Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹42.4 L+₹3.7 L (9.55%)Rejected-Finance SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹42.6 L+₹4.0 L (10.3%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹42.7 L+₹4.1 L (10.5%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹42.8 L+₹4.1 L (10.7%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
3 Aug 2023, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2023_MES_608742_1
8483/E8 GE (P) NAVY MANDOVI
Open Tender
Construction Works
Item Rate
270 days
Mandovi
As per tender documents
8 documents required · 8 mandatory
₹500
GE (P) Navy Mandovi
₹77,600
Yes
14 Nov 2023
12 Jul 2023
7 Aug 2023
12 Jul 2023
3 Aug 2023
27 Jul 2023
13 Jul 2023 - 26 Jul 2023
Amount
BUILDING PORTION
Taking down cement or cement lime plaster, any description on stone/ PCC block/ brick wall or top of chajja including raking out joints, hacking for key, scrubbing down with water etc and removal of debris including filling of open joints in cement mortar 1:6 complete all as specified and directed.
M & L for dubbing out average 15 mm thick on irregular face of external and internal wall surfaces (when specifically ordered in writing) in CM 1:6 complete all as specified and as directed.
M & L for rendering 15 mm thick in two layers in cement mortar 1:3, 10 mm thick first layer and 5 mm thick outer layer mixed with WPC as per manufacturer's instructions on fair faces of brickwork or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
Supply only integral waterproofing compound complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortar 1:3 on ceiling surfaces finished even & smooth, without using extra cement complete all as specified and directed.
M & L for preperation of newly plastered wall surfaces, ceiling cornices etc, making surface smooth by applying 1 mm thick ready mix putty where ever required and applying two coats of acrylic emulsion exterior paint of approved shade, over a coat of primer, including necessary scaffolding complete all as specified and directed.
M & L for preparation of newly plastered wall surfaces, priming with alkali resistant priming paint, applying 1 mm thick wall care putty wherever required and distempering with two coats of distemper oil emulsion, white or tinted, complete all as specified and directed.
M & L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M & L for complete removal of existing treatment including preperation of old plastered wall surfaces preparatory to distempering, applying 1 mm thick acrylic wall care putty, priming the surface with alkali resistant priming paint and distempering with two coats of distemper oil emulsion, white or tinted complete all as specified and directed.
M & L for preparation of old plastered ceiling surfaces and applying two coats of white wash complete all as specified and directed.
M & L for preparation of old decorative wall surfaces, ceiling cornices etc by brooming, scrapping down dust particle, smoke soot, moulds, moss and efforescent salts etc, making surface smooth by applying ready mix putty where ever required and applying two coats of acrylic emulsion exterior paint complete all as specified and directed.
M & L for chipping, removing carefully concrete work using low impact hammer, breaking without damaging the structure & cleaning and disposing off debris outside the premises complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M & L for cleaning existing reinforcement with wire/ rotary wire brush, making the surfaces free of loose material, rust spalls, dirt etc, applying two coats of alkaline rust converting primer FEOVERT, confirming to ASTM-B-117, on rebars, with time interval of 6 hour between each coat) and applying protective coating of IPNET-RB complete all as specified and directed.
S & F stainless steel wire netting, 1.40 mm nominal dia of wire and average size of mesh 25 mm and fixed with tinned tacks of wire staples, including necessary steel frame complete all as specified and directed.
M & L for rendering 5 mm thick over gunniting / concrete surface in cement mortar 1:4 and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for injecting of cement slurry grout in 1:2 ratio (1 part cement, 2 parts water) including super plsticizer (Supercom-100) 250 ml/50 kg into prefixed nozzles in the walls and slabs by means of pump at a pressure of 0.5 Kg/sq.cm till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled, for rehabilitation of walls and slabs complete all as specified and directed. Note: Mixing shall be done using mechanical mixer continuously stirring mechanically to keep cement particles in suspension.
M & L for injecting low viscosity MONOPOL (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories, till nozzles refuse to accept the grout, including mixing of material components (Part a & b) in quantities as per manufacturer's instruction by weigh batching, grouting by maintaining the pressure at exit (0.5 to 1.0 kg/sq.cm) by monitoring pressure guage at exit, grouting the material through prefixed nozzles in the structural elements @ 100ml per nozzle and repeating the process for all the nozzles, for rehabilitation of beam and columns, complete all as specified and directed.
