| 1 | L1₹26.2 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | ₹26.2 L Quoted ₹27.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹29.9 L+₹2.9 L (10.9%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹29.9 L+₹2.9 L (10.9%) | L2 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | P S TRADERS L2 | SNOWY ENGINEERING INC L1 |
|---|---|---|---|---|---|
| 1.00 | Material and labour for de-scaling condensers of central AC plant 3X115 TR capacity of condenser by opening side plate, flushing the condenser tubes using de-scaling solution, Roding the condenser tubes carefully removing all the deposited materials completely and raising the solution through condenser tubes till clear water starts to come out from the condensers as complete including re-fixing the side plates by replacing gaskets & testing complete for satisfactory working at HQ CAMS complete all as specified and as directed. | 3 | Each Job | 10,000 ₹30,000 Lowest | 15,000 ₹45,000 |
| 2.00 | ditto all as per item No. 1 above but Capacity of 2 X 220 TR at DGIS. | 3 | Each Job | 10,000 ₹30,000 Lowest | 17,500 ₹52,500 |
| 3.00 | Material and labour for leakage detection of chiller and condensor pipe lines by charging dry Nitrogen Gas and with standing pressure for 24 hours, rectification of leakages, evacuation of the system as per manufacturer’s instruction for capacity of 3x115 TR AC plant at HQ CAMS complete all as specified and as directed.
Note :- The rates quoted by the contractor shall deemed to include the cost of Nitrogen gas, charges for T&P and empty cylinders. | 3 | Each Job | 1,000 ₹3,000 Lowest | 6,200 ₹18,600 |
| 4.00 | ditto all as per item No. 3 above but Capacity of 2 X 220 TR at DGIS. | 3 | Each Job | 3,000 ₹9,000 Lowest | 6,840 ₹20,520 |
| 5.00 | Supply and fixing Acoustic treatment/ lining of area of AHU room with 22G, GI channels of 50x50 mm size fitted at 600x600mm Grids. These girids will be fitted with 50mm thick 32 kg/cum fiber glass insulation covered be fiber glas tissue and 24 G Al perforated sheet and as required . The joint shall be minimium overlapping of 75mm with 30mmx 3mm aluminium strip covering. All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and directed. | 46 | Sqm | 1,100 ₹50,600 | 1,045 ₹48,070 Lowest |
| 6.00 | M&L in replacement of providing and filling post/frame work of stainless steel, grade 304 pipes including braces of stainless steel, plates , angle flats , tubular sections etc including cutting, hoisting fixing with argon welding , bright finish , buffing polishing, grouting with PCC 1:2:4 type B1(using 20mm graded stone aggregates) in the existing foundations complete with necessary holes, nuts , bolts, caps and anchor plates for stainless steel, as specified and directred | 20 | KG | 130 ₹2,600 Lowest | 148 ₹2,960 |
| 7.00 | M&L for installation of poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminium composite panel having 0.50mm thick skin of aluminium both side. The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter , message (bi-lingual), symbol and borders etc as per IRC 67-2001. The aluminium composite panel shall be suitably fixed inside stainless steel frame work with complete fixing angle support , nut bolt etc complete all as specified and directred | 3 | Sqm | 6,500 ₹19,500 | 5,433 ₹16,299 Lowest |
| 8.00 | Supply & Fixing HRC fuse link, type HN, Cap 250 Amps complete all as specified and as directed. | 4 | Each | 200 ₹800 | 125 ₹500 Lowest |
| 9.00 | Supply & Fixing HRC fuse link, type HN, Cap 200 Amps complete all as specified and as directed. | 4 | Each | 200 ₹800 | 110 ₹440 Lowest |
| 10.00 | Supply & Fixing contactor 110A current rating with add on auxilary contactor (2NO + 2NC) complete all as specified and as directed. | 4 | Each | 8,700 ₹34,800 | 3,890 ₹15,560 Lowest |
Tender Value
₹34.0 L
EMD Value
₹67,980
Closing Date
13 Aug 2026, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
CERTAIN ESSENTIAL REPAIR TO AIR CONDITIONING PLANTS OF CAPACITY 3X115 TR AT HQ CAMS AND 2 X 220 TR AT HQ DGIS UNDER GE (U) PM DELHI CANTT10
2026_MES_778993_1
GE(U)/PM/D-36/2026-27
Open Tender
Miscellaneous Works
Item Rate
240 days
Delhi Cantt
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹67,980
Yes
14 Sept 2026
16 Jul 2026
17 Aug 2026
16 Jul 2026
13 Aug 2026
30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for de-scaling condensers of central AC plant 3X115 TR capacity of condenser by opening side plate, flushing the condenser tubes using de-scaling solution, Roding the condenser tubes carefully removing all the deposited materials completely and raising the solution through condenser tubes till clear water starts to come out from the condensers as complete including re-fixing the side plates by replacing gaskets & testing complete for satisfactory working at HQ CAMS complete all as specified and as directed. | 3 | Each Job | - | - |
| 2 | ditto all as per item No. 1 above but Capacity of 2 X 220 TR at DGIS. | 3 | Each Job | - | - |
| 3 | Material and labour for leakage detection of chiller and condensor pipe lines by charging dry Nitrogen Gas and with standing pressure for 24 hours, rectification of leakages, evacuation of the system as per manufacturer’s instruction for capacity of 3x115 TR AC plant at HQ CAMS complete all as specified and as directed.
Note :- The rates quoted by the contractor shall deemed to include the cost of Nitrogen gas, charges for T&P and empty cylinders. | 3 | Each Job | - | - |
| 4 | ditto all as per item No. 3 above but Capacity of 2 X 220 TR at DGIS. | 3 | Each Job | - | - |
| 5 | Supply and fixing Acoustic treatment/ lining of area of AHU room with 22G, GI channels of 50x50 mm size fitted at 600x600mm Grids. These girids will be fitted with 50mm thick 32 kg/cum fiber glass insulation covered be fiber glas tissue and 24 G Al perforated sheet and as required . The joint shall be minimium overlapping of 75mm with 30mmx 3mm aluminium strip covering. All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and directed. | 46 | Sqm | - | - |
| 6 | M&L in replacement of providing and filling post/frame work of stainless steel, grade 304 pipes including braces of stainless steel, plates , angle flats , tubular sections etc including cutting, hoisting fixing with argon welding , bright finish , buffing polishing, grouting with PCC 1:2:4 type B1(using 20mm graded stone aggregates) in the existing foundations complete with necessary holes, nuts , bolts, caps and anchor plates for stainless steel, as specified and directred | 20 | KG | - | - |
| 7 | M&L for installation of poly carbonate micro prismatic type retro reflective boards conforming to XI of ASTM, made of 4mm thick substrate of aluminium composite panel having 0.50mm thick skin of aluminium both side. The front side is to covered with full cube poly carbonate prismatic reflecting sheeting conforming to proposed type XI of ASTM with coloured scheme, including subject matter , message (bi-lingual), symbol and borders etc as per IRC 67-2001. The aluminium composite panel shall be suitably fixed inside stainless steel frame work with complete fixing angle support , nut bolt etc complete all as specified and directred | 3 | Sqm | - | - |
| 8 | Supply & Fixing HRC fuse link, type HN, Cap 250 Amps complete all as specified and as directed. | 4 | Each | - | - |
| 9 | Supply & Fixing HRC fuse link, type HN, Cap 200 Amps complete all as specified and as directed. | 4 | Each | - | - |
| 10 | Supply & Fixing contactor 110A current rating with add on auxilary contactor (2NO + 2NC) complete all as specified and as directed. | 4 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Sch36.pdf
Additional Documents • 0.75 MB
BOQ_872518.xls
BOQ • 0.34 MB
Tender36.pdf
Tender Documents • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .