Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.1 L+₹2.8 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Rejected in AOC | |
| 3 | L3₹24.8 L+₹3.5 L (16.6%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L3 | Rejected-Finance Rejected in AOC | |
| 4 | L4₹28.0 L+₹6.7 L (31.7%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Rejected in AOC | |
| 5 | L5₹28.3 L+₹7.0 L (33.1%)Rejected-Finance | L5 | Rejected-Finance Rejected in AOC |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
5 Feb 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Outsourcing and Maintenance of sewage treatment plant under GE (Army) Suratgarh at Suratgarh Mil Stn
2020_MES_313381_1
GE (A) SOG - 67/19-20
Open Tender
Civil Works
Item Rate
330 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹61,000
Yes
3 Mar 2020
9 Jan 2020
7 Feb 2020
9 Jan 2020
5 Feb 2020
22 Jan 2020
Amount
Manning and operation including minor repair/maintenance of sewage treatment plant in MAP Phase-I in Two shifts (Each shift of 08 hours) daily including Sundays and holidays by employing FGM (Fitter General Mechanic) - 01 No. and Helper - 01 No in each shift comprising with the following equipments :- Note :- 1st Shift from 0600 hours to 1400 hours and 2nd Shift from 1400 hours to 2200 hours. (a) Non cloging submersible pumping set - 03 Nos (b) Electric LT Panel complete - 01 No. (c) DG Set 125 KVA - 01 No. (d) Change over switch 3 phase 200 Amps - 01 No (e) chlorine dosing plant - 01 No. (f) Air blower with electric motor - 02 Nos (g) Recycle pumping set 20 HP - 02 Nos
Manning and operation including minor repair/maintenance of Intermediate Sewage Pump House in One shift of 08 hours daily including Sundays and holidays by employing FGM (Fitter General Mechanic) - 01 No. in each shift comprising with the following equipments :- Note :- Shift from 0600 hours to 1400 hours (a) Submersible pumping set - 02 Sets (b) Electric LT Panel complete - 01 No
Manning and operation including minor repair/maintenance of Infantry Battalion Pump house installations in Two shifts (Each shift of 08 hours) daily including Sundays and holidays by employing FGM (Fitter General Mechanic) - 01 No. in each shift comprising with the following equipments :- Note :- 1st Shift from 0600 hours to 1400 hours and 2nd Shift from 1400 hours to 2200 hours. (a) Centrifugal pumping set 50HP - 02 Sets (b) Chloronomes Plant – 01 No. (c) Electric LT Panel complete - 01 No. (d) Change over switch 3 phase 200 Amps - 01 No. (e) DG Set 62.5 KVA - 01 No.
Outsourcing including minor repair/maintenance of JCO/ORs Pump House MAP Phase-I in Two shifts (Each shift of 08 hours) daily including Sundays and holidays by employing FGM (Fitter General Mechanic) - 01 No. in each shift comprising with the following equipments :- Note :- 1st Shift from 0600 hours to 1400 hours and 2nd Shift from 1400 hours to 2200 hours. (a) Centrifugal pumping set 20 HP - 02 Sets (b) Centrifugal pumping set 25 HP - 02 Sets (c) Electric LT Panel complete - 01 No. (d) Change over switch 3 phase 200 Amps - 01 No. (e) DG Set 125 KVA - 01 No.
Notes for Serial item No 1 to 4 :- (i) Minor repair includes all the periodical preventive maintenance such as greasing, oiling, tightening of nuts and bolts of DG sets / Incinerator and tightening of loose connections in starters and panels and replacing thimbles, rubber coupling etc. (ii) The contractor shall carryout the periodical maintenance every 30 days as per SOP and as directed by Engineer-in-charge and shall make a record of the same. The contractor shall prepare daily check sheet and log sheet and same shall be held at all the installations and. The log sheet shall be verified by the JE E/M and shall be produced to Engineer-in-charge. (iii) Contractor shall collect “DHPP(N) Fuel” from MES store yard or from collection point as decided by Engineer-in-charge. Vehicle for the transportation of “DHPP (N) Fuel” from MES store yard or from collection point up to installations shall be provided by the Department free of cost to the contractor. (iv) All installations shall be kept neat and clean all the time. (v) First Aid Box with basic medicines to be kept in main installation by the contractor. (vi) All the employees should have passed the ITI / NCT / VTcertificate / two years experience in requisite trade.The contractor is required to submit the ITI Pass certificate / experience certificate of all the employees to the Engineer-in-charge as desired to deploy on the installations. (vii) All types of T&P including digging tools required for day to day requirement shall be provided by contractor and all workers shall report to AGE E/M office daily with tools etc provided by the contractor. (viii) Bidders may please note that the rate quoted for outsourcing work shall not less than the minimum wages circulated by Chief Labour Commissioner, GOI, Min of Labour, New Delhi for Suratgarh (Class 'C' City) Plus ESI (EPF) & GST applicable to the bidder. Copy of applicable rate for ESI / EPF & GST shall be forwarded by the bidder alongwith bid documets cover 1. If the rate quoted by the bidder is lower than the applicable minimum wages + ESI / EPF + GST the same will be treated as 'Non-Bonafide' & the offer will not be considered for acceptance.
Taking out electric motor ,3 phase, 415 volts, AC, any capacity from foundation, all electric connection etc and servicing of motor including oiling greasing and replacement of the unserviceable parts like bearing, brunt copper winding, terminal plate etc and reassembling after repair the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge. Note: - (i) Major parts like bearing terminal cover plate, rewinding if required shall be measured and paid for separately as “Supply only” under respective items of BOQ. (ii) The unit rate includes the replacement of minor parts like copper lugs / thimble, Nuts, bolts, washers terminal connection plate and transportation cost if required for refixing the motor shall be provided by the contractor, nothing extra shall be paid on this account.
Supply only Ball Bearing of suitable size for 30/40/50 HP motor complete all as specified and directed by Engineer-in-charge. Make:-NBC / SKF / Tata.
Supply only Ball Bearing of suitable size for 15/20/25 HP motor complete all as specified and directed by Engineer-in-charge. Make:-NBC / SKF / Tata.
Supply only Ball Bearing of suitable size for 5/7.5/10 HP motor complete all as specified and directed by Engineer-in-charge. Make:-NBC / SKF / Tata.
Supply only cover plate of termila box of suitable size for 5-25 HP motor complete all as specified and directed by Engineer-in-charge.
Supply only cover plate of termila box of suitable size for 30-50 HP motor complete all as specified and directed by Engineer-in-charge.
Supply only terminal box with junction plate complete for any capacity motor complete all as specified and directed by Engineer-in-charge.
M&L for rewinding of electric motor 40 HP with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, upto terminal box complete all as specified and directed by Engineer-in-charge.
All as per serial item No. 12 here-in-above but motor of capacity 30 HP
All as per serial item No. 12 here-in-above but motor of capacity 25 HP
All as per serial item No. 12 here-in-above but motor of capacity 20 HP
M&L for taking out defictive non-clog submersible pump set of capacity 7.5 HP Capacity after disconnecting electrical connections, transportation to workshop for repair, dismantling the pump set for detection of repair and rewinding the same with supper enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, replacement of iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key, thrust bearing, replacement of unserviceable nut-bolts, washer, lugs, terminal plate, reassembling, refixing in its original position, making proper electrical connections, commissioning & testing complete all as specified and directed by Engineer-in-charge. Note : - (i) Cost for transportaion to workshop and carry back to site after repair is inlcuded in the unit rate of item nothing extra shall be paid on this acount. (ii) Iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key and thrust bearing if required for replacement shall be paid separetly against respective items of BOQ as "Supply only". (iii) Lathe work and grinding of shaft if required shall be paid separately against respective items of BOQ. (iv) Cost of new nuts, bolts, washers, lugs and terminal plate required to be replaced is included in the unit rate of this item nothing extra shall be paid on this account.
All as per serial item No. 16 here-in-above but motor of capacity 10 HP
Supply only Iron stainer suitable for non clog type submersible pump of capacity 7.5 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Iron stainer suitable for non clog type submersible pump of capacity 10 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Bronze impeller suitable for non clog type submersible pump of capacity 7.5 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Bronze impeller suitable for non clog type submersible pump of capacity 10 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for non clog type submersible pump of capacity 7.5 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for non clog type submersible pump of capacity 10 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Stainless steel sleeves suitable for non clog type submersible pump of capacity 7.5 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Stainless steel sleeves suitable for non clog type submersible pump of capacity 10 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Thrust bearing (Gun metal) suitable for non clog type submersible pump of capacity 7.5 HP complete all as specified and as directed by Engineer –in-charge.
Supply only Thrust bearing (Gun metal) suitable for non clog type submersible pump of capacity 10 HP complete all as specified and as directed by Engineer –in-charge.
Grinding shaft of non clog type submersible pump of capacity 7.5 / 10 HP with gridnding machine and including necessary welding & finishing work of shaft complete all as specified and as directed by Engineer –in-charge.
Taking out centrifugal motor of any capacity from foundation, dismantling the motor, taking out rotor and filling the material by welding work, finishing by lathe machine, replacement of unserviceable bearing, reassembling the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge. Note: - (i) Bearing shall be measured and paid for separately as “Supply only” under respective items of BOQ. (ii) New Nuts, bolts and washers if required for refixing the motor shall be provided by the contractor & nothing extra shall be paid on this account.
Supply and filling compressor oil CG 100 complete all as specified and directed by Engineer-in-charge.
Supply only ball bearing suitable for centrifugal Pump set assembled with 40 HP motor complete all as specified and directed by Engineer-in-charge. Make : NBC / SKF / TATA
All as per serial item No 31 here-in-above but assembled with 20/25 HP Motor
Supply only CI impeller suitable for centrifugal pump set assembled with 40 HP motor complete all as specified and directed by Engineer-in-charge. Make : Kirloskar
All as per serial item No 33 here-in-above but assembled with 25 HP Motor
All as per serial item No 33 here-in-above but assembled with 20 HP Motor
Supply only stainless steel Bush suitable for centrifugal pump set assembled with 40 HP motor complete all as specified and directed by Engineer-in-charge.
All as per serial item No 36 here-in-above but assembled with 20/25 HP Motor
Supply only shaft suitable for centrifugal pump set assembled with 20/25 HP motor complete all as specified and directed by Engineer-in-charge.
S&F in replacement gland plate assembly as per existing model & make suitable for centrifugal pump set assembled with 5/10/20/25 HP pump set complete all as specified & as directed by Engineer –in-charge.
S&F in replacement gland plate assembly as per existing model & make suitable for centrifugal pump set assembled with 30/40 HP pump set complete all as specified & as directed by Engineer –in-charge.
S&F in replacement rubber coupling as per existing model & make suitable for centrifugal pump set assembled with 30/40 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 41 here-in-above but assembled with 15 / 25 / 20 HP motor
S&F in replacement coupling assembly including rubber tyre as per existing model & make suitable for centrifugal pump set assembled with 10/15 HP motor complete all as specified & as directed by Engineer –in-charge.
S&F in replacement coupling assembly including rubber tyre as per existing model & make suitable for centrifugal pump set assembled with 20/25 HP motor complete all as specified & as directed by Engineer –in-charge.
S&F in replacement coupling assembly including rubber tyre as per existing model & make suitable for centrifugal pump set assembled with 30/40 HP motor complete all as specified & as directed by Engineer –in-charge.
Supply and fixing cast iron body (IS:210 FG 200) butterfly valves of size 50 mm stem stainless steel (IS 6603 12 Cr. 13) Bush-PTFE / Gun Metal SEAT-EPDM / Nitrile / NBR (Integrally Moulded) Powder Coated Carbon steel handle and Notch Plate. Standards - IS : 13095 complete all as specified and directed by Engineer-in-Charge. Make : BIR, Kirloskar, L&T
All as per serial item No 46 here-in-above but 80mm bore
All as per serial item No 46 here-in-above but 100mm bore
All as per serial item No 46 here-in-above but 150mm bore
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase,as suitable range, class -1, incl internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement single phase preventer type SDz5, SPPR + Timer, 415 V including necessary copper connection, lugs etc complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No XM818090000 or equivalent in ABB
S&F gland rope of size 8 / 10 / 12 sqmm or as required complete all as specified & as directed by Engineer –in-charge
S&F in replacement contactor 3 phase 415 volts having auxillary contracts, 50 Hz of AC3 Rating 38 Amps and AC1 Rating 56 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type MDX) Cat Part No CS96553 or equivalent of Siemens / ABB / C & S / Crompton Greaves
S&F in replacement contactor 3 phase 415 volts having auxillary contracts, 50 Hz of AC3 Rating 32 Amps and AC1 Rating 56 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type MDX) Cat Part No CS96552 or equivalent of Siemens / ABB / C & S / Crompton Greaves
S&F in replacement contactor 3 phase 415 volts having auxillary contracts, 50 Hz of AC3 Rating 18 Amps and AC1 Rating 32 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type MDX) Cat Part No CS96566 or equivalent of Siemens / ABB / C & S / Crompton Greaves
S&F in replacement contactor 3 phase 415 volts having auxillary contracts, 50 Hz of AC3 Rating 12 Amps and AC1 Rating 28 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type MDX) Cat Part No CS96565 or equivalent of Siemens / ABB / C & S / Crompton Greaves
S&F in replacement contactor ML-4, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 100 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type ML 4) Cat Part No SS90910 or equivalent of Siemens / Schneider / ABB / GE
S&F in replacement contactor ML-6, 3 phase 415 volts having auxillary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 110 Amps and AC1 Rating 125 Amps complete all as specified and as directed by Engineer –in-charge. Make : L&T (type ML 6) Cat Part No SS90921 or equivalent of Siemens / Schneider / ABB / GE
S&F in replacement electronic timer type ET100, 110 / 240V, 50 HZ including necessary electric connection complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No SE 92003 or equivalent in ABB / Schneider
S&F in replacement cooling fan with locking aluminum cast type screw, as per existing type, suitable for 5 / 3 / 1 HP motor complete all as specified & as directed by Engineer –in-charge.
S&F in repair of air blower capacity 400m3/Hr (Make Everest blower) assembled with 30 HP by strip opening of blower and replacement of unserviceable parts i.e. gaskets, oil seal assembly, O ring, sleeve, site glass for oil level complete and assembling of the same after testing complete all as specified & as directed by Engineer –in-charge.
S&F in repair V type fan belt B-69 of air compressor.The fan belt B-69 shall be ISI marked best quality and shall be approved by GE before incorporation in the work complete all as specified and directed by Engineer-in-charge. Make : - Fenner / Dunlop
S&F in repair suction filter assembly with air filter for air blower complete as per existing model and type suitable for 400m3/Hr capacity blower complete all as specified and directed by Engineer-in-charge.
S&F in repair safety valve suitable for 400m3/Hr capacity air blower complete all as specified and directed by Engineer-in-charge.
S&F in repair air pressure gauge suitable for 400m3/Hr capacity air blower, stainless steel body (0-200 Psi) complete all as specified and directed by Engineer-in-charge. Make H.guru
M&L for painting on air blower with motor complete with base frame and other connected items as per existing colour code with spray paint with synthetic enamel paint, weather proof after preparation of old surface by scraping / removing old paint complete all as specified and directed by Engineer-in-charge.
S&F 80mm bore galvanized steel water tubing heavy grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F 100mm bore galvanized steel water tubing heavy grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F 150mm bore galvanized steel water tubing heavy grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
M&L for fabrication of irom frame structure for supporting different pipe network and fabrication of iron jali, stair, sludge scrap trap jali, strainer etc as inlcuding welding work as required at sewage treatment plant including one coat of red oxide oxide premiew and two coat of synthetic enamel paint weather proof complete all as specified and directed by Engineer-in-charge.
S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge
S&F in replacement indicating lamp with holder and cover as per existing complete all as specified & as directed by Engineer-in-charge
S&F in replacement of Thermal over load relay Range 12-18 Amps complete all as specified and directed by Engineer-in-charge. Make : Legrand Cat Pt No 416673 or equvilant in Siemens / C&S / L&T
S&F in replacement of Thermal over load relay range 22-32 Amps complete all as specified and directed by Engineer-in-charge. Make : Legrand Cat Pt No 416676 or equvilant in Siemens / C&S / L&T
S&F in replacement of Thermal over load relay range 28-40 Amps complete all as specified and directed by Engineer-in-charge. Make : Legrand Cat Pt No 416677 or equvilant in Siemens / C&S / L&T
S&F fully automatic star delta starter type MU-G40 FASD having relay of range 36 - 60 Amp 415 volts, 50 Hz with 380 volts coil voltage in sheet enclosure including making electrical connection fixed on wall / frame and testing complete all as specified & as directed by Engineer-in-charge Make :- L&T Cat Part No CS90908LOTO or equivalent Crompton Greaves / ABB / C&S / Seimens
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 16 Sqmm, 3 core complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 79 here-in-above but 10 Sqmm 3 core.
All as per serial item No. 79 here-in-above but 6 Sqmm 3 core.
S&F in replacement On load changeover switch of 400 Amp Capacity, four pole with interlock and padlock facility and handle fixed in existing electric panel including all electrical connection and replacement of lugs / thimbles to existing cable and any addition / alteration to existing panel as required and directed by Engineer-in-Charge. Make : - L&T cat part No SK90480 or equivalent in Havells / Legrand / Schneider
S&F in replacement of PVC cable duct with cover of size 100mm x 60mm including all fitting joints tee etc fixed on wall / floor and laying of existing cable inside duct complete all as specified & as directed by Engineer –in-charge.
S&F in replacement of hinges by welding to electric panel carefully and check for proper opening and closing single and double door panel complete all as specified & as directed by Engineer –in-charge.