M & L for drilling and fixing Rohibb Teflon nozzles in RCC structural members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at intervals of 500 center to center in staggered manner and carrying out the work as under complete all as specified and directed. (i) Cleaning of holes : Holes shall be cleaned by air blower prior to fixing nozzles. (ii) Fixing of nozzles : 12mm dia Rohibb Teflon nozzles shall be inserted in cleaned holes. External end of nozzles to be machine cut to receive outlet of grouting gun. Nozzles shall be fixed inside the holes by applying thixotropic epoxy putty to ensure complete sealing. The system shall be cured for min 12 hrs. (iii) Cutting of nozzles : Nozzles shall be cut by chisel after completion of grouting without damaging structural elements.
M & L for providing and applying jacketing around columns with micro concrete (Molith-MC) M40 including lifts, shuttering, drilling holes and fixing shear anchor complete all as specified and directed. Note: Reinforcement shall be measured and paid separately. (Quoted rates shall be deemed to be inclusive of jacketing, formwork and micro concrete)
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises to a distance exc 250 m and not exc 1000 m, spread and levelled, complete all as specified and directed.
M & L for 15mm thick screed bed or bedding layer of cement mortar 1:3 for laying floor finishes for kota stone complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete vertical surfaces in cement mortar 1:4 complete all as specified and directed.
M & L for providing for non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for providing for non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for providing machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
M & L for providing glazed ceramic coloured tiles in vertical surface, 350 x 250 x 7 mm/ 450 x 350 x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for providing 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub-floors, sub-bases, floors etc and surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for cleaning the surfaces thoroughly and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m complete all as specified and directed.
M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in sub-floors, sub-bases, floors etc complete all as specified and directed.
Taking down steel tubing and connections of 15 mm dia bore complete all as specified and directed.
Taking down steel tubing and connections of 20 mm dia bore complete all as specified and directed.
Supplying and laying of CPVC pipes of 20 mm outer dia, SDR 11 & plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed.
Supplying and laying of CPVC pipes of 25 mm outer dia, SDR 11 & plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed.
S & F in repairs stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm dia bore complete all as specified and directed.
S & F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe of 15 mm dia bore complete all as specified and directed.
S & F in repairs bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm dia bore complete all as specified and directed.
S & F PVC connections of size 15 mm, 450 mm long with PTMT nuts complete all as specified and directed.
S & F in repairs PTMT bathroom mirror cabinet of size 600mm x 450mm x 200mm including all necessary arrangements for fixing to wallcomplete all as specifeid and directed. Make: Shakthi Cat Pt No SB -155 or Water Tec or equivalent make
S & F in repairs PTMT soap dish of approximate size 160 x 160 x 90 mm embedded in wall complete all as specified and directed.
S & F in repairs brass, tubular towel rail, chromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S & F in repiairs wash basins, Vitreous China, flat back type, 550mm x 400mm size, including brackets and cutting for and pinning in ends of brackets or erecting stand and fixing of polyethylene of low or high density or PVC 32 mm dia waste pipe complete all as specified and directed.
S & F in repairs vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including seat cover complete all as specified and directed.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets and 32 mm dia flush pipe of polyethylene of low or high density or PVC and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
S & F 2 in 1 health faucet with hook, chromium plated, with 1.5 m tube complete all as specified and directed.
S & F in repairs brass chromium plated shower rose, 125 mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S & F in repairs ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 25 mm dia bore complete all as specified and directed. (minimum weight 25 mm - 455 gm)
S & F ball valves to CPVC pipe of 25 mm dia bore complete all as specified and directed.
S & F in repairs tank adaptor to CPVC pipe of 25 mm dia bore complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S & F 75 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 50 mm dia high density polyethylene (HDPE) pipes of pressure rating 6kgf/cm2 fixed complete to walls, ceilings or in floors including necessary fittings complete all as specified and directed.
M & L for PVC (SWR) multi floor trap of 75 mm dia outlet, with grating including jointing with solvent cement, fixed in repairs, complete all as specified and directed.
S & F PVC (SWR) bends of 110 mm dia bore, any radius, with acess door complete all as specified and directed.
S & F PVC (SWR) bends of 75 mm dia bore, any radius, with acess door complete all as specified and directed.
S & F PVC (SWR) junction single (single T) of 110 mm dia bore, equal or unequal, with acess door complete all as specified and directed.
S & F PVC (SWR) junction single (single T) of 75 mm dia bore, equal or unequal, with acess door complete all as specified and directed.
M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for providing 18 mm thick marine waterproof plywood, grade BWR, type BB, grade 2 quality, interior grade, commercial type, fixed with screws to timber framed work complete all as specified and directed.
S & F in repairs aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
S & F in repairs sinks made of stainless steel 1 mm thick, kitchen or laboratory with plugs, washers and wastes; includding bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, of overall size 495mm x 420mm and of bowl size 410mm x 330mm x 160mm complete all as specified and directed.
INTERNAL ELECTRIFICATION
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
Taking down DB complete all as specified and directed.
Taking down submain wiring complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, pressed steel terminal boxes firmly fixed with pipe /wall including concealed modular frame and cover, 3mm thick laminated hylem sheet or plastic masonite laminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for the following complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
One light point controlled by one switch
One light point controlled by one two way switch
One ceiling/ exhaust fan point controlled by one switch
One 3 pin socket outlet 5 Amp on same board with other switches
One 3 pin socket outlet 5 Amp on independent board
One bell point
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, pressed steel terminal boxes firmly fixed with pipe /wall including concealed modular frame and cover, 3mm thick laminated hylem sheet or plastic masonite laqminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 3 pin 15 Amps switch socket combination on independent board complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
S & F in repairs switch piano, 5 amp, single pole, one way, flush type, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs switch piano, 5 amp, single pole, two way, flush type, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs switch socket combination 2/3 pin and 5 Amps, flush type, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs switch socket combination 2/3 pin and 15 Amps, flush type, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs bell push, flush type 5 Amps, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs bell buzzer/ Ding dong, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs fan regulator, electronic step type, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs ceiling rose, 3 terminal, PVC poly carbonated, isolating body, complete all as specified and directed.
M & L for taking down celing fan/ exhaust fan of any make and capcity from working site, removing blades, cleaning and painting with matching synthetic enamel paint on complete body and blades, keeping in safe custody of contractor till refixing and refixing in the same location complete all as specified and directed.
S & F in repairs LED tube light fitting 1 X 20 watt, 220V AC decorative box type with driver and holder, including LED tube light, connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw complete all as specified and directed.
S & F exhaust fan, 250 mm sweep single phase 230/240 volt AC supply 50 HZ, made of sturdy engineered plastic complete with louvers and shutters, fixed with suitable MS Bracket, nuts, bolts and fixing arrangement, including making/ resizing holes and PCC work as per site requirement complete all as specified and directed.
S & F in repairs LED tube light fitting 1 X 10 watt, 220V AC decorative box type with driver and holder, including LED tube light, connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw complete all as specified and directed.
S & F sheet metal enclosure for MCB's (D.B), double door, IP-42 protection, SPN 8 way, 230 Volts, with suitable rated bus bar, complete all as specified and directed.
S & F MCCB distribution board (DB), TPN 6 way, with 125 Amps 18 KA MCCB and rated bus bar including connected accessories complete all as specified and directed.
S & F MCB SPN 32 Amps, 230 Volts, 'C' series complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 230 Volts, 'C' series complete all as specified and directed.
S & F sheet metal enclosure earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed.
M & L for submain wiring with two runs of 6 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 6 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of suitable dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
M & L for submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of suitable dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
M & L for taking down geyser of any size & make by disconnecting water connection pipes, fixing clamps and electrical connection, keeping safe in contractor's custody till completion of all electrical works and refixing in the same location with all connected connections & accessories complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC earth chamber in PCC 1:3:6 type C1, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, 15 mm dia light grade GI pipe with funnel for watering, RCC chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing point complete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost.
Tara Construction
M/S NAGINENI RANGA RAO
SANTOSH CONSTRUCTION
Super Construction
N VENKATESWARLU
Shree Ram Enterprises
AATREYA CONSTRUCTION
SACHIN CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .