sankarankovil
O THULUKKAR PATTI -0.50 LL
MAYAMANKURICHI - 1.80 LL
MEELAVEERANAM -0.25 LL
KIDARAKULAM0.70 LL
NACHIYARPURAM -0.60 LL
ACHANKUTTAM -0.95 LL
KEELAVEERANAM -1.90 LL
KURINCHAMPATTI -0.15 LL
MELAKALNGAL -0.75 LL
KARUVANTHA -2.20 LL
KEELAKALANGAL-1.05 LL
MELAMARUTHAPURAM -2.05 LL
PERIYAKOVILANKULAM-0.70 LL
SHUNMUGANALLUR -0.60 LL
NEDUNKULAM-0.15 LL
NAVANEETHAKRISHNAPURAM (KO- MARUTHAPPAPURAM)- 0.60 LL
ELANTHAIKULAM -0.25 LL
MELANEETHANALLUR-0.80 LL
KEELANEETHANALLUR-1.00 LL
KURRUKALLAL PATTI -1.05 LL
ECHANDA - 0.30 LL
MARUTHAMUTHUR-1.15 LL
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A7 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.06 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally386.900 ML (1.06*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various Sizes
Removing the burst HDPE pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm HDPE PN6 Pipe
63mm HDPE PN6 Pipe
75mm HDPE PN6 Pipe
90mm HDPE PN6 Pipe
110mm HDPE PN6 Pipe
160mm HDPE PN6 Pipe
200mm HDPE PN6 Pipe
Supply and delivery of the following sizes of unplastisized HDPE pipes and Specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm HDPE PN6 Pipe
63mm HDPE PN6 Pipe
75mm HDPE PN6 Pipe
90mm HDPE PN6 Pipe
110mm HDPE PN6 Pipe
160mm HDPE PN6 Pipe
200mm HDPE PN6 Pipe
PVC Specials
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part 2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
7.5 HP Open Well Submersible Pump Set - Sattupathu
17.5 HP Open Well Submersible Pump Set - Sattupathu
1 HP Open Well Submersible Pump Set - Sattupathu
10 HP Open Well Submersible Pump Set - Brammadesam and Mannarkovil
5 HP Open Well Submersible Pump Set - Brammadesam
4 HP Open Well Submersible Pump Set - Vagaikulam
2 HP Open Well Submersible Pump Set - Vagaikulam
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 70 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 70 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 70 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 63 Amps 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
250 mm CI Sluice valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.70 LL - Sattupathu
3.05 LL - Brammadesam
2.10 LL - Vagaikulam
1.15 LL - Mannarkovil
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as Common salt, bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply, Delivery of common salt for Electro Cholorinator arrangements in the schemes maintained by TWAD Board etc., complete and as directed by TWAD Board Officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.07 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 391.620 ML (1.07*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various Sizes
Removing the burst HDPE pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm HDPE PN6 Pipe
63mm HDPE PN6 Pipe
75mm HDPE PN6 Pipe
90mm HDPE PN6 Pipe
110mm HDPE PN6 Pipe
160mm HDPE PN6 Pipe
200mm HDPE PN6 Pipe
Supply and delivery of the following sizes of unplastisized HDPE pipes and Specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm HDPE PN6 Pipe
63mm HDPE PN6 Pipe
75mm HDPE PN6 Pipe
90mm HDPE PN6 Pipe
110mm HDPE PN6 Pipe
160mm HDPE PN6 Pipe
200mm HDPE PN6 Pipe
PVC Specials
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part 2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
7.5 HP Open Well Submersible Pump Set - Sattupathu
17.5 HP Open Well Submersible Pump Set - Sattupathu
1 HP Open Well Submersible Pump Set - Sattupathu
10 HP Open Well Submersible Pump Set - Brammadesam and Mannarkovil
5 HP Open Well Submersible Pump Set - Brammadesam
4 HP Open Well Submersible Pump Set - Vagaikulam
2 HP Open Well Submersible Pump Set - Vagaikulam
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 70 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 70 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 70 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 63 Amps 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
250 mm CI Sluice valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.70 LL - Sattupathu
3.05 LL - Brammadesam
2.10 LL - Vagaikulam
1.15 LL - Mannarkovil
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as Common salt, bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply, Delivery of common salt for Electro Cholorinator arrangements in the schemes maintained by TWAD Board etc., complete and as directed by TWAD Board Officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.07 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 390.55 ML (1.07*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various Sizes
Removing the burst HDPE pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm HDPE PN6 Pipe
63mm HDPE PN6 Pipe
75mm HDPE PN6 Pipe
90mm HDPE PN6 Pipe
110mm HDPE PN6 Pipe
160mm HDPE PN6 Pipe
200mm HDPE PN6 Pipe
Supply and delivery of the following sizes of unplastisized HDPE pipes and Specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm HDPE PN6 Pipe
63mm HDPE PN6 Pipe
75mm HDPE PN6 Pipe
90mm HDPE PN6 Pipe
110mm HDPE PN6 Pipe
160mm HDPE PN6 Pipe
200mm HDPE PN6 Pipe
PVC Specials
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part 2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
7.5 HP Open Well Submersible Pump Set - Sattupathu
17.5 HP Open Well Submersible Pump Set - Sattupathu
1 HP Open Well Submersible Pump Set - Sattupathu
10 HP Open Well Submersible Pump Set - Brammadesam and Mannarkovil
5 HP Open Well Submersible Pump Set - Brammadesam
4 HP Open Well Submersible Pump Set - Vagaikulam
2 HP Open Well Submersible Pump Set - Vagaikulam
Attending Cable fault
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 70 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 70 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 70 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 63 Amps 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
150 mm CI Sluice valve
150 mm CI Scour valve
100 mm CI Sluice valve
100 mm CI NRV valve
250 mm CI Sluice valve
80 mm Double air valve
50 mm Double air valve
40 mm Double air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.70 LL - Sattupathu
3.05 LL - Brammadesam
2.10 LL - Vagaikulam
1.15 LL - Mannarkovil
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as Common salt, bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply, Delivery of common salt for Electro Cholorinator arrangements in the schemes maintained by TWAD Board etc., complete and as directed by TWAD Board Officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A8 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.88 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1051.20 ML (2.88*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc.,rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various sizes - 626.278 cum ii) AC Pipes of various sizes - 206.434 cum iii) 350 mm PSC Pipes - 162.460 cum
Removing the burst P.V.C./AC/PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200 mm AC Pipe
250 mm AC Pipe
350 mm PSC Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200 mm DI K7 Class
250 mm DI K7 Class
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 200 mm Class 15 CID Joint
For 250 mm Class 15 CID Joint
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
355.6x5.6 mm thick MS pipes
Supply and Delivery of MJ Collars as directed by TWAD Board officers
350mm PSC Pipes various classes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) AC Pipe of various size - 185.791 cum ii) 350 mm PSC Pipe - 122.212 cum iii)350mm PSC Pippe (SS clamp) - 122.212 cum
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i) 250 mm AC Pipe - 108 kg ii) 200 mm AC Pipe - 72 kg iii) 350 mm PSC Pipe - 144 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 250 mm AC Pipe - 108 lit ii) 200 mm AC Pipe - 72 lit iii) 350 mm PSC Pipe - 108 lit
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 250 mm AC Pipe - 216 kg ii) 200 mm AC Pipe - 180 kg iii) 350 mm PSC Pipe - 252 kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
i) 250 mm AC Pipe - 72 hrs ii) 200 mm AC Pipe - 36 hrs iii) 350 mm PSC Pipe - 108 hrs iv)350 mm PSC Pipe (SS clamp)- 78 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
350 mm PSC Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
i) AC Pipe of various size - 185.791 cum ii) 350 mm PSC Pipe - 122.212 cum iii)350mm PSC Pippe (SS clamp) - 122.212 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board officers Upto 5 HP
Supply and delivery of Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
12 Amps\440V
18 Amps\440V
25 Amps\440V
32 Amps\440V
110 Amps\440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5A-10A
Upto 10A-20A
Upto 30A-50A
Upto 75A-110A
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps - 500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3.00 core 35 Sq. mm Aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3.00 core 35 Sq. mm Aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3.00 core 35 Sq. mm Aluminium cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Single/Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Single Air release valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.10 LL capacity Sump @ Ayaneri,Ambalam and Kathanadaippu
0.30 LL capacity Sump @ Maruthakulam,senbagaramanallur,Ilayarkulam,Alwarkulam
0.60 LL capacity Sump @ Kadankulam
1.00 LL capacity Sump @ Moolaikaraipatti
2.00 LL capacity Sump @ Thirumalaikolundhupuram,Krishnapuram and Pudukurichi
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work depolying earth moving machineries for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc,complete.Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.88 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1054.08 ML (2.88*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc.,rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various sizes - 626.278 cum ii) AC Pipes of various sizes - 206.434 cum iii) 350 mm PSC Pipes - 162.460 cum
Removing the burst P.V.C./AC/PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200 mm AC Pipe
250 mm AC Pipe
350 mm PSC Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200 mm DI K7 Class
250 mm DI K7 Class
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 200 mm Class 15 CID Joint
For 250 mm Class 15 CID Joint
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
355.6x5.6 mm thick MS pipes
Supply and Delivery of MJ Collars as directed by TWAD Board officers
350mm PSC Pipes various classes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) AC Pipe of various size - 185.791 cum ii) 350 mm PSC Pipe - 122.212 cum iii)350mm PSC Pippe (SS clamp) - 122.212 cum
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i) 250 mm AC Pipe - 108 kg ii) 200 mm AC Pipe - 72 kg iii) 350 mm PSC Pipe - 144 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 250 mm AC Pipe - 108 lit ii) 200 mm AC Pipe - 72 lit iii) 350 mm PSC Pipe - 108 lit
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 250 mm AC Pipe - 216 kg ii) 200 mm AC Pipe - 180 kg iii) 350 mm PSC Pipe - 252 kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
i) 250 mm AC Pipe - 72 hrs ii) 200 mm AC Pipe - 36 hrs iii) 350 mm PSC Pipe - 108 hrs iv)350 mm PSC Pipe (SS clamp)- 78 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
350 mm PSC Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
i) AC Pipe of various size - 185.791 cum ii) 350 mm PSC Pipe - 122.212 cum iii)350mm PSC Pippe (SS clamp) - 122.212 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board officers Upto 5 HP
Supply and delivery of Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
12 Amps\440V
18 Amps\440V
25 Amps\440V
32 Amps\440V
110 Amps\440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5A-10A
Upto 10A-20A
Upto 30A-50A
Upto 75A-110A
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps - 500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3.00 core 35 Sq. mm Aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3.00 core 35 Sq. mm Aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3.00 core 35 Sq. mm Aluminium cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Single/Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Single Air release valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.10 LL capacity Sump @ Ayaneri,Ambalam and Kathanadaippu
0.30 LL capacity Sump @ Maruthakulam,senbagaramanallur,Ilayarkulam,Alwarkulam
0.60 LL capacity Sump @ Kadankulam
1.00 LL capacity Sump @ Moolaikaraipatti
2.00 LL capacity Sump @ Thirumalaikolundhupuram,Krishnapuram and Pudukurichi
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work depolying earth moving machineries for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc,complete.Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.88 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1051.20 ML (2.88*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc.,rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various sizes - 626.278 cum ii) AC Pipes of various sizes - 206.434 cum iii) 350 mm PSC Pipes - 162.460 cum
Removing the burst P.V.C./AC/PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200 mm AC Pipe
250 mm AC Pipe
350 mm PSC Pipe
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200 mm DI K7 Class
250 mm DI K7 Class
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
For 200 mm Class 15 CID Joint
For 250 mm Class 15 CID Joint
Supply and Delivery of following MS pipes of as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm for 168.3 mm OD to 2540 mm OD as per Table -8 of IS 3589:2001 2.Pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement as per clause A-9 of Annex-A of IS 3589:2001 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
355.6x5.6 mm thick MS pipes
Supply and Delivery of MJ Collars as directed by TWAD Board officers
350mm PSC Pipes various classes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) AC Pipe of various size - 185.791 cum ii) 350 mm PSC Pipe - 122.212 cum iii)350mm PSC Pippe (SS clamp) - 122.212 cum
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i) 250 mm AC Pipe - 108 kg ii) 200 mm AC Pipe - 72 kg iii) 350 mm PSC Pipe - 144 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 250 mm AC Pipe - 108 lit ii) 200 mm AC Pipe - 72 lit iii) 350 mm PSC Pipe - 108 lit
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 250 mm AC Pipe - 216 kg ii) 200 mm AC Pipe - 180 kg iii) 350 mm PSC Pipe - 252 kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
i) 250 mm AC Pipe - 72 hrs ii) 200 mm AC Pipe - 36 hrs iii) 350 mm PSC Pipe - 108 hrs iv)350 mm PSC Pipe (SS clamp)- 78 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
350 mm PSC Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
i) AC Pipe of various size - 185.791 cum ii) 350 mm PSC Pipe - 122.212 cum iii)350mm PSC Pippe (SS clamp) - 122.212 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board officers Upto 5 HP
Supply and delivery of Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board officers
12 Amps\440V
18 Amps\440V
25 Amps\440V
32 Amps\440V
110 Amps\440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5A-10A
Upto 10A-20A
Upto 30A-50A
Upto 75A-110A
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps - 500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3.00 core 35 Sq. mm Aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3.00 core 35 Sq. mm Aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3.00 core 35 Sq. mm Aluminium cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Single/Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Single Air release valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.10 LL capacity Sump @ Ayaneri,Ambalam and Kathanadaippu
0.30 LL capacity Sump @ Maruthakulam,senbagaramanallur,Ilayarkulam,Alwarkulam
0.60 LL capacity Sump @ Kadankulam
1.00 LL capacity Sump @ Moolaikaraipatti
2.00 LL capacity Sump @ Thirumalaikolundhupuram,Krishnapuram and Pudukurichi
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work depolying earth moving machineries for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc,complete.Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A9 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027_
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.70 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 958.50 ML (2.70*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.PVC COUPLER FABRICATED
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Attending burst in DI pipes using CID joints
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
300mm CID Joints
350mm CID Joints
Attending burst in DI pipes using MJ collar
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and Delivery of MJ Collars as directed by TWAD Board officers
300mm MJ Collar
350mm MJ Collar
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.DI Pipe of various sizes
Attending collar leak in DI pipes
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Board officers.
Supply and delivery of Hardcrete oil as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Board officers.
Supply and delivery of cement.
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.(
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
Attending leak in DI pipes using MS clamp
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
300mm MS Clamp
350mm MS Clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and reconditioning works in 70HP HSC centrifugal pump including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC pumpset
Supply and delivery of following capacity of 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1
12 Amps Contactor
18 Amps Contactor
50 Amps Contactor
110 Amps Contactor
Supply and delivery of following capacity of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
For 5 HP Starter - 4 Nos
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 25 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 25 Sq. mm aluminium cable
Supply and delivery of following Range of 3 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.
Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Repairing/ reconditioning of Sluice valve (for line valve/ for Scour valve) including all material, labour (Specify type of sluice valve and type of repair to be carried out)
125mm CI Sluice valve
200mm CI Sluice valve
250mm CI Sluice valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.80 LL capacity of sump @ Muthalankurichi
1.85 LL capacity of sump @ K. navalady
0.70 LL capacity of sump @ B.oovari
0.50 LL capacity of sump @ KN Ovari
0.80 LL capacity of sump @ Kuttam
0.90 LL capacity of sump @ Kuthankuli
5.80 LL capacity of sump @ Thiruvembalapuram
0.30 LL capacity of sump @ parameshwarapuram
0.35 LL capacity of sump @ Udhayathur
1.35 LL capacity of sump @ Vijayapathi
1.60 LL capacity of sump @ Koodankulam
0.60 LL capacity of sump @ Iruukandurai
1.35 LL capacity of sump @ chettikulam
1.85 LL capacity of sump @ Levinjipuram
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of Leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028_
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.70 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 988.20 ML (2.70*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.PVC COUPLER FABRICATED
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Attending burst in DI pipes using CID joints
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
300mm CID Joints
350mm CID Joints
Attending burst in DI pipes using MJ collar
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and Delivery of MJ Collars as directed by TWAD Board officers
300mm MJ Collar
350mm MJ Collar
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.DI Pipe of various sizes
Attending collar leak in DI pipes
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Board officers.
Supply and delivery of Hardcrete oil as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Board officers.
Supply and delivery of cement.
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.(
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
Attending leak in DI pipes using MS clamp
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
300mm MS Clamp
350mm MS Clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and reconditioning works in 70HP HSC centrifugal pump including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC pumpset
Supply and delivery of following capacity of 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1
12 Amps Contactor
18 Amps Contactor
50 Amps Contactor
110 Amps Contactor
Supply and delivery of following capacity of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
For 5 HP Starter - 4 Nos
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 25 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 25 Sq. mm aluminium cable
Supply and delivery of following Range of 3 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.
Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Repairing/ reconditioning of Sluice valve (for line valve/ for Scour valve) including all material, labour (Specify type of sluice valve and type of repair to be carried out)
125mm CI Sluice valve
200mm CI Sluice valve
250mm CI Sluice valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.80 LL capacity of sump @ Muthalankurichi
1.85 LL capacity of sump @ K. navalady
0.70 LL capacity of sump @ B.oovari
0.50 LL capacity of sump @ KN Ovari
0.80 LL capacity of sump @ Kuttam
0.90 LL capacity of sump @ Kuthankuli
5.80 LL capacity of sump @ Thiruvembalapuram
0.30 LL capacity of sump @ parameshwarapuram
0.35 LL capacity of sump @ Udhayathur
1.35 LL capacity of sump @ Vijayapathi
1.60 LL capacity of sump @ Koodankulam
0.60 LL capacity of sump @ Iruukandurai
1.35 LL capacity of sump @ chettikulam
1.85 LL capacity of sump @ Levinjipuram
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of Leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029_
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.70 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 985.50 ML (2.70*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.PVC COUPLER FABRICATED
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Attending burst in DI pipes using CID joints
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
300mm CID Joints
350mm CID Joints
Attending burst in DI pipes using MJ collar
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
300 mm DI pipe
350mm DI pipe
Supply and Delivery of MJ Collars as directed by TWAD Board officers
300mm MJ Collar
350mm MJ Collar
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.DI Pipe of various sizes
Attending collar leak in DI pipes
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Board officers.
Supply and delivery of Hardcrete oil as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Board officers.
Supply and delivery of cement.
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.(
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
Attending leak in DI pipes using MS clamp
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. DI Pipe of various sizes
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
300mm MS Clamp
350mm MS Clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and reconditioning works in 70HP HSC centrifugal pump including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC pumpset
Supply and delivery of following capacity of 440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1
12 Amps Contactor
18 Amps Contactor
50 Amps Contactor
110 Amps Contactor
Supply and delivery of following capacity of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
For 5 HP Starter - 4 Nos
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3 core 25 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 25 Sq. mm aluminium cable
Supply and delivery of following Range of 3 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.
Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Repairing/ reconditioning of Sluice valve (for line valve/ for Scour valve) including all material, labour (Specify type of sluice valve and type of repair to be carried out)
125mm CI Sluice valve
200mm CI Sluice valve
250mm CI Sluice valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.80 LL capacity of sump @ Muthalankurichi
1.85 LL capacity of sump @ K. navalady
0.70 LL capacity of sump @ B.oovari
0.50 LL capacity of sump @ KN Ovari
0.80 LL capacity of sump @ Kuttam
0.90 LL capacity of sump @ Kuthankuli
5.80 LL capacity of sump @ Thiruvembalapuram
0.30 LL capacity of sump @ parameshwarapuram
0.35 LL capacity of sump @ Udhayathur
1.35 LL capacity of sump @ Vijayapathi
1.60 LL capacity of sump @ Koodankulam
0.60 LL capacity of sump @ Iruukandurai
1.35 LL capacity of sump @ chettikulam
1.85 LL capacity of sump @ Levinjipuram
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of Leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A10 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026- 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 3.80 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1387.00 ML (3.80*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
200mm PVC 4 KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
200mm PVC 4 KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
PVC COUPLER FABRICATED
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
LEAK IN BWSC PIPES
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
350 mm BWSC Pipe
Supply and delivery of following MS plates including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
MS Plate
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
350 mm BWSC Pipe
Hire Charges for Genset including Labour Charges for Operating the equipements and cost of Fuel for Eight Hours Operation, including conveyance to the site etc., complete and as directed by the TWAD Board officers.
62.5 KVA Genset Rent
Diesel Charge
Genset Operater Charges(Unskilled)
Welding Charges for welding cutopened Manhole including welding of lapping strips, including Labour Charges for Operating the equipements for Eight Hours Operation and including Grinding and allied works etc.,
Welding Machine AR 400 Rent
Welding rod at the rate of 80 Rods per 1 m of 1/2" welding in 2 layer
Welder Charges (Ist Class)
Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
350 mm BWSC Pipe
LEAKS WITH MS CLAMPS IN HDPE PIPES
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by TWAD Board officers HDPE Pipes of various sizes
Supply and delivery of Leak Arresting Flexible MS Clamp Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
140 mm MS clamp
250 mm MS clamp
280 mm MS clamp
315 mm MS clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
i) 140 mm HDPE - 48 hrs ii) 250 mm HDPE- 96 hrs iii) 280 mm HDPE - 80 hrs iv) 315 mm HDPE - 120 hrs
HDPE Pipes of various sizes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 75 HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 75 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
25 Amps Contactor
32 Amps Contactor
110 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately). etc., complete and as directed by TWAD Board officers Upto 5 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 95 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3core 95 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 95 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers 80 KVAR Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Single/Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
350 mm CI Sluice valve
250 mm CI Sluice valve
125 mm CI Sluice valve
100 mm CI Sluice valve
80 mm CI Sluice valve
CI NRV valve
150 mm CI NRV valve
125 mm CI NRV valve
100 mm CI NRV valve
80 mm CI NRV valve
65 mm CI NRV valve
50 mm CI NRV Valve
single Airvalve
100 mm single airvalve
80 mm single airvalve
50 mm single airvalve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.00 LL capacity of sump @ Ponnakurichi
1.50 LL capacity of sump @ Thottavilai
1.00 LL capacity of sump @ Koodankulam
0.30 LL capacity of sump @Idayankudi,chokalingapuram , vijayapathi, koodankulam ,Irukandurai and Levinjipuram
0.15 LL capacity of sump @ Idayankudi,Vemmanankudi,Thiruvembalapuram.vijayapathi,Kootapuli.
0.10 LL capacity of sump @ Keela Oovari
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of Leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 3.80 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1390.80 ML (3.80*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
200mm PVC 4 KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
200mm PVC 4 KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
PVC COUPLER FABRICATED
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
LEAK IN BWSC PIPES
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
350 mm BWSC Pipe
Supply and delivery of following MS plates including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
MS Plate
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
350 mm BWSC Pipe
Hire Charges for Genset including Labour Charges for Operating the equipements and cost of Fuel for Eight Hours Operation, including conveyance to the site etc., complete and as directed by the TWAD Board officers.
62.5 KVA Genset Rent
Diesel Charge
Genset Operater Charges(Unskilled)
Welding Charges for welding cutopened Manhole including welding of lapping strips, including Labour Charges for Operating the equipements for Eight Hours Operation and including Grinding and allied works etc.,
Welding Machine AR 400 Rent
Welding rod at the rate of 80 Rods per 1 m of 1/2" welding in 2 layer
Welder Charges (Ist Class)
Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
350 mm BWSC Pipe
LEAKS WITH MS CLAMPS IN HDPE PIPES
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by TWAD Board officers HDPE Pipes of various sizes
Supply and delivery of Leak Arresting Flexible MS Clamp Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
140 mm MS clamp
250 mm MS clamp
280 mm MS clamp
315 mm MS clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
i) 140 mm HDPE - 48 hrs ii) 250 mm HDPE- 96 hrs iii) 280 mm HDPE - 80 hrs iv) 315 mm HDPE - 120 hrs
HDPE Pipes of various sizes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 75 HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 75 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
25 Amps Contactor
32 Amps Contactor
110 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately). etc., complete and as directed by TWAD Board officers Upto 5 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 95 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3core 95 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 95 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers 80 KVAR Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Single/Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
350 mm CI Sluice valve
250 mm CI Sluice valve
125 mm CI Sluice valve
100 mm CI Sluice valve
80 mm CI Sluice valve
CI NRV valve
150 mm CI NRV valve
125 mm CI NRV valve
100 mm CI NRV valve
80 mm CI NRV valve
65 mm CI NRV valve
50 mm CI NRV Valve
single Airvalve
100 mm single airvalve
80 mm single airvalve
50 mm single airvalve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.00 LL capacity of sump @ Ponnakurichi
1.50 LL capacity of sump @ Thottavilai
1.00 LL capacity of sump @ Koodankulam
0.30 LL capacity of sump @Idayankudi,chokalingapuram , vijayapathi, koodankulam ,Irukandurai and Levinjipuram
0.15 LL capacity of sump @ Idayankudi,Vemmanankudi,Thiruvembalapuram.vijayapathi,Kootapuli.
0.10 LL capacity of sump @ Keela Oovari
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of Leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 3.80 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1387.00 ML (3.80*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
200mm PVC 4 KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4 KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4 KSC
140mm PVC 4 KSC
200mm PVC 4 KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
PVC COUPLER FABRICATED
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
LEAK IN BWSC PIPES
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
350 mm BWSC Pipe
Supply and delivery of following MS plates including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
MS Plate
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
350 mm BWSC Pipe
Hire Charges for Genset including Labour Charges for Operating the equipements and cost of Fuel for Eight Hours Operation, including conveyance to the site etc., complete and as directed by the TWAD Board officers.
62.5 KVA Genset Rent
Diesel Charge
Genset Operater Charges(Unskilled)
Welding Charges for welding cutopened Manhole including welding of lapping strips, including Labour Charges for Operating the equipements for Eight Hours Operation and including Grinding and allied works etc.,
Welding Machine AR 400 Rent
Welding rod at the rate of 80 Rods per 1 m of 1/2" welding in 2 layer
Welder Charges (Ist Class)
Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
350 mm BWSC Pipe
LEAKS WITH MS CLAMPS IN HDPE PIPES
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by TWAD Board officers HDPE Pipes of various sizes
Supply and delivery of Leak Arresting Flexible MS Clamp Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
140 mm MS clamp
250 mm MS clamp
280 mm MS clamp
315 mm MS clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
i) 140 mm HDPE - 48 hrs ii) 250 mm HDPE- 96 hrs iii) 280 mm HDPE - 80 hrs iv) 315 mm HDPE - 120 hrs
HDPE Pipes of various sizes
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 75 HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 75 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
25 Amps Contactor
32 Amps Contactor
110 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately). etc., complete and as directed by TWAD Board officers Upto 5 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3core 95 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules For laying below GL including earth work
3core 95 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 95 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers 80 KVAR Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Single/Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
350 mm CI Sluice valve
250 mm CI Sluice valve
125 mm CI Sluice valve
100 mm CI Sluice valve
80 mm CI Sluice valve
CI NRV valve
150 mm CI NRV valve
125 mm CI NRV valve
100 mm CI NRV valve
80 mm CI NRV valve
65 mm CI NRV valve
50 mm CI NRV Valve
single Airvalve
100 mm single airvalve
80 mm single airvalve
50 mm single airvalve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.00 LL capacity of sump @ Ponnakurichi
1.50 LL capacity of sump @ Thottavilai
1.00 LL capacity of sump @ Koodankulam
0.30 LL capacity of sump @Idayankudi,chokalingapuram , vijayapathi, koodankulam ,Irukandurai and Levinjipuram
0.15 LL capacity of sump @ Idayankudi,Vemmanankudi,Thiruvembalapuram.vijayapathi,Kootapuli.
0.10 LL capacity of sump @ Keela Oovari
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of Leading Channel Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A11 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 456.50 ML (1.66*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) PVC Pipes of various sizes - 179.484 Cum 2) DI pipes - 58.166 cum 3) CI pipes - 19.633 cum
Removing the burst P.V.C. /AC/CI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
150 mm AC pipe
150 mm CI pipe (6m + 3m)
200 mm CI pipe (6m + 3m)
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
150 mm DI K7 (24 m + 6 M)
200 mm DI K7 (12 m + 6 m))
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) AC/CI Pipe of various sizes(Collar leak) -42.177 cum 2) AC/CI Pipe of various sizes (MS clamp) - 44.670 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 42.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -42.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -96.00 Kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
AC pipe -18.00 hrs AC/CI Pipe (MS Clamp) -36.00hrs
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by the TWAD Board officers.
150 mm MS clamp
150 mm MS clamp
200 mm MS clamp
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) AC/CI Pipe of various sizes(Collar leak) -42.177 cum 2) AC/CI Pipe of various sizes (MS clamp) - 44.670 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and reconditioning pump and repair works to Centrifugal Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to10 A
Upto 10 A to 20 A
Upto 75 A to 110 A
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules For laying below GL including earth work
3core 10 Sq. mm Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm Copper cable
Supply and delivery of following Range 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps MCCB
250 Amps MCCB
Supply and delivery of following HRC Fuses etc., complete and as directed by TWAD Board officers
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
100 mm CI NRV Valve
150mm Sluice Valve
200 mm Sluice Valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.60 LL capacity of sump @ Mukkudal
0.15 LL capacity sump @ Alwarthulukarpatti
0.10 LL capacity sump @ Nalankurichi
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 607.56 ML (1.66*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) PVC Pipes of various sizes - 179.484 Cum 2) DI pipes - 58.166 cum 3) CI pipes - 19.633 cum
Removing the burst P.V.C. /AC/CI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
150 mm AC pipe
150 mm CI pipe (6m + 3m)
200 mm CI pipe (6m + 3m)
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
150 mm DI K7 (24 m + 6 M)
200 mm DI K7 (12 m + 6 m))
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) AC/CI Pipe of various sizes(Collar leak) -42.177 cum 2) AC/CI Pipe of various sizes (MS clamp) - 44.670 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 42.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -42.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -96.00 Kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
AC pipe -18.00 hrs AC/CI Pipe (MS Clamp) -36.00hrs
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by the TWAD Board officers.
150 mm MS clamp
150 mm MS clamp
200 mm MS clamp
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) AC/CI Pipe of various sizes(Collar leak) -42.177 cum 2) AC/CI Pipe of various sizes (MS clamp) - 44.670 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and reconditioning pump and repair works to Centrifugal Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to10 A
Upto 10 A to 20 A
Upto 75 A to 110 A
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules For laying below GL including earth work
3core 10 Sq. mm Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm Copper cable
Supply and delivery of following Range 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps MCCB
250 Amps MCCB
Supply and delivery of following HRC Fuses etc., complete and as directed by TWAD Board officers
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
100 mm CI NRV Valve
150mm Sluice Valve
200 mm Sluice Valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.60 LL capacity of sump @ Mukkudal
0.15 LL capacity sump @ Alwarthulukarpatti
0.10 LL capacity sump @ Nalankurichi
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 605.9 ML (1.66*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) PVC Pipes of various sizes - 179.484 Cum 2) DI pipes - 58.166 cum 3) CI pipes - 19.633 cum
Removing the burst P.V.C. /AC/CI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
150 mm AC pipe
150 mm CI pipe (6m + 3m)
200 mm CI pipe (6m + 3m)
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
150 mm DI K7 (24 m + 6 M)
200 mm DI K7 (12 m + 6 m))
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) AC/CI Pipe of various sizes(Collar leak) -42.177 cum 2) AC/CI Pipe of various sizes (MS clamp) - 44.67 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe - 42.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -42.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
AC pipe -96.00 Kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
AC pipe -18.00 hrs AC/CI Pipe (MS Clamp) -36.00 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by the TWAD Board officers.
150 mm MS clamp
150 mm MS clamp
200 mm MS clamp
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) AC/CI Pipe of various sizes(Collar leak) -42.177 cum 2) AC/CI Pipe of various sizes (MS clamp) - 44.67 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and reconditioning pump and repair works to Centrifugal Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to10 A
Upto 10 A to 20 A
Upto 75 A to 110 A
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules For laying below GL including earth work
3core 10 Sq. mm Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm Copper cable
Supply and delivery of following Range 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps MCCB
250 Amps MCCB
Supply and delivery of following HRC Fuses etc., complete and as directed by TWAD Board officers
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
100 mm CI NRV Valve
150mm Sluice Valve
200 mm Sluice Valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.60 LL capacity of sump @ Mukkudal
0.15 LL capacity sump @ Alwarthulukarpatti
0.10 LL capacity sump @ Nalankurichi
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A12 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.52 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 456.50 ML (1.52*554.80)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) DI pipes - 84.480 Cum 2) HDPE pipes with MS Clamp - 418.572 cum
Removing the burst P.V.C. /AC/CI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm DI K7 pipe
50mm HDPE Pipe
63mm HDPE Pipe
75mm HDPE Pipe
90mm HDPE Pipe
110mm HDPE Pipe
160mm HDPE Pipe
200 mm DI K7
50mm HDPE Pipe
63mm HDPE Pipe
75mm HDPE Pipe
90mm HDPE Pipe
110mm HDPE Pipe
160mm HDPE Pipe
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) DI Pipe (Collar Leak) -29.914 cum 2) DI Pipe with MS Clampset - 29.914 cum 3) HDPE Pipe with MS Clampset - 105.012 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe - 42.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe -42.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe-96.00 Kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
DI pipe -12.00 hrs DI Pipe (MS Clampset )- 12.00 hrs HDPE pipe (MS Clampset) -48.00 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by the TWAD Board officers.
160 mm MS clamp
200 mm MS clamp (12 + 24 )
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) DI Pipe-29.914 cum 2) DI pipe (MS clamp) - 29.914 cum 3) HDPE Pipe (MS Clamp) - 105.012 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and reconditioning pump and repair works to Centrifugal Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to10 A
Upto 10 A to 20 A
Upto 20 to 30 A
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules For laying below GL including earth work
3core 10 Sq. mm Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm Copper cable
Supply and delivery of following Range 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps MCCB
250 Amps MCCB
Supply and delivery of following Range 3 Pole MCB Switch Miniature ciruit Breaker etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of following HRC Fuses etc., complete and as directed by TWAD Board officers
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
50 mm Sluice Valve
80 mm Sluice Valve
100mm Sluice Valve
125 mm Sluice Valve
150 mm Sluice Valve
200 mm Sluice Valve
80 mm CI NRV Valve
125 mm Sluice Valve
40 mm Double Air valve
50mm Air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.35 LL capacity of sump @ Mukkudal
0.45 LL capacity sump @ Alwarthulukarpatti
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.52 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 556.32 ML (1.52*556.32)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) DI pipes - 84.480 Cum 2) HDPE pipes with MS Clamp - 418.572 cum
Removing the burst P.V.C. /AC/CI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm DI K7 pipe
50mm HDPE Pipe
63mm HDPE Pipe
75mm HDPE Pipe
90mm HDPE Pipe
110mm HDPE Pipe
160mm HDPE Pipe
200 mm DI K7
50mm HDPE Pipe
63mm HDPE Pipe
75mm HDPE Pipe
90mm HDPE Pipe
110mm HDPE Pipe
160mm HDPE Pipe
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) DI Pipe (Collar Leak) -29.914 cum 2) DI Pipe with MS Clampset - 29.914 cum 3) HDPE Pipe with MS Clampset - 105.012 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe - 42.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe -42.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe-96.00 Kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
DI pipe -12.00 hrs DI Pipe (MS Clampset )- 12.00 hrs HDPE pipe (MS Clampset) -48.00 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by the TWAD Board officers.
160 mm MS clamp
200 mm MS clamp (12 + 24 )
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) DI Pipe-29.914 cum 2) DI pipe (MS clamp) - 29.914 cum 3) HDPE Pipe (MS Clamp) - 105.012 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and reconditioning pump and repair works to Centrifugal Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to10 A
Upto 10 A to 20 A
Upto 20 to 30 A
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules For laying below GL including earth work
3core 10 Sq. mm Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm Copper cable
Supply and delivery of following Range 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps MCCB
250 Amps MCCB
Supply and delivery of following Range 3 Pole MCB Switch Miniature ciruit Breaker etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of following HRC Fuses etc., complete and as directed by TWAD Board officers
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
50 mm Sluice Valve
80 mm Sluice Valve
100mm Sluice Valve
125 mm Sluice Valve
150 mm Sluice Valve
200 mm Sluice Valve
80 mm CI NRV Valve
125 mm Sluice Valve
40 mm Double Air valve
50mm Air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.35 LL capacity of sump @ Mukkudal
0.45 LL capacity sump @ Alwarthulukarpatti
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.52 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 554.80 ML (1.52*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) DI pipes - 84.480 Cum 2) HDPE pipes with MS Clamp - 418.572 cum
Removing the burst P.V.C. /AC/CI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm DI K7 pipe
50mm HDPE Pipe
63mm HDPE Pipe
75mm HDPE Pipe
90mm HDPE Pipe
110mm HDPE Pipe
160mm HDPE Pipe
200 mm DI K7
50mm HDPE Pipe
63mm HDPE Pipe
75mm HDPE Pipe
90mm HDPE Pipe
110mm HDPE Pipe
160mm HDPE Pipe
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1) DI Pipe (Collar Leak) -29.914 cum 2) DI Pipe with MS Clampset - 29.914 cum 3) HDPE Pipe with MS Clampset - 105.012 cum
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe - 42.00 Kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe -42.00 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
DI pipe-96.00 Kg
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
DI pipe -12.00 hrs DI Pipe (MS Clampset )- 12.00 hrs HDPE pipe (MS Clampset) -48.00 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by the TWAD Board officers.
160 mm MS clamp
200 mm MS clamp (12 + 24 )
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers.
1) DI Pipe-29.914 cum 2) DI pipe (MS clamp) - 29.914 cum 3) HDPE Pipe (MS Clamp) - 105.012 cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and reconditioning pump and repair works to Centrifugal Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to10 A
Upto 10 A to 20 A
Upto 20 to 30 A
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by TWAD Board Officers.
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules For laying below GL including earth work
3core 10 Sq. mm Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm Copper cable
Supply and delivery of following Range 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps MCCB
250 Amps MCCB
Supply and delivery of following Range 3 Pole MCB Switch Miniature ciruit Breaker etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
Supply and delivery of following HRC Fuses etc., complete and as directed by TWAD Board officers
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
50 mm Sluice Valve
80 mm Sluice Valve
100mm Sluice Valve
125 mm Sluice Valve
150 mm Sluice Valve
200 mm Sluice Valve
80 mm CI NRV Valve
125 mm Sluice Valve
40 mm Double Air valve
50mm Air valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.35 LL capacity of sump @ Mukkudal
0.45 LL capacity sump @ Alwarthulukarpatti
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A13 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.53 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 145.750 ML (0.53*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst PVC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4KSC
110mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
PVC Coupler Fabricated
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 25 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by the TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by the TWAD Board officers. 20 A to 30 A
Preventer – Single Phasing Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any auxillary device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply. etc., complete and as directed by TWAD Board officers
Preventer – Dry Run Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
For 5 HP Starter - 2 Nos
For 15 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
10 Sq. mm flat type Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
5 KVAR Power capacitor 15 H.P Openwell submersible pumpset (Pumping from Headworks to Kavalkinaru sump) at Kodumudiyaru Dam Pump Room.
2 KVAR Power capacitor 5 H.P Openwell submersible pumpset (Pumping from Kavalkinaru sump to Kavalkinaru panchayats) at Kavalkinaru Pump Room.
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.30 LL capacity of sump @ Kavalkinaru
0.10 LL capacity of sump @ Hump point
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board officers
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.53 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 193.98 ML (0.53*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst PVC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4KSC
110mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
PVC Coupler Fabricated
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 25 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by the TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by the TWAD Board officers. 20 A to 30 A
Preventer – Single Phasing Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any auxillary device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply. etc., complete and as directed by TWAD Board officers
Preventer – Dry Run Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
For 5 HP Starter - 2 Nos
For 15 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
10 Sq. mm flat type Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
5 KVAR Power capacitor 15 H.P Openwell submersible pumpset (Pumping from Headworks to Kavalkinaru sump) at Kodumudiyaru Dam Pump Room.
2 KVAR Power capacitor 5 H.P Openwell submersible pumpset (Pumping from Kavalkinaru sump to Kavalkinaru panchayats) at Kavalkinaru Pump Room.
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.30 LL capacity of sump @ Kavalkinaru
0.10 LL capacity of sump @ Hump point
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board officers
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.53 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 193.45 ML (0.53*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst PVC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4KSC
110mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
PVC Coupler Fabricated
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 4 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 25 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by the TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by the TWAD Board officers. 20 A to 30 A
Preventer – Single Phasing Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any auxillary device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply. etc., complete and as directed by TWAD Board officers
Preventer – Dry Run Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).
For 5 HP Starter - 2 Nos
For 15 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
10 Sq. mm flat type Copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
5 KVAR Power capacitor 15 H.P Openwell submersible pumpset (Pumping from Headworks to Kavalkinaru sump) at Kodumudiyaru Dam Pump Room.
2 KVAR Power capacitor 5 H.P Openwell submersible pumpset (Pumping from Kavalkinaru sump to Kavalkinaru panchayats) at Kavalkinaru Pump Room.
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.30 LL capacity of sump @ Kavalkinaru
0.10 LL capacity of sump @ Hump point
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board officers
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A14 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.54 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 562.10 ML (1.54*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7 (Collar Leak)
200 mm DI Pipe K7 with MS Clamp
200 mm DI Pipe K7 with CID Joints
200 mm DI Pipe K7 with MJ Collar
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
200 mm DI Pipe K7
200 mm DI Pipe K7
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.
For 200mm MS Clamp
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
200mm dia DI pipe K7
Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
Same as EW Qty
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm dia DI pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
200 mm DI K7 Class
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
200mm dia DI pipe K7
Removing the burst D.I pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm dia DI pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200mm dia DI pipe K7
Supply and Delivery of MJ Collars as directed by TWAD Board officers
200mm dia DI pipe K7
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
32 Amps Contactor
110 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 25 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 25 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI NRV valve
125mm CI NRV valve
150mm CI NRV valve
200mm CI NRV valve
200mm CI Sluice valve
50mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
65mm Gate valve
80mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.90 LL capacity of sump @ Kansapuram (H.W)
0.50 LL capacity of sump @ Medical College
4.45 LL capacity of sump @ Medical Hospital
0.80 LL capacity of sump @ Medical Hospital
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Infiltration Well No-1
Infiltration Well No-2
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.54 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 563.64 ML (1.54*366)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7 (Collar Leak)
200 mm DI Pipe K7 with MS Clamp
200 mm DI Pipe K7 with CID Joints
200 mm DI Pipe K7 with MJ Collar
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
200 mm DI Pipe K7
200 mm DI Pipe K7
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.
For 200mm MS Clamp
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
200mm dia DI pipe K7
Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
Same as EW Qty
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm dia DI pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
200 mm DI K7 Class
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
200mm dia DI pipe K7
Removing the burst D.I pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm dia DI pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200mm dia DI pipe K7
Supply and Delivery of MJ Collars as directed by TWAD Board officers
200mm dia DI pipe K7
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
32 Amps Contactor
110 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 25 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 25 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI NRV valve
125mm CI NRV valve
150mm CI NRV valve
200mm CI NRV valve
200mm CI Sluice valve
50mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
65mm Gate valve
80mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.90 LL capacity of sump @ Kansapuram (H.W)
0.50 LL capacity of sump @ Medical College
4.45 LL capacity of sump @ Medical Hospital
0.80 LL capacity of sump @ Medical Hospital
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Infiltration Well No-1
Infiltration Well No-2
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.54 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 562.10 ML (1.54*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7 (Collar Leak)
200 mm DI Pipe K7 with MS Clamp
200 mm DI Pipe K7 with CID Joints
200 mm DI Pipe K7 with MJ Collar
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
200 mm DI Pipe K7
200 mm DI Pipe K7
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.
For 200mm MS Clamp
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
200mm dia DI pipe K7
Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
Same as EW Qty
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm dia DI pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
200 mm DI K7 Class
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
200mm dia DI pipe K7
Removing the burst D.I pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
200mm dia DI pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
200mm dia DI pipe K7
Supply and Delivery of MJ Collars as directed by TWAD Board officers
200mm dia DI pipe K7
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
32 Amps Contactor
110 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 25 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 25 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI NRV valve
125mm CI NRV valve
150mm CI NRV valve
200mm CI NRV valve
200mm CI Sluice valve
50mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
65mm Gate valve
80mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.90 LL capacity of sump @ Kansapuram (H.W)
0.50 LL capacity of sump @ Medical College
4.45 LL capacity of sump @ Medical Hospital
0.80 LL capacity of sump @ Medical Hospital
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Infiltration Well No-1
Infiltration Well No-2
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A15 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.59 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 162.250 ML (0.59*275)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
50mm PVC to 160mm PVC Pipes
50mm GI Pipes
Removing the burst P.V.C. Pipesfrom the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
160 mm PVC 6KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
160 mm PVC 6KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 6 KSC
Cutting the burst GI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
150mm GI (Medium)
Supply and delivery of the following sizes of GI pipes (medium) and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
150mm GI (Medium)
Threading of the following sizes of GI pipes (medium) and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
150mm GI (Medium)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3.00 core 70 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 70 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 70 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI Sluice valve
150mm CI Sluice valve
80mm CI NRV valve
150mm CI NRV valve
50mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.20 LL capacity Sump @ Central Prison
0.44 LL capacity Sump
0.15 LL capacity of sump @ central prison
0.55 LL capacity Sump
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.59 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 215.94 ML (0.59*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
50mm PVC to 160mm PVC Pipes
50mm GI Pipes
Removing the burst P.V.C. Pipesfrom the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
160 mm PVC 6KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
160 mm PVC 6KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 6 KSC
Cutting the burst GI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
150mm GI (Medium)
Supply and delivery of the following sizes of GI pipes (medium) and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
150mm GI (Medium)
Threading of the following sizes of GI pipes (medium) and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
150mm GI (Medium)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3.00 core 70 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 70 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 70 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI Sluice valve
150mm CI Sluice valve
80mm CI NRV valve
150mm CI NRV valve
50mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.20 LL capacity Sump @ Central Prison
0.44 LL capacity Sump
0.15 LL capacity of sump @ central prison
0.55 LL capacity Sump
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.59 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 215.35ML (0.59*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
50mm PVC to 160mm PVC Pipes
50mm GI Pipes
Removing the burst P.V.C. Pipesfrom the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
160 mm PVC 6KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
160 mm PVC 6KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 6 KSC
Cutting the burst GI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
150mm GI (Medium)
Supply and delivery of the following sizes of GI pipes (medium) and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
150mm GI (Medium)
Threading of the following sizes of GI pipes (medium) and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
150mm GI (Medium)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3.00 core 70 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 70 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 70 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI Sluice valve
150mm CI Sluice valve
80mm CI NRV valve
150mm CI NRV valve
50mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.20 LL capacity Sump @ Central Prison
0.44 LL capacity Sump
0.15 LL capacity of sump @ central prison
0.55 LL capacity Sump
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A16 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.79 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 288.350 ML (0.79*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
COLLAR LEAKS IN AC PIPES WITH LEADWOOL
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. AC Pipes of various Sizes
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Same as EW Qty
LEAKS IN AC PIPES WITH MS CLAMB
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.
For 150mm MS Clamp
For 200mm MS Clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Same as EW Qty
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes -148.523 cum AC pipes - 75.508 cum
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Removing the burst A.C Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
150 mm DI K7 Class
200 mm DI K7 Class
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
150mm Class 15 CID Joint
200mm Class 15 CID Joint
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 22.50HP open well submersible pump set (900 lpm x 68 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of submersible pumpset at Karunkulam (H.W) Infiltration Well - 1 No's
Rewinding of motor and reconditioning pump and repair works to 12.5HP centrifugal monobloc pumpset (380 lpm x 54 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal monobloc pumpset (250 lpm x 35 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal monobloc pumpset (360 lpm x 50 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
50 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).For 5 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3 core 95 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 95 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 95 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.80 KVAR Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
100 mm CI Sluice valve
CI NRV valve
100 mm CI NRV valve
200 mm CI NRV valve
Double airvalve
50 mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.50 LL capacity of sump @ serakulam
0.30 LL capacity of sump @ serakulam
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of leading channel for diverting water from water flowing area of the river to fare away infiltration wells
Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.79 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 289.140 ML (0.79*366)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
COLLAR LEAKS IN AC PIPES WITH LEADWOOL
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. AC Pipes of various Sizes
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Same as EW Qty
LEAKS IN AC PIPES WITH MS CLAMB
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.
For 150mm MS Clamp
For 200mm MS Clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Same as EW Qty
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes -148.523 cum AC pipes - 75.508 cum
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Removing the burst A.C Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
150 mm DI K7 Class
200 mm DI K7 Class
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
150mm Class 15 CID Joint
200mm Class 15 CID Joint
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 22.50HP open well submersible pump set (900 lpm x 68 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of submersible pumpset at Karunkulam (H.W) Infiltration Well - 1 No's
Rewinding of motor and reconditioning pump and repair works to 12.5HP centrifugal monobloc pumpset (380 lpm x 54 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal monobloc pumpset (250 lpm x 35 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal monobloc pumpset (360 lpm x 50 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
50 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).For 5 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3 core 95 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 95 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 95 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.80 KVAR Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
100 mm CI Sluice valve
CI NRV valve
100 mm CI NRV valve
200 mm CI NRV valve
Double airvalve
50 mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.50 LL capacity of sump @ serakulam
0.30 LL capacity of sump @ serakulam
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of leading channel for diverting water from water flowing area of the river to fare away infiltration wells
Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.79 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 288.35 ML (0.79*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
COLLAR LEAKS IN AC PIPES WITH LEADWOOL
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. AC Pipes of various Sizes
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Same as EW Qty
LEAKS IN AC PIPES WITH MS CLAMB
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack.
For 150mm MS Clamp
For 200mm MS Clamp
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. and as directed by the TWAD Board officers.
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Same as EW Qty
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. PVC Pipes of various Sizes -148.523 cum AC pipes - 75.508 cum
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160 mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Removing the burst A.C Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
150mm dia AC pipe class 15
200mm dia AC pipe class 15
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
150 mm DI K7 Class
200 mm DI K7 Class
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
150mm Class 15 CID Joint
200mm Class 15 CID Joint
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 22.50HP open well submersible pump set (900 lpm x 68 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of submersible pumpset at Karunkulam (H.W) Infiltration Well - 1 No's
Rewinding of motor and reconditioning pump and repair works to 12.5HP centrifugal monobloc pumpset (380 lpm x 54 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal monobloc pumpset (250 lpm x 35 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal monobloc pumpset (360 lpm x 50 m) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal monobloc pumpset at Seraikulam Sump - 1 No's
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
50 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).For 5 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3 core 95 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 95 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 95 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
250 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of HRC -Fuses at higher end
250 Amps -500 Amps
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.80 KVAR Power capacitor at various pumprooms
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
100 mm CI Sluice valve
CI NRV valve
100 mm CI NRV valve
200 mm CI NRV valve
Double airvalve
50 mm Double airvalve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.50 LL capacity of sump @ serakulam
0.30 LL capacity of sump @ serakulam
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Formation of leading channel for diverting water from water flowing area of the river to fare away infiltration wells
Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A17 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.14 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 416.100 ML (1.14*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
50mm to 200mm PVC Pipes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 6KSC
160mm PVC 4KSC
200 mm PVC 6KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 6 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 6 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).For 3 HP Starter
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
12 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 25 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 25 Sq. mm aluminium cable
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI Sluice valve
80mm CI NRV valve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.10 LL capacity of sump @ Rajavallipuram
1.05 LL capacity of sump @ PALAMADAI
0.80 LL capacity of sump @ SEEVALAPERI
0.70 LL capacity of sump @ veppankulam
0.50 LL capacity of sump @ Seliyanallur
0.45 LL capacity of sump @ kottayadivillaku
0.40 LL capacity of sump @ Gangaikondan
0.35 LL capacity of sump @ ithikulam
0.30 LL capacity of sump @ ithikulam
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete.
Infiltration Well No-1
Infiltration Well No-2
Formation of leading channel for diverting water from water flowing area of the river to fare away infiltration wells
Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.14 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 417.24 ML (1.14*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
50mm to 200mm PVC Pipes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 6KSC
160mm PVC 4KSC
200 mm PVC 6KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 6 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 6 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).For 3 HP Starter
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
12 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 25 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 25 Sq. mm aluminium cable
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI Sluice valve
80mm CI NRV valve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.10 LL capacity of sump @ Rajavallipuram
1.05 LL capacity of sump @ PALAMADAI
0.80 LL capacity of sump @ SEEVALAPERI
0.70 LL capacity of sump @ veppankulam
0.50 LL capacity of sump @ Seliyanallur
0.45 LL capacity of sump @ kottayadivillaku
0.40 LL capacity of sump @ Gangaikondan
0.35 LL capacity of sump @ ithikulam
0.30 LL capacity of sump @ ithikulam
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete.
Infiltration Well No-1
Infiltration Well No-2
Formation of leading channel for diverting water from water flowing area of the river to fare away infiltration wells
Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.14 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 416.10 ML (1.14*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
50mm to 200mm PVC Pipes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
200mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 6KSC
160mm PVC 4KSC
200 mm PVC 6KSC
Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 6 KSC
160 mm PVC Coupler Fabricated 4 KSC
200 mm PVC Coupler Fabricated 6 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947 and IEC60947-1 suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately).For 3 HP Starter
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
25 Amps Contactor
12 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking.
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 25 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 25 Sq. mm aluminium cable
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80mm CI Sluice valve
80mm CI NRV valve
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50mm Gate valve
65mm Gate valve
80mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.10 LL capacity of sump @ Rajavallipuram
1.05 LL capacity of sump @ PALAMADAI
0.80 LL capacity of sump @ SEEVALAPERI
0.70 LL capacity of sump @ veppankulam
0.50 LL capacity of sump @ Seliyanallur
0.45 LL capacity of sump @ kottayadivillaku
0.40 LL capacity of sump @ Gangaikondan
0.35 LL capacity of sump @ ithikulam
0.30 LL capacity of sump @ ithikulam
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete.
Infiltration Well No-1
Infiltration Well No-2
Formation of leading channel for diverting water from water flowing area of the river to fare away infiltration wells
Earth work deploying earth moving machineries for desliting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc, complete. Having width up of 3m
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A18 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the year 2026-2027 ( 01.04.2026 to 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.36 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 496.400 ML (1.36*365)
Attending Collar Leaks in the Pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. CI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers CI Pipe of various sizes
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers. CI Pipe of various sizes
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc.,rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. CI Pipe of various sizes
Removing the burst C.I. pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
200 mm CI pipes
250 mm CI Pipes
300 mm CI Pipes
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
300 mm DI K7 Class
200 mm DI K7 Class
250 mm DI K7 Class
Supply of CID Joint as per IS 8794/1988 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
200mm CID Joint
250mm CID Joint
300mm CID Joint
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 60HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 60 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 140 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by the TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by the TWAD Board officers.
Upto 5 A
Preventer – Dry Run Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by the TWAD Board officers. 5 HP Starter
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by the TWAD Board officers. For 60 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable For laying below GL including earth work
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable For laying below GL including earth work
10 Sq. mm flat type Copper cable
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
200 mm CI Sluice valve
200 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI NRV valve
80mm Double air valve
50 mm Double air valve
40 mm Double air valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.45 capacity
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc., complete and as directed by TWAD Board officers
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the year 2027-2028 ( 01.04.2027 to 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.36 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 497.76 ML (1.36*366)
Attending Collar Leaks in the Pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. CI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers CI Pipe of various sizes
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers. CI Pipe of various sizes
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc.,rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. CI Pipe of various sizes
Removing the burst C.I. pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
200 mm CI pipes
250 mm CI Pipes
300 mm CI Pipes
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
300 mm DI K7 Class
200 mm DI K7 Class
250 mm DI K7 Class
Supply of CID Joint as per IS 8794/1988 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
200mm CID Joint
250mm CID Joint
300mm CID Joint
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 60HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 60 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 140 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by the TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by the TWAD Board officers.
Upto 5 A
Preventer – Dry Run Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by the TWAD Board officers. 5 HP Starter
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by the TWAD Board officers. For 60 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable For laying below GL including earth work
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable For laying below GL including earth work
10 Sq. mm flat type Copper cable
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
200 mm CI Sluice valve
200 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI NRV valve
80mm Double air valve
50 mm Double air valve
40 mm Double air valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.45 capacity
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc., complete and as directed by TWAD Board officers
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the year 2028-2029 ( 01.04.2028 to 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.36 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 496.40 ML (1.36*365)
Attending Collar Leaks in the Pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. CI Pipe of various sizes
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers CI Pipe of various sizes
Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers CI Pipe of various sizes
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers. CI Pipe of various sizes
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc.,rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. CI Pipe of various sizes
Removing the burst C.I. pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
200 mm CI pipes
250 mm CI Pipes
300 mm CI Pipes
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
300 mm DI K7 Class
200 mm DI K7 Class
250 mm DI K7 Class
Supply of CID Joint as per IS 8794/1988 inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
200mm CID Joint
250mm CID Joint
300mm CID Joint
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 60HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 60 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 140 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by the TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by the TWAD Board officers.
Upto 5 A
Preventer – Dry Run Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board officers
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by the TWAD Board officers. 5 HP Starter
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by the TWAD Board officers. For 60 HP Starter
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable For laying below GL including earth work
10 Sq. mm flat type Copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable For laying below GL including earth work
10 Sq. mm flat type Copper cable
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.etc complete and as directed by TWAD Board officers
Attending repair ,rectification and reconditioning CI Sluice / CI NRV/ Double Air valve valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
200 mm CI Sluice valve
200 mm CI NRV valve
150 mm CI Sluice valve
150 mm CI NRV valve
80mm Double air valve
50 mm Double air valve
40 mm Double air valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.45 capacity
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc., complete and as directed by TWAD Board officers
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A19 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.93 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1069.45 ML (2.93*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i)PVC Pipes of various sizes - 119.438 Cum ii)AC/DI pipes of various sizes - 51.040 Cum
Removing the burst P.V.C./AC/DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90 mm PVC 4 KSC
110mm PVC 4KSC
200 mm AC pipe
250mm AC pipe
250mm DI pipe K7 class
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90 mm PVC 4 KSC
110mm PVC 4KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
200 mm DI pipe K7
250 mm DI pipe K7
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes and transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
273 x 5 mm thick MS pipes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1)AC/DI Pipe of various sizes - 174.553 cum 2)AC/DI Pipe of various sizes - 95.886 cum
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 200 mm dia AC Class 15 Pipe - 72 lit ii) 250 mm dia AC Class 15 Pipe - 75 lit iii)250 mm dia DI K7 Class - 54 lit
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 200 mm dia AC Class 15 Pipe - 144 kg ii) 250 mm dia AC Class 15 Pipe - 150 kg iii)250 mm dia DI K7 Class - 108 Kg
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i) 200 mm dia AC Class 15 Pipe - 72 kg ii) 250 mm dia AC Class 15 Pipe - 75 kg iii)250 mm dia DI K7 Class - 54 Kg
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
i) 200 mm dia AC Class 15 Pipe - 24 hrs ii) 250 mm dia AC Class 15 Pipe - 50 hrs iii)250 mm dia DI K7 Class - 36 hrs iv 250 mm dia AC and DI pipe - 74 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
AC/DI Pipes of various sizes - (174.553+95.886) cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set including cost of all material, conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 60 HP Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Rewinding of motor and and repair works to vertical turbine /HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
vertical turbine motor
Repair and Reconditoning works in various capacity of Centrifugal Monobloc Pump set including cost of all material labour, conveyance, labour charges for removing and re-erection of etc as directed by TWAD Board officers
2 HP atSankarnagar EB colony
3 HP at Sankarnagar Pandarakulam
5 HP at Thenkalam
2 HP at Thalaiyuthu
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately) - Upto 5 HP
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc complete directed by the TWAD Board officers
Upto 5A-10A
Upto 10A-20A
Upto 110A-150A
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps MCCB
250 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
250 Amps to 500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
250 mm CI Sluice valve
200 mm CI Sluice valve
150 mm CI Sluice valve
200 mm CI Sluice valve for Scour
CI NRV valve
250 mm CI NRV valve
150 mm CI NRV valve
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm copper cable
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm Gate valve
100 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.50 LL capacity of sump @ Palamadai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.93 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1072.38 ML (2.93*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i)PVC Pipes of various sizes - 119.438 Cum ii)AC/DI pipes of various sizes - 51.040 Cum
Removing the burst P.V.C./AC/DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90 mm PVC 4 KSC
110mm PVC 4KSC
200 mm AC pipe
250mm AC pipe
250mm DI pipe K7 class
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90 mm PVC 4 KSC
110mm PVC 4KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
200 mm DI pipe K7
250 mm DI pipe K7
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes and transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
273 x 5 mm thick MS pipes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1)AC/DI Pipe of various sizes - 174.553 cum 2)AC/DI Pipe of various sizes - 95.886 cum
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 200 mm dia AC Class 15 Pipe - 72 lit ii) 250 mm dia AC Class 15 Pipe - 75 lit iii)250 mm dia DI K7 Class - 54 lit
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 200 mm dia AC Class 15 Pipe - 144 kg ii) 250 mm dia AC Class 15 Pipe - 150 kg iii)250 mm dia DI K7 Class - 108 Kg
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i) 200 mm dia AC Class 15 Pipe - 72 kg ii) 250 mm dia AC Class 15 Pipe - 75 kg iii)250 mm dia DI K7 Class - 54 Kg
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
i) 200 mm dia AC Class 15 Pipe - 24 hrs ii) 250 mm dia AC Class 15 Pipe - 50 hrs iii)250 mm dia DI K7 Class - 36 hrs iv 250 mm dia AC and DI pipe - 74 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
AC/DI Pipes of various sizes - (174.553+95.886) cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set including cost of all material, conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 60 HP Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Rewinding of motor and and repair works to vertical turbine /HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
vertical turbine motor
Repair and Reconditoning works in various capacity of Centrifugal Monobloc Pump set including cost of all material labour, conveyance, labour charges for removing and re-erection of etc as directed by TWAD Board officers
2 HP atSankarnagar EB colony
3 HP at Sankarnagar Pandarakulam
5 HP at Thenkalam
2 HP at Thalaiyuthu
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately) - Upto 5 HP
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc complete directed by the TWAD Board officers
Upto 5A-10A
Upto 10A-20A
Upto 110A-150A
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps MCCB
250 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
250 Amps to 500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
250 mm CI Sluice valve
200 mm CI Sluice valve
150 mm CI Sluice valve
200 mm CI Sluice valve for Scour
CI NRV valve
250 mm CI NRV valve
150 mm CI NRV valve
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm copper cable
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm Gate valve
100 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.50 LL capacity of sump @ Palamadai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.93 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 1069.45 ML (2.93*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i)PVC Pipes of various sizes - 119.438 Cum ii)AC/DI pipes of various sizes - 51.040 Cum
Removing the burst P.V.C./AC/DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90 mm PVC 4 KSC
110mm PVC 4KSC
200 mm AC pipe
250mm AC pipe
250mm DI pipe K7 class
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90 mm PVC 4 KSC
110mm PVC 4KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
200 mm DI pipe K7
250 mm DI pipe K7
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes and transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
273 x 5 mm thick MS pipes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1)AC/DI Pipe of various sizes - 174.553 cum 2)AC/DI Pipe of various sizes - 95.886 cum
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 200 mm dia AC Class 15 Pipe - 72 lit ii) 250 mm dia AC Class 15 Pipe - 75 lit iii)250 mm dia DI K7 Class - 54 lit
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) 200 mm dia AC Class 15 Pipe - 144 kg ii) 250 mm dia AC Class 15 Pipe - 150 kg iii)250 mm dia DI K7 Class - 108 Kg
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i) 200 mm dia AC Class 15 Pipe - 72 kg ii) 250 mm dia AC Class 15 Pipe - 75 kg iii)250 mm dia DI K7 Class - 54 Kg
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
i) 200 mm dia AC Class 15 Pipe - 24 hrs ii) 250 mm dia AC Class 15 Pipe - 50 hrs iii)250 mm dia DI K7 Class - 36 hrs iv 250 mm dia AC and DI pipe - 74 hrs
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
AC/DI Pipes of various sizes - (174.553+95.886) cum
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set including cost of all material, conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 60 HP Vertical turbine Pump set including cost of all material (excluding bronze impeller, SS shaft ,MS column pipe) conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Rewinding of motor and and repair works to vertical turbine /HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
vertical turbine motor
Repair and Reconditoning works in various capacity of Centrifugal Monobloc Pump set including cost of all material labour, conveyance, labour charges for removing and re-erection of etc as directed by TWAD Board officers
2 HP atSankarnagar EB colony
3 HP at Sankarnagar Pandarakulam
5 HP at Thenkalam
2 HP at Thalaiyuthu
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammeter, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, including the capacitor(the cost of capacitor is to be taken separately) - Upto 5 HP
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc complete directed by the TWAD Board officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc complete directed by the TWAD Board officers
Upto 5A-10A
Upto 10A-20A
Upto 110A-150A
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps MCCB
250 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
250 Amps to 500 Amps
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
250 mm CI Sluice valve
200 mm CI Sluice valve
150 mm CI Sluice valve
200 mm CI Sluice valve for Scour
CI NRV valve
250 mm CI NRV valve
150 mm CI NRV valve
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3core 10 Sq. mm copper cable
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm Gate valve
100 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
1.50 LL capacity of sump @ Palamadai
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A20 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.97 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 354.050 ML (0.97*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various sizes - 269.227 Cum ii) AC / DI pipes of various sizes - 44.436 Cum
Removing the burst P.V.C./AC/DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75 mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
150 mm DI pipe K7
250 mm DI pipe K7
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes and transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
168.3 x 4.5 mm thick MS pipes
219.1 x 4.5 mm thick MS pipes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) AC/DI Pipes of various sizes - 190.030 Cum ii) AC,CI/DI Pipes of varius sizes - 71.396 Cum
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
i) 150 mm AC Pipe - 36+15 hrs ii) 200 mm AC Pipe - 36 +15 hrs
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i)150 mm AC Pipe - 180 kg ii) 200 mm AC Pipe - 216 kg
Supply and delivery of Lead wool for leak work AC. pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i)150 mm AC Pipe - 72 kg ii) 200 mm AC Pipe - 108 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i)150 mm AC Pipe - 108 lit ii) 200 mm AC Pipe - 108 lit
Supply and delivery of Leak Arresting Flexible 150 mm MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
Supply and delivery of Leak Arresting Flexible 200 mm MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
i) AC/ CI Pipes of various sizes - (190.030+71.396)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Electro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC centrifugal Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC centrifugal Motor including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditoning works in various capacity of Centrifugal Monobloc Pump set including cost of all material labour, conveyance, labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to 10 A
Upto 10 A to 20 A
Upto 30 A to 50 A
Upto 35 A to 50 A
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by TWAD Board Officers 25 HP.
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
125 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
63 Amps MCB Isolater
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
250 Amps to 500 Amps
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 16 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 16 Sq. mm copper cable
Jointing the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 16 Sq. mm copper cable
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI SLUICE valve
100mm CI Sluice Valve for Scour
80mm CI Sluice Valve for Scour
CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.60 LL capacity of sump @ Sengulam Villaku
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete having depth of 3 m etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.97 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 355.02 ML (0.97*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various sizes - 269.227 Cum ii) AC / DI pipes of various sizes - 44.436 Cum
Removing the burst P.V.C./AC/DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75 mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
150 mm DI pipe K7
250 mm DI pipe K7
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes and transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
168.3 x 4.5 mm thick MS pipes
219.1 x 4.5 mm thick MS pipes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) AC/DI Pipes of various sizes - 190.030 Cum ii) AC,CI/DI Pipes of varius sizes - 71.396 Cum
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
i) 150 mm AC Pipe - 36+15 hrs ii) 200 mm AC Pipe - 36 +15 hrs
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i)150 mm AC Pipe - 180 kg ii) 200 mm AC Pipe - 216 kg
Supply and delivery of Lead wool for leak work AC. pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i)150 mm AC Pipe - 72 kg ii) 200 mm AC Pipe - 108 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i)150 mm AC Pipe - 108 lit ii) 200 mm AC Pipe - 108 lit
Supply and delivery of Leak Arresting Flexible 150 mm MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
Supply and delivery of Leak Arresting Flexible 200 mm MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
i) AC/ CI Pipes of various sizes - (190.030+71.396)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Electro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC centrifugal Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC centrifugal Motor including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditoning works in various capacity of Centrifugal Monobloc Pump set including cost of all material labour, conveyance, labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to 10 A
Upto 10 A to 20 A
Upto 30 A to 50 A
Upto 35 A to 50 A
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by TWAD Board Officers 25 HP.
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
125 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
63 Amps MCB Isolater
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
250 Amps to 500 Amps
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 16 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 16 Sq. mm copper cable
Jointing the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 16 Sq. mm copper cable
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI SLUICE valve
100mm CI Sluice Valve for Scour
80mm CI Sluice Valve for Scour
CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.60 LL capacity of sump @ Sengulam Villaku
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete having depth of 3 m etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.97 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 354.05 ML (0.97*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) PVC Pipes of various sizes - 269.227 Cum ii) AC / DI pipes of various sizes - 44.436 Cum
Removing the burst P.V.C./AC/DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75 mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4 KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
150 mm DI pipe K7
250 mm DI pipe K7
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes and transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
168.3 x 4.5 mm thick MS pipes
219.1 x 4.5 mm thick MS pipes
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
i) AC/DI Pipes of various sizes - 190.030 Cum ii) AC,CI/DI Pipes of varius sizes - 71.396 Cum
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
i) 150 mm AC Pipe - 36+15 hrs ii) 200 mm AC Pipe - 36 +15 hrs
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i)150 mm AC Pipe - 180 kg ii) 200 mm AC Pipe - 216 kg
Supply and delivery of Lead wool for leak work AC. pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
i)150 mm AC Pipe - 72 kg ii) 200 mm AC Pipe - 108 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i)150 mm AC Pipe - 108 lit ii) 200 mm AC Pipe - 108 lit
Supply and delivery of Leak Arresting Flexible 150 mm MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
Supply and delivery of Leak Arresting Flexible 200 mm MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete. And as directed by TWAD Board officers
i) AC/ CI Pipes of various sizes - (190.030+71.396)
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Electro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC centrifugal Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity HSC centrifugal Motor including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Repair and Reconditoning works in various capacity of Centrifugal Monobloc Pump set including cost of all material labour, conveyance, labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Upto 5 A to 10 A
Upto 10 A to 20 A
Upto 30 A to 50 A
Upto 35 A to 50 A
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil inclusive of handling charges etc., complete and as directed by TWAD Board Officers 25 HP.
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
125 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
63 Amps MCB Isolater
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
250 Amps to 500 Amps
Attending cable fault by replacing the cable
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 16 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 16 Sq. mm copper cable
Jointing the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 16 Sq. mm copper cable
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI SLUICE valve
100mm CI Sluice Valve for Scour
80mm CI Sluice Valve for Scour
CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.60 LL capacity of sump @ Sengulam Villaku
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete having depth of 3 m etc., complete and as directed by TWAD Board officers.
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A21 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.63 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 229.95 ML (0.63*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For AC Pipe of various sizes
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers. 150 mm AC Pipe
Supply and delivery of Cement etc. complete and as directed by TWAD Board Officers - 150 mm AC Pipe class 15 pipe
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers - 150 mm dia AC class 15 pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers For AC Pipes of various sizes
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers. - 150 mm dia AC class 15 pipe
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80 mm CI SLUICE
80mm CI NRV Valve
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Supply and delivery of 25 Amps\440V Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc
Supply and delivery of 40 Amps\440V Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63-100 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers (10 KVAR power capcitor at Seevalaperi Head works)
Supply and delivery of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc
For 10.00 HP Starter - 2 Nos
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.30 LL capacity Sump @ Burkitmanagar
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.63 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 230.58 ML (0.63*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For AC Pipe of various sizes
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers. 150 mm AC Pipe
Supply and delivery of Cement etc. complete and as directed by TWAD Board Officers - 150 mm AC Pipe class 15 pipe
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers - 150 mm dia AC class 15 pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers For AC Pipes of various sizes
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers. - 150 mm dia AC class 15 pipe
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80 mm CI SLUICE
80mm CI NRV Valve
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Supply and delivery of 25 Amps\440V Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc
Supply and delivery of 40 Amps\440V Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63-100 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers (10 KVAR power capcitor at Seevalaperi Head works)
Supply and delivery of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc
For 10.00 HP Starter - 2 Nos
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.30 LL capacity Sump @ Burkitmanagar
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.63 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 229.95 ML (0.63*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For AC Pipe of various sizes
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers. 150 mm AC Pipe
Supply and delivery of Cement etc. complete and as directed by TWAD Board Officers - 150 mm AC Pipe class 15 pipe
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers - 150 mm dia AC class 15 pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers For AC Pipes of various sizes
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers. - 150 mm dia AC class 15 pipe
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Attending repair ,rectification and reconditioning CI Sluice/ CI NRV valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
80 mm CI SLUICE
80mm CI NRV Valve
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 50 Sq. mm aluminium cable
3.00 core 25 Sq. mm aluminium cable
Supply and delivery of 25 Amps\440V Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc
Supply and delivery of 40 Amps\440V Electro magnetic contactors of suitable for starter in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63-100 Amps MCCB
Supply and delivery of following Range AMPS 3 Pole MCB Switch (Miniature circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board at higher end
6 Amps to 32 Amps MCB
Supply and delivery of following Range AMPS HRC fuses, complete and as directed by TWAD Board officers
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers (10 KVAR power capcitor at Seevalaperi Head works)
Supply and delivery of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
Supply and delivery of Fully Automatic Auto Transformer Starter suitable for the motor offered. Floor mounting type air/ oil cooled Auto Transformer Starter with tapings at 50%, 65%, 80%, housed in robust steel chamber with arc and main contacts confirming to IS 8544 Part IV and as amended therafter for operation in AC three Phase 50 Hz (+/- 5%), 415V (+/- 10%) with the following components, under voltage release with no volt coil, over load relay with dash pot arrangements, single phasing preventor, LED ON/ OFF switches, Mounted Ammeter, Earth leakage relay, contactor assembly suitable for next standard KW rating, in coming and out going cable entry provisions, transformer tank including first filling of oil etc
For 10.00 HP Starter - 2 Nos
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
0.30 LL capacity Sump @ Burkitmanagar
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A22 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.68 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 978.2ML (2.68*275)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For DI Pipe of various sizes
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
MS CLAMB
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
200 mm DI Pipe
250 mm DI Pipe
300 mm DI Pipe
MS CLAMB
200 mm DI Pipe
250 mm DI Pipe
300 mm DI Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers For DI Pipes of various sizes
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
MS CLAMB
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for Burst rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For DI Pipe of various sizes
CID JOINTS
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
MJ COLLAR
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 30 HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 30 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 35 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 35 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 35 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers (80KVAR)
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
50mm CI NRV valve
80mm CI NRV valve
125mm CI NRV valve
150mm CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.45 LL capacity of sump @ Thirumalaikolundhupuram
2.45 LL capacity of sump @ Achimadam
0.20 LL capacity of sump @ Muthoor
0.10 LL capacity of sump @ Etteri
0.30 LL capacity of sump @ Sivanthipatti
0.30 LL capacity of sump @ Rediyarpatti
0.10 LL capacity of sump @ Munnerpallam
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Infiltration Well No-1
Infiltration Well No-2
Infiltration Well No-3
Infiltration Well No-4
Infiltration Well No-5
Cost of Chemicals
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.68 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 980.88ML (2.68*366)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For DI Pipe of various sizes
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
MS CLAMB
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
200 mm DI Pipe
250 mm DI Pipe
300 mm DI Pipe
MS CLAMB
200 mm DI Pipe
250 mm DI Pipe
300 mm DI Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers For DI Pipes of various sizes
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
MS CLAMB
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for Burst rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For DI Pipe of various sizes
CID JOINTS
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
MJ COLLAR
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 30 HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 30 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 35 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 35 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 35 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers (80KVAR)
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
50mm CI NRV valve
80mm CI NRV valve
125mm CI NRV valve
150mm CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.45 LL capacity of sump @ Thirumalaikolundhupuram
2.45 LL capacity of sump @ Achimadam
0.20 LL capacity of sump @ Muthoor
0.10 LL capacity of sump @ Etteri
0.30 LL capacity of sump @ Sivanthipatti
0.30 LL capacity of sump @ Rediyarpatti
0.10 LL capacity of sump @ Munnerpallam
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Infiltration Well No-1
Infiltration Well No-2
Infiltration Well No-3
Infiltration Well No-4
Infiltration Well No-5
Cost of Chemicals
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.68 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 978.20 ML (2.68*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For DI Pipe of various sizes
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
MS CLAMB
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
Supply and delivery of Lead wool for leak work Pipe line inculding loading, unloading transporting charges etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of Leak Arresting Flexible MS Clamps. Suitable width of the clamps to be decided by the engineer incharge at site depending on the nature of pipe crack. etc., complete and as directed by the TWAD Board officers.
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by the TWAD Board officers.
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
200 mm DI Pipe
250 mm DI Pipe
300 mm DI Pipe
MS CLAMB
200 mm DI Pipe
250 mm DI Pipe
300 mm DI Pipe
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers For DI Pipes of various sizes
COLLAR LEAKS IN DI PIPES WITH LEADWOOL
MS CLAMB
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50 mm PVC 6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50 mm PVC6 KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
160mm PVC 4KSC
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
160 mm PVC Coupler Fabricated 4 KSC
Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for Burst rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For DI Pipe of various sizes
CID JOINTS
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
MJ COLLAR
(i)200 mm DI Pipe K7 (i)250 mm DI Pipe K7 (i)300 mm DI Pipe K7
Removing the burst D.I Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of the following sizes of DUCTILE IRON PIPES of CLASS K7 confirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board Officers
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
Supply and delivery of following size of CID joints as per IS specification at site of work etc.complete
CID JOINTS
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
MJ COLLAR
200 mm DI Pipe K7
250 mm DI Pipe K7
300 mm DI Pipe K7
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Rewinding of motor and and repair works to 30 HP HSC motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Repair and Reconditonig works in various capacity 30 HP HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
12 Amps Contactor
18 Amps Contactor
25 Amps Contactor
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers.
3.00 core 35 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3.00 core 35 Sq. mm aluminium cable
Jointing the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3.00 core 35 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
63 Amps to 100 Amps 3 Pole MCCB Switch
Supply and delivery of following Range of 3 Pole MCB Switch (Miniature circuit breaker ) to control EB supply from E.B Pole to Main Panel Board at higher end
Supply and delivery of following Range of HRC -Fuses at higher end
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers (80KVAR)
Attending repair ,rectification and reconditioning CI Sluice valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
50mm CI NRV valve
80mm CI NRV valve
125mm CI NRV valve
150mm CI NRV valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
2.45 LL capacity of sump @ Thirumalaikolundhupuram
2.45 LL capacity of sump @ Achimadam
0.20 LL capacity of sump @ Muthoor
0.10 LL capacity of sump @ Etteri
0.30 LL capacity of sump @ Sivanthipatti
0.30 LL capacity of sump @ Rediyarpatti
0.10 LL capacity of sump @ Munnerpallam
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Infiltration Well No-1
Infiltration Well No-2
Infiltration Well No-3
Infiltration Well No-4
Infiltration Well No-5
Cost of Chemicals
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A23 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 9.16 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 3343.40.00 ML (9.16*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. Ist Depth of 2m
SS clampset Leak i) AC pipe with CID joint - 262.014 cum ii)PSC Pipe of various sizes - 301.743 cum
Collar Leak i) AC Pipe of various sizes - 712.505 cum ii)PSC Pipe of various sizes -2837.720 cum
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
300 mm AC Class 15 Pipe
250 mm AC Class 15 Pipe
200 mm AC Class 15 Pipe
150 mm AC Class 15 Pipe
Supply and delivery of Leak arresting Flexible MS Clamps inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
450 mm NB PSC
400 mm NB PSC
350 mm NB PSC
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers for Collar Leak
i) AC Pipe of various sizes - 935 kg ii) PSC Pipe of various sizes - 2530 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers for Collar Leak
i) AC Pipe of various sizes - 935 litre ii) PSC Pipe of various sizes -2440 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) AC Pipe of various sizes - 1060 kg ii) PSC Pipe of various sizes - 2810 kg
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
SS clampset Leak i) AC Pipe with CID joint- 590 hrs ii) PSC Pipe of various sizes -640 hrs
Collar Leak i) AC Pipe of various sizes - 935 hrs ii) PSC Pipe of various sizes -2250 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
SS clampset Leak i) AC pipe with CID Joint -262.014 cum ii) PSC Pipe of various sizes - 301.743 cum
Collar Leak i) AC Pipe of various sizes - 712.505 cum ii) PSC Pipe of various sizes - 2837.720 cum
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. Ist Depth of 2m
i) PVC Pipes of various sizes - 766.069 cum ii) AC Pipes of various sizes - 209.712 cum iii) PSC Pipes of various sizes - 189.693 cum
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
PVC Coupler Fabricated
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
300 mm DI K7 Class
250 mm DI K7 Class
200 mm DI K7 Class
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
355.6 mm x 4 mm thick MS Pipe
406.4 mm x 4 mm thick MS Pipe
457 mm x 4 mm thick MS Pipe
Supply and Delivery of MJ Collars inclusive of transportation charges anywhere in Tamilnadu etc complete and as directed by TWAD Board officers
200mm MJ Collars
250mm MJ Collars
300mm MJ Collars
350mm MJ Collars
400mm MJ Collars
450mm MJ Collars
Removing the burst PSC /PVC/A.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
350 mm PSC Pipes of various classes
400 mm PSC Pipes of various classes
450 mm PSC Pipes of various classes
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
HSC Pump set
Centrifugal Pump set
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc. complete and as directed by TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc. complete and as directed by TWAD Board officers.
Upto 5A-10A
Upto 10A-20A
Upto 20A-30A
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole ACB & MCCB Switch (Air circuit breakers & Moulted case circuit breakers) inclusive of handling charges, F.O.R destination etc. complete and as directed by TWAD Board officers. to control EB supply from E.B Pole to Main Panel Board
4 Pole MCCB
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Double air valve
CI Scour valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Power Capacitor
Repair and reconditioning of starter
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by the TWAD Board officers.
5 HP Starter
3 HP Starter
2 HP Starter
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
Cheranmahadevi (Headworks)3.00 LL
Kanganakulam 3.00 LL
Pulavankudiyiruppu3.00 LL
Mavadi 2.00 LL
Govindaperi1.65 LL
Padmaneri2.00 LL
SN Pallivasal 2.00LL
Kalakadu0.30LL
Rajapudur0.60LL
Madapppuram 1.00 LL
Kannanallur0.60LL
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work excavation deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete and as directed by TWAD Board officers.
TRANSFORMER
Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as rected by TWAD Board Officers
Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 433KV LV Bushing copper rod to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of paint to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for hot air chamber treatment for IR value Improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TwAD Board Officers
Charges for transformer tank cleaning and painting work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
Hire charges for Mobile crane used for unloading of Transformer from Bed to loading into Vehicle for moving to Work Shop & After Repair work, Placing back in Transformer Bed
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 9.16 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 3352.56 ML (9.16*366)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. Ist Depth of 2m
SS clampset Leak i) AC pipe with CID joint - 262.014 cum ii)PSC Pipe of various sizes - 301.743 cum
Collar Leak i) AC Pipe of various sizes - 712.505 cum ii)PSC Pipe of various sizes -2837.720 cum
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
300 mm AC Class 15 Pipe
250 mm AC Class 15 Pipe
200 mm AC Class 15 Pipe
150 mm AC Class 15 Pipe
Supply and delivery of Leak arresting Flexible MS Clamps inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
450 mm NB PSC
400 mm NB PSC
350 mm NB PSC
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers for Collar Leak
i) AC Pipe of various sizes - 935 kg ii) PSC Pipe of various sizes - 2530 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers for Collar Leak
i) AC Pipe of various sizes - 935 litre ii) PSC Pipe of various sizes -2440 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) AC Pipe of various sizes - 1060 kg ii) PSC Pipe of various sizes - 2810 kg
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
SS clampset Leak i) AC Pipe with CID joint- 590 hrs ii) PSC Pipe of various sizes -640 hrs
Collar Leak i) AC Pipe of various sizes - 935 hrs ii) PSC Pipe of various sizes -2250 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
SS clampset Leak i) AC pipe with CID Joint -262.014 cum ii) PSC Pipe of various sizes - 301.743 cum
Collar Leak i) AC Pipe of various sizes - 712.505 cum ii) PSC Pipe of various sizes - 2837.720 cum
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. Ist Depth of 2m
i) PVC Pipes of various sizes - 766.069 cum ii) AC Pipes of various sizes - 209.712 cum iii) PSC Pipes of various sizes - 189.693 cum
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
PVC Coupler Fabricated
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
300 mm DI K7 Class
250 mm DI K7 Class
200 mm DI K7 Class
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
355.6 mm x 4 mm thick MS Pipe
406.4 mm x 4 mm thick MS Pipe
457 mm x 4 mm thick MS Pipe
Supply and Delivery of MJ Collars inclusive of transportation charges anywhere in Tamilnadu etc complete and as directed by TWAD Board officers
200mm MJ Collars
250mm MJ Collars
300mm MJ Collars
350mm MJ Collars
400mm MJ Collars
450mm MJ Collars
Removing the burst PSC /PVC/A.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
350 mm PSC Pipes of various classes
400 mm PSC Pipes of various classes
450 mm PSC Pipes of various classes
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
HSC Pump set
Centrifugal Pump set
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc. complete and as directed by TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc. complete and as directed by TWAD Board officers.
Upto 5A-10A
Upto 10A-20A
Upto 20A-30A
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole ACB & MCCB Switch (Air circuit breakers & Moulted case circuit breakers) inclusive of handling charges, F.O.R destination etc. complete and as directed by TWAD Board officers. to control EB supply from E.B Pole to Main Panel Board
4 Pole MCCB
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Double air valve
CI Scour valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Power Capacitor
Repair and reconditioning of starter
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by the TWAD Board officers.
5 HP Starter
3 HP Starter
2 HP Starter
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
Cheranmahadevi (Headworks)3.00 LL
Kanganakulam 3.00 LL
Pulavankudiyiruppu3.00 LL
Mavadi 2.00 LL
Govindaperi1.65 LL
Padmaneri2.00 LL
SN Pallivasal 2.00LL
Kalakadu0.30LL
Rajapudur0.60LL
Madapppuram 1.00 LL
Kannanallur0.60LL
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work excavation deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete and as directed by TWAD Board officers.
TRANSFORMER
Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as rected by TWAD Board Officers
Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 433KV LV Bushing copper rod to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of paint to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for hot air chamber treatment for IR value Improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TwAD Board Officers
Charges for transformer tank cleaning and painting work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
Hire charges for Mobile crane used for unloading of Transformer from Bed to loading into Vehicle for moving to Work Shop & After Repair work, Placing back in Transformer Bed
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 9.16 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 3343.40 ML (9.16*365)
Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. Ist Depth of 2m
SS clampset Leak i) AC pipe with CID joint - 262.014 cum ii)PSC Pipe of various sizes - 301.743 cum
Collar Leak i) AC Pipe of various sizes - 712.505 cum ii)PSC Pipe of various sizes -2837.720 cum
Supply and delivery of CID joint inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
300 mm AC Class 15 Pipe
250 mm AC Class 15 Pipe
200 mm AC Class 15 Pipe
150 mm AC Class 15 Pipe
Supply and delivery of Leak arresting Flexible MS Clamps inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by the TWAD Board officers.
450 mm NB PSC
400 mm NB PSC
350 mm NB PSC
Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers for Collar Leak
i) AC Pipe of various sizes - 935 kg ii) PSC Pipe of various sizes - 2530 kg
Supply and delivery of Hardcrete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers for Collar Leak
i) AC Pipe of various sizes - 935 litre ii) PSC Pipe of various sizes -2440 litre
Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
i) AC Pipe of various sizes - 1060 kg ii) PSC Pipe of various sizes - 2810 kg
Dewatering using 5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
SS clampset Leak i) AC Pipe with CID joint- 590 hrs ii) PSC Pipe of various sizes -640 hrs
Collar Leak i) AC Pipe of various sizes - 935 hrs ii) PSC Pipe of various sizes -2250 hrs
Refilling the foundation with excavated Soil (other than sand)complying with standard specification in layers of not more than 15cm thick, watering, well ramming, consolidating after the pipes are laid Jointed and tested etc., and removing and depositing the surplus reath at the place shown etc., complete and as directed by TWAD Board Officers
SS clampset Leak i) AC pipe with CID Joint -262.014 cum ii) PSC Pipe of various sizes - 301.743 cum
Collar Leak i) AC Pipe of various sizes - 712.505 cum ii) PSC Pipe of various sizes - 2837.720 cum
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. Ist Depth of 2m
i) PVC Pipes of various sizes - 766.069 cum ii) AC Pipes of various sizes - 209.712 cum iii) PSC Pipes of various sizes - 189.693 cum
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
PVC Coupler Fabricated
50 mm PVC Coupler Fabricated 6 KSC
63 mm PVC Coupler Fabricated 4 KSC
75 mm PVC Coupler Fabricated 4 KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
300 mm DI K7 Class
250 mm DI K7 Class
200 mm DI K7 Class
Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
355.6 mm x 4 mm thick MS Pipe
406.4 mm x 4 mm thick MS Pipe
457 mm x 4 mm thick MS Pipe
Supply and Delivery of MJ Collars inclusive of transportation charges anywhere in Tamilnadu etc complete and as directed by TWAD Board officers
200mm MJ Collars
250mm MJ Collars
300mm MJ Collars
350mm MJ Collars
400mm MJ Collars
450mm MJ Collars
Removing the burst PSC /PVC/A.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
50mm PVC 6KSC
63mm PVC 4KSC
75mm PVC 4KSC
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
300 mm dia AC Class 15 Pipe
250 mm dia AC Class 15 Pipe
200 mm dia AC Class 15 Pipe
350 mm PSC Pipes of various classes
400 mm PSC Pipes of various classes
450 mm PSC Pipes of various classes
REPAIR AND RENEWAL OF PUMPSETS
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Submersible /Monoblock Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
Submersible Pump Set
HSC Pump set
Centrifugal Pump set
Repair and Reconditonig works in various capacity HSC Pumpset including cost of all material excluding bronze impeller conveyance ,labour charges for removing and re-erection of etc as directed by TWAD Board officers
Supply and delivery of 440V Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc. complete and as directed by TWAD Board officers.
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc. complete and as directed by TWAD Board officers.
Upto 5A-10A
Upto 10A-20A
Upto 20A-30A
Attending cable fault by replacing the cable
Supply, delivery of 1.1 KV Grade Armoured aluminium Conductor cross Linked Poly ethylene insulated PVC sheathed cables confirmaing to IS etc., complete and as directed by TWAD board Officers. for following Wells submersible motor to main panel board.
3 core 50 Sq. mm aluminium cable
Laying of 1.1 KV Grade PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 50 Sq. mm aluminium cable
Jonting the 1.1KV grade PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials, Labour etc complete directed by the TWAD Board officers
3 core 50 Sq. mm aluminium cable
Supply and delivery of following Range AMPS 3 Pole ACB & MCCB Switch (Air circuit breakers & Moulted case circuit breakers) inclusive of handling charges, F.O.R destination etc. complete and as directed by TWAD Board officers. to control EB supply from E.B Pole to Main Panel Board
4 Pole MCCB
Attending repair ,rectification and reconditioning CI Sluice/scour / CI NRV/ Double Air valve including cost of all material ,conveyance ,labour charges for removing and re-erection of valve etc., complete and as directed by TWAD Board officers
CI Sluice valve
CI NRV valve
Double air valve
CI Scour valve
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
125 mm Gate valve
100 mm Gate valve
80 mm Gate valve
65 mm Gate valve
50 mm Gate valve
40 mm Gate valve
Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board officers
Power Capacitor
Repair and reconditioning of starter
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc., complete and as directed by the TWAD Board officers.
5 HP Starter
3 HP Starter
2 HP Starter
CLEANING OF SUMPS
Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
Cheranmahadevi (Headworks)3.00 LL
Kanganakulam 3.00 LL
Pulavankudiyiruppu3.00 LL
Mavadi 2.00 LL
Govindaperi1.65 LL
Padmaneri2.00 LL
SN Pallivasal 2.00LL
Kalakadu0.30LL
Rajapudur0.60LL
Madapppuram 1.00 LL
Kannanallur0.60LL
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Earth work excavation deploying earth moving machinery for desilting channel and forming bund on either side and depositing the earth on banks including jungle clearance etc complete and as directed by TWAD Board officers.
TRANSFORMER
Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as rected by TWAD Board Officers
Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of 433KV LV Bushing copper rod to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Supply and delivery of paint to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for hot air chamber treatment for IR value Improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TwAD Board Officers
Charges for transformer tank cleaning and painting work to 200 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour Charges for new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
Hire charges for Mobile crane used for unloading of Transformer from Bed to loading into Vehicle for moving to Work Shop & After Repair work, Placing back in Transformer Bed
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A24 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.48 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 176.66 ML (0.484*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
PVC COUPLER FABRICATED
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Sub Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
10HP (505lpm x 58M head)
5HP (505 LPM x 59M head)
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Power capacitor
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Officers
Supply and delivery of 9 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay Upto 5A which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc complete directed by the TWAD Board officers
For 5 HP DOL Starter - 1 Nos
For10 HP DOL Starter - 1 Nos
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm Gate valve
100 mm Gate valve
SUMP CLEANING
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
3.00 LL Sump at Ponnagar
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027 - 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.48 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 177.14 ML (0.484*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
PVC COUPLER FABRICATED
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Sub Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
10HP (505lpm x 58M head)
5HP (505 LPM x 59M head)
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Power capacitor
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Officers
Supply and delivery of 9 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay Upto 5A which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc complete directed by the TWAD Board officers
For 5 HP DOL Starter - 1 Nos
For10 HP DOL Starter - 1 Nos
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm Gate valve
100 mm Gate valve
SUMP CLEANING
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
3.00 LL Sump at Ponnagar
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028 - 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.48 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 176.66 ML (0.484*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. For PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
PVC COUPLER FABRICATED
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Sub Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
10HP (505lpm x 58M head)
5HP (505 LPM x 59M head)
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Power capacitor
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Officers
Supply and delivery of 9 Amps\440V Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay Upto 5A which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc complete directed by the TWAD Board officers
For 5 HP DOL Starter - 1 Nos
For10 HP DOL Starter - 1 Nos
Supply, delivery and fixing of 50 mm G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
80 mm Gate valve
100 mm Gate valve
SUMP CLEANING
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
3.00 LL Sump at Ponnagar
Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers.
Cost of Chemicals
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE- A25 (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
For the Year 2026-27 (From 01.04.2026 - 31.03.2027)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.50 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 182.500 ML (0.50*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Sub Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
7.5 HP ( 429 lpm X 40m head) Headworks
10HP (415 lpm X 42m head) Mannarkovil, Ayanthiruvaleeswaram)
7.5 HP ( 289 lpm X 40m head) Brammadesam
3 HP ( 154 lpm X 36m head) Vagaikulam
5 HP ( 505 lpm X 29m head ) Mannarkovil
1 HP ( 119 lpm X 15m head ) Ayanthiruvaleeswaram)
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Power capacitor
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI markingetc as directed by TWAD Board officers
Supply and delivery of Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
9 Amps\440V
12 Amps\440V
18 Amps\440V
25 Amps\440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay Upto 5A to 20A which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
upto 5A
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
125 mm Gate valve
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc complete directed by the TWAD Board officers
For 10 HP DOL Starter - 4 Nos
For 7.5 HP DOL Starter - 2 Nos
For 5 HP DOL Starter - 2 Nos
For 3 HP DOL Starter - 2 Nos
For 1 HP DOL Starter - 2 Nos
SUMP CLEANING
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
3.00 LL capacity of sump @ Brammadesam
0.60 LL capacity of sump @ Mannarkoil
0.30 LL capacity of sump @ Ayanthiruvaleeswaram
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board officers - IF well No.1
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2027-28 (From 01.04.2027- 31.03.2028)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.50 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 183.00 ML (0.50*366)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Sub Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
7.5 HP ( 429 lpm X 40m head) Headworks
10HP (415 lpm X 42m head) Mannarkovil, Ayanthiruvaleeswaram)
7.5 HP ( 289 lpm X 40m head) Brammadesam
3 HP ( 154 lpm X 36m head) Vagaikulam
5 HP ( 505 lpm X 29m head ) Mannarkovil
1 HP ( 119 lpm X 15m head ) Ayanthiruvaleeswaram)
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Power capacitor
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI markingetc as directed by TWAD Board officers
Supply and delivery of Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
9 Amps\440V
12 Amps\440V
18 Amps\440V
25 Amps\440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay Upto 5A to 20A which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
upto 5A
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
125 mm Gate valve
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc complete directed by the TWAD Board officers
For 10 HP DOL Starter - 4 Nos
For 7.5 HP DOL Starter - 2 Nos
For 5 HP DOL Starter - 2 Nos
For 3 HP DOL Starter - 2 Nos
For 1 HP DOL Starter - 2 Nos
SUMP CLEANING
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
3.00 LL capacity of sump @ Brammadesam
0.60 LL capacity of sump @ Mannarkoil
0.30 LL capacity of sump @ Ayanthiruvaleeswaram
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board officers - IF well No.1
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
For the Year 2028-29 (From 01.04.2028- 31.03.2029)
Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.50 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 182.50 ML (0.50*365)
Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of Pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
PVC Pipes of various Sizes
Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers
90mm PVC 4KSC
110mm PVC 4KSC
140mm PVC 4KSC
Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, inclusive of transportation charges to anywhere in Tamilnadu., etc., complete and as directed by TWAD Board officers.
90mm PVC 4 KSC
110mm PVC 4KSC
140mm PVC 4KSC
90 mm PVC Coupler Fabricated 4 KSC
110 mm PVC Coupler Fabricated 4 KSC
140 mm PVC Coupler Fabricated 4 KSC
Supply and delivery of the following sizes of GI pipes ( Medium class) confirming to the IS and other specifications including transportation charges to stock yard any where in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
50 mm GI pipe
65 mm GI pipe
80 mm GI pipe
100 mm GI pipe
125 mm GI pipe
Rewinding of Motors/ Coil in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6. of General conditions of Contract Part II. complete and as directed by the TWAD Board officers.
Rewinding of motor and reconditioning pump and repair works to Sub Motor including cost of all material ,conveyance ,labour charges for removing and re-erection etc as directed by TWAD Board officers
7.5 HP ( 429 lpm X 40m head) Headworks
10HP (415 lpm X 42m head) Mannarkovil, Ayanthiruvaleeswaram)
7.5 HP ( 289 lpm X 40m head) Brammadesam
3 HP ( 154 lpm X 36m head) Vagaikulam
5 HP ( 505 lpm X 29m head ) Mannarkovil
1 HP ( 119 lpm X 15m head ) Ayanthiruvaleeswaram)
Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II.B74 complete and as directed by the TWAD Board officers.
Power capacitor
Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI markingetc as directed by TWAD Board officers
Supply and delivery of Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers
9 Amps\440V
12 Amps\440V
18 Amps\440V
25 Amps\440V
Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay Upto 5A to 20A which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
upto 5A
Supply, delivery of following size of PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 and as Amended there after well submersible motor to main panel board.
3 core 10 Sq. mm copper cable
Laying of PVC insulated and sheathed 3 core flat type Copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
3 core 10 Sq. mm copper cable
Jonting the PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 as per IE Rules including Jointing materials etc complete directed by the TWAD Board officers
3 core 10 Sq. mm copper cable
Supply, delivery and fixing of G.M GATE VALVES AS PER IS BS 5154 and related IS Specifications inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers
50 mm Gate valve
65 mm Gate valve
80 mm Gate valve
100 mm Gate valve
125 mm Gate valve
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) inclusive of two level guard worth and auto start facility worth etc complete directed by the TWAD Board officers
For 10 HP DOL Starter - 4 Nos
For 7.5 HP DOL Starter - 2 Nos
For 5 HP DOL Starter - 2 Nos
For 3 HP DOL Starter - 2 Nos
For 1 HP DOL Starter - 2 Nos
SUMP CLEANING
Removal of sediments and depositions of sludge, silt particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the sidewall and bottom of sump using wirebrushes, brooms, collecting, lifting of the deposited silt particles outside the sump, washing side wall and floor slab using bleaching powdre etc complete and as directed by TWAD Board officers
3.00 LL capacity of sump @ Brammadesam
0.60 LL capacity of sump @ Mannarkoil
0.30 LL capacity of sump @ Ayanthiruvaleeswaram
Desilting light or sandy soil or silt from infiltration wells below water level including the charges for special tools and plants and air compressor etc.complete and as directed by TWAD Board officers - IF well No.1
Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
Supply , Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurance, all other incidental charges at site of work etc. complete. and as directed by TWAD Board officers.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BIDTirunelveli.pdf
Tender Documents • 1.40 MB
BOQ_763862.xls
BOQ • 6.55 MB
Download all tender documents and submit your bid