M&L for preparation of old painted surface of piping distribution network complete of sewage treatment plant of capacity 1.13 MLD including scrapping old paint, denting and applying two coat of spray paint using synthetic enamel paint as per existing colour code complete with marking indication of flow complete all as specified & as directed by Engineer –in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
S&F in replacement 20mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F in replacement 25mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F in replacement 32mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F in replacement 40mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 32mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 40mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 50mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for motors & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc suitable for centrifugal pump set any capacity and reconstruction of new foundation including two coat of synthetic enamel weather proof paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 3 Pole, 40-100 Amps rating, breaking capacity 36 KA, 415 Volt with thermal magnetic release type complete all as specified and directed by Engineer-in-charge. Make : Legrand Cat Part No. DPX³ 160 420082 to 85 or equivalent in L&T / Schneider / Crompton
S&F in replacement MCCB 3 Pole, 125 Amps rating, breaking capacity 36 KA, 415 Volt with thermal magnetic release type complete all as specified and directed by Engineer-in-charge. Make : Legrand Cat Part No. DPX³ 160 420086 or equivalent in L&T / Schneider / Crompton
M&L for replacement of 'D' Joint suitable for HDPE pipe sizes 60 / 90 / 110mm dia bore including excavation work and other fittings as required including testing at site complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement Cast Iron foot valve for 100 mm bore pipe, ISI marked, class PN-2.0, lift flanged type as per IS-4038 complete all as specified and directed by Engrineer-in-Charge.
All as per Srl item No 105 above but 150 mm dia bore.
M&L for repair to foot valve of 100 / 150 mm size by disconnecting from pipe line and replacement of cast iron door plate assembly, hinge pin / disc guide pin, rubber door face and rubber gasket and fixing on same location and testing complete all as specified and directed by Engrineer-in-Charge.
S&F in replacement Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 100mm bore pipe, ISI marked, class PN-1.6 conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 108 above but 150 mm dia bore.
M&L for repair to non return valve of 100 / 150 mm size by disconnecting from pipe line and replacement of cast iron door plate assembly, rubber door face and rubber gasket and fixing on same location and testing complete all as specified and directed by Engrineer-in-Charge.
Supplying, fixing and testing in replacement of 80mm bore cast iron sluice valve with langed ends drilled ISI marked class PN - 1.6 conforming to IS 14846-2000 with stainless steel spindle with iron wheel, CI gate with brass nut, bolts, washers and rubber packing for connecting pieces etc complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 111 above but 100 mm dia bore.
All as per Srl item No 111 above but 150 mm dia bore.
M&L for repair to sluice valve of 100 / 150 mm size by disconnecting from pipe line and replacement of cast iron gate assembly, stem and rubber gasket, nuts including necessary welding work and fixing on same location and testing complete all as specified and directed by Engrineer-in-Charge.
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
Fixing only 15mm bore old galvanised steel water tubing including cleaning with & including new fittings and fixed complete to walls and ceilings or laid in floors in new or old position complete all as specified and directed by Engineer-in-charge. Note :-GI tubing retrieved vide item No 115 shall be used under this item
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
Fixing only 20mm bore old galvanised steel water tubing including cleaning with & including new fittings and fixed complete to walls and ceilings or laid in floors in new or old position complete all as specified and directed by Engineer-in-charge. Note :-GI tubing retrieved vide item No 118 shall be used under this item
Taking up or down 25mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 25 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
Fixing only 25mm bore old galvanised steel water tubing including cleaning with & including new fittings and fixed complete to walls and ceilings or laid in floors in new or old position complete all as specified and directed by Engineer-in-charge. Note :-GI tubing retrieved vide item No 121 shall be used under this item
S&F Mild steel framed work as in doors or gates, valve pit covers of angle or other sections, MS sheet covers , hinges, locking and fastening arrangement including welding and painting with one coat of black bituminous paint over a coat of red oxide primer conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
M&L for perparation of surface of sheet metal cover of valve pit chamber (100cm x 110cm) by removing old unserviceable paint by one coat of synthetic enamel weather proof paint from inside and outside complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of white wash on valve pit chamber inside of any size complete all as specified and directed by Engineer-in-Charge.
S&F acrylic plate, blue base size 40 cm x 50 cm including printing of machinery specifications (i.e. name, make / model, capacity, date of installation, location etc) fixed to wall complete all as specified and directed by Engineer-in-Charge.
M&L for Construction of brick masonry valve pit of internal size 110cm x 110cm x 110cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock including taking down old valve pit complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit. (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation. --------------------------------------------------------------------------------------------------------------------------------------- Note :- A sum of Rs. 71726/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 27 & 28 (Schedule of Credit) of Tender documents.
J.M.D. CONSTRUCTION CO.
godara construction company
SRI SAI CONSTRUCTION COMPANY
DASHMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .